Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC | L1 | Accepted-AOC AOC ACCEPTED | |
| 2 | L2₹12.5 L+₹2.0 L (19.6%)Rejected-AOC | L2 | Rejected-AOC AOC NOT ACCEPTED | |
| 3 | L3₹12.5 L+₹2.0 L (19.6%)Rejected-AOC GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L3 | Rejected-AOC AOC NOT ACCEPTED | |
| 4 | L4₹12.6 L+₹2.2 L (21.1%)Rejected-AOC | L4 | Rejected-AOC AOC NOT ACCEPTED |
Tender Value
Refer Docs
EMD Value
₹20,800
Closing Date
10 Oct 2020, 6:00 pmClosed
GE RAMGARH CANTT
GE RAMGARH CANTT JHARKHAND PIN 829122
Provn of certain MINOR WORKS of Aluminium Partition in Bldg T-1 GE Office, Provn of 12 x exhaust fans and 22 x wall mounted fans in Bldg No. T-15 (MW), T-16 (ICU), T-22 (ACW) and T-50 (FW), Provn of 01 x soakage Well for Bldg No. T-23 (IW) at MH, Pro
2020_MES_374502_1
8300/2089/E8
Open Tender
Civil Works
Item Rate
120 days
GE RAMGARH
CLASS E Cat a i and b i
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹20,800
Yes
7 Dec 2020
4 Sept 2020
12 Oct 2020
4 Sept 2020
10 Oct 2020
26 Sept 2020
Amount
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and as directed.(6+102+45+43+45)
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, manholes,etc and getting out, and getting out in soft/loose soil, complete all as directed.
Returning, filling in trenches including spreading, levelling watering and well ramming in layers n.exc 25 cm thick, complete all as specified and as directed. (6+6)
Removing excavated materials exc 250 m and n.exc 500 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed. (2.5+6.45)
M & L for PCC (1:4:8) type D2 40mm graded stone aggregate as in foundation, sub base, filling and mass concrete etc., Complete all as specified. (0.68+0.90+3.23)
M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:6), complete all as specified and as directed. (4.8+5+0.35+1)
Cutting out bricks,forming toothing for, and bonding new into old work in cement mortar including value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only), complete all as specified and as directed.
M & L for Damp proof course to horizontal or vertical surfaces including necessary formwork in PCC (1:2:4) type B-0, 50mm thick mixed with WPC @ 3% by weight of cement, complete all as specified and as directed. (Note: WPC shall be measured and paid separately)
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in, lintel beam, roof beam, cantilever, bressumers etc., supported on walls, beams, columns and the like, complete all as specified and as directed.
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in slab supported on walls beams and columns, floor, roofs, landings, balconies, canopies, deck slabs and shelves, etc., complete all as specified and as directed.
M & L for RCC(1:1.5:3) type A-1 using 20mm graded stone aggregate as in Chajja supported on walls beams and columns, floor, roofs, landings, balconies, canopies, deck slabs and shelves, etc., complete all as specified and as directed.
M & L for formwork to soffit of suspended slab (flat) such as roof slab, floor slabs n.exc 200mm thick (horizontal or sloping), complete all as specified and as directed. (3.75+5.50)
M & L for formwork to concrete flats, breaks in floor, openings in concrete walls, floor and roofs an sides of RCC/PCC bands in wall, horizontal or sloping, and similar work all exceeding 20cm wide, complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, widow cills, concrete railings, opening in concrete walls, floor and roofs etc, exc 10cm but n.exc 20 cm, and sides of RCC/PCC bands in walls, horizontal or sloping and simimilar works, complete all as specified and as directed.(8.5+37)
M & L for formwork to chullah hoods, chajjas, troughs and similar items including edges, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed. (45+150)
S & F mild steel TMT bars 8mm dia and over cut to length, bent to shape required including cranking bending with MS wire (annealed) not less than 0.90mm dia or securing with clips as in stirrups, complete all as specified.
M & L 10mm thick cement plastering in cement mortar (1:3) on fair faces of concrete surfaces finished even and smooth using extra cement neeru finished to plastering, complete all as specified and as directed.
M & L for rendering 15mm thick brickwork or concrete in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and as directed. (16+8+60)
M & L for plastering10mm thick on fair faces of brickwork or concrete in cement mortar (1:6) finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for rendering in cement mortar (1:3) on fair faces of cement concrete surfaces, ceiling, chajjas etc., of thickness 5mm finished the surface even and smooth without using extra cement, complete all as specified and as directed.
M & L for preparation of newly plastered surfaces using sand paper and applying two coats of cement base paint over a coat of cement base primer, complete all as specified and as directed. (16+3)
M & L preparation of new plastered surfaces of walls and applying three coats of white wash complete all as specified and directed. (10+5+60)
M & L preparation of new plastered surfaces of ceiling, chajja, fascia and applying three coats of white wash complete all as specified and directed.
M & L for 100 mm thick D2(1:4:8) 40mm graded aggregate as in sub base floor, complete all as specified and as directed. (2.5+102+50)
M & L for 75 mm thick plain cement concrete (1:3:6) mix, type C-1 using 20mm graded stone aggregate as in plinth protection, finishing the surfaces even and fair without using extra cement, including 10 mm wide groove not exc. 3.00 m in length and filled with bitumastic, complete all as specified and directed.
Hardcore of broken bricks of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rammed to a true surface, complete all as specified and as directed. (0.60+10+4.30)
M & L for 25 mm thick B1(1:2:4) using 20mm graded aggregate as in sub base floor, finishing even and smooth without using extra cement, complete all as specified and as directed.
M & L for 15mm thick screed bed in cement mortar 1:6, complete all as specified and directed
M & L for 10mm bedding layer in cement mortar (1:4) , complete all as specified and directed
M & L for non skid ceramic paver tiles of size 300x300x10 mm thick, coloured as in path etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified and as directed.
M & L for glazed ceramic coloured tiles 300x200X 7 mm thick as on vertical surface of wall such as skirting, dado, riser etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface of tile, complete all as specified and directed.
M & L for solid PVC door frame of size 50mm x 47 mm made out of 5m plain colour PVC sheet reinforced with MS square tube, fixing in opening, complete all as specified and as directed.
M&L for factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rain on either side and as gap insert for top rail and bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading, and jointed together with solvent cement fixing with the frame at site as per manufacturerer's instructions, complete all as specified and directed.
S & F steel ventilator with top hung shutter including hinges, steel peg stay complete all as specified and as directed.
S & F framed work such as grill, grating, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; conforming to Fe-410-0 or Fe 310-0, complete all as spd and directed by Engr-In-Charge .
M & L in applying two coats of synthetic enamel paints over a coat of red oxide primer on steel surfaces over 10cm width or girth including preparation of surfaces, complete all as specified and as directed by Engr-in-Charge. (0.40+13.50+18+15)
M & L for 3mm thick figured glass quality and glazing with oil putty n.exc 0.50 Sqm in each pane complete all as spd and directed by Engr-In-Charge .
S & F Aluminium anodised door stopper with rubber shoes of size min 50mm long, complete all as specified and as directed.
S & F Aluminium, anodised barrel tower bolts 200mm of extruded section, complete all as specified and as directed
S & F mild steel butt hinges 100 mm medium weight cooled roll, complete all as specified and as directed
S & F 200mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips to sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, complete all as specified and directed
S & F 150mm long, aluminium handles cast type, complete all as specified and as directed.
M & L for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in holdfast , complete all as specified and directed. (0.06+2)
S & F in repair rotational moulded polythene water storage tanks, double layered (cylindrical vertical with closed top) of capacity 300 lit, hoisted and fixed in position , complete all as specified and asd directed.
S & F PVC ball valves 20mm with epoxy coated aluminium rod and high density (min weight 210 gms) , complete all as specified and directed.
M & L for plain cement concrete 1:3:6 type C-2, using 40 mm graded stone aggregate as in base of PVC water tank including necessary formwork, complete all as specified and directed.
S & F for GI tubing medium grade including all types of fittings of ISI marked fixed to walls and ceiling or laid in floor suitable for 15 mm bore, complete all as specified and as directed.
S & F for GI tubing medium grade including all types of fittings of ISI marked fixed to walls and ceiling or laid in floor suitable for 20 mm bore, complete all as specified and as directed.
M & L gun metal, globe or gate valves 20mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
M & L gun metal, globe or gate valves 15mm dia with iron wheel head, screwed both ends for iron pipe and fixed, complete all as specified and as directed.
S & F stop valve, cast copper alloy screwed down high pressure with crutch fly handle screwed both ends for iron pipe of bore 15mm fixed, etc., complete all as specified and as directed.
S & F PVC connection 15 mm size with PTMT nuts of length 450, complete all as specified and as directed.
S & F bib tap, cast copper alloy chromium plated (CP) with capstan head handle screwed down screwed for iron pipe and fixed to 15mm bore pipe, complete all as specified and as directed.
S & F vitreous China urinal, half stall type (back to corner wall type) including providing and fixing plug, bedding urinal against wall in cement mortar (1:2) securing urinal to plug with and including 60 mm brass long screw, pointing around urinal back in cement mortar, flush pipe, waste pipe, waste fittings, grating and union for discharge, complete all as specified and as directed.
S & F vitreous China wash basin, white, flat back, size 550X400mm including cast iron brackets for fixing, 32mm waste coupling, 32mm waste pipe etc,. including PCC 1:2:4 type B1 using graded stone aggregate for embedding brackets and making disturbed surfaces in cement mortar (1:3), complete all as specified and directed.Make:- Hindware/Parryware/Cera or of equivalent approved make.
S & F pillar tap fancy type, cast copper alloy with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe of dia 15mm and fixed, complete all as specified and as directed.
S & F flushing cistern low level, PVC 10 lit capacity syphon action type, valveless with inlet ball valve, float valve, handle including bracket and 32mm flush pipe, and making good disturbed surfaces in cement mortar (1:3), complete all as specified and as directed.
Supply and fix sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and directed
M & L for vitreous china wash down water closet, pedestal pattern Pedestal pan and trap, including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc.and including seat and cover for pedestal pan as in repairs complete all as specified and directed.
S & F brass chromium plated tubular towel rail, 20mm dia, D type, 60 cm long between flanges, complete all as specified and as directed.
M & L PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
M & L PVC (SWR) pipes 110 mm bore, single socketed in any length with rubber ring joints laid in trenches or in floor, complete all as specified and directed.
M & L PVC (SWR) pipes 75 mm bore, single socketed in any length with rubber ring joints laid in trenches or in floor, complete all as specified and directed.
S & F (SWR) 110 mm dia bends any radius with rubber ring joints, complete all as specified and directed.
S & F (SWR) 75 mm dia bends any radius with rubber ring joints, complete all as specified and directed.
S & F (SWR) 110 mm bore junction, (double Tee) equal or unequal, complete all as specified and directed.
S & F (SWR) 75 mm bore junction, (double Tee) equal or unequal, complete all as specified and directed.
S & F (SWR) 110 vent cowl, complete all as specified and directed.
M & L for loose filling with broken bricks aggregate of gauge 80 to 100 mm in soakage pits, soakage well, complete all as specified and as directed. (0.8+5)
Surface dressing n.exc 15cm deep and getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas, n.exc 1.5 m deep and getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas, exc 1.5 m but n.exc 3.00 m deep and getting out in soft/loose soil, complete all as specified and as directed.
Excavation over areas, exc 3.0 m but n.exc 4.50 m deep and getting out in soft/loose soil, complete all as specified and as directed.
M & L for RCC nominal mix 1:2:4 type B1 (using 20mm graded aggregate) as in foundations, including rafts, footings, foundation beams, plinth beams, bases for columns, etc., basement slabs, under reamed piles and mass concrete, complete all as specified and as directed.
M & L for RCC nominal mix (using 20mm graded stone aggregate) 1:2:4 type B1 for slab supported on walls, beam and columns in floors, roofs landings, balconies, canopies, deck slab and in shelves, complete all as specified and as directed.
M & L for brick work with sub class 'B' bricks in one brick thick wall honey comb walling built in cement mortar 1:4, complete all as specified and directed.
M & L for brick work with sub class 'B' bricks in one and half brick thick wall honey comb walling built in cement mortar 1:4, complete all as specified and directed.
Removing excavated materials to a distance n.exc 50 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed. (6.75+6.75+20+28)
M & L for concrete bed to drain pipes including packing under, and hunching against the sides of pipes after they are laid and tested in cement mortar 1:3:6 type C-2, using 40 mm graded stone aggregate for 150mm pipe, complete all as specified and directed.
M & L PVC (SWR) pipes 150 mm bore, single socketed in any length with rubber ring joints laid in trenches or floors, complete all as specified and directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm dia pipe, complete all as specified and as directed.
S&F Anodised aluminium frame for doors, windows, ventilators for two/three track channel including joining cleat,rubber packing etc, complete all as specified by Engr-in-Charge.
Anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and as directed.
S & F anodised aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified and directed.
M & L 12 mm thick prelaminated particle board exterior grade prelaminated both side with decorative choice lamination fixed in aluminium shutter/partition, complete all as specified and directed by Engr-In-Charge .
M & L for 5.5 mm thick plain sheet glass quality n.exc 0.50 Sqm in each pane, complete all as specified and directed by Engr-In-Charge .
M & L for 5.5 mm thick plain sheet glass quality exc 0.50 Sqm in each pane complete all as specified and directed by Engr-In-Charge .
M & L for hydraulic door closer, regulated, designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed, complete all as specified and as directed.
Taking down chowkhats with shutter or frames of any description exc 1.5 Sqm and n.exc 4 Sqm each (without taking of shutter from the frame), complete all as specified and directed by Engr-In-Charge .
Taking down chowkhats with shutter or frames of any description n.exc 1.5 Sqm each (without taking of shutter from the frame), complete all as specified and directed by Engr-In-Charge .
Demolition of brick work built in cement mortar including all quoins, arches, pillar etc., complete all as specified and directed
Demolition of galvanised steel barbed wire, mild steel wire 4mm dia from angle iron post, complete all as directed.
Dismantling of mild steel work or wrought iron of any description, complete all as directed.
Demolition of cement concrete in ground floors & paving n.exc 15cm thickness (below or above ground level) complete all as directed by Engr-in-Charge
M & L for formwork to faces of wall, abutments, parapets and staircase railing and similar work including attached pillasters, buttresses, etc., vertical or to batter , complete all as specified and as directed.
S & F for galvanised 2 strand steel barbed wire 2.24 mm dia barbed with 2mm dia at 75 mm spacing and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossing with and provision of galvanised mild steel wire, staples or steel pins, etc., complete all as specified and as directed.
S & F mild steel work including necessary drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps inlcluding embedding in concrete and screwing etc., wind ties for roof including securing bolts, posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc, flat iron fillets (for securing wire mesh etc.,) including all necessary drilling, bolting or rivetting, etc., and similar work conforming to Fe 290 grade E-195 complete all as specfied and as directed.
S & F concertina coils 600mm dia having 50 Nos of turns in each coil weighting approx 8.5 Kg/Coil fabricated from PBT (R) of specification as indicated below extendable upto a length of 6 metres enabling adjacent coils to be jointed by special galvanized steel clips in order to form a long stretch of continuous barrier complete. Specification for RBT (R) : Reinforced punched Barb Tape in coils of approx weitht 8.5 Kg/coil and length 100m (approx) PRT (R) with continuous punched barbs at an interval of 24mm approx on both sides of cold rolled low carbon steel tape 19(+/-) 2mm wide conforming to IS : 228 and electro galvanized to IS : 1573-1960. The blade edged barb tape is mechanically clenched on to 12 SWG (2.6mm) high tensile wire conforming to IS:4454 Part Grade-II and hot dip galvanized according to IS-2629 having load bearing capacity of 800-900 Kgs and it is coated with anti corrosive bitumen paint for maximum corrosion both sides resistance and durability and also providing camouflage effect complete all as specified and directed.
Taking down cement plaster of any description and in any position including raking out joints, hacking for key scrubbing down with water etc and removing of debris from site, complete all as directed.
M & L for 50 mm thick concrete (1:2:4) type B-1 using (20 mm graded crushed stone aggregate) as in hardstanding finishing cement concrete surface even and smooth without using extra cement in alternate panels, complete all as specified and directed.
M & L for forming contraction (Dummy) joints 65mm deep x 10 mm wide, filled with sealing compound grade 'A', complete all as specified and as directed.
M & L for forming contruction joints 30mm deep x 10 mm wide, filled with sealing compound grade 'A', complete all as specified and as directed.
Excavation in post holes in any kind of soil (or similar holes) each n.exc. 0.5 Cum getting out, returning, filling in and ramming earth around, in layers n.exc 25cm etc., complete all as directed. (6+6)
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws, complete all as specified and directed. (41+41)
M & L for PCC (1:2:4) type B2 (using 40mm graded stone aggregate) as in foundation filling mass concrete including use and waste of formwork, complete all as specified and as directed. (1.2+1.1)
M & L for roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc., and welding counter sunk for holes and necessary gusset plates etc and similar work conforming to Fe-410W (Gde E-250 quality A) complete all as specified and directed by Engr-in-Charge.(350+330)
M & L for brick work with sub class 'B' bricks of class designation 10 all as per IS-1077-1992 (minimum compressive strength of brick 100 Kg/Sqcm) old size bricks, straight or curved on plan exceeding 6m mean radius built in CM (1:4), complete all as specified and as directed.
M & L for plastering 15mm thick on fair faces of brickwork or concrete in cement mortar (1:4) finished even and smooth without using extra cement, complete all as specified and as directed.
M & L for 10mm thick light/dark coloured vitrified paver tiles in floors n.exc 0.11 Sqm set and jointed in neat cement slurry and pointed in coloured cement to match the shade over and including 20mm thick screed bed in cement mortar (1:4), complete all as specified and as directed.
M & L for cement concrete type B1, 1:2:4 (using 12.5 mm graded aggregate) in levelling courses, coping, window cill etc., complete all as specified and directed.
Roughening surface of old concrete floor by picking, sweeping washing down with water to remove dust etc., and brushing neat cement slurry with 3 Kg of cement per square metre, complete all as specified and as directed.
M & L for 20 mm thick screed bed in cement mortar 1:4, complete all as specified and directed
M & L for machine cut Kota stone slab flooring, 20-25 mm thick over cement screed base laid and jointed with grey cement with colour pigment to match the shade of the stone slab including rubbing and polishing, complete all as specified and as directed.
Labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform and other similar situations, complete all as directed.
M & L for aluminium strip 25x3.15 mm with saddles, DNB insulator and fixing screws etc., for roof conductors and down condutors, complete all as directed.
S & F thermoplastic cable junction box IP-66 halogen free and weather proof with terminals suitable for 10 Sq mm dimension 167mm x 125 mm x 82 mm (CAT part No. KF 5105, of Make Hensel) or its equivalent as approved, complete with all fixing accessories including testing all as specified and as directed.
Earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m below normal ground level) with top edge earth plate not less than 1.5m below GL using galvanised iron strip 32×6mm as earthing lead to earth plate electrode by means of nuts, bolts and washers made of galvanized iron or steel earth wire protected by 15 mm bore light grade GI pipe and connected for body earthing of feeder pillar box all as specified with & including PCC (1:3:6) type C1 pit and precast RCC (1:2:4) type B1, cover Cast iron of size 300x300x10mm, with handle GI funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal and salt in alternate layer including necessary earth work on any type of soil and removal etc, complete all as specified and shown in electrical plate No 5 of SSR Part I and as directed.
M & L for Air termination, single pointed aluminium rod 12mm dia and 300 mm long, complete all as specified and directed.
M & L for point wiring for one light/ fan point/call bell controlled by one switch with 1100 volt grade PVC insulated FRLS 1.5 Sq mm multi stranded copper conductor cable with continuous earth wire of 1.5 Sq mm multi stranded copper conductor cable PVC insulated-unsheathed, drawn in & including concealed rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia & sunken anodized pressed sunken boxes made out of not less than 1.0 mm thick sheet, covered with 2.8 mm thick laminated insulated cover make sheet for housing/fixing switches etc complete all as specified and directed.
All as per item No. 122 here-in-before but 1.5 Sqmm for 5 Amp socket outlet on the same board with 1.5 Sq mm earth wire.
S & F for switch piano type 5 amp 230 volt one way flush type, complete all as specified and as directed.
S & F ceiling rose three terminals PVC/ Polycarbonate, isolated body complete all as specified.
S & F socket outlet 3/5pin 5 Amp flush type 230 volt complete all as specified.
S & F metallic exhaust fan along with louvers single phase 230v, of 300 mm sweep BEE 5 star, with necessary fixing clamps, hook and nut, bolt and washers on wall, complete all as specified and as directed. Make: Crompton Greaves/Havells/Bajaj or its equivalent as approved.
S & F wall mounted fan single phase 230V, of 400 mm sweep BEE five star including connecting up with 3 core multi-stranded copper conductor cable of size 23/0.193 from ceiling rose/socket outlet, complete all as specified and as directed.
Supply only water proofing compound
M/S BIJAY KUMAR SINGH
M/s Ray construction
upadhyay engineers and consultant
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .