Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.1 LAccepted-AOC 0 BEECHPARA DANGAURA MAHENDRAGARH MANENDRAGARH CHIRMIRI BHARATPUR CHHATTISGARH 497442 | KOREA | CHHATTISGARH | 497442 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹14.1 L+₹97,210 (7.40%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance Rejected being L2 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 May 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (A) Central Jodhpur
GE (A) Central Multan Line Army Area Jodhpur
DAY TO DAY MAINT COMPLAINTS PERTAINING TO EM WORKS UNDER GE ARMY CENTRAL JODHPUR (8938/E8)
2020_MES_341609_1
GE/J/A- of 2020-2021 (8938/E8)
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (A) Central Multan Line Army Area Jodhpur
1.Scanned copy of Application and DD Banker Cheque as cost of tender and copy of EMD for unenlisted contractor 2.Copy of GST Registration Number 3.Copy of enlistment letter 4.For unenlisted contractor details of documents meeting enlistment criteria
5 documents required · 5 mandatory
₹500
GE (A) Central Jodhpur
₹30,000
Yes
21 Dec 2020
29 Apr 2020
29 May 2020
29 Apr 2020
27 May 2020
13 May 2020
60 days
Amount
SCHEDULE 'A' PART-I Attending daily complaints of Jodhpur Mil area by deputing adequate number of teams of qualified Electrician and helper (round the colck) for repair, maintenance and making the continuity of supply after rectifying the defects of the electrical system by replacing the U/S items such as switches, sockets, distribution boards, MCB light/power , lamp holders-bracket/ pendent/ batten, bell/ buzzer , push button, ceiling rose, capacitors and other similar, light & power plug, including provisioning of small pieces of electrical cables PVC insulated copper multistranded conductor of sizes 1.5 Sqmm to 6 Sqmm single core and length not increasing 0.50 mtrs complete all as specified and directed by Engr-in-Charge. (Complaint slip shall be part of the bill). Note:- (i) Contractor shall be fully responsible for Complaint slip/ Job card prepared and submitted on daily basis. (ii) This item pertains to attending complaints of light/fan/power point, MCB DB including other minor items such as insulating tape, screws etc as required to attend the complaint to the entire satisfaction of user/Engr-in-Charge. (iii) Items shall be measured and paid seperately under respective item of Sch 'A'.part II.
M&L to attend major/ minor fault/ No Light due to any reason like neutreal fail or short cicuit complete including petroling or rectfication of complaint etc.
SCHEDULE 'A' PART-II Supply and fixing electronic adapoter for LED light up to 30 watt as per sample Make CG or equivalent in : Havells/Bajaj/Philips.
Supply and fixing repair switch piano flush type 6 amp single pole one way 230 V all as specified & directed Make : Havell's/ Anchor /Legrand
Supply and fixing repair switch piano flush type 6 amp single pole two way 230 V all as specified & directed Make : Havell's/ Anchor /Legrand
Supply and fixing repair switch piano flush type 16 amp single pole one way 230 V all as specified & directed Make : Havell's/ Anchor /Legrand
Supply and fixing repair bell push AC, 230 Volts, Make : Havell's/ Anchor /Legrand
Supply and fixing repair socket out let flush type 6 amp 3/5 pin suitable for 6 Amp plug top 230 V all as specified & directed. Make : Havell's/ Anchor /Legrand
Supply and fixing repair socket out let flush type 3/6 pin suitable for 16 Amp plug top multipurpose 230 V all as specified & directed. Make : Havell's/ Anchor /Legrand
Supply and fixing repair bell AC 230 volts. Make Havell's/ Anchor /Legrand
Supply and fixing repair fan regulator electronic switch type complete all as specified and directed.Make Havell's/ Anchor /Legrand
Supply and fixing repair fan regulator electronic socket type complete all as specified and directed.Make Havell's/ Anchor /Legrand
Supply and fixing repair lamp holder insulated body with back plate batten/angle type for batten fittings complete all as specified and directed.Make Havell's/ Anchor /Legrand
Supply and fix fan capacitor 2.5 m.f.d for ceiling Fan, all as specified and directed.Havell's/ Anchor /Bajaj
Supply and fix fan capacitor 4 m.f.d for Exhaust Fan, all as specified and directed.Make Havell's/ Anchor /Bajaj
Supply and fixing ceiling rose 3 terminals complete all as specified and directed.Havell's/ Anchor /Legrand
Supply and fixing repair Modular switch any type and make 6 amp one way 230 V all as specified & directed . Make:Legrand /ABB/Anchor.
Supply and fixing repair Modular switch any type and make 16 amp one way 230 V all as specified & directed . Legrand /ABB/Anchor.
Supply and fixing repair Modular socket Any Type and make, 6 amp 5 Pin one way 230 V all as specified & directed . Legrand/ABB/Anchor.
Supply and fixing repair Modular socket Any Type and make, 16 amp 5 Pin one way 230 V all as specified & directed . Legrand/ABB/Anchor.
Supply and fixing repair Modular fan Regulator step type and make, 100 watt , 230 Volts all as specified & directed . Make : Legrand/ABB/Anchor.
Supply and fixing repair one Prewired distribution bard in sheet metal encl when MCB TPN Box 4 way to be used with 200 Amps rated copper bus bar confirming to relevant ISI, Cat No :- 607717 , Make : Legrand. Note : Rates are deemed to be included for flushing in wall concealed complete, making good and matching existing surface.
Supply and fixing repair MCCB 4 Pole 125 amps 3 pole Make : Legrand/ABB
Supply and fixing repair MCB SP C Curve 5-32 Amps Make : Legrand/ABB/Havells
Supply and fixing repair MCB TPN 40 to 63 A Make : Legrand/ABB/Havells
Supply and fixing repair MCB SPN C Curve 63 Amps Make : Legrand/ABB/Havells
Supply and fixing repair PVC DB Box 2 way when MCB used.
Supply and fixing in repair LED tube rod 1x 18W/ 1x20W/ 1X22W complete all as specified and directed by Engr-in-Charge.Make : Philips/Bajaj/Havells
Supply and fixing repair poly carbonate transparent energy meter protection cover temper proof suitable for single phase energy meter etc complete.
Supply and fixing repair prewired distribution board in sheet metal encl, prewired when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 4 way Note :- Rates are deemed to be included for flushing in wall concealed complete, making good and matching existing surface. Make : Legrand. , cat No - SD 3706
Supply and fixing repair prewired distribution board in sheet metal encl, prewired when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 8 way , . Note :- Rates are deemed to be included for flushing in wall concealed complete, making good and matching existing surface.Make : Legrand cat No - SD 3707
Supply and fixing repair prewired distribution board in sheet metal encl, prewired when MCB to be used with 200 Amps rated copper bus bar confirming to relevant IS SPN 12 way Note :- Rates are deemed to be included for flushing in wall concealed complete, making good and matching existing surface. Make : Legrand. cat No - SD 3708
Supply and fixing repair sheet metal enclosure with plug socket single pole and neutral enclosure with two pin and earth plug complete with one MCB 20AMPS SP complete all as specified and directed.
Supply and fixing repair MCCB 100 amp TP, 415 volts 16/ 25 KA rupturing capacity including proper thimbles, fixing on DB'S complete all as specified and directed.
Supply and fixing repair PVC conduit 20mm ISI (MMS)grade,all as specified and directed. Make : Polycab/Plaza/Kalinga
Supply and fixing repair PVC conduit 25mm ISI (MMS) grade all as specified and directed.Make : Polycab/Plaza/Kalinga
Supply and fixing repair PVC cassing Capping 25mm ISI (MMS)all as specified and directed. Make : Polycab/Plaza/Kalinga
Supply and fixing PVC Cassing Capping 32 mm ISI (MMS) all as specified and directed. MakePolycab/Plaza/Kalinga
Supply and fixing repair cable flexible , PVC insulated, twin core with copper conductor of size 23/0.0076mm.MakePolycab/Plaza/Kalinga
Supply and fixing repair PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 1.5 sqmm as in replacement of any defective/burnt circuit.MakePolycab/Plaza/Kalinga
Supply and fixing repair PVC insulated and unsheathed FRLS single core multistranded copper conductor for repair, in existing conduit of size 2.5 sqmm as in replacement of any defective/burnt circuit.MakePolycab/Plaza/Kalinga
Supply and fixing repair modular cover plate with frame 4 module type for fixing of modular switch socket, regulators, blank plates etc complete all as specified and directed.
Supply and fixing repair modular cover plate with frame 8 module type including cutting of walls pcc work etc complete all as specified and directed.
Supply and fixing repair modular cover plate with frame 12 module type including cutting of walls pcc work etc complete all as specified and directed.
Supply and fixing repair one bakelite sheet not less then 3mm thick after removing all connection including cutting/chassing to accommedate existing fitment and making connection including cadmium plated screws with cup washer of 275 x 225 MM.
All as per item No 45 above but 225 x 200mm
All as per item No 45 above but 175 x 125 mm
All as per item No 45 above but100 x 100 mm
Supply only GLS Coloured Lamp Red,Green,Milky,0-60 Watt Make Philps/CG/Havell/OSRAM/WIPRO
Fixing only LED batten fitting 16 to 22 watt any type branded make such as Havells/Surya/Phillips/Bajaj etc including 01 Nos tube rod completed with all accessories. (Item will be issued under sch 'B')
Note for all above items:All items are fo r"Materials and labour /Supply and fix" and to be executed in "Repairs" incl taking down old materials only unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are requested to quote their rates accordingly. If in case a complaint is not resolved within the specified time period the contractor shall be liable for a penalty as under. (I) Rs 350.00 Per Complaint, per day, after the specified period. In case of any dispute regarding the penalty the decision of the Accepting Officer shall be final conclusive & binding.
Shri Electrical Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .