Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹54.9 L
EMD Value
₹1.1 L
Closing Date
13 Feb 2020, 4:00 pmClosed
Executive Engineer, STD Ganderbal
Office of Executive Engineer, STD Ganderbal
Electrical Works of under Construction 33/11KV, 6.3 MVA Receiving Station Hakbara
2020_PDD_91830_1
STD/GBL/31 of 2019-20
Open Tender
Electrical Works
Turn-key
40 days
Hakbara, Bandipora
Refer SBD and Technical Specification
7 documents required · 7 mandatory
₹2,000
Executive Engineer, STD Ganderbal
₹1.1 L
25 Feb 2020
3 Feb 2020
14 Feb 2020
3 Feb 2020
13 Feb 2020
4 Feb 2020
3 Feb 2020 - 13 Feb 2020
Amount
Electrical works of Receiving Station Hakbara
Supply, Installation, testing and commissioning of 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) (as per specifications) (Make-BHEL/Crompton/Siemens/ABB/schneider/pascal/stelmac)
Supply, Installation, testing and commissioning of 33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port (Make-BHEL/Crompton/Siemens/ABB/schneider/pascal/stelmac)
Supply, Installation, testing and commissioning of 11 kV VCB Panel Board (1+5) (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (Make-BHEL/Crompton/Siemens/ABB/schneider/pascal/stelmac)
Supply,laying, testing and commissioning of 12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS. (Make- Havells/KEI/Polycab/Gloster)
Supply, laying, testing and commissioning of 6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS. (Make- Havells/KEI/Polycab/Gloster)
Supply, laying, testing and commissioning of 4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS. (Make- Havells/KEI/Polycab/Gloster)
Supply, laying, testing and commissioning of 2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI,FRLS. (Make- Havells/KEI/Polycab/Glostar)
Supply and fixing of Lugs, Ferrules etc.
Supplyand laying of Earth wire 7/4 mm sq.
Supply, laying, testing and commissioning of 50 mm² AB (LT) Cable ( 3x50 + 1 x 16 + 1 x 35 mm²) XLPE (1.1kV, 3+1 C, Al) (Make- Havells/KEI/Polycab/Glostar/Paramount)
Supply, Installation, testing and commissioning of Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm.Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar ofadequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
Supply, Installation, testing and commissioning of Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
Supply, laying, testing and commissioning of Earthing Mat (GI Flat 50x8)
Supply, laying, stringing, testing and commissioning of 200 sqmm ACSR Conductor Panther
Supply and fixing of Galvanised Nuts and Bolts
Supply,excavation of pits, erection, Installation, testing and commissioning of 9 Mtr ST pole ST-410 SP33
Providing and Laying of Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Supply, Laying, testing and commissioning of Earthing of 100KVA substation -Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Supply, Laying , testing and commissioning of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI strip
Installation, testing and commissioning of 33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA)
Installation, testing and commissioning of 33 kV Isolator without Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA)
Installation, testing and commissioning of 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less
Installation, testing and commissioning of 33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
Installation, testing and commissioning of 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
Installation, testing and commissioning of 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
Installation, testing and commissioning of T Clamps
Installation, testing and commissioning of Single Tension Fittings
Installation, testing and commissioning of Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN
Installation, testing and commissioning of GI wire soft
Installation, testing and commissioning of 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
Fixing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits-400 sqmm
Fixing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits-400 sqmm
Fixing and commissioning of 11 kV Indoor Heat Shrinkable Cable Termination Kits-185 sqmm
Fixing and commissioning of 11 kV outdoor Heat Shrinkable Cable Termination Kits-185 sqmm
Installation, testing and commissioning of a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
Installation, testing and commissioning of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch.
Installation, testing and commissioning of 11kV GO, AB Switch 3-Phase, 3-Pole, 600 Amp
Laying, testing and commissioning of 11 KV 3- Core 400 mm² armoured, FRLS
Laying, testing and commissioning of 11 kV 3- Core XLPE 185 mm² armoured, FRLS
barclays electrical Engineers
KAPH TECH CONSULTANCY (P) Ltd.
Saad Constructions
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .