Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹21.6 L+₹4.2 L (24.3%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹23.9 L+₹6.5 L (37.5%)Rejected-Finance MAHAMUNI PARA BOGAFA P S P O SANTIRBAZAR SOUTH TRIPURA | GOMATI | TRIPURA | 799125 | L3 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20.7 L
EMD Value
₹41,400
Closing Date
11 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chiloda
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
REPAIR AND MAINTENANCE OF HT LT NET WORK AND OTHER ASSOCIATED WORKS AT MALHAR CAMP AREA AT AFS BARODA
2023_MES_574304_1
82124/BRD/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
GE (AF) Baroda
As per tender document
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Baroda
₹41,400
Yes
23 Feb 2023
11 Jan 2023
18 Feb 2023
11 Jan 2023
11 Feb 2023
30 Jan 2023
12 Jan 2023 - 25 Jan 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
M&L Dry sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Removal of excavated material at a distance not exc 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point in soft / loose soil complete all as directed.
Supply and spreading of aggregate of size 40 mm graded stone aggregate on surface with 10 cm depth inside pole mounted Sub Station complete all as specified and directed by engineer in charge.
M & L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) for foundation of the pole complete all as specified and directed.
M & L PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) for coping of the pole including necessary form work complete all as specified and directed.
M&L PCC 1:2:4 type B1 using 20mm graded stone aggregate oft any description in any position including necessary form work complete after demolition of existing unserviceable PCC all as specified and directed.
S & F Chain link MS galvanised fencing of 3mm dia of wire each way and 50mm mesh size including 10mm dia MS round bar as in line wires ,straining bolts, 40mmx6mm flat iron etc. including provision of binding wire etc complete as in repairs all as specified
S&F Framed work as in door or gate of angle or other section with gusset plates, rail, braces etc complete drilled for fixing of steel sheeting or other covering doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fitting also fastening and fixing complete conforming to Fe-410-0 or Fe-310-0 as in repairs all as specified.
S&F Cross arms, bracing, supports, clamps and back plates fabricated from structural steel sections including nuts & bolts , washers , welding bending cold or hot , drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of red oxide primer complete as in repairs all as specified and directed by Engineer-in-Charge.
S&F Pin type porcelain, vitreous, white, brown or green insulators, including one galvanized mild steel spindle two galvanised iron washers and one galvanised iron nut, 150mm height and 150mm dia suitable for working pressure upto and including 11000 volts grade for HT lines fixed on polescomplete as in repairs all as specified
S&F Disc type insulator, porcelain, vitreous 150 mm height and 150 mm dia ball and socket type white/brown or green two in series assembly for tension with tension clamps for conductors working pressure 11000 volts grade for HT lines fixed on poles complete as in repairs all as specified .
M&L Stay assembly for HT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod , having 7 / 3.15mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator, shackle & stay clamps, necessary excavation and earth work in any type of soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge including taking out and dismantling old unserviceable stay assembly.
S&F Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal RED colur and fixed with MS clamps bolts and nuts of approved size for HT 25x20 cm size complete as in repairs all as specified
Supply , jointing and testing cable jointing kit for 11 KV(Earthed) grade cable for indoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured at cable of size 95 sqmm to 150sqmm as in repairs all as specified
Supply , jointing and testing cable jointing kit of 11 KV grade cable for outdoor termination, heat shrink type complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm to 150 Sq mm, as in repairs all as specified.
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 300mm x 180mm x 40mm, factory made, complete as in repairs all as specified
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class lV, type I, size 250mm x 150mm x 40mm, factory made, complete as in repairs all as specified
Supply , jointing and testing cable jointing kit for 11 KV(Earthed) grade cable for straight through heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured at cable of size 95 sqmm to 150 sqmm as in repairs all as specified Note : (i) Rate quoted shall be deemed to be inclusive of necessary excavation/ filling making good the existing surfaces with the necessary T&P as required all as directed by the Engineer-in-Charge.
Supply ,laying, jointing and testing 11 KV (Earthed), aluminum conductor, screened, XLPE insulated, armoured shielded and PVC sheathed cables conforming to IS 7098 (Part-II) amended upto date having cross sectional area 95 Sqmm 3 core as in repairs all as specified
Supply, erecting and fixing in true vertical position, steel tubular swaged pole (410 SP – 55), 11 mtr long, complete with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally upto planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete including dismantling of unserviceable steel poles /struts, any size all as specified Note :- Earth work, PCC in foundation and coping, cross arms, danger notice board and anti climbing device shall be measured and paid separately
M&L Welding repair work to existing LT panel including required lines and iron parts as per requirement including two coats of synthetic enamel paint over a coat of red oxide primer over new steel surfaces complete all as specified
Trimming for branches of trees, bushes, herbs 10 Mtr surrounding of 4 pole/ 2 pole/ structure /sub station including removal of tree branches etc to a distance not exceeding 50 mtr from over head line all as specified and directed.
M&L Cutting chasing in hard standing road/path/drain making holes in concrete wall etc for passing through of cable and making good as per existing by using PCC (1:3:6) type C-2 using 40 mm graded stone aggregate all as specified and directed.
S&F Cable route Indicator made out of 150 mm round disc of cast iron duly written with HT/11 KV cable properly fixed with nut bolts to angle iron 40X40X5 mm length 60 cms properly grouted in ground at a depth 25 cms with PCC 1:2:4 type B1 using 20 mm graded stone aggregate Size 10X10X10 cm underground, including necessary excavation earthwork complete. Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete as in repairs all as specified and directed.
M&L Servicing and maintenance of HT VCB 11000 Volt 400 Amp of any make and type at existing site including opening /drawing out the VCB trolley after switching off electric supply testing and maintenance of VCB panel complete with following:- (i) Checking of all mechanical/electrical control systems for proper functioning including spring charging system, tripping system, indication system, vacuum interrupter; cleaning & servicing the fixed/moving contacts & blowing out dust and applying the proper lubrication/greasing complete, (ii) checking of Contact Resistance (RYB) and Auxiliary Supply voltage of closing coil, tripping coil, Motor; cleaning & servicing for proper functioning (iii) Timing Test of closing time and opening time, IR value with 5 KV meagre before and after HV, (iv) Checking of PT & CT which shall include ratio test and healthiness of the HT and LT fuses and associate circuiting. (v) Breaker testing which includes (a)Insulation resistance, (b)Pick up and drop of operating coils, (c) To check IR Values(CT) (d) To carryout polarity test(CT), (e) to check Knee point voltage/ measurement in case of class PS CT (vi) Servicing of HT, 11 KV, VCB, 400 Amps capacity, 50 Hz, breaking capacity 50 KA by drawing out from moving contacts for smooth functioning including replacement of tripping and closing coils, 30 volts, DC and servicing of solenoid switch, all as directed, (vii)Dismantling of unserviceable bus bar bushing from existing 11 KV bus bar chamber and supply and fix bushing suitable to match existing bushing complete, (viii) Removing the burnt out fixed contact assembly from the HT, VCB, 11 KV, 400 Amps of Areva Make supply and fix contact assembly of copper strip all as specified and directed, (ix) To carryout HV (AC ) Test in open & close condition with suitable HV Kit for both 11 KV VCBs. (x) To check contact resistance (by millivolt drop test or with micro Ohm meter). (Note: Servicing of VCB to be done only by authorised dealer/ servicing partner of Schneider/ Areva/ Alstom and CG ( as approved by GE) and proper voucher to be submitted which will be responsibility of the contractor. Strictly No any other unauthorised servicing team/people will be allowed to carry out servicing).
S&F Spare parts of 11 KV VCB,400 Amps capacity as in repairs of Make: Crompton Greaves, conforming to the respective cat part given as under :-(Note :(i) Fixing & testing element of following item is deemed to be included under Sch `A’ item No 33 above. (ii) Quantity of under mentioned items is tentative and contractor shall have no claim on account of variation of quantity or non execution of any of the item.
(a) Vacuum interrupter suitable for 11 KV VCB Make CG
(b) Fixed contact block 400 amps.
(c) Auxiliary switch (6 NO + 6 NC ).
(d) Closing coil 30 V DC
(e) Tripping coil 30 V dc
(f) Heating element with thermo stat switch
(g) Buffer closing Spring
(h) Buffer opening Spring
(j) Support Insulator 11 Kv
Relay Digital type CGI 14N over current relay for VCB including testing complete all as specified and directed by engineer in Charge
Relay Digital type IRI-PRO-V2-31-EI-5-5with in 5A and frequency 50 Hz ,uv 24-270 V AC- 360 VDC and lw-6W all as specified and directed by engineer in Charge
M&L Calibration of IDMTL relays through primary and secondary injection method and testing complete, re-setting where required and ensuring proper functioning of earth fault and over current relays all as directed. (Spares required to be replaced shall be measured and paid for separately under relevant items here in after).Main incoming MRS, Main incoming Malar Camp.
S&F Tripping and closing coil shaft with springs & Trip strips of standard manufacturers suitable for existing relay, fixed as in repairs ( of make used by original manufacturer of VCB).
S&F Rack in rack out gear assembly of standard manufacturers suitable for existing VCB , fixed as in repairs ( of make used by original manufacturer of VCB).
S&F VCB spout of standard manufacturers suitable for existing VCB , fixed as in repairs ( of make used by original manufacturer of VCB).
S&F Vacuum Circuit breaker Mechanism for 11 kv VCB of standard manufacturers suitable for existing VCB , fixed as in repairs ( of make used by original manufacturer of VCB).
S&F Power Pack 110 V AC three phase and out put 30 volt DC as per sample, of standard manufacturers suitable for existing relay, and as per sample kept in the office of GE, fixed as in repairs.
S&F Potential trasformer voltage rating 110000/110 epoxy type fixing and testing complete as in repairs all as specified.
S&F Insulating mat 20 mm thick size of size 3’x6’ complete as in repairs all as specified and directed by engineer in charge .
S&F Electric insulating mat nominal 3 mm thick electric insulated P.V.C. synthetic sheet viz conforming to IS-15562 of 2006 alongwith suitable adhesive/chemibound, having leakage current tested to meet requirement of IS-8437, IS-3043, break-down strength 40 KV having no adverse impact of mineral oil, high insulation resistance including material for water proofing of floor and sealing of all joints as required, suitable for floor covering around electrical apparatus for voltage not exceeding 3.3 KV (AC) to ground complete as in repairs all as specified and directed by the Engineer-in-Charge
M&L Filtration/dehydration of transformer oil through filtration plant to improve the dielectric strength/insulation value of the transformer oil upto 40 KV (RMS) at 4mm gap complete all as specified and directed for various capacity of transformers/OCB’s installed at various locations
Supply, and filling/ replacement/topping up of transformer insulating oil EHV grade having dielectric strength not less than 40 KV (R.M.S) at 4mm gap high viscosity in transformer confirming to IS – 335 of 1983 all as specified and directed for various capacity of transformers installed at various locations
Supply and filling silica gel in breathers of various capacities of transformers including taking out old unserviceable silica gel complete all as specified
S&F Breather assembly transparent body suitable for 11/0.433 KV transformers of capacity upto 100 KVA to 500 KVA complete as in repairs all as specified
S&F Temperature gauge of existing specification/Model for transformers of capacity upto 400 KVA complete as in repairs all as specified
S&F Externally operated tap changer switch “OFF LOAD TYPE” on HV winding to vary the LV Voltage up to + 7.5% variation limit in steps of 2.5% complete suitable for upto 500 KVA transformers including testing complete as in repairs all as specified
S&F Rubberized cork sheet gasket of 6 mm thickness cut to size/shape for top cover of transformer upto 400 KVA capacity complete as in repairs all as specified
S&F LT side porcelain bushing for 100 to 400 KVA capacity transformer complete as in repairs all as specified.
S&F HT (11KV) side porcelain bushing for 100 to 400 KVA capacity transformer complete as in repairs all as specified
S&F LT side copper set stem with nut bolts and washers complete for 100 to 400 KVA capacity transformer complete as in repairs all as specified
S&F HT side brass set stem with nut bolts and washers complete for 100 to 400 KVA capacity transformer complete as in repairs all as specified
M&L HV / LV copper Coil 100 to 160 and 250 to 315 KVA(per Phase) complete as in repairs all as specified
M & L Hiring of Fault Locator Machine Vehicle, complete, from the authorised supplier alongwith their dedicated specialised team; finding out the exact HT fault location from both end terminations of underground cable; submission of report of fault for verification and records of Engineer in Charge; including necessary excavation and earthwork, returning filling in, removal of surplus spoil, sand cushioning, cable covers complete all as directed.
Transportation of transformer carefully, any capacity(100 - 500 KVA), including lifting, loading and unloading, from site of work/ power house to workshop and back after completion of work in workshop, complete with all safety measures all as directed. Note:(i) The transportation shall be to any distance within municipality limits of Baroda. (ii) Rates of Hydra for lifting transformer at both the places(Site and workshop) both time pre and post repair is deemed to be included in quoted rates.
M & L Preparation of transformer surfaces of any description, and capacity 100 KVA to 400 KVA, in any position and painting of transformers out side with applying two coats of synthetic enamel grey paint after removing all dust/rust and paint must confirm to IS 2032 (latest) including writing the SM No/MES No on transformers with white paint in the existing style/pattern complete all as specified & directed by Engineer-in-Charge.
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . Any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
M&L Repair to old rusted/worn out wire fencing area of any type and description area not exceeding 50 sqm each including necessary welding ,clamping nut bolt etc complete all as specified and directed. Note : Required items for repair like barbed wire , MS flat , chain link fence nut bolt shall be provided by the contractor without any extra cost to deptt
M&L Taking out LT UG cable of size( 4x16sqmm to 3.5x300sqmm) 1100 volts from wall or trenches including bricks protection from the trenches etc complete all as specified and as per directed Engr-in-Charge.
Relaying of serviceable LT UG cable retrieved from taking down/ dismantling, after cutting into pieces serviceable portion complete all as specified and directed by Eng-In-Charge. Note:- Excavation, retuning filling removal , cable joints as applicable shall be measured & paid separately under relevant items in case making re route for relaying UG cable
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm 3.5 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size120 sq mm 3.5 core complete all as specified
Supply, laying and testing ,cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size185 sq mm 3.5 core complete all as specified
Re-laying only burnt bricks (old size) obtained from dismantling/ taking down of UG cables from trenches as cable protection complete.
Supply and lay GI tubing 100 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete as in repairs all as specified
Supply and lay GI tubing 80 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete as in repairs all as specified
Supply and lay GI tubing 50 mm dia, light grade for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete as in repairs all as specified
S&F Aluminium Lugs 185 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 120 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 95 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 70 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 50 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 35 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
S&F Aluminium Lugs 25 sqmm as per IS 8309 Tubular Lugs Aluminum tubular Terminal ends, for crimping to Aluminum Conductors made out of 99.5% pure aluminium complete all as specified
Supply , jointing and testing cable jointing kit for LT UG cable for straight through out door heat shrink type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured at cable of size 25 sqmm to 50sqmm as in repairs all as specified
Supply , jointing and testing cable jointing kit for LT UG cable for straight through out door heat shrink type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured at cable of size 70 sqmm to 95sqmm as in repairs all as specified
Supply , jointing and testing cable jointing kit for LT UG cable for straight through out door heat shrink type joint complete with jointing materials and accessories suitable for 3.5 core XLPE armoured at cable of size 120 sqmm to 185sqmm as in repairs all as specified
M&L Cleaning of grass and bushes around LT Panel area, complete including cutting unwanted ingress upto3mtrX3mtr area complete all as specified and directed by Engineer-In-Charge. Note: The contractor shall bring all the tools and man power for proper cleaning of the area shown by concerned AGE/JE(E/M).
S&F MCCB 4 Pole 63 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 10 KA complete as in repairs all as specified and directed.
S&F MCCB 4 Pole 100 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 25 KA complete as in repairs all as specified and directed.
S&F MCCB 4 Pole 160 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 25 KA complete as in repairs all as specified and directed.
S&F MCCB 4 Pole 200 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 25 KA complete as in repairs all as specified and directed.
S&F MCCB 4 Pole 250 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 25 KA complete as in repairs all as specified and directed.
S&F MCCB 4 Pole 400 Amps conform to IS/IEC 60947-2,IEC 60947-2 & EN 60947-2,Ics=100% of Icu,common SS enclosure with thermal magnetic Release, 415 volts, 50 KA complete as in repairs all as specified and directed.
Dighard Electricals
BHARAT NIRMAN INFRASTRUCTURE COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .