Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.0 LAccepted-Finance | L1 | Accepted-Finance Accepted | |
| 2 | L2₹12.1 L+₹1.1 L (9.86%)Rejected-Finance 2 A NARENDRA APPARTMENT CENTRAL JAIL ROAD SUBHASH BRIDGE AHMEDABAD 380027 | AHMEDABAD | AHMEDABAD | GUJARAT | 380027 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹13.5 L+₹2.6 L (23.3%)Rejected-Finance | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | L4₹14.3 L+₹3.3 L (30.0%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L4 | Rejected-Finance Rejected due to bidder not L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
30 Apr 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (Army) Ahmedabad
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
REPAIR/MAINT OF SUMMER/COOLING APPLIANCES UNDER GE (A) AHMEDABAD CANTT
2025_MES_703507_1
8258/E8
Open Tender
Civil Works
Item Rate
180 days
GE (Army) Ahmedabad
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹30,000
Yes
5 May 2025
4 Apr 2025
3 May 2025
4 Apr 2025
30 Apr 2025
18 Apr 2025
4 Apr 2025 - 18 Apr 2025
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : MAINT GRANT 2024-2025 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
M & L for repair/maintenece and servicing of Split type Air conditioner/Window type unit of any capacity outer and inner unit both of any make including cleaning the dust from body with blower, cleaning of condenser and cooling coil, checking all connections including functioning of metal clad socket/DP switch, function of relay, capacitors, overload protector, thermostat, fan motor, fan/blower drum, main control board PCB, electronic contol box, etc, oiling/greasing of fan motor, checking serviceability, cleaning of the air filter woolen felt & refixing ensuring for air tighting complete, repair and replacement of warn out/unserviceable spares including taking down and refixing, transportation to and from workshop if required and refixing it in its original place or at new loaction after fully servicing including testing & commissioning complete all as specified and directed by Engineer-in-Charge. (Note: Spares parts replaced shall be measured & paid under saperate item)
All as per Item No 1.01 above but for Water cooler/Deep freezer/Refrigerator of any type and any capacity complete all as specified and directed
Supply only starting capacitor 80-100mfd for AC, water cooler, Refrigerator, deep freezer etc all as specified and directed.
Supply only running capacitor 10MFD
Supply only running capacitor 25MFD
Supply only running capacitor 36MFD
Supply Only running capacitor 50MFD
Supply Only running capacitor 60MFD
Supply only blower motor capacitor 4MFD
Supply only blower motor capacitor 6MFD
Supply only blower motor capacitor 10MFD
Supply only starting relay suitable for water cooler, AC, and refigerator, deep freezer for any make and model opreated on single phase 230 volts all as specified and directed.
Supply Only for over load relay comprising of over load protection suitable for air contioner, water cooler, deep freezer and refrigerator opreated in shingle phase 230 volt all as specified and directed.
Supply Only themostat switch suitable for Air conditioner, water cooler, deep freezer and refigerator operated on single phase 230 volts supply all as specified and directed.
Supply only drier filter for AC ,water cooler and refrigerator.
Supply only air filter suitable for window AC/Indoor unit of Split AC upto 2TR capacity as per existing type and size
Supply only magnetic contactor as in outer unit of Split type air conditioner as per existing type complete all as specified and directed.
Supply Only capillary tubes for the following :-
Air Conditioner 1.5 ton /2 ton and Water cooler 40to 150 ltr
Refrigerator & Deep freezer upto 400 ltr
Supply only indoor fan motor of split type AC of any capacity
Supply Only condenser fan motor 1300rpm, 1/6Hp, 1/8Hp, 1/10Hp for Split type Air Conditioner outdoor unit of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only condenser fan motor double shaft 1/6Hp, 1/8Hp, 1/10Hp for Window type AC of 1.0Ton/1.5Ton/2.0Ton as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only condenser fan motor 1/36Hp for Water Cooler of 40-80Ltr and deep freezer upto 400Ltr as per existing make and capacity all as specified and direted by Engineer In Charge
Supply Only condenser fan motor 1/6Hp, 1/8Hp, 1/10Hp for Water Cooler of 120-150Ltr as per existing make and capacity all as specified and direted by Engineer In Charge
Supply only blower/condenser fan blades as per existing make & type for Air conditioner/Water cooler/deep freezer all as specified
S & F Copper tubing including brazing, flaring & testing of size 1/2" and 5/8" in required length with nitrile rubber insulation for suction and discharge line of split air conditioner complete all as specified and as directed
Supply and installed Nitrile rubber insulation in replacement for existing damaged/warn out/unserviceable insulation for air conditioner piping.
Supply, install, test & commissioning thermetically sealed New compressor for Split Type AC of capacity 1.5TR duly charged with fresh freon gas etc complete all as specified/directed by Engineer-in-Charge including taking down old u/s compressor. Make- Voltas/Shriram/LG/Godrej/Kirloskar/Carrier/Hitachi or as per existing make at site.
All as per Item No 1.29 but for Split Type AC of capacity 2.0 TR
All as per Item No 1.29 but forWindow Type AC of capacity 1.5TR
All as per Item No 1.29 but for Water Cooler of capacity 40 to 80Ltr
All as per Item No 1.29 but for Water Cooler of capacity 120 to 150Ltr
All as per Item No 1.29 but for Refrigerator 165 to 210Ltr Capacity
All as per Item No 1.29 but for Refrigerator 286 to 310Ltr Capacity
All as per Item No 1.29 but for Deep freezer up 298 to 310 ltr capacity
M & L for taking down old u/s condenser coil (Heat exchanger) and S&F new copper condenser coil as per existing make and model for Split AC 1.5TR with necessary welding/brazing, leak testing & gas filling all as directed and as specified by Engineer In Charge
All as per Item No 1.37 but for Split Type AC of capacity 2.0 TR
All as per Item No 1.37 but forWindow Type AC of capacity 1.5TR
All as per Item No 1.37 but for Water Cooler of capacity 40 to 80Ltr
All as per Item No 1.37 but for Water Cooler of capacity 120 to 150Ltr
All as per Item No 1.37 but for Refrigerator 165 to 210Ltr Capacity
All as per Item No 1.37 but for Refrigerator 286 to 310Ltr Capacity
All as per Item No 1.37 but for Deep freezer up 298 to 310 ltr capacity
M & L for Detecting the gas leakage, rectifying the defects including repair to condenser coil/evaporator coil by means of welding, soldring etc, vacumizing and charging, topping up fresh freon Gas and commissioning and testing for the 1.5Ton/2.0ton split type/window type AC all as specified and directed by Engineer In Charge
All as per item No 1.45 herein above but of water cooler, refrigerator & deep freezer of any type and any capacity
Supply and replace remote control unit of Split type AC 1.5 ton/2.Ton including making frequency arrangement of new remote with existing system all as specified and directed by Engineer In Charge
Supply only Electronic PCB unit for main control panel of Split type/Window Type AC of any capacity
Supply Only PVC flexible pipe 25 mm dia as in drain pipe suitable for water cooler outlet
M&L for dismantling of existing unserviceable voltage stabilizer for repairs including replacement of relays , electronic voltage sensor circuits and meter, micro switch , indication light RC fitters and other connected items for making funcional as per the entire satisfaction of Engr-in-charge and rewinding of unserviceable transformer with super enameled copper wire of appropriate size , varnishing assembling and testing complete for following capacities:-
Upto 1 & 2 KVA
Upto 3 to 5 KVA
Disconnecting electrical / mechanically and lowering to the ground for repairng / over hauling the desert cooler including replacement of canvas grass / wood wool pads and spary painting to body with one coats of anti corrisive red oxide primer for any make of desert cooler to make it fully funcitonal including replacement of unservicable/defective spare parts, transportation to and from, re-installation and testing on completion to the entire satisfaction of Enineer -in - charge Note : 1. Replacement of canvas grass / wood wool pads/pvc flexible water pipe including PVC T/Y/L branch connections and spary painting is included in quoted rates 2. Other Spares replaced will be measured and paid under saperate Item here in after
Supply only water lifting pump 1/70 HP capacity , operated on single phase 230 volts with all accessories and testing complete to the entire satisfaction of Engr -in-charge.
Supply only fan motor of desert cooler of any capacity including supporting legs , brackets, nuts and bolts etc.
Supply only fan blade with bush for desert cooler motor
Supply only electronic control circuit board (PCB) as per existing type for desert cooler.
Supply only swing motor for air cooler
M & L for fabrication of base tray/top cover suitable for desert cooler upto capacity 5000Cum/Hr to match with existing size of tray/body of desert cooler with 1mm Galvansised steel Sheet with necessary cutting, bending, welding and powder coated paint over one coat of red oxide all as specified and as directed
M & L for repair/replacement to stainless steel waste water tray including welding, polishing, riveting, provision of fixing screws and refixing.
M & L for replacement damage cooling coil for refrigerator of capacity 210/300 ltrs
Supply Only door switch for refrigerator of any type and any capacity
Supply only pigmy lamp (indoor lamp) as per existing type for refrigerator
Supply only freezer door as per existing make and typr for refrigerator
Supply only timer switch assembly for refrigerator as per existing for capacity 210 to 300Ltrs
S & F Metal Plug Tops for 2Pin and earth socket AC Box of capacity 240V, 20A all as specified and directed
S & F Plug Top, SP, 240V, 3pin, 6A
S & F Plug Top, SP 240V, 3pin, 15A
S & F PVC insulated flexible copper cables 2.5sqmm 3 core for electric supply
S & F uPVC MAXI trunking profile of size 150x50mm fixing on wall for covering AC piping, cable, drain pipe etc all as specified and directed
S & F Sheet metal enclosure for Single pole and neutral with two pin and earth plug and socket complete with one single pole MCB 20Amps.
S & F Switch socket combination 2 in 1, 3 pin, 6 and 16 Amp flush type universal
Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule for 15mm bore dia.
S & F in repair Push tap Self closing taps of size 15mm of cast iron or malleable cast iron, galvanised, screwed for iron pipe or for water cooler
Supply and fix PVC connecting pipe with brass nuts and washers at both ends of length not exceeding 60 Cms for connection of water coolers with taking down old pipe
M & L for Framed work such as grills, gratings, etc. for water tanks, water cooler stand, AC Unit supports, and similar work conforming to Fe.290.Gde-E-165 with two coat of synthetic enamaled paint over coat of red oxide primer all as directed and specified by Engineer In Charge
M & L Cutting openings, through brick walls for door, window and other openings or enlarging existing openings built in cement morter etc. for installation of window AC and Forming jambs, etc. in cement morter 1:4, to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete making good to disturbed surfaces all as specified and as directed
Supplying and laying of CPVC pipes of SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified of following Sizes:
Outer dia 16mm
Outer dia 20mm
S & F Rigid non-metallic PVC conduit 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for drain out AC condensate water
M & L for Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FR is PVC insulated copper conductor, single core cable in surface/recessed in Non metalic rigid PVC conduit as required
2x2.5 sq. mm + 1x2.5 sq. mm earth wire
2x4.0 sq. mm + 1x4.0 sq. mm earth wire
Shree Krushna Supply Corporation (BID ID -3284586)
SATISH ELECTRICALS (BID ID -3288944)
JYOT ENTERPRIES (BID ID -3290046)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .