Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BID | |
| 2 | L2₹43.0 L+₹6.9 L (19.3%)Rejected-Finance 224 OFFICERS ENCLAVE BEHIND PLV MEMORIAL COLLAGE SHIKARGARH ARMY AREA JODHPUR RAJ 342001 | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance HIGHER BID | |
| 3 | L3₹46.5 L+₹10.5 L (29.1%)Rejected-Finance | L3 | Rejected-Finance HIGHER BID |
Tender Value
₹42.9 L
EMD Value
₹86,000
Closing Date
27 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF JODHPUR
HQ CWE AF JODHPUR 342011 Rajasthan
PROVN OF UPGRADING ELECTRICAL INFRASTRUCTURE IN ALL MD ACCN TO IMPROVE QUALITY OF LIFE IN PHASE MANNER AT AFS PHALODI
2023_MES_582987_1
85983/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF PHALODI
as per NIT
8 documents required · 8 mandatory
₹500
GE AF PHALODI
₹86,000
Yes
6 Jul 2023
25 Feb 2023
29 Mar 2023
25 Feb 2023
27 Mar 2023
13 Mar 2023
Amount
Supply, installing, testing and commissioning in door type stepdown transformer, 11000/433 Volts (at no load) AC, 3 phase, 50 Cycle,500 KVA, core type copper wound,oil immersed, naturally cooled, Oilnatural, air natural (ONAN), withexternal cooling tubes, deltaconnected on primary side (HV) and star connected on secondary side(LV) in accordance with vectorsymbol. DYN-11 (Vector Group) with neutral brought out on secondary side(LV side) and having tapping at (+/-) 2.5% to (+/-) 7.5% in steps (+/-) 2.5% HV side to be changed by means of hand operated off load tap changer gear. The maximum temperature rise should not exceed 45 degree Celsius in oil and 55 degree Celsius in HV/LV winding when measured by resistance method after continuous full load run on an ambient temp of 40 degree Celsius. The transformer shall be IS : 2026 marked and shall comprise of the following :- (a) One cable box on HV side (Primary side) consisting of 3 Nos porcelain bushing suitable for 11 KV complete with bushing, copper rods, nut and washers. (b) One cable box on LV side (Secondary side) consisting of 3 Nos porcelain bushing with copper rods suitable for 0.433 KV complete with bushing, copper rods, nut and washers. (c) Oil conservator with filter type drain valve and oil level gauge. (d) De-hydrating breather with first fill dehydrating agent (silica gel). (e) Explosive vent. (f) Thermometer pocket on tank cover. (g) One No 100 mm dia, dial type thermometer, vapour pressure type having range 0-120 degree Celsius with metal guard having maximum perimeter reading temperature indicator with resisting device for transformer. (h) Two earthing terminals to be provided diagonally on either side of tank cover to facilitate fixing of 32X6 mm galvanized iron earth strip for earthing of neutral and body. (j) Rating plate and terminal marking plate. (k) Oil level gauge. (l) Oil drain filler valve. (m) Lifting lugs (n) Oil filling hole with cap/plug with connecting plate complete. (o) Air release valve plug.(p) Four plain solid cast steel detachable rollers. (q) First filling of new and unused transformer oil IS-335/93 (fourth revision) marked filtered and tested up to 60 KV dielectric strength at 2.5 mm air gap between testing electrodes. (r) One danger notice board having conventional danger sign of skull with bones in painted in red colour. Note: Certification of dielectric strength shall be submitted by the contractor after filling the oil.
Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty)with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sq mm.
Supply and joint cable box HT 11 KV INDOOR door heat shrinkable type complete with jointing material & suitable for 3 core XLPE armoured Al condudtor cable of size 95 sqmm complete.
Supply and install, testing and commissioning of LT panel board indoor cubicle type floor mounted metal enclosed fixed type,free standing,floor mounting,compartmentalized,modular type suitable for indoor installation,cubical type,factory assembled in bolted design fabricated from 2.0 mm thick CRCA sheet steel frame work and painted with two coat of synthetic enameled paint, degree of protection IP-54 as per IS-13947,consisting high conductivity bus aluminium bus bar of suitable size with heat shrinkable sleeves,fault rating 50 kA for 1 sec, including multifunctional digital voltmeter,ammeter,frequency meter and power factor meter,The drawing of the LT Panel board will be approved by Engr-in-Charge and the same have the following electric controls :- (Main LTP At MAP Sub Stn ) (a) ACB 1000 Amp,4 Pole ,415Volt, with thermal magnetic release (Manual drawout type) of - 1 No.(I/C) (b)MCCB 800 Amp, 50 kA,4 Pole - 1 Nos.(O/G ) (c) CTs 500/ 5 ma - 1 Set of 3 (d) .Digital Panel Meters Class 1with 3 Phase Voltage, Current Frequency, PF, KW,KVA,KVAR and kWh Make C&S Model CSM-A-M4-S3 - 1 No (e) Aluminium Busbar 1500 Amp - 1 set of 4 complete wiring of panel & Installation all as specified
Supply and install, testing and commissioning of LT panel board outdoor cubicle type floor mounted metal enclosed fixed type,free standing,floor mounting,compartmentalized,modular type suitable for indoor installation,cubical type,factory assembled in bolted design fabricated from 3.15 mm thick CRCA sheet steel frame work and painted with two coat of synthetic enameled paint, degree of protection IP-54 as per IS-13947,consisting high conductivity bus aluminium bus bar of suitable size with heat shrinkable sleeves,fault rating 50 kA for 1 sec, including multifunctional digital voltmeter,ammeter,frequency meter and power factor meter,The drawing of the LT Panel board will be approved by Engr-in-Charge and the same have the following electric controls :- (LTP at P-345) (a) MCCB 4 Pole 250 A,36 kA, 415 V - 1 Nos.(I/C) (b) MCCB 40 Amp, 25 kA,4 Pole - 6 Nos.(O/G ) (c) CTs 500/ 5 ma - 1 Set of 3 (d) .Digital Panel Meters Class 1with 3 Phase Voltage, Current Frequency, PF, KW,KVA,KVAR and kWh Make C&S Model CSM-A-M4-S3 - 1 No (e) Aluminium Busbar 350 Amp - 1 set of 4 complete wiring of panel & Installation all as specified
Supply and install, testing and commissioning of LT panel board outdoor cubicle type floor mounted metal enclosed fixed type,free standing,floor mounting,compartmentalized,modular type suitable for indoor installation,cubical type,factory assembled in bolted design fabricated from 3.15 mm thick CRCA sheet steel frame work and painted with two coat of synthetic enameled paint, degree of protection IP-54 as per IS-13947,consisting high conductivity bus aluminium bus bar of suitable size with heat shrinkable sleeves,fault rating 50 kA for 1 sec, including multifunctional digital voltmeter,ammeter,frequency meter and power factor meter,The drawing of the LT Panel board will be approved by Engr-in-Charge and the same have the following electric controls :- ( Distribution panel at P-342) (a) MCCB 4 Pole 500A,50 kA, 415 V - 1 Nos.(I/C) (b) MCCB 160 Amp, 36kA,4 Pole - 1 Nos.(O/G ) (c) MCCB 100 Amp, 36kA,4 Pole - 2 Nos.(O/G ) (d) CTs 500/ 5 ma - 1 Set of 3 (e) .Digital Panel Meters Class 1with 3 Phase Voltage, Current Frequency, PF, KW,KVA,KVAR and kWh Make C&S Model CSM-A-M4-S3 - 1 No (f) Aluminium Busbar of size 500A - 1 set of 4 complete wiring of panel & Installation all as specified
Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross sectional area as under : (a) 10 Sq mm 4 core
(b) 70 Sqmm 3.5 core
(c) 300 Sqmm 3.5 core
Excavation in trenches, n.exc 1.5m wide & n.exc 1.5m in depth for foundation & getting out in for laying of cable complete as specified.
Removal of surplus soil to a distance not exceeding 50 mtr away and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cms thick in soils complete all as specified
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed.Note- Punned down thickness will be measured for payment purpose.
Supply and laying un reinforced precast concrete cable covers LV Type 2, flat, size 300mm x 180mmx 40mm complete all as specified and directed.
Earthing complete with Galvanised Steel earth plate of size 60x60cmx6.0mm thick electrode and 32x6mm GI strip as earth lead, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below ground level, connected to 32x6mm earth strip(drawn through 40mm dia light grade GI pipe in ground) by means of nuts, bolts, check nuts and washers of GI all as shown in electrical plate No.5 of SSR Part-I duly connected to Panel / DB / main switch all as specified or as indicated including testing on completion (Rates inclusive of neccessary excavation, earth work, PCC pit, CI cover, funnel with 20mm dia medium grade GI watering pipe, suitable size of light grade GI Protection pipe for earth strip in ground etc. all as required at site for complete earthing).
Boring of holes under road not less then 0.6mtr depth and 90mm dia hole by trenchless mannual boring by using augar and laying of necessary GI pipe of suitable dia including jointing and cable pulling all as specified.
M&L GI pipe 80mm dia light grade with all fittings, MS clamps fixed on poles or laid in floors for protection of cable all as directed.
M&L GI pipe 50mm dia light grade with all fittings, MS clamps fixed on wall or laid in floors for protection of cable all as directed.
Demolition of Laid dry and pointed Stone slabs and tiles of any description or thickness in floors, aprons etc.
Demolition Cement concrete (unreinforced) Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level)
M&L Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out Hard/dense soil
M&L Cement concrete in foundations, filling and mass concrete Type C2 1:3:6 (40mm graded aggregates)
M&L Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar, complete Set in cement mortar 1:4 Type B1 1:2:4
M&L Rendering 10mm thick on fair faces of brick work or concrete sur?faceCement plaster 1:4
M&L Providing, cement concrete in roof kerbs or mud stops, rounded or chamfered on edges in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed Type B1 1:2:4 (20 mm graded aggregate)
M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size
S&F wiring for circuit/Sub main wiring along with earth wire with 2x4.0 sq. mm + 1x4 sqmm of FR PVC insulated copper multi stranded conductor single core cable drawing through PVC casing and caping of adiquate size complete all as specified (Note:- 3 lengths of 4 Sqmm cable, with PVC Conduit will be measured as one length).
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 230 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
S&F MCB TPN 40 Amps C curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge. Make:-Indoasian/Anchor/Legrand/ABB
S&F MCB SPN 16 amp C curves MCB repturing capacity 10 KA etc complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed
Supplying and fixing smart single phase two wire dual source prepaid energy meters BIS 15884 marked in existing meter board / florr panels with pre payment capacity touch keypad based digital having current range 10-60 Amp 240 Volt accuracy class 1.0 alongwith parallel home display split unit with inbuilt load control switch containing provision for TOD and RTC, inbuiltfeature to sense the DG mode through PLSI, dual source registration wrt grid as well as DG supply and dynamic load allocation facility from grid and DG, capable to define for tariff slabs, happy hours and holiday definition. Note:- The meters shall be connected with the existing gate way held with this office with the quoted rate.
M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates) for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I and testing on completion.
M/S HARIOM CONSTRUCTION COMPANY
Aggarwal brothers and company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .