Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹86.7 LAccepted-AOC 27 19 F F D BLOCK CHATTARPUR EXTN SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹93.9 L+₹7.2 L (8.32%)Rejected-Finance 18 MOTI BAGH BABYAL ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹94.2 L+₹7.5 L (8.68%)Rejected-Finance 179 THE MALL AMBALA CANTT 133001 HR | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹1.2 Cr+₹28.5 L (32.9%)Rejected-Finance 256 MODEL TOWN AMBALA CITY 134003 | AMBALA CITY | AMBALA | HARYANA | 134003 | L4 | Rejected-Finance Not Lowest | |
| 5 | Rejected-Technical 800 RAM NAGAR ROORKEE DISTT HARIDWAR UK PIN 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | - | Rejected-Technical Two Class below firm |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
12 Feb 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) AMBALA
HQ CWE (AF) Ambala Ambala cantt 133001
IMPROVEMENT OF MAP QTRS OF SEKHON ENCLAVE AT AFS AMBALA UNDER GE (AF) AMBALA
2023_MES_634770_1
CWE/AF AMB/AMB-42/2023-24
Open Tender
Civil Works
Item Rate
270 days
AMBALA CANTT
For MES enlisted contractor Class B Category a i and for un-enlisted contractor refer NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) AMBALA
₹2.2 L
Yes
10 Jun 2024
28 Dec 2023
14 Feb 2024
28 Dec 2023
12 Feb 2024
30 Jan 2024
28 Dec 2023 - 12 Jan 2024
Amount
Dismantling of floor hearth or wall tiling including cement mortar bedding but not backing and removing serviceable tiles to store yard and rubbish off the premises to a distance exceeding 500 mtr complete all as specified & directed.
M&L coloured non-skid, ceramic tiles, joint free, 1st quality, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including 15mm thick screed bed or bedding layers in cement mortar 1:6, complete all as specified & directed.
M&L coloured non-skid, ceramic tiles, joint free, 1st quality, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.18 Sqm but not exceeding 0.38 Sqm as in skirting/dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including 10mm thick rendering/ backing in cement mortar 1:4, complete all as specified & directed.
M&L coloured non-skid, ceramic tiles, joint free, 1st quality, 7 to 8 mm thick, square/ rectangular, area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including 15mm thick screed bed or bedding layers in cement mortar 1:6, complete all as specified & directed.
M&L coloured glazed ceramic tiles (1st quality), 300mm x 450mm, 7 to 8mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering / backing in cement mortar 1:4 complete all as specified & directed.
Dismantling of stone slabs and tiles of any description or thickness laid, bedded and pointed in any mortar in floors, aprons etc complete all as specified & directed.
M&L 18 to 20mm thick granite work (table rubbed and polished) in steps, jambs pillars, window-cills, cooking platforms, wash hand basin platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:4 including bull nosing of edges complete all as specified & directed. Note: The granite shall be laid as in single piece(or as directed) for entire area of platform and hole of required bore for gas pipe etc. shall be made without any extra cost.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame), area not exceeding 1.5 sqm each and removing from site, complete all as specified & directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame), area exceeding 1.5 sqm but not exceeding 4.00 sqm each and removing from site, complete all as specified & directed.
Taking down shutters of any description, area exceeding 1.0 sqm but not exceeding 2.0 sqm each complete all as specified & directed.
Taking down shutters of any description, area not exceeding 1.0 sqm each complete all as specified & directed.
Taking down boardings of any description and any size as in shelves complete all as specified & directed.
Taking down, easing, adjusting of shutters, any description, area exceeding 1.0 sqm but not exceeding 2.0 sqm each and refixing in same opening including refixing of builders hardware as required including hinges with necessary welding/fixing, renewal of unserviceable screws etc. complete all as specified & directed.
S&F 18/19mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to steel/timber frame work complete all as specified & directed.
S&F teak wood beading of size 20mm x 6mm on the exposed edges/surfaces of the particle board, plywood complete all as specified & directed.
S&F Plywood 19mm thick (05 No. ply), grade BWR, type BB, including cutting, jointing, fixing with screws timber frame as in cup board doors and shelves, complete all as specified & directed.
S&F Plywood 9mm thick (05 No. ply), grade BWR, type BB, including cutting, jointing, fixing with screws timber frame as in cup board doors and shelves, complete all as specified & directed.
S&F 0.90mm thick decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions, complete all as specified & directed.
S&F extruded aluminium alloy handles size 100mm, fabricated type, anodised complete all as specified & directed.
S&F 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified & directed.
S&F magnetic ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete all as specified & directed
S&F continuous (piano) hinges, mild steel, bright finish or electrogalvanised, width of flaps (when open) 40mm complete all as specified & directed
S&F 100 mm size hasp and staple, safety type, aluminium anodised, including bolt to hinge plate and fixed with screws, complete all as specified & directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube suppling & fixing in opening as per specification & drawing given in SSR Part–II complete all as specified & directed.
S&F factory made solid PVC moulded door Shutter with wood free EPS, 28mm to 30mm thick (stiles), with 2, 4 or 6 raised panel design with 2mm thick moulded prelaminated PVC sheet on the front face & 2mm prelaminated PVC Sheet on back face, supplying & fixing in frame at site as per specification & drawing given in SSR Part –II complete all as sepcified & directed.
S&F pressed steel frames of size 105mm x 60mm, 1.25mm thick for door with one or more rebates, including necessary fixing lugs, hinges lock strike plate etc. complete all as specified & directed.
S&F pressed steel frames of size 125mm x 60mm, 1.25mm thick for door with one or more rebates, including necessary fixing lugs, hinges lock strike plate, etc complete all as specified & directed. Notes for BOQ item No. 26.00 & 27.00: The rates include for one shop coat of priming. The sizes/dimensions and type (profile) of frames shall be as shown in IS code. Filling hollow of frame with plain cement concrete and/or with cement mortar shall be measured and paid separately.
M&L plain cement concrete(PCC) 1:3:6, type C-0, using 12.5mm graded mechanically crushed stone aggregate as in filling the chowkhat/frames complete all as specified & directed.
S&F 35mm thick flush shutter, solid core construction with block board core and ply wood face panels, commercial type on both side, complete all as specsified & directed. Note: The rates for flush shutters include for the provision of suitable blocks for taking mortice locks, latches, or other fittings.
M&L 2nd class hardwood glazed and skeleton shutters, 35mm thick, factory made, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, complete all as specified & directed. Note: Glass or wire cloth, etc. in panels or sash squares shall be measured & paid separately.
S&F aluminium anodised barrel tower bolts of extruded section, 150 mm long complete all as specified & directed.
S&F aluminium anodised cast type handles 150mm long complete all as specified & directed.
S&F aluminium alloy, anodised, 300mm long sliding door bolt with hasp, staple bolt type and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections complete all as specified & directed.
S&F 100mm size Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-11 fixed to chowkhat complete all as specified & directed.
S&F factory made Box type steel window, double shutter, glazed and wire gauzed with side hung shutters including box type hinges, steel handles fabricated type for each leaf duly welded, mild steel barrel tower bolts 150mm size (02 Nos for each leaf) duly welded, complete with glazing bars dovetailed or welded including MS fillets complete all as specified & directed. Notes: - (i) Windows shall be fabricated as per drawing No. TD-219 Sh 1/3 to 3/3 and these drgs may be referred from GE office or from the office of CWE (AF) Ambala. (ii) Glazing, Wire cloth & MS guard bars shall be measured and paid separately . (iii) Painting to window shall be measured and paid separately however one shop coat primer included in quoted rates. (iv) Double shutter meant for providing glazed shutter as well as wire gauged shutter on outside & inside of the frame respectively. Both the shutters shall be measured as one unit. (v)Steel window shall comply with IS 1038-1983 &. Rolled steel sections for fabrication shall conform to IS 7452-1990
S&F steel ventilator with top hung shutters, factory made comfirming to IS 1038-1983 & IS 7452 - 1990 including hinges, peg stays with glazing bars etc with & including one shop coat of red oxide primer complete all as specified & directed. Note: - Glazing , wire gauge shall be measured & paid separately.
S&F galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specifed & directed.
S&F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or galvanised wire staples complete all as specifed & directed.
Hacking out old broken glass (any thickness, size, quality, & description) from wooden/steel frames glazed with putty or fixed with beads etc. complete all as specified & directed.
S&F sheet glass 3.0mm thick, ordinary quality, glazing with oil putty in squares not exceeding 0.5 sqm in each pane fixed with oil putty or wooden beads including glazing pins/ spring clips wherever necessary etc. complete all as specified & directed.
S&F 3.0mm thick figured glass, pin head type, glazing with oil putty in squares not exceeding 0.50 sqm in each pane fixed with oil putty or wooden beads including glazing pins/ spring clips wherever necessary etc. complete all as specified & directed
S&F mild steel work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe-290 Gde-E-165 complete all as specified & directed
Cutting holes in brick walls, built in cement mortar, depth exceeding half brick thick wall but not exceeding one brick thick wall for inserting hold fasts etc. and making good the dismantled portion in plain cement concrete 1:2:4 type B-1 & finished to match as per the existing finish complete all as specified & directed Note:- Depth of embedded portion of holdfasts or lugs shall be measured from the face of the jamb into the wall.
S&F 300mm mild steel ordinary rat tail rod pattern spring including roller and roller plate complete all as specified & directed
Cutting chases, pinning in for brick walls, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring or similar works etc., and making good, cutting not exceeding 10cm girth complete all as specified & directed. Note: The girth of the chase shall be reckoned as that actually required for the work, that is, maximum height of the article or portion thereof inserted in the chase plus twice the depth of insertion.
Taking up or down steel water tubing and connections for refixing or removal from site,15mm bore pipe complete all as specified & directed.
Taking up or down steel water tubing and connections for refixing or removal from site, 20 mm bore pipe complete all as specified & directed. Notes for BOQ item No. 46.00 & 47.00 :(i) Taps, valves if any shall be removed before taking down pipe. Cutting chasing of wall etc. for concealed tubing wherever required shall deemed to be included in quoted rates.
S&F galvanised mild steel water tubes 15 mm bore, medium grade, with all fittings, fixed to wall and ceiling or laid in floor complete all as specified & directed.
S&F galvanised mild steel water tubes 20 mm bore, medium grade, with all fittings, fixed to wall and ceiling or laid in floor complete all as specified & directed.
Refixing 20mm bore water tubing (Old tube obtained from BOQ item No. 47.00 here-in-before shall be used) in same/new location after cleaning including cutting & threading pipe and including S&F of all fittings whereveer required complete all as specified & directed. Notes for BOQ item No. 48.00 to 50.00 : Concealed portion of tubes shall be painted with bituminous paint. The rates are deemed to be included for making good the disturbed surfaces of wall etc. The cutting chases for new location shall be measured & paid separately.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for complete all as specified & directed
S&F rolled mild steel framed work as in door of angle or other sections with gusset plates, rails, braces etc, using ornamental design as approved complete drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and purpose made hinges or steel hanging door fittings exclusive of steel sheeting or other covering, running rails and guides and hanging, fastening and fixing complete conforming to Fe 410W, Gde E-250 quality'A' complete all as specified & directed. Note :- Flat iron as in hold fasts shall be measured & paid separately.
S&F mild steel plain black sheet 1.25mm thick as in in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified & directed.
M&L mild steel works as in hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified & directed
Demolition of plain cement concrete (un-reinforced)/ PCC tile of any description and in any position not otherwise specifically provided for (as in sunken floors, coping, benching, padding, concrete tile on steps, etc.) and removing the debris outside the MD premises distance exceeding 1.50 Km but not exceeding 5 Km and depositing where directed, complete all as specified & directed.
Roughening surface of old concrete floor by picking sweeping clean and washing down with water to remove dust etc and brushing neat cement slurry @ 3.0 Kg/Sqm complete all as specified & directed.
M&L rendering / screed bed 10mm thick in cement mortar 1:3 on concrete surface or roof / wall mixed with water proofing compound as per manufacturer's instructions, finished when concrete is green complete all as specified & directed. Note:- Water proofing compound shall be measured & paid separately.
M&L water proofing treatment to roof slab complete all as specified here-in-below & as directed by Engineer-in-charge:- (i) Cleaning of dust, removal of all loose existing bituminious material manually and with heat torch gun to get smooth plain finished surface including removing of vegetation/plantation with no loose material on surface. Repairing all joints and cracks with Highly elastic Bituminous cold applied putty having penetration after setting upto 8mm. (ii) Levelling of surface to give proper slope will be done as per site requirements with Bituminous Mortar & Cold Emulsion cum waterproofing Liquid of water based bituminous emulsion. (iii) Creating SSD condition on surface with water. Prime the surface with acrylic modified bitumen with potable water in the ratio of 1:1 and apply @400gm per Sqm (As per Surface Conditions). (iv) Apply first coat of acrylic modified bitumen having elongation 200% conforming to ASTM-C-412 & having crack bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.50mm conforming to ASTM-C-412 with no diluation of water on primed surface while the surface is still tacky with consumption of 700gm per Sqm. (v) Laying Geotex of 45 GSM/ Fibre mesh simultaneously and paste it properly with overlap of 50mm. Allow the first coat to dry for 10 hrs to 12 hrs.
Item No. 58.00 continued...../- (vi) Apply second coat on cured first coat with consumption @ 700gm per Sqm in opposite direction of first coat by Brush or Roller. Allow it to dry for 10-12 hrs. (vii) Apply third coat with consumption @ 700gm per Sqm. Ensure final curing time of 36 hrs before allowing/ carrying out any further work. (viii) Conduct ponding test for minimum 7 day after applying two coats of single component , UV Resistant Elastomeric Exterior Acrylic Weather resistant water proof coating having elongation of 300% after curing of 14 days confirming to ASTM D- 6083-for UV Protection of Bituminous Elastomeric Acrylic Emulsified Liquid Membrane to give long life and prevent its deterioration from sunlight. Notes:- (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators only duly approved by GE in writing. (ii) For guarantee & security deposit refer Particular specifications.
M&L for carrying out water proofing treatment of sunken floor as specified here-in-below and as per direction of Engineer-in-charge:- (i) The concrete/ wall surface shall be cleaned throughly of all laitance , loose particles, dust , grease etc. any friable unsound area shall be chipped, cleaned and there after pre-weted to a saturated surface dried conditions. (ii) In case of potholes , superficial cracks found , the same shall be repaired with polymer modified mortar 1:3 ( 1 cement and 3 coarse sand )using Dr fixit pidicrete URP 301/Sika latex or equivalent in Asian paints/ Fosroc as admixture @ 10% of cement content and the same shall be applied on vertical area after removing of plaster upto 2 feet height (iii) On the prepared surface, apply a primer coat of Sika latex / Dr. fixit pidicrete URP 301 or equivalent in Asian paints/ Fosroc modified cement slurry 1:4:8 (1 admixture : 4 water : 8 cement), after prewetting the substrate @ 2 kg/sqm . (iv) The surface thus prepared shall dampen upto saturation and apply two coats of sika top seal 107 or equivalent in Dr fixit piddilite/Asian paints/Fosroc, acrylic modified water proofing coating on the entire area @1.5 kg/sqm (each coat) Second coat shall be applied after 6-8 hrs after the first coat and in the direction right angle to the previous coat . The water proofing should be taken to a vertical height of minimum 600 mm above.
Item No. 60.00 continued...../- (v) Apply open woven glass fiber mesh of sika Fab 1 or equivalent in Dr fixit piddilite/Asian paints/Fosroc, 150 mm wide strip over the PCC benching (Gola) whilst the first coat is wet and then apply scond coat . cure the hydrosent application ( Minimum 6-8 hrs drying) for a minimum 3 to 5 days. (vi) Apply a protection layer of 10 mm thick plaster made of 1:4 cement sand mortar admixed with integral water proofing compound Sika plastocrete plus/ Dr fixit piddilite LW plus or equivalent in Asian paints/ Fosroc @ 200 ml/bag of cement , applied over the water proofing coating . Notes: (i) The water proofing treatment shall be got carried out by the manufacturer or their authorised applicators only duly approved by GE in writing. (ii) For guarantee & security deposit refer Particular specifications. (iii) The rate include the cost of demolition of existing floor, sub base, PCC/ hardcore filled under floor, removal of debris, removal and replacement of damaged CI/PVC pipes, floor, Nahani traps etc.
M&L Plain Cement Concrete (1:5:10) type E-2, using 40 mm graded mechanically curshed stone aggregate as in sunken slab filling, mass concrete etc. complete all as specified & directed.
M&L machine cut kota stone slab flooring18mm - 20mm thick, using single piece kota stone slab as in flooring/ Treads, laid over & including screed bed 15mm thick in cement mortar 1:4, set and jointed with grey cement slurry or with adhesive as per manufacturer's instructions mixed with pigment to match the shade of the slab including rubbing and polishing achieve mirror finish, rounding off the edges and cutting two grooves (serration) complete all as specified & directed
M&L machine cut kota stone slab/tiles 18mm - 20mm thick, on vertical surface as in skirting/dado /step riser/pillars etc, laid over & including rendering 10 mm thick in cement mortar 1:4, set and jointed with grey cement slurry or with adhesive as per manufacturer's instructions mixed with pigment to match the shade of the slab including rubbing and polishing to achieve mirror finish complete all as specified & directed
Dismantling of brick work or stone/boulder masonary built in cement mortar including all quoins, pillars etc. but excluding ashlar facings, dressed stone work and precast articles complete all as specified & directed.
M&L Brick work with sub class B, burnt clay bricks of old size, designation 75, straight or curved on plan exceeding 6 mtr mean radius, built in cement mortar 1:6 complete all as specified & directed.
Description all as per BOQ item No 66.00 here-in-above but except bricks. Note: Old bricks retrieved from BOQ item 65.00 here-in-before shall be used after cleaning and washing.
M&L Brick work with sub class B, burnt clay bricks of old size, designation 75, straight or curved on plan to any radius in half brick thick wall, built in cement mortar 1:4 complete all as specified & directed.
Demolition of Plain cement concrete (un-reinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including removal of debris to a distance exceeding 5 Km complete all as specified & directed
M&L 25 mm thick plain cement concrete(PCC) 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates as in sub base of floor complete all as specified & directed.
M&L 20 mm thick plain cement concrete(PCC) 1:2:4 type B-0 using 12.5 mm graded mechanically crushed stone aggregates as in sub base of floor complete all as specified & directed.
M&L 100mm thick plain cement concrete(PCC) 1:4:8, type D-2 using 40mm graded mechanically crushed stone aggregates, as in sub base of floors/paving/plinth/ hardstanding complete all as specified & directed.
M&L chequered cement concrete commercial tiles 30cm x 30cm, 20-22mm thick as in floor, with grey cement and pigment, set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over & including 15mm thick screed bed or bedding layers in cement mortar 1:4 complete all as specified & directed.
M&L 75mm thick PCC 1:3:6, type C-1, using 20mm graded mechanically crushed stone aggregate as in plinth protection finished even and smooth without using extra cement with & including 10mm wide, 30mm deep joints at the rate of 3.00 mtr centre to centre and at every turning & filling the joints with bitumen & sand mixture complete all as specified & directed. Notes :- The unit rate quoted shall be deemed to include for providing the concrete in alternate bays not exceeding 3 Mtrs length. 30 mm deep joints between the bays shall be provided which shall be filled with mastic filling with hot bitumen 85/25 grade and 1:2 mix volume.
M&L for cutting/chipping the spalling concrete surfaces of chajjas/roof protection etc. and trimming & cleaning the surface to recieve dubbing and dubbing out with average 20mm thick in PCC 1:2:4 type B-0 and finishing the concrete surface with 5mm thick plastering in cement mortar 1:3 even & smooth with using extra cement complete all as specified and dirceted Notes: Necessary formwork required for the work shall deemed to be included in quoted rates. Necessary scaffolding as required at site shall be provided by contrator without any extra cost and shall remove the same on completion of the work.
M&L use & waste formwork to chajjas, kitchen slab, fins, fascia, louvers, parapet, railing and similar items, rough finished flat surfaces of concrete complete all as specified & directed
Demolition of Reinforced cement concrete(RCC) of any description and in any position not otherwise specifically provided including cutting the reinforcement as required to facilitate demolition and removal of debris to a distance exceeding 5 Km complete all as specified & directed. Note: Steel obtained from demolition shall be credited to contractor.
M&L reinforced cement concrete (RCC), type B-1, 1:2:4, nominal mix, using 20mm graded mechanically crushed stone aggregate as in chajjas and the like complete all as specified & directed.
M&L reinforced cement concrete (RCC), type B-1, 1:2:4, nominal mix, using 20mm graded mechanically crushed stone aggregate as in shelves, kitchen slab etc. complete all as specified & directed.
M&L reinforced cement concrete (RCC), type B-1, 1:2:4, nominal mix, using 20mm graded mechanically crushed stone aggregate as in fins, fascia, louvers, parapet, railing and the like complete all as specified & directed.
M&L precast reinforced cement concrete 1:2:4, type B-1 (using 20mm graded mechanically crushed stone aggregate) as in landings, cover slabs (for man holes/drain etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified & directed. Note: Reinforcement shall be measured & paid seperately.
M&L mild steel TMT bars 10mm dia and over, Fe500/Fe500D grade confirming to IS-1786, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
S&F tubular curtain rail, stainless steel anodized 20mm dia including taking down old unserviceable rod/rail complete all as specified & directed.
S&F stainless steel type brackets suitable to hold the curtain rod with sofio phenol (Lotto) and wooden round blocks suitable to curtain rod of 20mm dia, decorative type fixed with suitable steel screws and PVC cleats, including taking down old unservicable brackets complete all as specified & directed.
S&F in repair vitreous water closet china squatting pan, Orissa pattern, 580mm x 440mm, white, with and including PVC ‘P’ or ‘S’ trap front or back inlet with integral foot rests excluding flushing cistern and flush pipe including providing lime concrete bedding and making good to floor etc. complete all as specified & directed.
S&F in replacement PVC low level flushing cistern, white, valveless syphonic action type 10 litre capacity with inlet, ball valve, float and handle including PVC flush pipe 32 mm dia with bend and a pair of mild steel angle iron brackets of suitable size including making necessary connections to water supply pipe line and WC, complete all as specified & directed.
S&F in replacement sink with drainage board over all size 915mm x 460mm & bowl size 405mm x 355mm x 178mm, made of stainless steel (grade 304) 1.00 mm thick steel sheet, kitchen or laboratory with plug & chain, waste coupling, washers and 32 mm bore PVC waste pipe including bedding in cement mortar to dwarf wall or including fixing cantiliver MS brackets and connecting union to pipe complete all as specified & directed.
S&F in replacement stainless steel(grade 304) plate rack of size approx 750mm x 600mm x 250mm made out of 1.0 mm thick steel sheet complete all as specified & directed
Disconnecting existing PVC water tank of capacity exceeding 250 litres but not exceeding 500 litres (fixed on roof), setting aside (or lowering if required), cleaning, removing all scales, dirt from tanks, from mouths of circulating pipes, etc., and hoisting / re-fixing / re-connecting in same / new position, writing date of cleaning with white paint, (height / size of letters / figures not less than 10cm in height), refixing serviceable ball valve, complete all as specified & directed
S&F in repair Ball valves high pressure PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of dia 20 mm bore (Minimum weight 210 gram) complete all as specified & directed.
Dismantling old unserviceable RCC/PVC water tank of capacity exceeding 250 ltr but not exceeding 500 ltr cpacity including S&F 500 ltr capacity rotational moulded polyethylene(PVC) water storage tank, HDPE, double layered, cylinderical type fixed and hoisted in position on roof, at any height, making connections with 20 mm GI pipe inlets & outlets complete including locking arrangements and 20 mm bore ball brass valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gram) complete all as specified & directed. Notes: The water tank shall be placed nearest to the location / junction of roof beam / wall and shall not be placed at the middle of slab.
S&F in repair vitreous china wash hand basin, oval type, white, size 630mm x 450mm including 32mm bore PVC waste pipe of suitable length, CP waste fitting & one pair of mild steel angle iron brackets of suitable size fixed as in counter slab complete all as specified & directed.
S&F in repair 15 mm bore pillar tap, fancy type, brass chromium plated with capstan head chromium plated screwed down high pressure with or without lettered “hot' or 'cold” with long screwed shank and flynut screwed complete all as specified & directed.
S&F in repair 15mm bore fancy type stop valve/angle valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes complete all as specified & directed.
S&F in repair 15mm dia stop valves cast copper alloy chromium plated (Concealed type) fancy type, long shank and cup with capstan head and cup screwed both ends for iron pipe or for union complete all as specified & directed
S&F in replacement 20mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified & directed.
S&F in repair bib tap 15 mm bore, brass, chromium plated, fancy type, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified & directed.
S&F in repair brass chromium plated shower rose, fancy type, suitable for 15 mm bore pipe with or without swivel joints any size including fixed to steel pipe or union complete all as specified & directed
S&F in repair brass chromium plated tubular towel rail 20mm dia , fancy type, 60cm long, superior quality , between flanges fixed to wall with brass CP screws complete all as specified & directed.
S&F in repairs soap dish, brass, chromium plated, size 160mm x 160mm x 90mm fixed with and including plugs with brass CP screws complete all as specified & directed.
S&F in repair sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified & directed
S&F in repairs PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified & directed
S&F PVC (SWR) bends any radius, 75mm bore with / without access door, complete all as specified & directed.
S&F PVC (SWR) junction single 'T' equal or unequal 75mm bore with access door complete all as specified & directed.
S&F PVC (SWR) bends any radius, 110mm bore with / without access door, complete all as specified & directed.
S&F PVC (SWR) junction single 'T' equal or unequal 110mm bore with access door complete all as specified & directed.
S&F PVC (SWR) multi-floor trap/multi-nahani trap, plain/single hole with chromium plated grating including jointing with solvent cement, 75mm dia, including dismantling the damaged trap, complete all as specified & directed.
S&F in repair 75mm dia outlet PVC Floor Trap/Nahani trap with including, plain / single hole chromium plated grating, type-B pipes including jointing to waste pipe with solvent cement complete all as specified & directed
S&F in repairs PVC connection 600mm long with 2 nos PTMT check nuts, suitable for 15mm bore complete all as specified & directed
S&F PVC (SWR) gully trap 125mm x 110mm, made of type-B pipes, setting and jointing with solvent cement complete all as specified & directed
Cutting holes into or through brick walls built in cement mortar, superficial area not exceeding 150sqcm, and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required, complete all as specified & directed. Note: The quantity shall be measured & paid as " per centimetre of depth of cutting"
Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or any pattern(PVC/AC), including all fittings, heads, shoes, bends, swan-necks, etc., and S&F of PVC (SWR) pipes 110mm dia, single socketed in any length with solvent cement joints laid under floor or fixed on walls as soil / waste / vent pipes with Stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified & directed
Taking down eaves gutters, soil / waste / vent pipes / rain water pipes (any size or any pattern(PVC/AC), including all fittings, heads, shoes, bends, swan-necks, etc., and S&F of PVC (SWR) pipes 75mm dia, single socketed in any length with solvent cement joints laid under floor or fixed on walls as soil / waste / vent pipes with Stack clamps made out of 50mm x 5mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall complete all as specified & directed
S&F UPVC (SWR) pipe, 40mm dia including necessary connectors, bends, Tee etc. conforming to IS:4985-2000 fixed with solvent cement joints, laid on floor or fixed on walls as drain pipe in wash hand basin, spout pipes in balconies etc. complete all as specified & directed
S&F GI pipe spout 40 mm dia medium grade to be embeded in sunken floor and necessary connectors, bends, tee, elbow etc. complete all as specified & directed.
Taking down cement plaster on brick or stone walls or ceiling/soffit surfaces etc. including racking out joints, hacking for key, scrubbing down with water including removal of debries to distance exceeding 1.50 Km but not exceeding 5.0 Km complete all as specified & directed.
M&L rendering 10mm thick in cement mortar 1:6 on fair faces brick or concrete surfaces, finished even and smooth without using extra cement complete all as specified & directed.
M&L rendering 15 mm thick in cement mortar 1:4 on other than fair faces brick or concrete surfaces mixed with WPC @ 2 % by weight of cement content, finished even and smooth without using extra cement complete all as specified & directed. Notes : (i) WPC shall be measured and paid separately. (ii) Area to be plastered may require to be carried out up to height of 15 mtr, necessary scaffolding required shall deemed to be included in quoted rates.
M&L rough cast plaster including 15 mm thick rendering in cement mortar 1:3 on brick work or concrete surface all as specified in SSR Part -1 clause 14.22 complete all as specified & directed. Notes : (i) Rough cast plaster finish shall be as follow :- After applying the under coat in cement mortar 1:3 and while it is still in plastic state the rough cast mixture consisting of crushed stone or fine gravel aggreagte (Which is generally of size between 6mm to 12mm depanding on the texture required mixed with coarse sand and cement in the ratio of 1:1:1 shall be applied and finished even. The mix of cement and sand shall be made slightly wetter than normal for rendering to ensure the larger aggregate are throughly covered. (ii) Area to be plastered may require to be carried out up to height of 15 mtr, necessary scaffolding required shall deemed to be included in quoted rates.
M&L rendering 5 mm thick in cement mortar 1:3 on the soffit of slab/chajjas/ sunshade etc finished even and smooth without using extra cement complete all as specified & directed.
Supply only integral water proofing compound ISI marked complete all as specified & directed
M&L preperation of newly plastered surface of ceiling/soffit etc. by vacuum based sanding machine and applying three coats of white lime wash by auto roller over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish complete all as specified & directed. Note: Multipurpose mixer shall be used for uniform and proper mixing of wall care putty.
M&L complete removal of existing treatment from old decorated plastered surface of ceilings/soffits etc. by vacuum based sanding machine, removal of nails etc & filling cracks / holes with putty and applying three coats of white lime wash by auto roller over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish complete all as specified & directed. Notes: (i) The height of the bldgs are approx. 12 mtr. (ii) First the complete removal of existing treatment shall got approved by GE & Engineer-in-charge before applying wall care putty. (iii) Final coat of white wash shall be done after getting approval of completion of priming coat from GE and Engineer-in-charge. (iv) Multipurpose mixer shall be used for uniform and proper mixing of wall care putty.
M&L applying two coats of 100% premium emulsion acrylic paint having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance , dirt resisitance exterior paint of approved shade/tint(Company depot tinted), with silicon additives @1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm on newly plastered surfaces of walls including preparation of surfaces complete all as specified & directed. Note: For guarantee & security deposit refer Particular specifications.
M&L applying two coats of 100% premium emulsion acrylic paint (by auto roller) having VOC less than 50gm/litre and UV resistance as per IS 15489:2004, alkali and fungal resistance , dirt resisitance exterior paint of approved shade/tint(Company depot tinted), with silicon additives @1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish on newly plastered surfaces of walls including preparation of surfaces by vacuum based sanding machine complete all as specified & directed. Notes: (i) Multipurpose mixer shall be used for uniform and proper mixing of wall care putty. (ii) For guarantee & security deposit refer Particular specifications.
M&L applying two coats of 100% premium emulsion acrylic paint (by auto roller) having VOC less than 50gm/litre and UV resistance as per IS 15489:2004 , alkali and fungal resistance , dirt resisitance exterior paint of approved shade/tint(Company depot tinted), with silicon additives @1.43 Litre/10 Sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 Sqm over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish inlcuding complete removal of existing treatment from old decorated plastered walls, removal of nails etc., filling cracks/holes with putty including preparation of surfaces by vacuum based sanding machine complete all as specified & directed. Notes: (i) The height of the bldgs are approx. 12 mtr. (ii) First the complete removal of existing treatment shall got approved by GE & Engineer-in-charge before applying wall care putty. (iii) Final coat shall be done after getting approval of completion of priming coat from GE and Engineer-in-charge. (iv) Multipurpose mixer shall be used for uniform and proper mixing of wall care putty. (v) For guarantee & security deposit refer Particular specifications.
M&L two coats of oil bound distemper of approved shade/tint by auto roller over & including one coat of alkali resistant primer over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish on newly plastered surfaces of walls including preparation of surfaces by vacuum based sanding machine complete all as specified & directed. Note: Multipurpose mixer shall be used for uniform and proper mixing of wall care putty.
M&L two coats of oil bound distemper of approved shade/tint by auto roller over & including one coat of alkali resistant primer over & including one coat of minimum 1mm thick wall care putty to achieve smooth surface finish on old treated wall inlcuding complete removal of existing treatment from old decorated plastered wall surfaces, removal of nails etc., filling cracks/holes with putty including preparation of surfaces by vacuum based sanding machine complete all as specified & directed. Notes: (i) The height of the bldgs are approx. 12 mtr. (ii) First the complete removal of existing treatment shall got approved by GE & Engineer-in-charge before applying wall care putty. (iii) Final coat shall be done after getting approval of completion of priming coat from GE and Engineer-in-charge. (iv) Multipurpose mixer shall be used for uniform and proper mixing of wall care putty.
M&L preparation of new steel and iron based surface of any description over 10cm width or girth and applying two coats of synthetic enamel paint over & including one coat of red oxide primer complete all as specified & directed.
M&L preparation of new wood and wood based surface of any description over 10cm width or girth and applying two coat of synthetic enamel paint over & including one coat of pink primer complete all as specified & directed.
S&F Stainless steel chromium plated peg set having 6 pegs for hanging of clothes of approved pattern, shape and size complete all as specified & directed.
M&L preparation of old or previously treated steel and iron based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
M&L preparation of old painted or previously untreated wood and wood based surface of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified & directed.
Excavation in trenches, not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth; for foundation, laying/taking out pipes/cables etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10sqm on plan & not exceeding 1.5mtr in depth and getting out, in soft/loose type of soil complete all as specified & directed.
Cleaning of sewage line any bore/dia/depth by mechanical means from gully traps, grease traps etc. by removing all filtn/silt, foreign materials and other deposits whatsoever completely and making the line free from all obstacles and finally cleaning the sewage line by roding or flushing with water, testing the flow of sewer line evenly, smoothly by filling water. Removing the silt/suldge & other deposits outside of MD land in covered van/trolly etc. complete all as specified & directed.
M&L cleaning of manholes manually or mechanically, depth upto 1.5 mtr by removing all silt, sludge any other materials, making clean and flushing with water complete including removal of spoils out side MD land and taking out cover slab and reset in the same position after cleaning and testing complete all as specified & directed. Note for BOQ item No. 135.00 & 136.00 :- The work lies under foul condition and quoted rate are deemed to be included for said condition.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete), internal dia 150mm set in cement mortar including demolition of concrete bed and removal of debries to distance exceeding 1.50 Km complete all as specified & directed. Note: Necessary excavation and earthwork will be measured & paid separately.
M&L plain cement concrete(PCC) bed 1:4:8, type D-2 using 40mm graded mechanically crushed stone aggregates to drain pipes of 150mm bore including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified & directed. Note: The rates include for any necessary shuttering and supports to concrete and for laying beds to falls.
M&L 150mm bore reinforced concrete pipes, class NP3 laid and jointed as in trenches complete with collars complete all as specified & directed.
M&L plain cement concrete(PCC) 1:3:6 type C-2 using 40mm graded mechanically crushed stone aggregate as in foundation, filling and mass concrete complete all as specified & directed.
M&L plain cement concrete(PCC) 1:2:4 type B-2 (using 40mm graded mechanically crushed stone aggregate) in surface channels and drains including necessary formwork complete all as specified & directed.
M&L plain cement concrete(PCC) 1:2:4, type B-0, using 12.5 mm graded mechanically crushed stone aggregates as in lintels upto 1.5mtr clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork to complete all as specified & directed.
Uprooting scrubs / plant / flora / fauna on walls, girth not exceeding 100mm, cutting holes in walls, digging out roots and applying sulphuric acid / phenolic acid as per manufacturers instructions to burn out deep grown roots and making goood the surface using cement mortar 1:3 mixed with & including water proofing compound complete all as specified & directed Note : The height of walls is upto 15 mtr, necessary cost of scaffolding shall deemed to be included in quoted
Taking down copper/aluminium point wiring (light, fan, bell, socket or power) complete, including taking out/down of unserviceable fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, call bell, light fitting etc., taking credit and making good disturbed surfaces of walls/floors/ceilings complete all as specified & directed .
Taking down carefully unserviceable distrubution boards including MCCB/MCBs of any size, type/rating etc. and making good disturbed surfaces of walls/floors/ceilings complete all as specified & directed .
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated sheathed cable 1.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 20mm bore medium grade, with fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc as in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, sheathed, multistranded copper earth conductor 1.5 sqmm connected to common earth and earth dolly for one light / fan / bell point controlled by one way switch 5/6 Amp complete all as specified & directed.
Description all as per BOQ item No. 146.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the independent board.
Description all as per BOQ item No. 146.00 here-in-above but for one socket outlet point 5/6 amp controlled by one way switch on the same board.
Description all as per BOQ item No. 146.00 here-in-above but for one light point controlled by two way switch 5/6 Amp complete all as specified & directed.
M&L concealed point wiring with Flame retardant low smoke(FRLS), PVC insulated sheathed cable 2.5 sqmm with multistranded copper conductor, 1100 volt, drawn through in and including non metallic rigid PVC conduit not less than 25mm bore medium grade, with fittings including all tees, bell mouth tube ends and fixing accessories such as couplers, saddles, pipe hooks etc as in wall/ceiling/roof etc with provision of new sunken type pressed steel/welded MS terminal boxes of not less than 1.6mm wall thickness(duly painted with two coat of anticorrosive paint outside & aluminium paint inside) with decorative laminated sheet top cover 3mm thick including Flame retardant low smoke(FRLS), PVC insulated, sheathed, multistranded copper earth conductor 2.5 sqmm connected to common earth and earth dolly for one socket outlet point 15/16 amp controlled by one way switch on the independent board complete all as specified & directed.
S&F switch piano, flush type single pole, one way 6/5 Amp complete all as specified & directed
S&F switch piano, flush type single pole, two way 6/5 Amp complete all as specified & directed
S&F switch piano, flush type, 15 amp, single pole, one way complete all as specified & directed.
S&F socket outlet 2 in 1, 3 pin, 5 amp flush type complete all as specified & directed
S&F socket outlet 2 in 1, 3 pin 5 & 15 amp flush type complete all as specified & directed
S&F bell push button 5 amp flush type complete all as specified & directed
S&F call bell ding dong type 230 volt, single pole complete all as specified & directed
S&F ceiling rose 65mm x 50mm three terminals 230 volts complete all as specified & directed
S&F lamp holder PVC/polycarbonate type and back plate suitable for batten fitting etc complete all as specified & directed.
S&F LED bulb 7 watt B22 type complete all as specified & directed.
S&F 1x18 watt wall mounted, new generation LED T-8 Retro fit for multipuspose application with LED Rod, made from exturded aluminium housing, polycarbonate diffuser including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified & directed.
S&F 1x10 watt wall mounted, new generation two feet LED Batten fitting for multipuspose application with exturded aluminium housing with decorative end caps including all fixing accessories & connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as sspecified & directed.
S&F new generation energy saving 9/10 watt LED bulk head (porch light fitting) made of plastic housing with opal diffuser complete all as specified & directed.
S&F LED street light fitting, 45 watt, input voltage 110 volt to 240 volt AC, 50Hz with ingress protection IP 65, the luminries must have secondary optics with perfectly matched lenses for better light control, comfirming to IEC60598/ISI10322, with provn auto shut down on high voltage, minium 25000 burning hours (life), operating temperature 1 to 50 degree centigrade, rectangular shape with pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system waltage of 45watt=10%watt, rated lumens of minimum 4500 lumens with 120 degree view angle, constant current type driver having THD<10% and power factor > 0.95 with short/open/reverse circuit protection, high voltage protection, protection against 10KV high surges including all fixing arrangement like clamps, nuts, bolts, washers, all accessories, pre-wired and connecting with twin core twisted flexible copper conductor cable with all necessary staging etc. for fixing including S&F bracket for light fitting made up of 1.2 mtrs long GI pipe 25mm bore medium grade including necessary fitting such as two Nos. 90 degrees bends MS clamp, nut, bolt, washer etc duly painted complete all as specified & directed.
S&F heavy duty, exhaust fan, single phase, 230/240 volt, 300mm sweep, steel body, 1400 RPM, totally enclosed heavy duty motor with copper winding including mounting brackets fixing on frame including S&F MS sheet 1.00mm thick as louver shutter for exhaust fan with all accessories fixed on wall and making connetions with twisted copper flexible wire 23/0.0076mm complete all as specified & directed. Note: Widening of hole in circular shape for fixing of 300 mm sweep exhaust fan deemed to be included in quoted rates.
Disconnecting electric connection and taking down carefully walls fan/exhaust fan/Air ciculator fan any sweep and removing fan and fan blades to AGE E/M storeyard complete all as specified & directed.
Taking down old unserviceable ceiling fans and depositing to the MES store complete all as specified & directed.
S&F ceiling fans complete with blades, down rods, fan regulator socket type and accessories, 230 volt, 1200mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, 5 star rated without remote with brushless direct current motor (BLDC) hanging, connecting with existing point complete all as specified & directed. Note: Cost of writing MES No./SM No. on fan is included in quoted rates.
M&L making Hole for 200mm sweep plasitc fan in suitable square/rectagle/circular shape in wall and making good the damaged surface complete all as specified & directed.
Fixing of exfaust fan of any size to same site after repair/servicing including flexible cable from celing rose to fan complete all as specified & diirected
S&F exhaust fans AC single phase 230/240 volt of size 200mm sweep made of sturdy engineering plastic with louver, shutter complete including all fixing accessories complete all as specified & diirected
S&F single pole & neutral, sheet metal enclosure with socket plug top with a two pin and earth plug and socket concealed in wall complete including one single pole MCB 20 Amp, 240 volts complete all as specified & directed.
Taking down carefully copper/aluminium submain wiring and removing materials from site and making good disturbed surface complete all as specified & directed. Note: The cost of cutting of chases wherever required shall deemed to included in quoted rates.
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable, 1100 volts grade, 4 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 4 sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified & directed.
M&L concealed sub main wiring with two single core FRLS, PVC insulated, unsheathed cable, 1100 volts grade, 6 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS, PVC insulated, unsheathed 6 sqmm stranded copper conductor as earth continuity cable drawn through in & including non metallic rigid PVC conduit medium grade not less than 25mm bore including accessories concealed in wall/floors/roof etc including cutting chases in wall/ceiling and making good the disturbed surfaces to match with existing surface complete all as specified & directed. Note for BOQ Item No. 174.00 & 175.00 :- Three runs copper cable alongwith conduit shall be measured as one unit. The cost of cutting of chases for new location (if any) shall be measured and paid separately.
S&F sheet metal enclosure distribution board, double door type for incoming MCCB, IP 43 degree of portection, TPN 4 way vertical type, powder coated with shrouded neutral bar & Pan assembley with connecting link, flushing in wall including connecting up all incoming and outgoing cables/circuit wiring complete all as specified & directed. Note: MCCB shall be measured and paid separately.
S&F sheet metal enclosure distribution board, 230 volt, single pole and neutral, IP 43 protection, with 200 Amps rated copper busbar and neutral link, 8 way, double door type flushed inside the wall including making good the disturbed surfaces complete all as specified & directed.
S&F MCCB 100 Amp, 415 volt, 4 pole 16KA with fixed thermal release fixed magnetic proteciton complete all as specified & directed.
S&F MCB 40 Amp, SPN, C curve 240 volts, 10 kA finger proof terminal, bi-connect terminatin, label holder, 35 mm' terminal capacity, insulated sliding shutter , large two position dolly ISI marked to be fixed on DB complete all as specified & directed.
S&F MCB 5 to 32 Amp, SP, C curve 240 volts, 10 kA finger proof terminal, bi-connect terminatin, label holder, 35 mm' terminal capacity, insulated sliding shutter , large two position dolly ISI marked to be fixed on DB etc complete all as specified & directed.
Taking down old unserviceable earthing any type complete all as specified & directed.
M&L earthing complete with galvanized steel earth plate electrode 600mm X 600mm, 6mm thick buried vertically in ground to depth not less than 2.25 mtr below ground level, with top edge of earth plate not less than 1.5 mtr below ground level surrounded from all sides by 15cm thick packed layer of charcoal dust & common salt filled in alternate layers and electrode connected to GI earth lead wire 4.0mm dia upto 7.5mtr long by means of bolts, nuts, check nuts and washers of galvanized iron and connection to earthing test point & earth dolly & watering pipe 1.5 mtr long medium grade GI 20mm bore including protection pipe upto 7.5 mtr long GI light grade 15mm bore, including wire mesh, funnel, lugs, salt, charcoal dust, excavation in soft/losse soil, returning filling & removal of surplus soil upto 50mtr, pit chamber shall be of PCC 1:2:4 type B1 using 20 mm graded mechnically crushed stone aggregates and pit cover slab 80mm thick Precast RCC 1:2:4 type B-1 using 20 mm graded mechnically crushed stone aggregates reinforced with XPM weighing not less than 4Kg/sqm including necessary form work complete all as shown in electrical plate No 3 of SSR part-I, including testing on completion at site complete all as specified & directed. Notes :- On testing if the earth resistance is not obtained, earthing will be generated at no extra cost , till the desired earth resistance is obtained. The chamber shall be constructed atleast 1.5 mtr away from the earth electrode.
Disconnecting electric and water connection and taking down carefully Geyser and deposited to AGE E/M storeyard through proper documentation and refixing the geyser at same location as and when required complete all as specified & directed
Taking down carefully electric meter from the exising place, kept in safe custody and refixing the same after completion the work with suitable size of copper wire for necessary action from meter to DB and meter mounted on suitable size of steel box complete all as specified & directed Notes:- The Reading of Meter will be taken in presence of BSO rep and all reading of meter shall be kept on record
For Credit Schedule refer tender documents. The amount of credit schedule shall be deducted from total quoted amount of BOQ to arrive contract sum.
Gupta Enterprises
M/s B.S.Jain
M/S SHANTI CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .