Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.9 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹69.4 L+₹2.0 L (2.98%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹76.3 L+₹8.9 L (13.2%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹76.3 L+₹8.9 L (13.3%)Rejected-Finance OPP INCOME TAX OFFICE PAOTA C ROAD JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L4 | Rejected-Finance NOT LOWEST |
Tender Value
₹85.5 L
EMD Value
₹1.5 L
Closing Date
17 Jul 2023, 6:00 pmClosed
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR 342010
SPECIAL REPAIRS TO BLDG NO P-160 AND P-160A IN ARMY AREA JODHPUR UNDER GE (A) NO 1
2023_MES_602562_1
82324/21/E8
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (ARMY) NO. 01
₹1.5 L
Yes
4 Sept 2023
10 Jun 2023
24 Jul 2023
10 Jun 2023
17 Jul 2023
3 Jul 2023
12 Jun 2023 - 1 Jul 2023
Amount
Demolition of Cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness and removing debries and rubbish from site outside the MoD land complete all as specified & directed by Engineer-in-charge.
M&L for laying 40-50 mm thick Machine cut sand stone slabs laid over and including 20 mm thick cement sand screed in CM1:4 over and including 50 mm thick PCC 1:4:8 Type D2 using 40mm graded stone aggregate including filling the joints of sand stone slabs with neat cement mixed with pigment to match the shade of slabs as in plinth protections complete all as specified & directed by Engineer-in-charge.
Dismantling of asbestos cement (corrugated, semicorrugated, etc) sheets in roof covering complete all as specified & directed by Engineer-in-charge.
Dismantling mild steel work of any description not otherwise provided for complete all as specified & directed by Engineer-in-charge.
M&L for running welding in repairs exceeding 2.5cm nut not exceeding 5 cm in length joining metal of thickness exceeding 6mm nut not exceeding 9mm complete all as specified & directed by Engineer-in-charge.
M&L for Mild Steel trussed purlins, rafters, rails and fastenings (Beam, tee, angle, channel of flat sections) including distance pieces cleats etc., complete all as specified & directed by Engineer-in-charge.
M&L for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa fixed with self tapping screws as in roof covering/cladding to wall complete all as specified & directed by Engineer-in-charge.
M&L for Plain, galvanised, mild steel sheeting 0.63mm thick with grade of zinc coating 275 as in hips, valley gutters, drip and straight flashes (length and girth as fixed) complete all as specified & directed by Engineer-in-charge.
Dismantling of wall and ceiling board (fibre, pulp, insulation, etc.) or insulation board/slabs /blankets of any thickness including cover fillets complete all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium snap grid frame work of pre powder coated pre fabricated GI section (Including hangers) for false ceiling of size 600x600mm with ceiling board of PVC laminated gypsum board 10-12 mm thick and fixed as per manufacturer instruction as per sample approved by GE, complete all as specified & directed by Engineer-in-charge.
Demolition of reinforced cement concrete as in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work including reinforcement cut as required to facilitate demolition and removing rubbish material outside the MoD land complete all as specified & directed by Engineer-in-charge.
M&L for RCC M-25 grade Design Mix as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, and in shelves and the like complete all as specified & directed by Engineer-in-charge.
M&L for RCC M-25 grade Design Mix as in beam, roof beam, cantilevers, lintel beam, etc. complete all as specified & directed by Engineer-in-charge.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-charge.
M&L for Mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed by Engineer-in-charge.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for achieving fair finished flat surfaces complete all as specified and directed.
Formwork to edges of rough finished surfaces of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs not exceeding 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exceeding 10cm but not exceeding 20cm wide complete all as specified & directed by Engineer-in-charge.
Exposing existing RCC members such as columns, slabs, lintels, beams, etc., upto the main reinforcement carefully by means of chisel and hammer, wire brushes or by any other mechanical means so as to remove all deteroit concrete and cleaning the surface to remove all loose dust particles, etc., and make the surface ready to receive chemical treatment in specified condition complete all as specified & directed by Engineer-in-charge.
M&L for 30 mm thick guniting in patches on to the required area on RCC/PCC columns, beams, stairs, lintels, retaining walls, sunshades, roofing slabs etc., of all sizes and shapes at all heights from the existing ground floors and all locations with CM 1:2 under pressure of 2 to 2.8 Kg/cm2 after removing the damaged loose spelled concrete by chipping, removal of dust and applying one coat of rust converter kp-100 equivalent grade over existing exposed old reinforcement wherever necessary providing and tying in position 25x25mm. 12mm gauge dia wire MS welded mesh or smaller size over treated surface ready to receive grouts including 5mm to 10mm thick plastering in CM 1:4 to match existing surfaces and finished even and smooth including curing for 10 days etc., complete all operations all as specified and directed including labour charges hire for all tools plants and machineries cost of consumable scaffolding, all types of protective equipment's, pipelines and vessels, materials etc., required to do guninting at the site, removing the debries out of the MoD land in low lying areas and levelling as directed, with two coats of white wash over one coat of primer complete all as specified & directed by Engineer-in-charge.
Note:- (a) After placing the additional reinforcement all concrete surfaces should be thoroughly scrubbed with brushes, washed with water and allowed to dry. To this surface apply chemical polycrete admixture at the rate not less than 2% by weight of cement or as per manufacturer instructions. (b) When polymix coating is in tackey condition guniting to be done with polycrete admixture t the rate not less than 2% by weight of cement or as per manufacturer instructions. Polycrete admixture to be procured from Chemical Adhesive Pvt Ltd Co or their authorized dealer. (c) Cost of the above aspects shall be deemed to be included in the quoted rate of the respective item and nothing extra shall be paid on any account.
All as per item No 19 hereinbefore but for 50mm thick guniting.
M&L for GI wire netting 0.90mm dia and 12mm mesh lathing to wood or metal studding, joists, etc., fixed in walls, ceilings, stanchions, beams, etc. including all laps, cutting and waste complete all as specified & directed by Engineer-in-charge.
Demolition of stone slabs and tiles of any description or thickness in floors aprons etc laid bedded and pointed in any mortar complete all as specified & directed by Engineer-in-charge.
M&L for 75mm thick cement concrete 1:4:8 type D2, using 40 mm graded stone aggregate including well compacting & laid to levels as in sub base to floors complete all as specified & directed by Engineer-in-charge.
M&L for Chequered cement concrete tiles, rubber moulded 300mm x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry with grey cement with pigment over and including 20mm thick screed bed in CM 1:4 as in floors complete all as specified & directed by Engineer-in-charge.
M&L for providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying if inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified & directed by Engineer-in-charge.
M&L for providing and laying at or near ground level, factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement : 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified & directed by Engineer-in-charge.
Taking down carefully cement concrete/ spelled out concrete from RCC roof projections, Ceilings, Sunshades, beams etc., upto cover depth by chipping out lightly including necessary scaffolding etc., complete all as specified & directed by Engineer-in-charge.
M&L for cleaning the existing reinforcement of slabs chajjas etc., and applying a coat of SIKA RUSTOFF 11 or equivalent in Make Pidilite, Fosroc, Thermax etc., to remove rust particles etc., thoroughly cleaning the surface complete all as specified & directed by Engineer-in-charge.
M&L for applying a coat of bond coat made with cement slurry (1part cement to 1.5-2parts water) mixed with admixture LATEX POWER mixed @ 5 Kg per 50kg of cement & applying to the concrete surfaces @ 200gm/sqm to obtain a tack coat complete all as specified & directed by Engineer-in-charge.
M&L for 15-20mm thick, rendering in CM 1:1:2 using 1 part of cement, 1part of 2-3mm screenings of stone aggregate & 2 parts of coarse sand over the bond coat applied surfaces with cement mixed SIKA PLASTOCRETE admixture or equivalent in Make Pidilite, Fosroc, Thermax etc., @ 100gm/50kg of cement & finishing the surfaces even & rough to receive final rendering coat complete all as specified & directed by Engineer-in-charge.
M&L for 10-15mm thick rendering in CM 1:3 over the bond coat applied surfaces with cement mixed SIKA PLASTOCRETE SUPER admixture @100gm/50kg of cement & finishing the surfaces even & smooth complete all as specified & directed by Engineer-in-charge.
S&F GI chicken wire mesh of 0.71mm dia wire & 12mm mesh size fixed with nails & screws around RCC chajjas/fascias etc complete all as specified & directed by Engineer-in-charge.
Taking down existing cement plaster including racking out joints, hacking for key, scrubbing down with water etc complete all as specified & directed by Engineer-in-charge.
M&L for 15mm thick rendering in CM 1:6 finished even and smooth without extra cement on stone wall surface complete all as specified & directed by Engineer-in-charge.
M&L for rendering 15 mm thick in two layers of 10mm thick on stone masonry surface in CM 1:6 and top layer of 5 mm thick in CM1:4 including finishing the surface fair and even without using extra cement and using integral water proofing compound in top layer complete all as specified & directed by Engineer-in-charge.
M&L for rendering 10 mm thick in CM 1:3 on concrete surfaces finished even & smooth on ceiling / facia /RCC Chhaja etc., complete all as specified & directed by Engineer-in-charge.
Racking out joints/pointing to square rubble masonry Jodhpur type regular coursed built in cement mortar complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing in CM 1:3 to square rubble masonry Jodhpur type regular course complete all as specified & directed by Engineer-in-charge.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified & directed by Engineer-in-charge.
M&L for squared rubble walling Jodhpur type regular coursed well bonded, bedded and solidly hearted built in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
All as per item No 40 hereinbefore but except stone complete all as specified and directed complete all as specified & directed by Engineer-in-charge.
Extra over squared rubble stone walling Jodhpur type regular course for hammer dressing to face of stone with max depression on face from a straight edge not exceeding 20mm and dressing complete all as specified & directed by Engineer-in-charge.
M&L PCC solid building blocks 10 cm thick, with CC 1:2:4 type B1, 1:2:4 set in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
M&L for Plain cement concrete 1:2:4, type B1, using 20mm graded stone aggregate as in coping to parapet walls including necessary form work complete all as specified & directed by Engineer-in-charge.
M&L for Plain cement concrete 1:2:4, type B0, using 12.5mm graded stone aggregate as in roof kerbs rounded or chamfered on edges complete all as specified & directed by Engineer-in-charge.
M&L for cutting into old masonry to form toothings for bonding in new brick or stone work including making good in cement mortar 1:6 complete all as specified & directed by Engineer-in-charge.
M&L 50mm thick sand stone slabs in sunshades, chajjas, shelves, cills, landings cover stones, templates etc., not exceeding 2m in length punched dressed on face and along exposed edges self faced on other side and set and pointed in cement mortar 1:4 complete all as specified & directed by Engineer-in-charge.
Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified & directed by Engineer-in-charge.
M&L for 25 mm thick PCC 1:2:4, type B0 using 12.5mm graded stone aggregate as in sub bases floors complete all as specified & directed by Engineer-in-charge.
M&L for non-skid coloured ceramic tiles joint less, 7 to 8 mm thick area of each tiles exceeding 0.18 Sqm but not exceeding 0.38 sqm set jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15 mm thick screed bed in cement mortar 1:6 as in floors etc complete all as specified & directed by Engineer-in-charge.
All as per item above but skirting including 10 mm thick rendering in CM 1:3 complete all as specified & directed by Engineer-in-charge.
M&L non skid ceramic colour joint free tiles, 6 to 7 mm thick of size area exceeding 0.11Sqm but not exceeding 0.18 Sqm set jointed in neat cement slurry and pointed in white or coloured cement to match the shade including 15 mm thick screed bed in cement mortar 1:6 as in floors etc., complete all as specified & directed by Engineer-in-charge.
M&L for glazed colour ceramic tiles of size 250x350x7mm, set and jointed in neat cement slurry and pointed in coloured tiles to match the shade of tiles laid in vertical surface dado/ skirting joint free etc, complete all as specified & directed by Engineer-in-charge.
M&L for 18-20mm thick machine cut Kota stone slab over screed bed base, laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing over and including 20mm thick screed bed in cement mortar 1:4 as in flooring, cooking platforms/treads of steps from etc., complete all as specified & directed by Engineer-in-charge.
M&L for 16-18mm thick Green marble slab over and including cement screed 15mm thick in cement mortar 1:4 laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing as in cills, platforms treads of steps etc., complete all as specified & directed by Engineer-in-charge. Note: Quoted rate deemed to including the cost of chamfering the exposed edges of marble.
M&L for 16-18 mm thick Green marble slab (table rubbed and polished) fixed in CM 1:4, including pointing in white cement 1:2 using marble dust with admixture of pigment to match with marble shade including 10mm thick plaster 1:3, as in riser of steps, jambs, pillars and like complete all as specified & directed by Engineer-in-charge.
M&L for 18-20 mm thick Black granite stone laid over and including 15 mm thick cement sand screed in CM 1:4 as in cooking platforms, slabs for oval type WHB, sinks/cills etc., & the likes including mirror polishing complete & providing necessary holes for gas pipe complete all as specified & directed by Engineer-in-charge.
Rounding to edges of stone slabs one edge, such as in steps, cooking platforms and other similar situations complete all as specified & directed by Engineer-in-charge.
M&L for treating the surface of existing kota stone floors, surfaces of dado/skirting with bees wax polish including cleaning and preparing the surfaces complete all as specified & directed by Engineer-in-charge.
Complete removal of existing treatment from walls all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered or un plastered ceiling surfaces and applying three coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old ceiling surfaces and applying one coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new plastered/pointed wall surfaces and applying three coats of white wash complete all as specified & directed by Engineer-in-charge.
M&L for preparation of wall surfaces and applying two coats of Oil Bound distemper over 1.5mm to 2mm thick wall putty finished to a even and smooth finish over a coat of alkali primer complete all as specified directed by Engg-in-charge.
M&L for complete removal of existing cement base paint on wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified & directed by Engineer-in-charge.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new wall surfaces complete all as specified & directed by Engineer-in-charge.
M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
M&L for preparation of old steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified & directed by Engineer-in-charge.
M&L for mild steel framed work as in brackets, cooler stands, supporting frame work for sun shade, framed steps/stairs, using MS sections/angle iron steel bars, gusset plate etc., complete all as specified & directed by Engineer-in-charge.
S&F Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed Fe 410-W (Gde- E- 250) quality- A complete all as specified & directed by Engineer-in-charge.
M&L for fabrication of pressed steel cupboard shutters using 1.0mm thick MS plain sheet & with frame 1.25 MM thick bent to shape including two coats of synthetic enamel paint on internal surfaces & two coats of hammer tone finish on external surfaces along with locking arrangement, mortice lock, handle etc., complete all as specified & directed by Engineer-in-charge.
Taking down shutter of any description, exceeding 1Sqm but not exceeding 2 Sqm and refixing in the same opening after necessary repair like easing etc., complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats with shutters (without taking off shutters from the frames) area exceeding 1.5sqm but not exceeding 4Sqm & removal to store complete all as specified & directed by Engineer-in-charge.
Taking down chowkhats with shutters (without taking off shutters from the frames) area not exceeding 1.50 Sqm & removal to store complete all as specified & directed by Engineer-in-charge.
S&F of pressed steel frames of size 165x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified & directed by Engineer-in-charge.
S&F of pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc., complete all as specified & directed by Engineer-in-charge.
M&L for Solid PVC Door Frame of size 50mm x47mm made out of 5mm wood grain printed PVC sheet including all edges printed to match the shade reinforced with M.S. Square tube, supplying & fixing in opening as per specifications & drawing complete all as specified & directed by Engineer-in-charge.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed PVC ‘C’ channel having a wood grain printed PVC sheet strip complete all as specified & directed by Engineer-in-charge.
S&F 40mm thick Flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides with both face covered with decorative face veneer with lipping/frame to match, complete all as specified & directed by Engineer-in-charge.
S&F 35 mm thick 2nd Class hardwood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc.(without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.24 (a) complete all as specified & directed by Engineer-in-charge.
S&F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:2:4, type B0, using 12.5 mm graded stone aggregate as in filling pressed steel frame (concrete shall be compressed) complete all as specified & directed by Engineer-in-charge.
Taking down of steel window and ventilators of any size and type complete all as specified & directed by Engineer-in-charge.
S&F of factory made steel window box type with side hung shutter as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 complete with glazing bars, dovetailed or welded complete all as specified & directed by Engineer-in-charge. Note:- Both shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer in charge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required)Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'.
S&F of factory made steel window box type with side hung shutter as shown on drawing No CEJZ/TD/20 sheet 1/3 to 3/3 complete without glazing bars, dovetailed or welded complete all as specified & directed by Engineer-in-charge. Note:- Both shutter jointed internally with flat iron 40x4mm complete including grill of 8/10mm square bars as directed by Engineer in charge, fixed horizontally @ 10cm c/c, hinges, handle, tower bolts, stops, lugs etc. (with provision of fixing for cooler if required)Guard bar/ grill shall be measured and paid separately under respective item of Sch 'A'.
S&F Factory made box type steel ventilator with glazing bars dovetailed or welded and with one shop coat of zinc chromate primer complete all as specified & directed by Engineer-in-charge.
S&F 4 mm thick pin headed figured glass in small widths as in louvers of ventilators complete all as specified & directed by Engineer-in-charge.
M&L for 3mm thick, plain sheet glass ordinary quality in squares not exceeding 0.50 Sqm and glazing with oil putty or with wooden beads (supplied along with shutters) complete all as specified & directed by Engineer-in-charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified & directed by Engineer-in-charge.
M&L for Mild steel round bars welded to steel windows or ventilators as in guard bars framed or unframed complete all as specified & directed by Engineer-in-charge. Note :- Guard bars shall be factory welded & given one shop coat of red oxide or zinc chromate primer. Cost of factory welding & shop coat of primer is deemed to be included in quoted rates.
S&F Anodised aluminium powder coated frame for doors, windows, ventilators and partitions with one or more rebates including joining cleat for fixing etc, complete all as specified & directed by Engineer-in-charge.
S&F Anodised aluminium powder coated door shutters, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, 2tower bolts, 1mortice lock of vertical type brass 4 levers size 65mm and anodised aluminium snap beading screws etc, complete all as specified & directed by Engineer-in-charge.
S&F 4 mm thick sheet glass in square not exceeding 0.5 sqm in each pane, ordinary quality and glazing with oil putty/wooden beads complete all as specified & directed by Engineer-in-charge.
M&L for 10mm thick PVC insulation panel with EPS stuck to 1mm plain PVC sheet suitably placed in aluminium frame work as per specification complete all as specified & directed by Engineer-in-charge.
M&L for repair to Anodised aluminium powder coated doors, window and ventilator frames/ shutters including taking down, replacement of unserviceable hinging device box type, handles, making them in serviceable condition and refixing in same opening including joining cleat for fixing complete all as specified & directed by Engineer-in-charge.
S&F aluminium anodized tower bolt, 200 mm long complete all as specified & directed by Engineer-in-charge.
S&F aluminium anodized tower bolt 150 mm long complete all as specified & directed by Engineer-in-charge.
S&F aluminum anodised handle, extruded section of size 150mm long complete all as specified & directed by Engineer-in-charge.
S&F aluminium alloy anodised sliding door bolt worth hasp and staple (bolt type) and fixings clips of sheet cast or extruded sections and fixings bolts and sliding bolts of extruded sections and fixed 16mm dia and 300mm long complete all as specified & directed by Engineer-in-charge.
S&F stainless steel butt hinges 100 mm size complete all as specified & directed by Engineer-in-charge.
S&F mild steel butt hinges 100 mm size complete all as specified & directed by Engineer-in-charge.
S&F 125 mm size single action door spring hinge complete all as specified & directed by Engineer-in-charge.
S&F Door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed by Engineer-in-charge.
S&F floor door stopper of alluminium alloy body and tongue anodised with hard drawn steel spring 140mm long complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:2:4, type B1, using 20mm graded stone aggregate as in bed blocks for fixing hold fast etc., including necessary form work complete all as specified & directed by Engineer-in-charge.
S&F MS flat iron as in hold fast and similar work confirming to Fe-290 Gde-E-165 fixed to frames with welding and necessary items complete all as specified & directed by Engineer-in-charge.
M&L for providing precast louvers and jallies, cement grill any type model of zafri 25/35 mm thick (measured solid) with cement concrete1:2:4, type B0 using 12.5mm graded stone aggregate and set in CM 1:4, including all mouldings complete all as specified & directed by Engineer-in-charge.
S&F in repairs decorative type curtain rod stainless steel finish made of steel pipe, 22 to 25 mm dia as per sample approved by GE complete all as specified & directed by Engineer-in-charge.
S&F purpose made brackets trade pattern for decorative type curtain rods suitable for holding 22 to 25 mm dia as per sample approved by GE complete all as specified & directed by Engineer-in-charge.
S&F in repair decorative fincals (round type with mirror optic finish) trade pattern for decorative type curtain rods suitable for 22 to 25 mm dia curtain rods as per sample approved by GE's complete all as specified & directed by Engineer-in-charge.
S&F in repair Stainless steel sink of overall size 495mmx420mm with bowl size 410mm x 330mmx160mm, made of 1.00mm thick sheet for kitchen or laboratory with plug, washers waste pipe, cast iron cantilever brackets connecting union complete all as specified & directed by Engineer-in-charge.
Dismantling of 100mm bore Cast iron or AC drain pipe/ PVC pipe jointed in cement mortar complete all as specified & directed by Engineer-in-charge.
Dismantling of 75mm bore Cast iron or AC drain pipe/ PVC pipe jointed in cement mortar complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified & directed by Engineer-in-charge.
S&F 75mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed on walls complete all as specified & directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) bends any radius complete all as specified & directed by Engineer-in-charge.
S&F 100mm bore pipe PVC (SWR) vent cowls, complete all as specified.
S&F 75mm bore pipe PVC (SWR) vent cowls, complete all as specified.
M&L cast iron up to 150mm bore fittings of Bends (any type, radius and angle) tapers any type, (straight, bend, increasing, decreasing or double socket etc.) Tee pieces, single branch, 'Y' junctions, double branch, cross (all sockets or socket and spigot) collars, caps and plugs etc; complete all as specified & directed by Engineer-in-charge.
S&F in repairs Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified & directed by Engineer-in-charge.
S&F in repairs 15 mm bore angular stop cock with chromium plated long thread with flange complete all as specified & directed by Engineer-in-charge.
S&F in repairs 15 mm bore bib taps long body with flange with chromium plated fixed with iron pipe complete all as specified & directed by Engineer-in-charge.
Dismantling existing tanks of any description not exceeding 500 ltrs capacity and removing from site complete all as specified & directed by Engineer-in-charge.
All as in item No 128 hereinbefore but for 1000 ltrs capacity
S&F 500 ltrs capacity Rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position including fixing arrangement for inlet/outlet/overflow & vent pipe of standard size complete all as specified & directed by Engineer-in-charge.
All as in item No 130 hereinbefore but for 1000 ltrs capacity
Supply only 20mm bore Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 210 gms) all as specified & directed. (Fixing included in Item No 130 & 131 hereinbefore)
S&F in repair 25 mm bore stop valves, cast copper alloy, screw down high pressure with crutch or butterfly handle screw both ends for iron pipe or for union & fixed complete all as specified & directed by Engineer-in-charge.
Supply only Integral water proofing compound
Taking down or up steel tubing and connection including cleaning for refixing or credited to contractor for the following bore pipes complete all as specified & directed by Engineer-in-charge.
25 mm dia
20 mm dia
15 mm dia
S&F GI water tubing, medium grade, galvanized, with all fittings fixed to wall or laid in floors for the following bore pipes complete all as specified & directed by Engineer-in-charge.
25 mm dia,
20 mm dia
15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc complete.
Re fixing/ Re laying of old GI water tubing and connections in new or old position including provision of new GI fittings for the following bore pipes complete all as specified & directed by Engineer-in-charge.
25 mm dia,
20 mm dia
15 mm dia including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc complete all as specified & directed by Engineer-in-charge.
M&L for Forming 12mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘A’ complete all as specified & directed by Engineer-in-charge.
Taking down existing damaged /loosed cement concrete /bricks tiles from roof /terrace to a depth of average 50 mm including taking down of existing APP membrane if any cleaning with water and depositing of debris outside MoD land complete all as specified & directed by Engineer-in-charge.
M&L for PCC 1:2:4, type B0, using 12.5 mm graded stone aggregate as in padding over old cleaned surface of any description on roof/terrace to fill any depressions etc., or to obtain desired slopes complete all as specified & directed by Engineer-in-charge.
M&L for roof treatment in the following stages:- (a) First Course: M&L for 10 mm thick plaster with CM 1:3 mixed with water proofing compound as per manufacture instructions (Note:- WPC shall be measured and paid separately) (b) Second Course: One coat of bitumen primer T-10/polymerised confirming to IS:3384 @ 0.30 ltr/Sqm (c) Third Course: One coat of Binding material using blown type bitumen conforming to IS 702 grade 85/25 @ 1.20 Kg/Sqm (d) Fourth Course: A layer of APP membrane polymeric membrane centre core of 100 micron HMHDPE outer film 20 micron each, thickness 3 mm having weigh 3.00Kg/Sqm (e) Fifth Course: A coat of bonding material using blown type bitumen conforming to IS-702 of grade 85/25 @ 1.20 Kg/Sqm (f) Sixth Course: 40mm thick PCC 1:2:4 padding, well compacted using 20 mm graded aggregate with grooves shall not be exceeding 1.40 Sqm
Taking down carefully alluminium / copper point wiring complete for light, fan, socket or power point etc with fittings fixtures such as ceiling rose, holders, electric fittings, switches, sockets, aluminium conductor cable with and including wooden batten or FR PVC conduit and its accessories such as wooden gutties, rawl plugs, GI screws, aluminium clips, nails etc complete and removing the material from site and making good the disturbed surface of wall / floor/ ceiling etc as original i.e. brick work, plastering, white washing, OBD etc as required, complete all as specified and directed.
Taking down carefully unserviceable main switch and DB's including MCBs of any size make, type and capacity and depositing at site as directed.
Taking down carefully unserviceable sub main wiring of any size and all as directed.
M&L for Point wiring for Modular fittings (Concealed) using approved colour coding as per IS Red/Yellow/Blue, Black and green for single phase circuits) with multi stranded copper conductor 1.5 Sqmm nominal cross area single core PVC insulated and unsheathed FR LS cable 1100 Volts grade ISI 694 marked with valid CML No. in and including medium grade PVC concealed conduit of dia not less than 20mm and conduit accessories ISI marked with valid CML No. (IS 9537 -1983) for wall/roof /floor etc with pressed flush metal boxes modular covered with inner plates & outer plates etc suitable for mounting of Modular switches & sockets including PVC insulated multi stranded copper conductor FRLS 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following:-
One light point controlled by one, one way switch
One fan/ Exhaust Fan point controlled by one way switch.
One socket outlet 3 pin, 5 Amps on independent board, controlled by one no 5 Amp switch.
One socket outlet 3 pin 5 amps on the same board controlled by one no 5 Amp switch.
One bell point controlled by one bell push.
All as per item no 145 hereinbefore but One light point controlled by two, two-way switches
All as per item no. 145 here-in-before but with 2.5 sqmm FRLS copper wire with 2.5 Sqmm FRLS copper earth wire for independent 15 Amp point complete all as per directed by Engr-in-Charge
S&F Modular switch flush type single pole one way 6 Amp ISI Marked complete all as per directed by Engr-in-Charge
S&F Modular switch flush type single pole one way 16 Amp ISI Marked complete all as per directed by Engr-in-Charge
S&F Modular bell push, flush type, 6 Amp ISI Marked complete all as per directed by Engr-in-Charge
S&F bell, AC 230 volts, single pole Multi tune type complete all as per directed by Engr-in-Charge
S&F Modular socket outlet 2 in 1, 5 pin, 6 Amp, 230 Volts flush type complete all as per directed by Engr-in-Charge
S&F Modular socket outlet 2 in 1, 6 pin, 5 and 16 amp flush type, 230 Volts ISI Marked complete all as per directed by Engr-in-Charge
S&F modular socketed stepped type electronic fan regulator flush type ISI Marked complete all as per directed by Engr-in-Charge
S&F modular switch 2 way 6 Amp, 1 module, ISI Marked complete all as per directed by Engr-in-Charge
S&F Lamp holder, metal cased, bakelite body, 230 volts, ISI marked complete all as per directed by Engr-in-Charge
S&F LED lamp 9W ISI Marked complete all as per directed by Engr-in-Charge
S&F Ceiling rose, two to three terminals, bakelite body, 230 volts, complete all as per directed by Engr-in-Charge
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including AC decorative box type with driver, holder including, copper conductor cable of suitable size from ceiling rose complete , 4 ft long complete all as per directed by Engr-in-Charge
S&F Building security LED Light Luminaire of 25/15 Watts having IP 65 protection fitting made out of pressure die cast Aluminium housing, operating Voltage 140-270 Volts with in built surge protector, toughened glass with and including GI pipe 40 mm bracket of 1.5 m in length including drilling holes, nuts & bolts 2 coats of red oxide primer on GI pipe and fixing with wall security light on building wall connecting cable complete all as per directed by Engr-in-Charge
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as per directed by Engr-in-Charge
Supply and fix in repair 2'x2' energy efficient recess mounting 36 watt, LED luminaries fixing for POP/snap grid ceiling housing including LED lamps other accessories and necessary electric connection complete all as per directed by Engr-in-Charge
Supply and fixing round shape 6 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as per directed by Engr-in-Charge
S&F Decorative, wall mounting fitting brushed nickel finish fixture with acrylic diffuser suitable with 9 W LED lamp B22 base complete all as per directed by Engr-in-Charge
M&L for taking down old serviceable fan and refixing in same position after painting including connecting from celling rose to fan connector complete all as per directed by Engr-in-Charge
Taking down exhaust fan of any make, type and sweep by disconnecting electric connection and depositing in MES store yard and refixing in same position after applying two coats of painting by connection from ceiling rose to fan connecter all as per direction of Engr-in-Charge.
S&F Vertical Distribution Board, Double Door, suitable for 'A' Frame FP MCCB, 100A made out of CRCA mild steel sheet surface with insulated material like polyester or with epoxy powder coating and IP 43 & IK 09 protection, TPN 4 way, 415 volts with bus bar rating 300 Amps, dust and vermin proof, suitable for incorporation of MCB’s and MCCB etc and making all necessary connections, duly flush of wall surface, complete all as specified and directed. Note : MCCB & MCB will be measured and paid separately under respective items
S&F MCCB, A Frame, thermal adjustable magnetic setting, Ics = 75%, 25 kA, 415V, 100 Amp, 4 Pole MCCB with over load and short circuit protection, complete all as directed.
S&F MCB, B Curve type, 10 kA, 63Amp, SPN with over load and short circuit protection, complete all as directed.
S&F MCB, B Curve type, 10 kA, 6 to 32 Amp, Single Pole with over load and short circuit protection, complete all as directed.
S&F MCB DB, SPN, (double door), 8 Ways including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall including dismantling of old unserviceable DB complete all as specified and directed by the Engr-in-Charge.
S&F Sheet metal enclosures DB's SPN, 12 way, 240 volt with suitable rated bus bar, double door , IP-43, suitable for one MCB SPN as incoming and 6 MCB SP as out going complete all as specified and directed by Engr-in-charge.
S&F Sheet metal enclosures DB's, SPN, 04 way, 240 volt with suitable rated bus bar, double door, IP-43, suitable for one MCB SPN as incoming and 2 MCB SP as out going complete all as specified and directed by Engr-in-charge.
M&L for sub main wiring with 2 run of 6 Sqmm FRLS, PVC insulated, unsheathed and stranded copper conductor cable with and including 6 Sqmm (nominal area) FRLS, PVC insulated, unsheathed and stranded copper conductor cable as earth wire connected with thimble from main DB to sub main DB, drawn in to separate concealed medium grade, ISI marked, non metallic PVC conduit 15 mm dia size including all conduit accessories & fittings / junction boxes / inspection covers etc, with and including cutting chasing and making good of disturbed surface of wall / floor/ ceiling etc as original by brick work, plastering, white washing, OBD etc as required, complete all as directed. Note:- Two run of 6 Sq.mm. and one run of 6 Sq.mm (earth wire) cable including one run of conduit pipe will be measured as one length including making good the disturbed surfaces.
M&L for in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4 mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 mm dia with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
S&F 4 .00 mm dia galvanised iron or steel wire as Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required compete all as directed by Engr-in-charge.
Supply, laying testing LT UG XLPE insulated, armoured, heavy duty electric cable, aluminium conductor, 1100 V grade, cross sectional area 50 sqmm 3.5 core laid in trenches compete all as directed by Engr-in-charge. Note : Earth work and bricks measured and paid separately
Excavation in trenches in soft loose soil, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, laying pipes/elect cables etc, and getting out all as per direction of Engr-in-Charge.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified in soft/loose/hard/dense soil all as per direction of Engr-in-Charge.
Removal of surplus loose soil from excavated place and depositing at safe side at distance not more than 50 meter from excavated place complete all as directed by Engr-in-Charge.
Supply and lay sand for sand cushioning for cable protection in trenches as specified in SSR Part - 1 complete all as directed by Engr-in-Charge. Note:- for the purpose of payment punned thickness will be measured.
Supply and laying unreinforced Precast cement concrete cable cover, flat of size 300mm x 180mm x 40mm complete all as directed by Engr-in-Charge.
S&F 40mm bore, GI tubing, Light grade for cable protection laid in floors, fixed to walls etc complete all as directed by Engr-in-Charge.
S&F Sheet metal enclosure, SPN with a two pin earth plug and socket with metal clad top and one MCB,SP, 20Amps capacity complete all as directed by Engr-in-Charge.
Taking down old serviceable Spilt AC complete (inner and outer) including voltage stabilizer any size and capacity and take in safe custody and refixing in same position complete all as directed by Engr-in-Charge.
M/S KAUTILYA GARG
Jai Doulat Construction Co
Harsh Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .