Name Of Work :- A & A to Street Light on State Highway & Major District Road (MDR) of Devbhoomi Dwarka
Qty. Unit Description of Item Net Rate Per Amount
1 145.00 Mtrs Providing and erecting ISI mark Medium class RIGID PVC 24.24 Mtr.
. PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of
pipes, in approved manner as directed (a)20 mm
2 145.00 Mtrs providing and erecting Mains with ISI marked, 1.5kV grade 70.70 Mtr.
. electrolyte multi stranded, annealed copper conductor
with heat resistant PVC insulated conforms to IS 694, IEC -
227 erected in existing pipe of following size (Specifically
for control panel, relays, power switchgears, motor starters
& control wiring) with required size of copper lugs, nuts
and bolts if required. (e) One wire 6.00 sq. mm
3 2928.00 Mtrs Supplying and erecting Flexible PVC insulated multi strand 58.58 Mtr.
. multi core 1.1 kV grade ISI marked copper wires of
following size to be erected as directed. (e) 1.50 Sq.mm
core round PVC sheathed
4 366.00 Nos. Supplying and erecting LED street light / Flood light fittings 6695.29 Ea.
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate
optics/ lenses, with toughened glass with company
mark/name engraved or embossed 160 to 270 V,Power
Factor more than 0.95, THD < 10 %, CCT 3000 K to
5700K,Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.) (A) Street Light (IP-
65), Surge protection -4KV integral and ,Light must have
440VAC line supply with over-voltage protection. (v) 120 -
159 watts Cat. III
Qty. Unit Description of Item Net Rate Per Amount
5 7.00 Nos. Providing and erecting Approved make Four pole moulded 7469.25 Ea.
case circuit breaker having breaking capacity ICU of 25 KA.
at 415 V,having normal current rating up to 25 A to 100A.
with Fixed thermal & magnetic release suitable to work on
A.C. supply 50 Hz. with all internal connections, spreader
tinned copper & complete erected in existing 16 G.M.S.
housing. ICS=100% of ICU only Cat III [Note:-1 Add Rs.
10% extra for housing/Encloser of MCCB for Item No 3-4-1
to 3-4-12 (The Enclosures should be used of same company
of MCCBs to be used)]
6 7.00 Rn. Providing and erecting busbar chamber confirming to IS- 4421.78 Rn.Mtr
Mtrs 375 fabricated from 16 G.M.S. sheet, dust & vermin proof
. having hinged door with rubber gasket and necessary
busbar supports with COPPER busbar having current
density not more than 1.6 Amp. / sq.mm (Rated current /
cross section area) duly wrapped with colour insulation
tape for phase sequence, three phase & neutral each
suitable for following current capacity with necessary
painting mounted on wall or pedestal frame of required
size with necessary connections. (A) Suitable for 63/100
7 366.00 Nos. providing and erecting Miniature circuit breaker single pole 297.95 Ea.
0.5A to 2A system and having breaking capacity 10 KA to
be erected in existing box. confirming to IS 8828/1996 with
ISI Mark Cat. III
8 22.00 Nos. Providing and erecting Sheet Steel powder coated MCB 355.52 Ea.
distribution board - flush / surface mounted fitted with
busbar, neutral link, earth bar and DIN rail, Conforms to IS
8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same
company of MCB to be used) suitable for (A) single phase
incoming and horizontal single phase outgoing (a) single
door (IP-30) (i)4 way
9 22.00 Nos. Providing and erecting Approved make RCCBs conforming 3344.11 Ea.
to IS: 12640 and having sensitivity of 30 mA and Short
Circuit withstand capacity of 10 KA and suitable for
operation on 3 phase and neutral 415V,50Hz. having
characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component for
following Max. rating erected as directed. (iii) 63 Amps. FP
Qty. Unit Description of Item Net Rate Per Amount
10 14.50 Kgs Providing and erecting Annealed bare Copper wire 794.87 Kg.
11 29.00 Nos. Supplying & erecting earth pit of minimum bore 4591.46 Ea.
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free hot dipped G.I.Pipes having Outer
pipe dia of 50mm having 80-200 Micron galvanising, Inner
pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic
value surrounded by highly conductive compound with
high charge dissipation suitable for following type of
applications with chamber and heavy duty cover.
(A)(approved make OEM has to submit test certificate
including value of earth resistance of installation duly
stamped and signed by agency and officer Incharge has to
ensure the value of earthing resistane mentioned in test
Certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 ohm / meter
testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no
load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to
retain moisture for long time Necessary test report must
be submitted by Agency. (a) For Electrical Installation up to
440V in normal soil Length of pipe - 1 Mtr Back filling
compound - 1 Nos Bag of 15 Kg.
12 15656.00 Mtrs Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI 168.67 Mtr.
. armoured cable multistrand / Solid Aluminium conductor
for 1.1 kV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables (C) 4 core
13 3690.00 Mtrs Providing and erecting FRLS-XLPE (IS:7098)(I)-88 ISI 184.83 Mtr.
. armoured cable multistrand Aluminium conductor for
kV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables (A) 4 core 16 Sq.
14 9397.00 Mtrs Making trench in soft soil of suitable width of 90 cm deep 55.55 Mtr.
. for laying cable or locating the fault all over the run and
back filling the same and making the surface as normal
15 4700.00 Mtrs Making trench in Hard Murrum / Tar Road of suitable 74.74 Mtr.
. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
16 787.00 Mtrs Making trench in Hard Murrum / Tar Road of suitable 357.54 Mtr.
. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground. (B) If
additional machinery like hammer driller or JCB use [Add]
Qty. Unit Description of Item Net Rate Per Amount
17 225.00 Mtrs Drilling the road without breaking the road surface 616.10 Mtr.
. (Asphalt) for laying of cable for feeding power supply by
making up to following size of holes at both ends complete.
(B) Up to 150 mm bore dia
18 206.00 Mtrs Providing & laying. R.C.C. Hume pipe for cable to be laid 90 226.24 Mtr.
. cm. below ground across the road crossing or on floor with
necessary material in an approved manner and making the
ground as per original. (F) 100 mm dia.
19 18962.00 Mtrs Providing & laying approved make Double walled 62.62 Mtr.
. corrugated pipes (DWC) of polyethylene(conforming to IS
14930 II )with necessary connecting accessories of same
material at required depth in existing trench for laying of
cable. below ground / road surface for enclosing cable
(A)50 mm outer dia
20 22.00 Nos. Providing and, fixing heavy duty flange type brass cable 38.38 Ea.
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (C) 2 to 4 core 10 Sq. mm
21 51.00 Nos. Providing and, fixing heavy duty flange type brass cable 47.47 Ea.
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables. (D) 2 to 4 core 16 Sq. mm
22 88.00 Nos. Solder less crimping type Aluminium lugs conforming to IS 13.13 Ea.
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (B) 10 Sq.mm
23 204.00 Nos. Solder less crimping type Aluminium lugs conforming to IS 15.15 Ea.
suitable for cable of following size evenly crimped with
high pressure tool & connected to switchgear terminals
with brass/cadmium plated nut bolts in an approved
manner. (C) 16/25 Sq.mm.
Qty. Unit Description of Item Net Rate Per Amount
24 198.00 Nos. Supply of approved make FRP Pole having following 18565.82 Ea.
specifications: FRP Light Pole made by CNC filament
winding machine using thermoset resin polyester/epoxy
resin system) having minimum 62% glass content. The pole
should be in one piece and tapered round in shape, having
smooth finish and should be totally free from corrosion as
well as non conductive & shock proof Pole should be
provided with FRP Anchor Base and it should be heavy
duty, or MS Material duly painted with Epoxy paint. Pole
should be flame retardant as per IS 6746. Resin used shall
be UV resistance and pigmented. A highly weather
resistant polyurethane coating shall be applied to the pole
after applying suitable primer system that ensures proper
adhesion of the paint. Minimum coating thickness shall be
80 to 100 micron. Deflection of the pole shall not exceed
more than 10% of the length of pole for the given load“
Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability
features of poles as per standard ANSI C 136.20 latest
version or ASTM D 4923/01 including cable termination
box with necessary accessories .
The size of pole and type of installation with foundation as
per manufacturer details and site requirement are as
below . (1) Suitable for base plate mounting single arm
Bracket. [J] Overall length of 7 Mtr.Average Thickness:
7.5mm. Top/ Bottom OD Dia A/F 89/183 mm ± 2mm
approx. approx. Weight of Pole 40 kg approx. (Without
Base) Anchor Base (Size 300X300 & 18mm th.)
Qty. Unit Description of Item Net Rate Per Amount
25 84.00 Nos. Supply of approved make FRP Pole having following 19195.05 Ea.
specifications: FRP Light Pole made by CNC filament
winding machine using thermoset resin polyester/epoxy
resin system) having minimum 62% glass content. The pole
should be in one piece and tapered round in shape, having
smooth finish and should be totally free from corrosion as
well as non conductive & shock proof Pole should be
provided with FRP Anchor Base and it should be heavy
duty, or MS Material duly painted with Epoxy paint. Pole
should be flame retardant as per IS 6746. Resin used shall
be UV resistance and pigmented. A highly weather
resistant polyurethane coating shall be applied to the pole
after applying suitable primer system that ensures proper
adhesion of the paint. Minimum coating thickness shall be
80 to 100 micron. Deflection of the pole shall not exceed
more than 10% of the length of pole for the given load“
Pole should be generally made as per the dimensional
data, performance criteria and some interchangeability
features of poles as per standard ANSI C 136.20 latest
version or ASTM D 4923/01 including cable termination
box with necessary accessories .
The size of pole and type of installation with foundation as
per manufacturer details and site requirement are as
below . (2) Suitable for base plate mounting Double arm
Bracket. [E] Overall length of 7 Mtr. Average Thickness:
8mm. Top/ Bottom OD Dia A/F 114/183 mm ± 2mm
approx. approx. Weight of Pole 47 kg approx. (Without
Base) Anchor Base (Size 300X300 & 18mm th.)
26 198.00 Nos. Providing FRP arm bracket of having 2 sets of suitable 2934.05 Ea.
SS304 hardware for fixing the brackets & spread of
Mtr(Suitable for 89 to 114 mm pole top dia) (A) Single arm
27 84.00 Nos. Providing FRP arm bracket of having 2 sets of suitable 4524.80 Ea.
SS304 hardware for fixing the brackets & spread of
Mtr(Suitable for 89 to 114 mm pole top dia) (B) Double arm
Qty. Unit Description of Item Net Rate Per Amount
7.00 Nos. Supplying & erecting IP 55 grade following size section 16691.26 Ea.
pillar fabricated from joint less M.S. Sheet with angle iron
legs made from jointless M.S. Angle with cable clamps to
be buried in ground to have appropriate erection to work
uniform until erected with cement concrete foundation
and 45 cm high bricks work finishing with plaster etc.
hinged double door internally supported on both side, with
internal and outside looking arrangement with lock and
keys in duplicate 35 x 35 x 5 mm M.S. Angle of Two Nos.
one is welded and other with nut and bolt for erecting
Bakelite sheet. Painting the Section Pillar inside and out
side with three tank powder coated paint. section pillar
roof should be without joint with water leakage proof &
tested as per IP 55 test & followed by IS 2147 of 1962 (A)
150 X 90 X 75 cm section pillar fabricated from 14 Gauge
MS Sheet with angle iron legs 95 cm long made from 40 X
40 X 6 mm thick MS angle.
29 7.00 Sq.M Supplying and erecting HYLAM sheet on existing angle iron 1541.26 Sq.
trs. frame.for following thickness (D) 8mm Mtr.
30 22.00 Nos. Supplying & erecting approved make IP 55 grade Company 17059.91 Ea.
fabricated Timer Panel of following capacity for switch On-
Off street lights on time scheduling basis made from 16G
CRCA sheet duly epoxy power painted inside and outside
with hinged doors and locking arrangement consisting of
suitable size of 4 Pole MCB and 4 pole contactor (cat-
III)with analog time switch, auto manual switch of same
make and suitable input and output Bakelite terminals
and with door earthing approved by Engineer in charge. (C)
Net Amount Put toTender Rs.
Note : This Estimate has been prepared as per new SOR which is exclusive of GST hence additional GST will be
paid to the agency as per existing guidlines.
Deputy Executive Engineer Executive Engineer
Electrical (R&B) Sub Division Electrical (R&B) Division
Jamnagar Rajkot
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
ONLINE_NOTICE(R-2)(dn) DBD.pdf
sch B.pdf
SPECIAL CONDITION - DBD.pdf
Standard Specification for Electrical Work.pdf
Technical_Specifications_Street_Light_.pdf
SBD.docx
DOCX
Contractor_Registration_Paripatra__1_.pdf
EMD GR.pdf
GR for single Tender.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .