| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 CrAccepted-AOC | ₹9.1 Cr | L1 | Accepted-AOC AOC |
| 2 | L2₹9.3 Cr+₹15.3 L (1.68%)Rejected-Finance 102 SUBHASH ROAD HERITAGE HEIGHTS DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹9.3 Cr+₹15.3 L (1.68%) | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | L3₹9.5 Cr+₹40.0 L (4.38%)Rejected-Finance N A | PALWAL | HARYANA | 121004 | ₹9.5 Cr+₹40.0 L (4.38%) | L3 | Rejected-Finance Highest Rate Quoted by bidder |
Tender Value
₹9.5 Cr
EMD Value
₹19 L
Closing Date
2 Mar 2017, 5:00 pmClosed
General Manager
Office of the Chief General Manager Construction Wing Uttarakhand Peyjal Nigam Dehradun
Construction of Indoor Shooting Range at Police Line Dehradun
2017_MDPEY_6617_1
Letter No 29/Tender/01 Dated 03.01.2017
Open Tender
Composite Works
Item Rate
270 days
Police Line Dehradun
Please refer Tender documents.
3 documents required · 3 mandatory
₹28,625
General Manager Garhwal Construction Wing UKPJN
₹19 L
Dehradun
17 Jul 2025
5 Jan 2017
4 Mar 2017
6 Jan 2017
2 Mar 2017
27 Feb 2017
23 Feb 2017
Amount
Earth Work
Clearing grass and removal of the rubbish upto a distance of 50 m outside the periphery of the area cleared.
Earth Work Tarace Cutting
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50 m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed. All kinds of soil
Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. All kinds of soil
Extra for excavating trenches for pipes, cables, etc. in ordinary/hard rock exceeding 1.5 m in depth but not exceeding 3 m. (Rate is over corresponding basic item for depth upto 1.5 metre).
Carriage of Material by Mechanical transport including loading, unloading and stacking of good earth at a distance of 1 km
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with Jamuna sand under floors, including watering, ramming, consolidating and dressing complete.
Providing dry trap/ rubble stone soiling of 23 cm to 30 cm thickness including hand packing and compacting etc complete, at different levels Rubble used shall be atleast 150mm thick. Stone shall be hand packed as close as possible and bedded firmly with the broadest face downwards and the greatest length across voids filled with chips and small stones. These shall be hammered down to achieve packing and small stones. These shall be hammered down to achieve packing and the complete filling of interstices. Soling shall be watered and gain packed with sand or morrum to fill interstices created by watering. It shall be rolled with 10MT roller or vibratory compactor. filling sand or murrum, watering and rolling should continue till required compaction is available to the satisfaction of E-in-C
CONCRETE WORKS
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including finishing the top smooth.
Providing and applying Antermite treatment in floor plinth with Chloropyriphos/Lindane E.C. 20% with 1% concentration.
REINFORCED CEMENT CONCRETE
Providing and laying in position ready mixed M-25 grade concrete for reinforced cement concrete work, using cement content as per approved design mix, manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for reinforced cement concrete work, including pumping of R.M.C. from transit mixer to site of laying , excluding the cost of centering, shuttering finishing and reinforcement, including cost of admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer -in - charge
All works upto plinth level
All works above plinth level upto floor V level
Centering and shuttering including strutting, propping etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars
BRICK WORKS
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
FINISHING WORKS
12 mm cement plaster of mix : 1:4 (1 cement: 4 coarse sand)
15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand)
6 mm cement plaster of mix : 1:3 (1 cement : 3 fine sand)
Extra for providing and mixing water proofing material in cement of plaster work in proportion recommended by the manufacturers.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade : New work (two or more coats) over and including water thinnable priming coat with cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre
FLOORING WORK
Cement concrete flooring 1:2:4 (1 cement :2 coarse sand:4 stone aggregate ) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc complete 40mm thick with 20mm nominal size stone aggregate
Providing and fixing glass strips in joints of terrazzo / cement concrete floors 40mm wide and 4mm thick
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), including pointing the joints with white cement and matching pigments etc., complete.
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineering- Charge
Providing edge moulding to 18 mm thick marble stone counters, Vanities :Granite work
complete as per design approved by Engineer-in-Charge. Providing and laying gang saw cut 18mm thick, mirror polished pre moulded and pre polished machine cut granite stone of required size and shape, colour and texture in footpath, flooring in road side plazas and similar locations, laid over 20mm thick base of cement mortar 1:4( 1cement : 4 coarse sand) including grouting the joints with white cement mixed with matching pigment, epoxy touch ups etc. complete as per direction of Engineer in charge.
Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/moulding, rubbing and polishing of cut edges etc. complete.
62 mm thick cement concrete flooring with concrete hardener topping,under layer 50mm thick cement concrete 1:2:4 and top layer 12mm thick cement hardener consisting of mix 1:2 by volume, hardening compound mix @ 2 litrs per 50kg of cement
DOOR & WINDOWS
Providing wood work in frames of door , window, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fasteners shall be paid for separately) Sal wood
Providing and fixing ISI marked flush door shutters confirming to IS : 2202(PART I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains of cross bands and face veneers on both face of shutters.
35 mm thick including ISI marked stainless steel butt hinges with necessary screws Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x70x4 mm (ordinary type)
Providing and fixing bright finished brass tower bolts(barrel type) with necessary screw etc,complete 250x10
Providing and fixing bright finished brass door latch with necessary screws etc. complete :
Brass Door Handles
Providing and fixing Door Stopper
Providing and fixing Fibber Glass Reinforced plastic (FRP) Door Frames
Providing and fixing Fibber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness .The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2 mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fibber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame.
Providing and fixing Glass Portion with 12mm thick toughened glass : Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) :
Powder coated aluminium (minimum thickness of powder coating 50 micron) :Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge.
Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment).
Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineering-charge complete. 205x19mm
Providing and fixing aluminium casement windows fastener of required length for aluminium windows with necessary screws etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineering-charge
WATER PROOFING
Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge
ROOF TRUSS
Providing and fixing percolated galvanised iron profile sheets (size, shape & pitch of corrugation as approved by the engineer in charge ).50mm+/-5% total coated thickness (TCT)thick zinc coating 120 gsm as per IS:277 in 240 mps steel grade 5-7 micron epoxy primer on both side of the sheet &politer top coat 15-18 micron sheet should have protected guard film of 25 micron minimum to avoided scratches while transportation & should be supplied in single length up to 12 m as per directed by engineers -in-charge the sheet shall be fixed using self drilling /self taping screw of size (5.5x55 mm) with EPDM seal or with polymer coated J or L hook ,bolts &nuts 8 mm diameter with bitumen &GI limped washer or with G.I lamped filled with white lead complete up to any pitch in horizontal & vertical or curved surfaces excluding the cost of purlins rafter & trusses & including of size
Providing & metre fixing percolated galvanised steel sheet roofing accessories 0.50mm+/- 5% total coated thickness (TCT)thick zinc coating 120 gsm as per IS: 277 IN 240mpa steel grade ,5-7 microne epoxy primer on both side of the sheet &polyester top coat 15-18microne using self drilling /self taping screw or with polymer coated J or L hooks ,bolt & nuts & or G.I scam bolts & nuts G.I plain & bitumen washer s complete :Ridge Plain (500mm-600mm)
Gutter (600 metre mm over all girth)
steel work in built up tubular trusses including cutting hoisting fixing in position & applying a primer coat of approved primer ,welding & bolted including special shape ,washer etc complete hot finished welded type tubes
Painting 1st coat over primer coat (excluding cost of primer coat)on steel & other steel surface up to 10 cm width or grit or small articles not exceeding 0.10 sqm area with superior synthetic enamel such as LUXCOL
Providing & fixing on wall face un plastered Ridge PVE rain water pipes conforming to IS 13592 Type A including jointing with seal ring conforming to IS 5382 leaving 10mm gap for thermal expansion single socked pipe 75 mm diameter
Providing and fixing double scaffolding system (cup lock type) on the exterior side upto seven story height made within mm dia MS tube 1.5 c/c horizontal & vertical tubes
MISCELLANEOUS WORK
Providing and fixing SS staircase railling 105cm high from nosing in position made out of 304 grade 16 SWG,ss hand rail - 40mm dia with SS end cap and fixed in to wall at end, Mid rail-20mm dia x3row, 1st and last balustrade 75mm x 2 Nos. and other Balustrade 40mm dia x 4 steps per side with base plate of 5mm with SS base cover and complete with all fitting as per design and diagram
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated, or with design ceiling tiles of BWP type phenol formaldehyde synthetic, resin bonded pressed particle board conforming to IS:3087, finished with, a coat of aluminium primer on both sides & edges, including two coats of , synthetic enamel paint of approved quality on exposed face, fixed to a, grid made out of anodised aluminium (with 15 micron anodic coating) Tsections, 35 x15x1.5 mm size main runners, cross runners 23.5x19x1.5, mm fixed to main runners placed 600 mm centre to centre both ways so, as to form a grid of 600 mm square. The frame work shall be suspended, from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof, slab by means of ceiling cleats and dash fastener. The suspenders shall, be placed 600 x 1200 mm centre to centre including fixing to the frame, with C.P brass screws and applying a priming coat of zinc chromate yellow, primer (aluminium frame work shall be paid separately).
12 MM Toughten glass on Floor Spring
Providing and fixing 2nd class teak wood plain lining tongued and grooved, including wooden plugs complete
Mechanical ventilation in 10 m shooting range
Acousntical insulation in 10m shooting range
WATER SUPPLY PIPING ( COLD & HOT):
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having, thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing, This includes jointing of pipes & fittings with one step CPVC solvent cement, and the cost of cutting chases and making good the same including testing, of joints complete as per direction of Engineer in Charge, Concealed work, including cutting chases and making good the walls etc.
32 mm dia.
25 mm dia.
20 mm dia.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having, thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one, step CPVC solvent cement ,trenching ,refilling & testing of joints complete, as per direction of Engineer in Charge. EXTERNAL WORK
75 mm dia.
62.50 mm dia.
50 mm dia.
40 mm dia.
32 mm dia.
25 mm dia.
Supply, installing, testing and commissioning of ISI marked Gun Metal, gate valves screwed pattern conforming to IS 778 class 1 including, jointing, supporting etc complete and as directed.
80 mm dia. - Gate Valves
65 mm dia. - Gate Valves
50 mm dia. - Gate Valves
40 mm dia. - Gate Valves
32 mm dia. - Gate Valves
25 mm dia. - Ball Valves
RAIN WATER & SOIL/WASTE/VENT (SWV) PIPING:'Supply, laying , testing & commissioning of UPVC-SWR pipes conforming, 'to IS 13592/92 and fittings conforming to IS-14935/99, cutting the pipes, to required lengths, laying in position to required grade and level, jointing, making holes, pockets, chases in walls, floors of all types and making good the same, testing and rectifying leakages for concealed piping within toilet blocks, sunken slab, plinth etc. complete and as directed.
110 mm dia.
80 mm dia.
40 mm dia
32 mm dia
Supply, laying, testing & commissioning of UPVC-SWR pipes conforming, to IS 13592/92 and fittings conforming to IS-14935/99, cutting the, pipes to required lengths, laying in the position to required grade and level, jointing, supporting with cleat / clamp / bracket support, testing and rectifying leakages for piping within vertical shafts / supported on, wall / hung below slab etc. complete and as directed.
300 mm dia.
250 mm dia.
110 mm dia.
75 mm dia.
Supply, laying, testing & commissioning of Heavy duty ISI marked, Floor Drain / Nahani trap & Clean Out Plug with approved make heavy duty, round or square SS grating, 'etc. complete and as directed
300 mm dia. Outlet Floor Drain (F.D) at Terrace Floor, (Indore Sport comp)
250 mm dia. Outlet Floor Drain (F.D) at Terrace Floor, (Indore Sport comp)
110 mm dia. Outlet Outlet Floor Drain (F.D) & C.O.P ( 2 + 2) respectively.
80 mm dia. Outlet Nahani Trap , P. Trap & C.O.P (142 + 21 + 4) respectively.
Providing & fixing vent cowl / guard / balloon with wire on terrace including jointing etc. complete.
110 mm dia
80 mm dia
SANITARY FIXTURES & FITTINGS:
Providing and fixing white vitreous china pedestal type water closet, (European type) with seat and lid, 10 litre low level white vitreous china,W.C. pan with ISI marked white solid plastic seat and lid
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per 510x1040 mm bowl depth 250 mm
Providing and fixing Off-white/Ivory glazed vitreous Under Counter / Counter Top Hand Wash Basin of 1st Quality of approved make, with attached Basin Pillar cock including providing and fixing C.P. inlet connections from Angel Stop cocks to Basin Mixer, C.P. waste coupling and C.P. bottle-trap with extension piece of approved make, including providing and fixing M.S. brackets for the same, including cutting and drilling holes in floors and walls and making good the damages etc. complete
Installation, testing and commissioning of shower assembly including 15mm x 150mm long including connecting inlet and outlet to main piping, cutting and making good the walls etc. complete and as directed.
Providing and Fixing in position storage type storage water heater capacity 50 liters ‘ mild steel body Sphere hot’ ‘Venus’ ‘Racold’ or other approved make and horizontal wall mounted type including making water connections with stop cocks, pressure reducing valve if required, safety pressure release valve etc. complete.
Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, '200 mm wide with minimum distances of 37 mm from wall face with 'concealed fittings arrangement of approved quality and colour, weighing 'not less than 88 gms.
'Providing and fixing toilet paper holder : C.P. brass
Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm, 'high and 112 mm distance from wall of standard shape with bracket of 'the same materials with snap fittings of approved quality and colour, 'weighing not less than 105 gms.
Providing and fixing brass bib cock of approved quality : 20 mm nominal bore
Installation, testing and commissioning of 15 mm dia CP. brass ablution tap with hose union and CP. wall flange of approved quality.
Installation, testing and commissioning of 15 mm dia CP. brass. Hand Spray or Jet spray with C.P. pipe connection and 15 mm C.P. angle stop cock.
EXTERNAL SEWAGE AND STORM WATER DRAINAGE SYSTEM:Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :
100 mm dia.
150 mm dia.
200 mm dia.
250 mm dia.
Constructing brick masonry chamber for underground C.I. inspection, chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse, sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover, 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation, concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40, mm nominal size), inside plastering 12 mm thick with cement mortar 1:3, (1 cement : 3 coarse sand), finished smooth with a floating coat of neat, cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 600x 850 mm and 45 cm deep for pipe line, with three or more inlets : With common burnt clay F.P.S. (non modular) bricks of class :designation 7.5
Providing and fixing square-mouth S.W. gully trap class SP-1 complete, with C.I. grating brick masonry chamber with water tight C.I. cover with frame o f 300 x300 mm size (inside) the weight of cover to be not less, than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type, With common burnt clay F.P.S. (non modular) bricks of class :designation 7.5
Supply, laying, testing and commissioning of 230 mm thick BB masonry, rectangular Storm Water Chamber of a depth of 1.0 m, 150 mm thick, bedding in CC 1:2:4 inside and outside plaster in cm 1:3, C. I. rungs, weighing 5.2 kg each, C. I heavy duty frame and cover of size 0.9 x 0.9 m weighing 125 kg including excavations, dewatering shoring, and strutting, backfilling etc complete as directed.
Size 900mm x 600mm
Size 900mm x 900mm
Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes, including collars/spigot jointed with stiff mixture of cement mortar in the, proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc.complete
450 mm dia RCC pipes.
600 mm dia RCC pipes.
2.30 m deep with SFRC Cover and frame (heavy duty HD- 20 grade designation) 560 mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be not less than, 182 kg. fixed in cement concrete 1:2:4 (1 cement : 2 coarse, sand : 4 graded stone aggregate 20 mm nominal size) including centering, shuttering all complete. (Excavation, foot rests and 12 mm thick cement
With Sewer bricks conforming IS : 4885 each
a) Upto 2.0 m depth
b) Upto 3.0 m depth
Constructing brick masonry circular manhole 1.22 m internal dia at bottom and 0.56 m dia at top in cement mortar 1:4 (1 cement :4 coarse sand), inside cement plaster 12 mm thick with cement mortar 1:3 (1 cement : 3, coarse sand) finished with a floating coat of neat cement foundation, concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40, mm nominal size) and making necessary channel in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement, all complete as per standard design :
With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
With Sewer bricks conforming IS : 4885
EXTERNAL WATER SUPPLY SYSTEM:
Providing and fixing G.I. pipes complete with G.I. fittings including trenching 'and refilling etc. External work 80 mm dia.
'Supply, laying, testing and commissioning with bitumastic hessian cloth over 'two coats of anti-corrosive paints of G. I. heavy duty "C" class pipes. 80 mm dia.
Excavation , dewatering, backfilling, wrapping and supporting wherever required as directed.
Providing and fixing enclosed type water meter (bulk type) conforming to 'IS : 2373 and tested by Municipal Board complete with bolts, nuts, rubber, insertions etc. (The tail pieces if required will be paid separately) : 80 mm dia nominal bore
Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4, graded stone aggregate 20 mm nominal size) , i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar, 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With common burnt clay F.P.S.(non modular) bricks of class: designation 7.5
PUMPS AND EQUIPMENT:
Supply, installation, testing and commissioning of centrifugal closed coupled water pumps with motors mounted on a single base frame, complete with all accessories, suction/discharge butterfly or gate valves, suction strainers, discharge non-return valves, pressure gauges and of the following capacities.
a) For Domestic Water Supply (From U.G Tank to O.H Tank) 300 lpm @ 3.5 kg/cm2 discharge pressure of 15m Head.
b) For Flushing Water Supply (From U.G Tank to O.H Tank) 250 lpm @ 3.5 kg/cm2 discharge pressure of 15m Head.
OVER HEAD WATER TANK:
Providing and fixing of OHWT PVC 5000 ltrs. 2 nos. (Water Supply & Flushing) at roof level, complete job
Wiring for light point/ fan ponit/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required. Group-B
Wiring for light/ power plug with 2x4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2X1.5 sq.mm. + 1X 1.5 sq.mm earth wire
2X2.5 sq.mm. + 1X 2.5 sq.mm earth wire
2X10 sq.mm. + 1X 10 sq.mm earth wire
S/L co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing PVC conduit as required.
Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way modular switch, modular plate, suitable Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc
S/F of following sizes of PVC conduit along with accessories in surface/recess including cuttting the wall and making good the same
S/F suitable size Gl box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection, painting etc. as required
S/F suitable size GI box with modular plae and cover in front on surface or in recess, including providing and flxing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc. as required.
S/F call bell/ buzzer suitable for D.C/A.C single phase, 230 volts, complete as required.
S/F way, three pole and neutral, prewired, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with loose wire box, terminal blocks, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper busbar, neutral link, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted i/c earthing etc. as required. (But without MCB /RCCB/lsolator) 8 way (4 +24), Double door,
S/F 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for lighting and other loads Single pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissoning etc. as required..
Earthing with G.I earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.
S/L 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including soldering etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing plate switch box including connections all as dirceted.
S/F 3 pin, 5 amp. ceilling rose on the existing junction box/ wooden block including connection etc. as required
S/F brass batten/angle holder i/c connection etc. as required.
S/F following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
Telephone socket outlet
TV antenna socket outlet
S/F metal box of 75mmx75mmx60mm deep on recess with suitable size of phenolic laminated sheet cover in front including painting etc. required
P/L plain 16/0.20 mm twin, FR PVC insulated, PVC flat flexible copper cable on the floor/ wall, or side of the table/ door etc. as required.
Supplying,fixing& Installation of LED lamp 20 watt (Crompton/Havells make)
Supply & Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting (Type T5)of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.(Crompton/Havells make)
Supply & Installation of exhaust fan in the existing opening, including making the hole to suit the size of the above fan, making good the damage, connection, testing, commissioning etc. as required. Orient Make
upto 300 mm sweep
P/F bracket Light (Crompton/Havells make) with lamp
S/F, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable etc. as required. (1200 mm sweep) Orient/Bajaj make Model NEW BREEZE.
Supply and fixing of Mirror light 1x10Watt ,Model No. LCL-10-CDL,Make Crompton/Havells
S/F of Decorative Ceiling light fittings with thermoplastic High Impact Compact fitting in CFL 18 watt complete all in respect.Make Crompton/Havells
S/F single pole blanking plate in the existing MCB DB complete etc. as required. (5 no. /MCBDB)
Supply & Fixing of 30A T.P.N MCB industrial Socket Outlet with 4 Pole and Eath Metal Oncloser Top along with 30 A "c" Series TPMCB M Sheet incloser on surface or in recess with metal Cover For Socket out Let and Complete with connection testing and commissioning etc (Pole Box three phase)
G.I earth plate elctrode: Earthing with Copper earth plate 600 mm x 600 mm x 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 Mtr etc. with charcoal or coke and salt ) as required.
S/L 25mm x 5mm Copper earth strip in groun Supplying and laying 25 mm x 5 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including Conection terminative with G.I. Nut Bolt, Spring Washer etc.
Supply & Making Outdoor end Termination with cast resin Compound including lugs and other jointing materials for PVC insulated and PVC Sheathed/XLPE Aluminium Conductor cable of 1.1 KV grade as Required 3x120 sqmm.
Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE Aluminium conductor cable of 11 KV grade 120 sqmm x 3 core.
Supplying and making Outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE Aluminium conductor cable of 11 KV grade 120 sqmm x 3 core.
Supply & laying of Aluminium Conductor PVC insulated armoured seved sheathed cable 1100 volt grade.
10sqmm x 4 core Cat A
35 Sqmm x 3.5 core Cat A
240 sqmm x 3.5 core Cat A
16sqmm x 4 core Cat A
Supply & fixing of Brass Nickle Plated Compression Gland for PVC Cable.
10sqmm x 4 core.
16sqmm x 4 core
35 Sqmm x 3.5 core.
240 sqmm x 3.5 core.
Supply & fixing of Plane or pin Type Aluminium Tin Plated Cable Socket (lugs).
Supply & Laying of G.I Pipe.
Additional works
Supplying & erecting XLPE armoured cable 12 core 1.5sq.mm. copper conductor complete erected on wall/ceiling/cable trays with mounting accessories.
Supply & laying of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting compound in combination with copper tape(0.3KA for 1 sec) cores laid off, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments.(a)3 core 120 sq.mm. Cable to be laid in laid hume pipe in ground.
Supply & installation of cable chambers for the external cable laying comprising of 1Mtr.x 1Mtr. X 1.5Mtr. Deep complete with cast iron cover.
Supply & erection of XLPE armoured copper cable 4 core 4 sq.mm. complete erected on wall/ceiling/cable trays with mounting accessories.
Termination of 4 core 4 sq.mm. copper armoured cable using glands & copper lugs.
Supply, installation, testing & commissioning of 100KW/ 125KVA, 415V, 50Hz. Silent Diesel Generating sets, each set comprising of: “Cummins”/Perkins/equivalent Model Diesel Engine, Radiator cooled, complete with standard accessories(or equivalent) Coupled to :“Stamford”/Leroy Semor/EQUIVALENT Alternator rated at 100KW/125KVA at 415 Volts(or equivalent) mounted on Channel Iron Base Frame Complete with 340 Lts capacity External Fuel Tank12V Batteries, Accoustic Enclosures with Set Mounted Breaker, Exhaust Chimney as per norms. Each Genset should have individual Genset Control Panel (GCP) & Manual Control Panel.Rate shall be inclusive of RCC foundation including complete in all respects for the DG set, accoustic enclosure, exhaust pipe.
Supplying & erecting XLPE armoured cable 12 core 1.5sq.mm. copper conductor complete erected on wall/ceiling/laid pipe etc. using MS spacers, saddles, screws etc.
SUBSTATION
Supply, Installation, testing and commissioning of compact substation having 125 kVA, 11KV/433V, copper wound, oil cooled outdoor type transformer with off load tap changing facility, which is to be as per the specification and the data sheets provided. Incoming HT RMU with SF6 circuit breaker of 630A. capacity. Outgoing Moulded case circuit breaker 400A. 36kA. 4P MCCB Manual fixed type with overcurrent, short circuit releases. The rate includes the cost of frame work for the compact substation(PSS). The rate given is the total cost which includes both the cost of supply and installation. Compact substation to be internal arc tested as per standard norms.
Providing and fixing of lightning conductor finial, made of 25 mm dia 300mm long, copper tube, having single prong at top, with 85mm dia 3mm thick copper base plate including holes etc. complete as required.
Supply & laying of following size of 3 core, HV, 11 KV grade, ISI mark, XLPE cable with stranded compact circular aluminium conductor, conductor screened with extruded semiconducting compound, XLPE insulated, insulation screened with extruded semiconducting compound in combination with copper tape(0.3KA for 1 sec) cores laid off, inner sheath of PVC tape, galvanised steel flat strip armoured and overall PVC sheathed cable conforming to IS:7098(Part II) with latest amendments.(a)3 core 70 sq.mm. Cable to be laid in laid hume pipe in ground.
Supplying & making outdoor cable end jointing with cast resin compound, including lugs & other jointing materials, for following sizes of 3 core, XLPE aluminium conductor cable of 11KV grade as required(70 sq.mm.)
Supply & installation of safety equipments in substation:-
Providing and Fixing in position approved shock treatment chart written in English, Hindi & local language. The chart shall be framed in teakwood frame and covered with glass.
Providing and Fixing in Position 4.5 Kg capacity CO2 type fire Extinguishers.
Provided pair of duly tested rubber hand gloves as per IS:340715 suitable for working on 11/22kV supply.
Providing round bottom FIRE Bucket of 9 litres capacity as per IS:2546 made out of 24 gauge GI sheet with extra handle at bottom duly painted white inside and red outside with FIRE mark on provided stand/wall hook.
Providing floor mounting stand for keeping 4 nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm. angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint.
Supplying Standard first aid box with necessary antiseptic cream, medicine for use on wounds due burn, crepe bandage, gauge bandage, medicated ready to use bandage(Band - Aid) adhesive tape for medicinal use, scissors, anti-septic solution(Savlon or similar) etc.
Providing and fixing H.T. danger notice plate of 200 mm X 150mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing and fixing M.V. danger notice plate of 250 mm X 200mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Providing printed instructions chart for treating persons suffering from electric shock in English & local language & duly laminated.
Supply & installation of HT Metering Kiosk rated for 11 KV - Hupen Make/equivalent make with PT & HT isolators in ip65 enclosure.
Preparing plinth for package substation 4 mtr. X 6 mtr. X 1.5mtr. In size with necessary excavation in the ground at the bottom with 150mm. Thick M 10 PCC at the bottom & top & 250mm thick burnt brick wall construction at periphery & remaining hollow portion shall be filled with 60mm. hard broken aggregate, external surface duly plastered 15mm. thick including watering etc. complete.(1.5mtr. height)
Supplying & erecting fencing of section having size 2450mm. In height from ground level and 1200mm. Width with angle iron fram work erected in foundation and painted.
Supplying & erecting double leaf hinged door each 1500mm. In width x 1850 mm. in height using B class, GI pipe with angle iron supports, chain link wire mesh(jali) complete supported on channel iron, erected in foundation, and painted.
Supply & fixing of Street Light 85 watt.
Supply & fixing Endura Cityliner 24 New generation enery saving & Environmental friendly long life versatile pressure die-cast aluminium roadway luminaire with high power LEDs as light source and HF electroninc driver.(48W LED 6K LHRD022246714)
S/F steel tublar Pole 9 Mtr long designated 410SP-29 in 1:3:6 cement concrete foundation including excavation back filling etc.
Painting of the Electric pole with 2 Coat of Aluminium Paint over Red oxide primer complete.
Supply and installation of 1/3" Colour Dome cameras with 3.6mm fixed lens, 480 TV lines resolution.(equivalent to Capture make)
Supply & installation of power supply units for cameras.
Supply & installation of outdoor camera in weatherproof enclosure.(equivalent to Capture make)
Supply and Installation of 19" Colour LCD Flat Screen Monitor.(equivalent to Dell make)
Supply and Installation of 16 channel Digital Video Recorder with 1000 GB HDD and with IP connectivity.(equivalent to Hikvision make)
Supply and laying of 2c x 1.0 Sq.mm Armoured cable.
Supply and laying of RG11 Armoured cable for video transmission.
Supply & installation of 6W Cone type ceiling mounted speakers with line matching transformer.(Equivalent to Bosch)
Supply & installation of 6W box type mounted type Speakers with line matching transformer.(Equivalent to Bosch)
Supply & installation of system controller.(Equivalent to Bosch)
Supply & installation of Amplifier 480 W.(Equivalent to Bosch)
Supply & installation of call station.(Equivalent to Bosch)
Supply & installation of CD Changer cum MP - 3 Player.(Equivalent to Bosch)
Supply & installation of 4core 40/36 Twin twisted Copper armoured cable for the PA system wiring activities to be laid partly on the walls/ceiling using MS spacers, saddes, screws etc. & partly in the ground.
M/S Shiv Kumar Agarwal
M/s Mahalaxmi Construction
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_8646.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .