Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.1 CrAccepted-AOC | ₹4.1 Cr Quoted ₹4.3 Cr | L1 | Accepted-AOC Work Order Issued |
| 2 | L2₹4.5 Cr+₹20.3 L (4.76%)Rejected-AOC H NO 3 TIRANGA PATH P O HENGRABARI KALI MANDIR P S DISPUR GHY KAMRUP M PIN 781036 | KAMRUP METRO | ASSAM | 781036 | ₹4.5 Cr+₹20.3 L (4.76%) | L2 | Rejected-AOC L2 |
| 3 | Rejected-Technical 136 MANIRAM DEWAN ROAD CHANDMARI GUWAHATI ASSAM PIN NO 781003 | KAMRUP METRO | ASSAM | 781003 | - | - | Rejected-Technical Technically Non Responsive |
| 4 | Rejected-Technical | - | - | Rejected-Technical Technically Non Responsive |
| 5 | Rejected-Technical DAKHINGAON KAHILIPARA P O P S DISPUR ASSAM | - | - | Rejected-Technical Technically Non Responsive |
Tender Value
₹4.1 Cr
EMD Value
₹8.1 L
Closing Date
1 Mar 2023, 2:00 pmClosed
CE, PWD (Bldg), Assam, Chandmari, Ghy-3
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
Construction of Proposed Inspection Bunglow at Tangla
2023_PWBNH_29205_1
CE/TB-VII/3/2023/2 Dated Guwahati the 2nd Feb 2023
Open Tender
Civil Works - Building
Item Rate
365 days
Tangla
Please refer Tender documents.
4 documents required · 4 mandatory
₹8,000
₹8.1 L
Yes
O/O The CE, PWD (Bldg), Assam, Chandmari, Ghy-3
4 Jul 2023
8 Feb 2023
3 Mar 2023
8 Feb 2023
1 Mar 2023
8 Feb 2023
15 Feb 2023
Amount
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth,1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m as directed by Engineer-in-charge. All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Supplying chemical emulsion in sealed containers including deliveiy as specified. Chlorpyriphos/ Lindane emulsifiable concentrate of 20%
Diluting and injecting chemical emulsion for POST- ONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole :With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dig holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : "1:2:4 (1 cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size drived from natural sources.
Providing and laying in position ready mixed or site batched design mix concrete for plain cement concrete work, using coarse aggregate and fine aggregate derived - from natural sources, Portland Pozzolana / Ordinaiy- Portland / Portland slag cement , admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, to improve durability and workability without impairing strength;' including pumping of concrete to site oflaying, curing, carriage for all leads, but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge for the following grade of concrete. Note : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement Note: (1) Excess/Less cement used than specified in this item is payable/ recoverable separately. (2) Fly ash confonning to grade I oflS 3812 (Part-1) only be used as part replacement of OPC as per IS : 456. Uniform blending with cemeut is to be ensured in accordance with clauses 5.2 and 5.2.1 of IS: 456 -2000 in the items of BMC and RMC." All works upto plinth level: Concrete of M10 grade with minimum cement content of 220 kg/cum
Diluting and injecting chemical emulsion for POST- CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsionl): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration
Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement:3 coarse sand derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Centering and shuttering including strutting, propping etc. and removal of form for all heights : Foundations, footings, bases of columns, etc. for mass concrete
Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams,plinth beams,girders,bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by percussion drilling using Direct mud circulation (DMC) or Bailer and chisel technique by tripod and mechanical Winch Machine all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). 450mm dia piles
Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge / Anchor piles method and preparation of pile head or construction oftest cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge Note: 1. Initial and Routine Load Test shall not be carried out by Dynamic m thod of testing. Note: 2. Testing agency shall submit the design of loading platform for the apprnval of Engineer-in-charge. Group of two or more piles upto 50 tonne Safe capacity Initial test (Test Load 2.5 times the Safe capacity)
Routine test(Test Load 1.5 times the Safe capacity)
Steel reinforcement for R.C.C. work including straightening,cutting. bending. placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-5OOD or more.
Steel reinforcement for R.C.C. work including straightening. cutting. bending. placing in position and binding all complete above plinth level Thermo-Mechanically Treated bars of grade Fe-5OOD or more
Providing and laying in position ready mixed or site batched design mix concrete for reinforced cement concrete work, using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland / Portland slag cement• admixtures in recommended proportions as per 15: 9103 to accelerate/ retard setting of concrete, to imprnve durability and workability without impairing strength;' including pumping of concrete to site of laying. curing. carriage for all leads, but excluding the cost of centering. shuttering , finishing and reinforcement as per direction of the engineer-in- charge for the following grade of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mile is more than 110% of the specified minimum cement content , the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg/cum
All works above plinth level upto floor v level Concrete of M25 grade with minimum cement content of 330 kg/cum
Providing and laying autoclaved aerated cement blocks masonry with 150mm/230mm/300 mm thick AAC blocks In super structure above plinth level up to floor V level with RCC band at sill level an.d lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately)
Providing and laying autoclaved aerated cement blocks masonry with 100 mm thick AAC blocks in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement: 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work.
Extra for providing and placing in position 2 Nos 6mm dia M.S. bars at evervthird course of half brick masonry.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, fucias and similar locations or required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment. epoxy touch ups, induding rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab upto 0.50 sqm
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, fucias and similar locations or required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment. epoxy touch ups, induding rubbing, curing,moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab colour black, Cherry/Ruby red Area of slab over 0.50 sqm
Extra for fixing marble /granite stone, over and above corresponding basic item, in facia and drops of width upto 150 mm with epoxy resin based adhesive, including cleaning etc. complete.
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/stone work,including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
Providing wood work in frames of doors, windows,clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately) Second class teak wood
Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160 /180 nos. 2. Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs. 3. On drying of sealer coat wet rubbing with emery cloth offiner grading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing. then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion. This 1st coat is allowed to dry for 24 hrs then th.is dry surface is again fine wet rubbed smooth, which is further allowed to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray gun using melamine clear polish and melamine thinner mixed in required proportion
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both races of shutters: 35 mm thick including ISI marked Stainless Steel butt hinges with necessarv screws
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessarv screws. 35 mm thick Second class teak wood
Providing and fixing wire gauge shutters using galvanized MS.wire gauge of average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm, for doors, windows and clereston windows with hinges and necessarv screws: 35 mm thick Second class teak wood shutters with ISI marked MS.pressed butt hinges bright finished of required size
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (overall area of door shurrer to be measured).
Providing and fixing chromium plated brass curtain rod having wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc, wherever necessary complete: 25 mm dia
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to JS: 2046 Type S, including cost of adhesive of approved qauality. 1.0 mm thick
Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISi marked fl ush door shutters conforming to IS: 2202 (Part l) On one side only
Providing and fixing approved brand and manufacture SS 304 Lever Handle D-type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture Stainless Steel 304 grade CYLINDRICAL LOCKS - CLASSIC LOCK. Complete in all respects as per manufucturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Tower bolt 300mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufucturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufucture SS 304 grade Tower bolt 250mm long with 10mm dia fixed with SS screws etc. complete in all respects as per manufucturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufucture SS 304 grade wall mounted door buffer fixed with SS screws etc.complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing approved brand and manufacture SS 304 grade Door Stopper - door mounted hanging type fixed with SS screws etc. complete in all respects as per manufacturers' specifications & as directed by Engineer-in-charge.
Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete
Structural steel work riveted,bolted or welded in. built up sections, trusses and framed work, including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer all complete:
Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels. plates etc., including welding. grinding, buffing. polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners,stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in charge) 0.05 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoey primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-incharge. The sheet shall be fixed using self drilling /selftapping screws of size (5.Sx 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surraces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete. 40mm thick with 20mm nominal size stone aggrregate.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25mm thick
Kota stone(Tandoor stone) slabs 20 mm thick in risers of steps, skirting. dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15.622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond rutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/ Antiskid finish of size Size of Tile 600 x 600 mm
Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting. riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) jointing with grey cement slurry@ 3.3 kg/sqm including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600 x 600 mm
Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg) including filling / grouting and finishing complete as per direction of Engineer-in-charge. Size of Tile 600 x 600 mm
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-in-charge. Flooring
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-in-charge. Skirting
Providing and laying Laminate wooden flooring (Grade AC4, 8 mm thick Ambience Premium-AC4 ), having a good backing layer made up of plastic laminate or melamine as specified by the manufacturer and approved by Engineer-in-charge. Floor strip on edges
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown,Cat Eye or equivalent
Providing and fixing 18mm thick Granite stone work for wall lining upto 10 m height in cement mortar 1:3 (lcement : 3 coarse sand) including pointing with white cement mortor with an admixture of pigment to match the granite shade complete as per direction by the Engineer-in-Charge.
Providing and laying machine cut. mirror polished, Italian Marble stone flooring laid in required pattern in linear portion of the building all complete as per architectural drawings, with 18mm thick stone slab laid over 20mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with white cement slurry @ 4.4 kg/sqm including pointing with white cement sluny admixed with pigment to match the marble shade including rubbing. curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge. 18mm thick Italian Marble stone slab,Perlato, Rosso verona, FireRed or Dark Emneradore etc.
MELAMINE LAMINATED WOODEN SLATS PANEL IN on the side walls and rear wall as shown in the drawing Providing and fixing of Anutone Slats - FR Grade made out of pinewood fibreboards, Melamine finish, perforated wooden grooved slats L8-2 - (2mm grooves @ 8mm centers) / L16-2 - (2mm Slats @16mm pitch) / L32-2 - (2mm grooves @ 32mm centres) fL64-2 -(2mm grooves @ 64mm centers), backlined with acoustical fleece, tongue-groove edge for a seamless look, FR grade, of lineal dimension size 128mm x 2440mm x 16mm thick having density 800Kg /m3, weight 10 Kgs/m2, installed by using suspended ceiling system. The ceiling system shall includes GI Wall channel(WC25) having thickness 0.45mm,length 3600mm, unequal flanges of 20 & 30mm and web of 25mm to be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300mm centers. Suspended Main channels (MC45) having thickness 0.9mm, length 3600mm, equal flanges of 15mm and web 45mm from the soffit at every 1200mm centers with Suspender angle (SA25) having thickness 0.45mm, length 3600mm, unequal flanges of 25 & 10mm. GI Cross channel(CC25) having thickness 0.45mm, length 3600mm, knurled web of 50mm, depth of 25mm
Providing and fixing '40mm thick cladding comprising of Wooden framwork using 25mx50mm sections at a maximum spacing of 600mm in any one direction (including adding members as required) covered with12mm thick BWP ply layered with 1 mm thk Laminate(Basic Rate Rs.2S/-sqft)on one side pasted and pressed with adhesive to give a uniform and smooth finish, including top mouldings / margins, melamine polish etc. to finish the thickness, as shown complete in drawing. All members / ply etc. shall be treated with anti-termite solution as per norms.No extra shall be paid for making of openings, door/window frames and for making provisions for electric conduits.
12 mm cement plaster of mix : 1:6 ( cement: 6 fine sand )
15mm cement plaster on the rough side of single or half brick wall of mix: 1:6 ( cement: 6 fine sand )
6 mm cement plaster of mix: 1:3 (1 cement: 3 fine sand)
18 mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster 1:3 (1 cement : 3 coarse sand) finished rough with sponge.
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5 m above floor level, over first class kail wood strips 25x6 mm with 10mm gap in between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to be paid separately) Flat surfaces
Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous) ceiling
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Finishing walls with textured exterior paint of required shade: New work (Two or more coats applied@ 3.28 ltr/10 sqm) over and including priming coat of exterior primer applied @2.20kg/10 sqm.
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Painting with synthetic enamel paint,having VOC (Volatile Organic Compound)content less than 150 grams/ litre,of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats.
Providing & fixing 150mm wide Chicken wire mesh on joints of RCC & Brick work before plastering complete in the direction of Engineer·in-charge.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc. by applying cement slurry mixed with water proofing cement compound consisting of applying: (a) First layer of slurry of cement@ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement@ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
Providing and laying broken AAC Block in sunken portion of W.C. & kitchen.These broken Block mixed with cement mortar 1:8 ( 1 cement : 8 coarse sand) laid and compacted properly including supply of labour, material, and tools and plant etc. as per instruction of Engineer-in-charge.
Supply and Fixing of High Pressure Compact Laminates (HPL)ceiling or a Panels European norm compliance of CE mark With Electron Beam Curing (EBC) having standard dimension of 2800x1300x6mm or 3050x1300x6mm and fixing of frame work made of GI angle 2Sx25x0.4 mm thick all around suitably futed to wall with the help of dash fastener and hanger frame (600x600 c/c) made GI slotted Tee having powder coating on bottom side (30x25x0.3 mm thick for main member & 25x25x0.3 mm for cross member) connected to ceiling With 2.64mm GI wire and anchor fastener at every junction and also including cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed all complete as per direction of Engineer-in-charge.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting ol fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 510x1040 mm, bowl depth 200mm.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting ol fittings and brackets, cutting and making good the walls wherever required: Kitchen sink with drain board 610x510 mm, bowl depth 200mm.
Providing and fixing CP Brass 32mm size·Bottle Trap of approved quality & make and as per the direction of Engineer in-charge.
Providing and fixing CP Brass Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. 15 mm nominal dia
Providing and fixing P.V.C. Waste pipe for sink or wash basin including P.V.C. waste fittings complete. 40 mm dia
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality)complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings wooden cleats with CP brass screws with concealed fittings. 600 mm long towel rail with total length of 645 mm,width 78 mm and effective height of 88 mm, weighing not less than 190 gms.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 Iitre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china battery based infrared sensor operated urinal of approx. size 610 x 390 x 370 mm having pre &post flushing with water (250 ml & 500 ml consumption), having water inlet from back side, including fixing to wall with suitable brackets all as per manufacturers specification and direction of Engineer-in-charge.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931: 15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 15 mm nominal bore
Providing and fixing C.P. Brass extension nipple (size 15mmx50mm) of approved make and quality as per direction of Engineer-in charge.
Providing vitreous china counter top wash basin size (635 x 390 x 140mm) of Parryware modal C0457·semi-Insert with 32 mm CP brass waste coupling of standard pattern, C.P. brass chain with plug. PVC waste pipe including painting of fittings and brackets, cutting and making good the walls and slabs wherever required. White vitreous china counter top wash basin with CP Brass Single Lever Basin Mixer.
Providing vitreous china counter top wash basin size (635 x 390 x 140mm) of Parryware modal C0457·semi-Insert with 32 mm CP brass waste coupling of standard pattern, C.P. brass chain with plug. PVC waste pipe including painting of fittings and brackets, cutting and making good the walls and slabs wherever required. White vitreous china counter top wash basin with CP Brass Single Pillar Cock.
Providing and fixing 15 mm C.P brass Sink Mixer for kitchen sink of Parryware Model. No.T39SOA1 with swinging spout complete. Including cutting and making good the walls wherever required .
Providing and fixing 15mm C.P. copper connecting pipe 450mm longof Parryware modal T991299 with C.P. brass nuts, washers complete in all respects.
Providing and fixing health faucet with 1 m long of Parryware modal T9807A1 flexible tube and wall hook including all fittings .
Providing and fixing of C.P. brass Soap Dish fixed with C.P. brass screws complete in all respects.
Providing and fixing vertical storage type hot water heater fixed to wall with anchor bolts & nuts, 15mm CP brass angle stop cock and 15mm CP brass non- return valve complete including making connections with 15mm dia CP connecting pipes on inlet and outlet, suitable length of power cable and 15 amps plug (Venus or approved equivalent). Capacity 25 Litres
Providing and fixing C.P. brass 15 mm nominal bore two way bib cock.
Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering. All work up to plinth. 1:2:4 ( 1cement : 2 Coarse sand : 4 graded stone aggregate 20 mm nominal size )
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet lmx1mx400microa, finished with 12mm cement plaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grms.
Providing and fixing soil, waste and vent pipes : l00 mm dia Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick,bolts & nuts complete. l00 mm dia Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Providing and fixing plain bend of required degree. l00 mm dia Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Providing and fixing heel rest sanitary bend. l00 mm dia Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. 100 x 100 x 100 mm Sand cast iron S&S as per IS· 3989
Providing and fixing terminal guard. l00 mm Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Providing and fixing shieled coupling for Hubless centrifugally cast iron pipes. l00 mm ISS 304 grade coupling with EPDM rubber gasket.
Providing and fixing MS Stay clamps for sand cast iron/centrifugally cast(spun) iron pipes of diameter. l00 mm
Providing and fixing trap of self cleansing design with screwed down or hinged with or without vent arm complete, including cost of cutting and making good the walls and floors. l00 mm inlet and 100mm outlet Hubless Centrifugally cast (spun) Iron pipes epoxi coated inside & outside S&S pipe IS:15905
Painting sand cast iron/ centlifugally cast (spun) soil, waste, vent pipes and fittmgs with paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work. l00 mm dia pipe
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 32 mm dia. nominal bore
Providing and fixing G.I. pipes complete with G.I. Fittings and clamps, including cutting and making good the walls etc. (Internal work) 50 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti- corrosive bitumastic paint of approved quality. 32 mm dia. nominal bore
Painting GI pipes and fittings with two coats of anti- corrosive bitumastic paint of approved quality. 50 mm dia. nominal bore
Providing and fixing of GI clamps with EPDM rubber lining Zinc plated for support of vertical soil, waste, vent and rain water pipes, embedded in walls with anchor fastner etc. including cost of cutting holes and making good the walls complete in all respects. 100 mm dia
Providing and fixing in position 100x50 mm dia GI reducing elbow including fix to floor with cement mortar.
Providing and fixing in position 125x125 mm stainless steel grating for floor trap/floor drain including fix to floor with cement mortar.
Providlng and fixing 100 mm dia GI inlet fitting/ Extension Piece with 2 or 3 inlets of 32 to 50 mm dia, fixed to CI trap with lead joint and set in cement concrete as per drawing complete.
Providing and fixing uPVC agricultural pipes conforming to IS:4985 (6 kg/sqcm) including all fittings, e.g couplings, tees, bends, reducers and screwed adoptors jointing with solvent cement joint as per manufacturers' recommendations. (for Rain Water Pipes) 110 mm OD
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC} pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/ c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc. 20 mm nominal outer dia pipes.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC} pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/ c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge Concealed work including cutting chases and making good the walls etc. 25 mm nominal outer dia pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls etc. Internal work - Exposed on Wall 20 mm nominal outer dia .Pipes.
Providing and fixing G.I. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls etc. Internal work - Exposed on Wall 25 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls etc. Internal work - Exposed on Wall 32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls etc. Internal work - Exposed on Wall 40 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps. i/c cutting and making good the walls etc. Internal work - Exposed on Wall 65 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 40 mm dia nominal bore
Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) for stop cock, with C. I. surface box 100X100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessaiy excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size ) and inside plastering with cement inortar 1:3 (1 cement : 3 coarse sand) 12mm thick finished with a floatinig With common burnt clay F.P.S.(non modular) bricks of class designation 7.5
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat both of approved quality for new work 20 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat both of approved quality for new work 25 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat both of approved quality for new work 32 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat both of approved quality for new work 40 mm dia nominal bore
Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat both of approved quality for new work 65 mm dia nominal bore
Painting G.I. pipes and fittings with two coats ofanti corrosive bitumastic paint of approved quality: 40 mm dia nominal bore
Providing and filling sand of grading zone V or coarser grade, all round the G.I. pipes in external 40 mm dia nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank.IS:12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Supplying, fixing. testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 65 mm dia
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female RSP threads complete in all 20 mm dia nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female RSP threads complete in all 25 mm dia nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female RSP threads complete in all 32 mm dia nominal bore
Providing and fixing forged brass ball valve of brass body with hard chrome plated steel ball inside PTFE (Teflon) seat & ring with chrome plated centre handle with female RSP threads complete in all 40 mm dia nominal bore
Providing and fixing Thermoflex or Kaillex thermal insulation tubbing a elastomeric flexible material having hermetic blister closed cell structure of expanded synthetic rubber over pipes of following nominal bores and thickness including all required accessories complete as per specification. 6 mm thick (Concealed Pipes) 20 mm dia pipe
Providing and fixing forged brass single acting air release valve with screwed inlet 25 mm dia
Providing and fixing of Single phase electrical actuator operated wafer type rubber lined butterfly valve with by pass arrangement as per drawing attached including level controller, 3 nos. normal butter fly valves.necessary control and Power cables ( Maximum 10 M. Length of each type) and control panel installed on OH tank filling line near the tanks complete in all respects. 40 mm dia
Providing and fixing threaded end brass digital water meter complete in all respects. 40 mm dia
Providing. laying. testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding. fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable damp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia
Providing. laying. testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding. fittings like elbows, tees,flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable damp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 25 mm dia
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/ gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required: 80 mm dia
Providing. installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts.washers etc as required: 80 mm dia
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required: 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS:12585 20 mm nominal internal dia gun metal globe valve & Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket 40 m
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case as required: 25 mm
Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with MS suspenders including bolts & nuts painting 1150 mm widthx50mm depthx 1.6 mm thickness.
Providing and fixing carbon-di-oxide type fire extinguishers consisting of pressure tested single cast cylinder with rotary discharge valve and high pressure discharge tube of minimum 1 m length. discharge horn, suspension bracket conforming to IS:15683·-finished externally with red enamel paint and fixed to the wall with brackets Capacity 4.5 kg
Providing and fixing ABC Powder type fire extinguishers consisting of welded M.S. cylinderical body, squeeze lever discharge valve fitted with pressure indicating guage internal discharge tube 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket conforming to IS:15683 finished eltternally with red enamel paint and fixed to wall with brackets complete with internal charge. (Halon Free Gas) Capacity 6.0 kg
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs comolete in all respects. Power cable 3.5 core 150 sqmm aluminium conductor armoured cable
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs comolete in all respects. Power cable 3 core 16 sqmm aluminium conductor armoured cable.
Providing and fixing heavy duty PVC insulated, PVC armoured conductor cables 1100 V grade including necessary support clamps and connection lugs comolete in all respects. Control cable cooper 2 core 1.5 sqmm
Wiring for light point/ fan point/ exhaust fan point/ call bell point With 1.5 sq.mm FRLS PVC Insulated copper conductor single core cable in surface / recessed steel conduit; with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
Wiring for twin control light point with 1.5 sq.mm FRlS PVC insulated copper conductor single core cable in surface / recessed steel conduit, 2 way modular switch, modular plate, suitable GI box: and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc.
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable In surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC Insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submaln wiring alongwith earth wire with the following sizes of FRLS PVC inrulated copper conductor, single core cable In surface/recessed steel conduit as required. 2 X1.5 sq. mm+1 X1.5 sq. mm earth wire
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required 6x1.5 sq.mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required 25mm
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch. connections etc. as required
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and flxing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connections etc. as required
Supplying & Fixing call bell suitable for single phase,230V complete as required
Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed Steel / PVC conduit as required 1 run of cable
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit; and earthing the point with 1.5 sq. rnm FRLS PVC insulated copper conductor single core cable etc. as required. Group-A
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or In recess. including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc.. as required
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 2 X4 sq. mm+ 1X4 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 2 X6 sq. mm+ 1X6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 2 X10 sq. mm+ 1X6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 4 X6 sq. mm+ 2X6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 4 X10 sq. mm+ 2X6 sq. mm earth wire
Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed steel conduit as required 4 X16 sq. mm+ 2X6 sq. mm earth wire
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required 2 Pair
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required 20mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required 25mm
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required 32mm
Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required Telephone socket outlet
Supplying and fixing of following modular switch / socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required TV antenna socket outlet
Supplying and fixing following size/ modules, Gl box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75 mmX75 mm)
Supplying and drawing following pair 0.5mm dia FRLS PVC insulated annealed copper conductor, armored telephone cable in the existing surface/ recessed steel /PVC conduit as required 10 Pair
Supply Installation and testing and commissioning of follwing size o Telephone distribution board in a MS. box with hinged cover/ door complete with kroue type tag block with double jumpering facllity mounted on a bakelite sheet etc. including termninations of cable as required 10 Pair telephone distribution board
Supply and laying of coaxial cable RG-59 in existing conduit complete as required.
Supply, erection, testing & commissioning of following sizes of splitters of aluminium die cast body. 6 Way
Supply and fixing of following modular switch socket on the existing modular plate & switch box including connection but excluding modular plate and Modular box etc as required. 20 Amp DP Switch
Supply and fixing of following modular switch socket on the existing modular plate & switch box including connection but excluding modular plate and Modular box etc as required. 20 Amp Socket Outlet
Supply and fixing of universal shaver socket unit (vertical) with dual voltage sockets (230 Volts & 110 Volts), inbuilt Isolation transformer with safety overload protection with reset feature, auotmatic switch ON/OFF on inserting / removal of plug. indicating light for power ON status with safety shutters complete with Modular base and cover plate and GI Box.
Supplying and fixing following way, Vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with tinned copper bus bar,neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ lsolator) 12 way (4 + 36), Double door
Supplying and fixing following way, Vertical type TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with tinned copper bus bar,neutral link, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB /RCCB/ lsolator) 8 way (4 + 24) Double door
Supplying and fixing following way,single pole and neutral, sheet steel MCB distribution board,240 V,on surface / recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required(But without MCB /RCCB/ lsolator) 16 way, Double door
Supplying and fixing following way,single pole and neutral, sheet steel MCB distribution board,240 V,on surface / recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc. as required(But without MCB /RCCB/ lsolator) 12 way, Double door
Supplying and fixing following rating. double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 40 A
Supplying and fixing following rating. double pole, 240 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required 63 A
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB),having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps
Supplying and fixing following rating, four pole, 415 V, MCB In the existing MCB DB complete with connections,testing and commissioning etc. as required. 40 Amps
Supplying and fixing following rating, four pole, 415 V, MCB In the existing MCB DB complete with connections,testing and commissioning etc. as required. 63 Amps
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C' curve, miniature circuit breaker suitable for inductive load of followiog poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole
Supplying and fixing single pole blanking plate in the existing MCB DB comnlete etc. as required.
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 100 mm width X 50 mm denth X 1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 150 mm Width X 50 mm denth X1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 100 mm width X 50 mm denth X 1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "bends" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 150 mm Width X 50 mm denth X1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Tee" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 100 mm width X 50 mm denth X 1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Tee" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 150 mm Width X 50 mm denth X1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Cross member" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 100 mm width X 50 mm denth X 1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Cross member" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 150 mm Width X 50 mm denth X1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Reducer" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 100 mm width X 50 mm denth X 1.6 mm thickness
Supplying and installing following siZe of perlorated Hot Dipped Galvanised Iron cable tray "Reducer" (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, Joined with connectors, suspended from the ceiling with G.L suspenders lncluding G.I. bolts & nuts etc. as required. 150 mm Width X 50 mm denth X1.6 mm thickness
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning. protective covering and refilling the trench etc. as required. Upto 35 sq. mm
Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning. protective covering and refilling the trench etc. as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/METAL pipe as required. Upto 35 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing RCC/ HUME/METAL pipe as required. Above 95 sq. mm and upto 185 sq. mm
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
Laying of one number PVC Insulated and PVC sheathed / XLPE power cable of 1.1 kV grade of following size in the existing masonry open duct as required. Above 95 sq. mm and upto 185 sq. mm
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 3½X150 sq.mm (50 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 3½X35 sq.mm (32 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 4X25 sq.mm (28 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 4X16 sq.mm (28 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 4X10 sq.mm (25 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 2X10 sq.mm (19 mm)
Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XI.PE aluminium conductor cable of 1.1 KV grade as required. 2X6 sq.mm (19 mm)
Supplying and laying of following size DWC HOPE pipe ISI marked along with all accessories like socket, bend, couplers etr. conforming to IS 14930, Part 11 complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering as required. 120 mm dia (OD-120 mm & ID-103 mm nominal)
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 3.5 core 150 Sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 4 core 25 Sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 4 core 16 Sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 4 core 10 Sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 2 core 10 Sq.mm.
Supply of following size of 1.1KV grade multicore aluminium conductor XLPE insulated PVC sheathed armoured power cable as per IS:7098 (Part-1) 1988 complete as required 2 core 6 Sq.mm.
lnstallation of exhaust fan in the existing opening,induding making good the damage, connection, testing. commissioning etc. as required. Upto 450 mm sweep
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.Ssq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required
Supply, Installation, Testing & Commissioning of Cylindrical suspended Iuminaire with 2000 mm cable suspension made from aluminium; surface white or black powder coated; passive cooling of LEDs With optimised heat sink geometry; COB(Chip on Board)technology for maximum efficiency; 110 formation of multiple shadows; energy-efficient LEDs with high colour rendering; binning< 3 step MacAdam; available in the light colours 3000 K, 4000 K and 5000 K; CRI > 80; min. BO % of the luminous flux airer 50,000 hours; high quality reflector with spherical facet finish; precise radiation characteristic with three different beam angles; instilled and exchanged without tools; protection class IP 20; PC!; optional with DALI or phase-cut dimmable Equivalent: XAI., WIPRO, TULIP, ERCO, ACUITY
Supply, of surface mounted linear fixture (1200mm*300m.m length approx) RCA housing with white epoxy powder coated and high quality polycarbonate opal diffuser with electronic driver,IP- 20,THD<10%, rated life of L-70@50000hours having minimum lumen output of 3000 lumens and efficacy better than 85 Jumens/watt indudlng making suitable arrangement for fixing on ceiling & connection with 3x:t.Ssq.mm PVC insulated FRLS PVC sheathed copper conductxir ID flexible GI conduit with fitting accessories as required.
Supply, Installation, Testing &.Commissioning of Surface/recess type LED downlighter neutral white (4000 KJ with LED having pressure die cast aluminium hang body having high effidencydiffuser with more than 85% transmittance with rated life of L-70 @ 50000 hrs having system lumen output better than 1150 Jumens and efficacy better than 100 lumen/ watt(fixture design for meeting LG-7 Guideline) with CRl>SO, Reverse Polarity and Surge Protection upto 3kV& Driver efficiency> 90%,PF>0.98,THD<5% (DriVer complaince IEC 62384,IEC 61547,IEC61347-2-13,EMI-CISPRlS) etc.OR equivalent including making suitable arrangement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm.PVC Insulated FRLS PVC sheathed copper conductor in flexible.GI conduit as required.
Supply, Installation, Testing & Commissioning of Recess/Surface type Dimmable(DALl)LeD downlighter neutral white (4000 K) With LED having pressure die cast aluminium hang body having high efficiency diffuser with more than 85% transmittance·with rated life of L-70 @50000 hrs having system lumen output better than 3000 lumens, with LG-7 Louver and efficacy better than 100 lumen/ watt(fixture design for meeting LG-7 guideline) with CRl>SO & Driver efficiency > 90% (Driver complaince IEC 62384,IEC 61547,IEC 61347-2- 13,EMI-CISPR15,THD<5%,PF>0.95 ) etc. with inbuilt protection against short circuit ,Miswiring.over voltage and surge protection upto 3 KV.OR equivalent including making suitable arrengement for fixng on wall/ceiling & connection with 3x1.5 Sq.mm. PVC Insulated FRLS PVC sheathed copper conductor in flexible GI conduit as required.
Supply, Installation, Testing & Commissioning of Recess/Surface type LED downllghter neutral white (4000 K) with LED having pressure die cast aluminium hang body having high efficiency diffuser with more than 85% transmittance with rated life of L-70 @50000 hrs having system lumen output better than 3000 lumens, with LG-7 Louver and efficacy better than 100 lumen/ watt(flxture design for meeting LG-7 guideline) With CRl>BO & Driver efficiency > 90% (Driver cornplaince IEC 62384..(EC 61547,IEC 61347-2- 13,EMl-□SPR15,THD<5%,PF>0.95) etc. with inbuilt protection against short circuit Miswiring. over voltage and surge protection upto 3 KV.OR equivalent Including making suitable arrengement for fixing on wall/ceiliug & connection with 3x1.5 Sq.mm. PVC Insulated FRLS PVC sheathed copper conductor In flexible GI conduit etc. as required.
Supply, Installation, Testing & Commissioning of LED Intelligent Batten Fixture wtth Body made up of Extruded Aluminium Housing and having In gress Protection of IPZO having Lumen liffldency>lOOlpw with Inbuilt Protection against Short CircuitMiswiring. Over Voltage, Reverse Polarity and Surge Protection upto 3 kV, THD< 5%, UGR<l9, CRl>BO. The Length of the Fixture should be 1200mm with Avg Life of Fixture 50,000 @ L70. The Fixture should have Inbuilt Motion Sensor along with RF and is Equipped with Remote Brightness Control, Dimming ON/OFF.
Provide and install Red/ Green LED Laser etched emergency exit slgnages double/single sided pendant type made out of powder coated MS housing and etched aciy!lc sheet Indicator with reflective light sauce > 2W LED, Emergency Backup of minimum 4 hours, 6V 3.2 AH SMF/ SI.A battery, SMPS Power supply suitable for operation on 230 AV 50 Hz AC supply as per the requirement at all prominent locations to guide the way out of the building to the building users in cas of fire
Supply, Installation, Testing & Commissioning of Round lumlnaire bouslag made from aluminium; for trimless Installation in plasterboard ceilings; special edge design Wlth grooves for better adhesion of filler, suitable for ceiling thickness of 10-25 mm; surface white powder coated; up to 1250 mm: LED circuit board with highly reflective coating for improved efficiency; laset consisting of converter unit and PCB unit; mechanical and electrical connection Without tools using twist closure and reverse polarity protected plug system; completely homogeneously illuminated, satinlsed PMMA cover, cover removable without tools for easy malatellilllce; energy- efficient LEDs with hlgh colour rendering; available in the light colours 3000 K. 4000 Kand 5700 K; CRI > 80; min. 90 % of the luminous flux after 50,000 hours; protection class IP 20; PC I; optional DIM 1-l0V or DAU dimmable Equivalent: XAl. WIPRO, TULIP, ERCO, ACUIT
Supply, Installation, Testing & Commissioning of Neutral white(4000 K) LED Strip having Light output of 1000 Lumensper metre and system efficacy better than 65 Lumens per Watt with driver OR equivalent including making suitable arrengement for fixing on wall/ceiling & connection with 3x1.5 Sq.mm. PVC insulated FRLS PVC sheathed copper conductor in flexible GI conduit etc. as required.
Supply, Installation. Testing & Commissioning of 24V Surface Mount Linear fixture for wall washing and graz!og application. The length of the fixture should be around 500mm. The housing should be made of extruded anodized aluminium. The protection rating of the fixture should be of IP65. Delivered lumens should be more than 1000 lumens. Luminous efficacy of the fixture should be more than 110 lm/W. The fixture should have Wide elliptical beam distribution around 30" X 60". CCT of the fixture should be 2700K or 3000K or as per requirement of the architect. Color Rendering Capability of the fixture should be more than 80. Fixture dimension should be around 500mm length X 50mm width X 95mm height and Location Entrance Gate & Bus Stop. Equivalent: Heper,Es System. Litolux
Supply, lnstallation. Testing and Commissioning of 1200 sweep. BEE 5 star rated, ceiling fan with Brush less direct current (BLDC) motor, class oi insulation B, 3nos. blades, 30cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding. power factor not less than·0.9, service value(CMM/W) minimum 6.8S, Air deliveiy minimum 215 CMM, 350 RPM (tolerance as per IS: 374-2019). THD less than 10% to be operate by electronic regulator unit for speed control and all remaining accessories including safely pin, Nut bolts, washers, temperature rise=75 degree c (max.), insulation resistance more than 2 mega Ohm, snltable for 230V, 50Hz, single phase AC supply, earthling etc. complete as required
Supply of following sizes of Heavy duty Exhaust fan with Louver suitable fur operation on single phase 230 Volt AC 50 Hz supply complete with all fixing accessories as required. 300 mm Sweep (900 RPM)
Supply, installation, testing and commissioning of cabin fans of 1350RM made of high quality engineering plastic complete with all accessories as required In the follouwing sizes:- 400 mm Sweep
Supply, Installation, Testing Comraissioing of Sine Wave INVERTER. fully digital type and shall be based on PWM technique with following key features -Wide input voltage range 230V - 20% + 15 % and wide frequency SOHz +10%.Three Phase lnput / Three Phase output.INVERTER shall be static without any moving parts.PWM technioue shall be used for producing AC output from DC input.Efficiency of the Inverter shall be neater than 85%.utput wave form shall be pure sine Wave with harmonic distortion less than3%.Output wave form shall be pure sine Wave with harmonic distortion less than3%. Inverter shall be suitable for maximum ambient temperature of 60°c and acoustic noise at 1 Mtr shall be less then 55dB.Inverter shall have minimum oflP20 protection.The Inverter shall·be complete with 90 minutes power backup on full load.Battery shall be sealed maintenance free type with suitable rack and connectors. 2.0 KVA
Supply,Transportation. storing at site, shifting at work place, installation, Testing and commissioning of the following rating UPS as per spectficatioas and complete in all respects.The scope also includes supply, Installation. Testing and Commissioning of Sealed Maintenance Free lead acid Batteries complete with intercell connetors & copper cables, batterystand made out of Powder Coated MS Angles with adequate supports to cany the load o the batteries.& also TVSS at the input of each UPS to protect against transients, surges & Noise as per the tender specifications2 Nos. 10 KVA UPS in parallel mode with 15 minutes battery back up with static & manual bypass Input Voltage: 3 Ph 415 Volts, ±10% Output:3 -Phase-415Volts 50 Hz +2%
Supply & fixing of Rubber hand gloves 11 KV Tested.
Supply & fixing of glass framed shock treatment chart both in Hindi & English for treating person suffering due to electric shock mounted on wall hooks.
Providing & fixing of Carbon d!oXide (CO2) type fire extinguishers conforming to IS 2878-1976 and cylinder fully charged of 4.5 Kg capacity hanged on wall with bracket romponent as required.
Supply and fixing safety instruction chart in word duly framed with 5mm thick glass as required. (Approx Front area 1.20 sq mt )
Providing of set of 4 Nos. 9.5 Litre capacity GI bucket painted in post office red colour with prior coat of red - oxide paint and written with white paint 'Fire' and mounted on MS angle iron frame with bracket of appropriate size and capacity including filling sand etc.
FirstAid box as approved by St John Ambulance Brigade/ Indian red Cross conforming IS 2217 -1963
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of 2.0 mm thick +/-10% confinning to BIS: DOC NO. ET-02 (5440) meeting requirments of IS: 15652 :2006 (with upto date amendment), suitable for all voltages not exceeding 3.3 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirements.
Supply & fixing of fire retardant/ extinguishing Electrical insulated synthatic mat of minimum 3.0 mm thick +/-10% confirmlng to BIS: DOC NO. ET-02 (5440) meeting requirments of!S: 15652 :2006 (with upto date amendment}, suitable for all voltages not exceeding 33 KV and having minimum width of 1000 mm +/- 20mm and including supply of required quantity of adhensive/ compound and fixing the same at size as per site requirements.
Providing aod fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on frontside as required.
IP BULLET CAMERA Supply installation. testing & commissioning of 3Mpx Indoor dome 2048 x 1536 at 30fps, Autofocus Motorized remote zoom lens 2.8 - 8 mm, H.265/IU64 compression, 40 mtr AdaptiVe JR, 120dB • Minimum llluminator @Fl.4 0.13 lux color; 0.01 lux Mono, 3D noise filtering. Bi directional Full Duplex Audio, inbuilt mic, 1 Alarm In. 1 Alarm out, 3 independant stream, Soos of configurable privacy mask, Supported protocol - TCP/IP, lpv4 & IPv6,UDP/IP, DNS, DDNS,ARP, lCMP, lGMP, RTCP, SFI'P, SIP, TLSfITLS, ARP.802.lx (EAP-MDS, EAP-TLS, EAP·TIU, EAP PEAP and RAP-FAST). Edge based analytics -Object Counting, AdaptiVe Motion, Object Removal. Motion Detection, Camera Sabotage, Audio Detection, and Directional Motion. Camera shall features of Corridor mode, Mirror mode, having SD card provision of 128 GB, Operating temperature - 10 to +SO deg C,IP64 ,IKlO,Worl<s on PoE+,ONVIF profile S,G & T,Cybersecrutiy Cert:UL/NDAA, CE • EN 55032 (Class A), EN 50130-4, EN 60950-1,FCC (Class A) - 47 CFR Part 15,UL and cUL Listed - UL 60950-1, CAN/CSA-C22.2 No. 60950-1-07, BIS certified.to ruggedized performace as per site requirements.
IP DOME CAMERA Supplying. installation, testing & commissioning of 3Mpx Indoor dome 2048 x 1536 at 30fps, Autofocus Motorized remote zoom lens 2.8 - 8 mm. H.265/H.264 compression, 40 mtr Adaptive IR. 120dB . Minimum nluminator @Fl.4 0.13 lux color; 0.01 lux Mono, 3D noise filtering. Bi directional FuU Duplex Audio, inbuilt mic, 1 Alarm In, 1 Alarm out, 3 independant stream, Snos of configurable priva -y mas!(. Supported protocol -TCP/IP, Ipv4 &1Pv6,UDP/IP, DNS, DDNS,ARP, ICMP, IGMP, RTCP SFI'P, SIP, TLSjTTLS, ARP.B02.lx (EAP-MDS, EAP·TLS, EAP-TILS, EAP· PEAP and RAP-FAST). Edge based analytics -Object Counting. Adaptive Motion, Object Removal, Motion Detection, Camera Sabotage, Audio Detection, and Directional Motion. Camera shall features of Corridor mode, Mirror mode, having SD card provision of 128 GB, Operating temperature - 10 to +SO deg C,IP64 ,!KlO,Works on PoE+,ONVIF profile S,G & T,Cybersecrutiy Cert:UL/NDAA, CE - EN 55032 (Class A1 EN 50130-4, EN 60950-1,FCC (Class A}· 47 CFR Part 15,UL and cUL Listed - UL 60950-1, CAN/CSA-C22.2 No. 60950-1-07, BIS certified.to ruggedized performace camera should meet Shock & Vibration Certifcation:IEC 60068:2-6 and 2-27
Supply, installation, testing and commssioning 12 volt 2 Amp Power Adaptor -12 Volt DC with 2AMP Power Supply
IP PHONE Supply, installation, testing and commissioning 128 _x64 B&W graphical display with Backlight, 2-port Gigabit Ethernet Switch, Power over Ethernet class 1 for low power consumption, 6 Softkeys, alpha numeric Keyboard.Navigator: 4-way navigation, 01(. cancel keys, Programmable keys, Lighted keys and notifications (Incoming calL message, audio control, programmable keys),Widebaild G722, G711 (A-Jaw and Mu-law), G729 AB, voice actiVity detection (VAD),2 SIP accounts.Phone operabilll;y from -5 to 45C
WIFI SYSTEM Supply, installation, testing and commissioning the WLAN solution shall propose a 802.11ac wave2 indoor dual-radio AP (2GHz, 5GHz) Access Point, The Access Point shall have integrated omnidirectional antennas. The Access Point shall support up to 16 SSIDs (8 per radio). The MTBF for the Access Point shall be at least 80+ Years.The Access Point shall offer up to 867Mbps throughput on the SGbz band and up to 400Mbps throughput on the 2.4 GHz Band
INDOOR RACK- 4 U RACK Supply, Installation, Testing & Commissioning of Wall Mount Side Integrated Economics Riveted - 04U - 550W • 4500 - Single Fan Provision - Pastal Fine Tex.,ACCESSORIES INCLUED IN EACH RACK ARE:Single Fan For WallMount; Metal Cable Manager - O1U - Plastic Cable Loop's Mountable - Black Fine Tex. -Assembly, HARDWARE PKT 20SET,PDU 6A 4SKT SWT PLG A
Supply, Installation, Testing & Commissioning of L2 switch with 8 x 1G Base T Port PoE+ with 2 x 1G SFP and 2 IG Base T port, The switch must be stackable uptn 4 Units, Switching Capacity should be 40 Gbps or more with not less than 35 Mpps Throughput ,Switch should have 1GB Flash and 1GB RAM ,The swttrh must support minimum 16K MAC address entries and 4K VLAN with latency of less than < 4 us
Supply , Installation,testing and commissioning of I/O with faceplate & Gang Box
Supply , Installation,testing and commissioning of Cat6 patch code 1 Mtr
Supply , Installation,testing and commissioning of Cat6 patch code 2 Mtr
Supply , Installation,testing and commissioning of Cat6 patch code 3 Mtr
Supply , Installation,testing and commissioning of 24 core Fiber Cable - Single Mode
Supply , Installation of HDPE Pipe- 40 MM
Supply , Installation of Under ground Cable Laying with HDPE Pipe
Supply Installation Testing & Commissioning of SFP Module - 1000Base-LX Gigabit Ethernet optical transceiver SFP MSA). Supports single mode fiber over 1310nm wavelength nominal) with an LC connector. Typical reach of 10 Km on 9/125 m SMF.
Supply , Installation,testing and commissioning of L2 switch with 24 x lG Base T Port PoE+ with 2 R)45/SrP combo port and 2 x 1/lOG SFP+ ,The switch must be stackable upto 4 Units , Switching Capacity should be 90 Gbps or more with not less than 135 Mpps Throughput ,Switch should have 1GB Flash and 1GB RAM, The switch must support minimum 16K MAC address entries and 4K VLAN with latency of Jess than< 4 µs, Switch shall conform to standards
Supply , Installation,testing and commissioning of Electric Power Cable 2* 1.5 Sq mm
Supply , Installation,testing and commissioning of 3 Pin top(Plug)
Supply , Installation,testing and commissioning of Power Board with 6 socket
Supply , Installation,testing and commissioning of 55" LED TV- LED TV should be Professional with HDMI Port
Supply, installation, testing and commissioning of SFP Module· 1000 Base- LX Gigablt Ethernet optical transceiver SFP MSA). Supports single mode fiber over 1310nm wavelength nominal) with an LC connector. Typical reach of 10 km on 9/125 m SMF
Supply , installation, testing and commissioning of 24 Port Cat 6 Patch Panel • Universal mounting of all cabinets or enclosures, Panel: DC01 galvanised sheet steel. Operating temperature: -40°C to+ 70°C
Supply, Installation, testing and commissioning of inverter type Split Cooling units as per specifications and complete as required. Outdoor untts with rotary/scroll compressor air-cooled condenser coll With fan, casing. MS-stand, cabling and earthing as required. Indoor units shall consist al centrifugal fan with motor, dx-cooling coil of copper tubes and aluminium fins, casing. filter, full charge of gas and oil, control wiring. including 3m interconnecting refrigerant piping of suitable size between indoor and outdoor unit. cooling thermostate control wiring etc complete for functional. Note : Aluminium Fins and copper tubes of Air Cooled Condenser along with copper tubing/ piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. a) 1.0 TR HI-wall Unit
Supply, Installation, testing and commissioning of inverter type Split Cooling units as per specifications and complete as required. Outdoor untts with rotary/scroll compressor air-cooled condenser coll With fan, casing. MS-stand, cabling and earthing as required. Indoor units shall consist al centrifugal fan with motor, dx-cooling coil of copper tubes and aluminium fins, casing. filter, full charge of gas and oil, control wiring. including 3m interconnecting refrigerant piping of suitable size between indoor and outdoor unit. cooling thermostate control wiring etc complete for functional. Note : Aluminium Fins and copper tubes of Air Cooled Condenser along with copper tubing/ piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. b) 1.5 TR Hi-wall Unit
Supply, Installation, testing and commissioning of inverter type Split Cooling units as per specifications and complete as required. Outdoor untts with rotary/scroll compressor air-cooled condenser coll With fan, casing. MS-stand, cabling and earthing as required. Indoor units shall consist al centrifugal fan with motor, dx-cooling coil of copper tubes and aluminium fins, casing. filter, full charge of gas and oil, control wiring. including 3m interconnecting refrigerant piping of suitable size between indoor and outdoor unit. cooling thermostate control wiring etc complete for functional. Note : Aluminium Fins and copper tubes of Air Cooled Condenser along with copper tubing/ piping with all joints and U-Bends exposed to coastal areas corrosive atmosphere / aggressive ambient, shall be painted with special corrosion prevention coating either in factory or at site. c) 2.0TR Hi-wall Unit
Supply Installation, testing and commissioning of Interconnecting refrigerant copper pipe work (between indoor and outdoor units as per specifications) with (19mm/13mm thick) dosed cell elastomeric nitrile rubber tubular insulation. All piping Inside the room shall be properly supported with MS angle, including cutting chases, holes in walls/slabs and making them good after installation. a) 6.4mm dia (OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
Supply Installation, testing and commissioning of Interconnecting refrigerant copper pipe work (between indoor and outdoor units as per specifications) with (19mm/13mm thick) dosed cell elastomeric nitrile rubber tubular insulation. All piping Inside the room shall be properly supported with MS angle, including cutting chases, holes in walls/slabs and making them good after installation. b) 9.5 mm dia (OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
Supply Installation, testing and commissioning of Interconnecting refrigerant copper pipe work (between indoor and outdoor units as per specifications) with (19mm/13mm thick) dosed cell elastomeric nitrile rubber tubular insulation. All piping Inside the room shall be properly supported with MS angle, including cutting chases, holes in walls/slabs and making them good after installation. c) 12.7 mm dia (OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
Supply Installation, testing and commissioning of Interconnecting refrigerant copper pipe work (between indoor and outdoor units as per specifications) with (19mm/13mm thick) dosed cell elastomeric nitrile rubber tubular insulation. All piping Inside the room shall be properly supported with MS angle, including cutting chases, holes in walls/slabs and making them good after installation. d) 15.86 mm dia (OD)(Softdrawn)with tube thickness 1.2mm with 19mm thick insulation
Supply, Installation, Testing and Commissioning of PVC drain piping. 6 Kg pressure rating complete with fittings, supports as per specifications and insulated with 6 mm Nitrile rubber insulation as per specifications and drawings etc complete as required. 25mm dia
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 X 2.5 sqmm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 5 X 2.5 sqmm
Supplying and fixing 5 A to 32 A rating. 240/415 V, 10 kA. "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections,testing and commissioning etc. as required. Double Pole
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface /recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm dia
DIPANKAR BORA
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .