| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC L1 | |
| 2 | L2₹3.1 L+₹15,371 (5.21%)Rejected-AOC C 23 CC | L2 | Rejected-AOC L2 | |
| 3 | L3₹3.3 L+₹33,196 (11.3%)Rejected-AOC 0 AJAY KUMAR 85 HASTAM HASTAM BANDA UTTAR PRADESH 210001 HASTAM BANDA UTTAR PRADESH 210001 UDYAM UP 13 0007628 | BANDA | UTTAR PRADESH | 210001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹3.4 L+₹49,020 (16.6%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹3.7 L+₹75,058 (25.5%)Rejected-AOC 67 NIRANJANPUR SAHARANPUR ROAD PO MAJRA DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC L5 |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
25 Jul 2020, 6:00 pmClosed
Prashant Kumar Gaur AE
AGE(I) Raiwala
REPAIR AND REPLACEMENT OF CERTAIN ELECT WIRING FITTING AND FIXTURES UNDER ZONE A AT MILY STN RAIWALA
2020_MES_360543_1
8819/E8
Open Tender
Civil Works
Item Rate
180 days
Raiwala
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Raiwala
₹10,000
Yes
15 Oct 2020
13 Jul 2020
27 Jul 2020
13 Jul 2020
25 Jul 2020
18 Jul 2020
Amount
Taking down carefully point wiring copper/ aluminium (light, fan, socket, power) complete including switches, ceiling roses , pendants, regulators , sockets etc and removing materials to store and making good the disturbed surfaces of walls, floors etc Complete all as specified & directed.
Taking down service /sub main wire of any size fixed in any position , complete all as specified and directed.
M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor of size 1.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked, 20 mm or higher dia complete with all accessories/fittings and sunkan MS boxes of thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, complete all as specified & directed for the following.
One light /fan /bell /exhaust fan point controlled by one , one way 5/6 switch.
One 5 pin 5/6 Amps socket outlet point on independent board controlled by one, oneway switch single pole 5/6Amps
All as per item No 5 above but on the same board with other switches /socket.
One light point controlled by two 2-way switches 5/6 Amps
M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor of size 2.5 sqmm (nominal cross sectional area ) single core cable in and including rigid non metalic PVC conduit 20 mm dia or higher size "medium " grade ISI marked concealed (surface only on roof & colomns) complete with all accessories/fittings and MS box thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, for one three /six pin 15/16 amps power socket controlled by one 15/16 amps switch complete all as specified & directed.
S &F switch piano flush type white /ivory finish 5/6 Amps, single pole one way complete all as specified & directed.
All as per item No 9 above but 2 way switches.
S & F switch piano flush type white /ivory finish 15/16 Amps single pole one way.
S &F socket out let 2 pin 5/6 Amps & 3 pin 5/6 Amps flush type.
All as per item No 12 above but 3 pin 5/6 Amps & 3 pin 15/16 Amp.
S & F lamp holder, straight or angle , metal cases body of brass with back plate suitable for batten fittings complete including 01 x 09 watt LED all as specified & directed. Make :-Havells/C&S/Bajaj/Philps.
S & F ceiling rose surface Bakelite AC 220/240 volts 3 terminals complete all as specified & directed.
S & F bell push AC, SP 240 volts flush type 5/6 Amps complete all as specified and directed.
S & F bell electronic AC, SP 240 volts complete including rectangular first class hard wood board of size 150 mm x 100mm x 50mm complete all as specified and directed.
CFL light fitting 1 x 9 watt bulk head luminaries, with lamp holders, etc complete with all acessories and incl connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ. (incl 1 x 9 watt CFL) all as specified and directed.Make :- Havells/C&S/Bajaj/Philps.
Supply and fixing wall light fittings and fixture made up of poiycarbonate with 14 watt LED. Make :- Havells/C&S/Bajaj/Philps.
Supply and fixing LED tube light fittings 1x20 watt, IP rating 20,power consumption 20 Watt,operating voltage 90- 270 Volts AC,color temperature coolwhite/coolday light complete with pre-wired accessories, fixed to wall,including three core 23/0.0076 size coper flexible wire from ceiling rose to fitting complete all as specified and directed. Make :- Havells/C&S/Bajaj/Philps.
S&F fan regulator , fulsh stapped type ,electronic ,450 watt complete all as specified and directed
S&F MCB, single pole 240 Volts 5 to 30 Amps complete all as specified & directed..
S&F Isolator single pole and neutral 240 Volts 40 Amps complete all as specified & directed.
S & F sheet metail enclosure for DB , four way , double door type, SPN, with 200 Amps rated bus bar , 240 Volts suitable for housing MCBs and isolator and making niche, replastring to match with existing surface etc complete all as specified & directed.
S& F sheet metail enclosure for DB , eight way , SPN, with 200 Amps bus bar , 240 Volts suitable for housing MCBs and isolator and making niche,replastring to match with existing surface etc complete all as specified & directed.
M & L for sub main wiring with two run of 4 Sqmm (nominal cross sectional area ) of single core unsheathed PVC insulated cables 1100 Volts grade multi stranded copper conductor drawn through & including non metallic rigid PVC conduit of size 19/20 mm or higher dia with & including necessary conduit accessories concealed/surface only on roof & colomn) type including 2.5 Sqmm stranded copper conductor PVC insulated cable as earth wire connected to common earth dolly complete all as specified & directed by.
M& L for earthling complete with galvanized steel earth plate, electrode 600 x 600x6 mm thick , buried directly under ground (earth pit not less than 2.25 m below ground level ) with top edge of the plate not less than 1.5 below ground level connected to galvanized earth wire 4.0 mm dia by means of nuts, bolts, check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No 5 connected to main switch board, including all necessary excavation & earth work in hard/dense soil, common salf and charcoal dust mixed & packed 150 mm thick homogeneous layer all around the GI earth plate, earth pit chamber made out of cast iron frame with hinged door , GI protection pipe light grade upto 7.5 meter from electrode complete all as specified & shown on drawings with watering pipe .
Note :- (1) Earth lead and GI pipe light grade 15 mm dia for protection against mechanical damage beyond 7.5 mtr from electrode to earth terminal point/main switch board. Etc shall be measured separately .
(2) On testing, after completion of Job , if desired earth resistance is not obtained , the earthing shall be redone at no extra cost to contractor.
S&F isolator tripple pole and neutral 415 Volts 63 Amps complete all as specified & directed.
RAMAN CONSTRUCTION CO.
AJAY KUMAR CONTRACTOR
janta tradrers
Bedi Refrigeration Works
TARUN ENGINEERING WORKS
DIVINE ENGINEERING
AMAR NATH SHARMA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .