Name of work:- Repairing/Renovation and Colour Work at Diff.Muni. Buildings of
Naranpura ward in west zone.
Qty Description of Item Per Amount Rs.
Excavation for foundation up to1.5 m depth including
sorting out and stacking of useful materials and
1a 20.00 disposing of theexcavated stuff upto 50 Meter lead.(A) Cmt
Loose or soft soil
1.5 to 3.0 mt.depth
Excavation for foundation for depth from 3.0 m to 5.0 m
including sorting out and stacking of useful materials and
c 20.00 disposing off Cmt
the excavated stuff upto 50 Meter lead.(A) Loose or soft soil
Excavation for foundation for depth from 1.5 m to 3.0 m
including sorting out and stacking of useful materials and
d 10.00 disposing off the excavated stuff upto 50 Meter lead.(C) Cu.M.
Filling available excavated earth (excluding rock) in
trenches, plinth, sides of foundations etc. in layers not
2 10.00 exceeding 20 cm. in depth consolidation each Cmt
deposited layer by ramming and watering.
Filling in plinth with sand underfloors including
3 10.00 watering ramming, consolidating and dressing etc. complete. Cmt
Filling in foundation and plinth with murrum or selected soil
4 10.00 in layers of 20 cm. thickness including watering, Cmt
ramming and consolidating etc. 286.20
Providing and laying cement concrete1:5:10 (1-
Cement: 5- coarses sand and:10-hand broken stone
5 5.00 aggregates 40mm nominal size) and curing Cmt
complete excluding cost of formworkin (A) Foundation 2,492.51
and Plinth (upto 10 ton).
Providing and laying cement concrete1:4:8 (1-
Cement: 4- coarses and:8-hand broken stone
6 5.00 aggregates 40mm nominal size) and curing complete Cmt
excluding cost of formworkin (A) Foundation and Plinth 2,634.11
Providing and laying cement concrete 1:3:6 (1-Cement : 3-
coarse sand : 6- hand broken stone aggregates
7 5.00 mmnominal size) and curing complete excluding cost of Cmt
formwork in (A) Foundation and Plinth..
Providing and laying cement concrete 1:3:6 (1-
Cement:3-coarse sand:6-hand broken stone
8 5.00 aggregates 20mm nominal size) and curing complete Cmt
including cost of formwork in (A) wall caps/coping 4,006.15
(upto 10 ton)..
Providing and laying cement concrete work 1:2:4 ((1-
Cement:2- coarse sand:4-graded aggregates 20mm
9 nominal size) curing complete excluding cost
of formwork and reinforcement.
Foundations, footings, base or columns and mass
a 5.00 concrete Cmt
Slabs, landing, shelves, balconies, lintels, beams,
b 5.00 girders and cantilivers upto floor two level Cmt
Independent piers, columns, and pillars, upto floor two level
Provdg. & laying cement concrete 1:2:4 (1 cement :
coarse sand : 4 graded stone aggregates 20 mm nominal
size) for reinforced concrete chhajjas not exceeding
10 cm. thickness upto floors two level including
10 5.00 finishing the exposed surfaces with cement mortar Cu.M.
1:3 (1 cement : 3 find sand) to give a smooth and even
surface centering and form work and curing
complete excluding cost of reinforcement.
Providing and laying controlled cement concrete
M.150 for curing complete excluding cost of
11 2.00 formwork and reinforcement for reinforced concrete work in Cum
(A) Foundations, footings,Base of 3,871.39
columns and Mass concrete
Providing and laying in position Ready Mixed M-
150 grade concrete for reinforced cement conctere
work, using cement content as per approved Design
Mix manufactured in fully automatic batching
plant and transported to site of work intransit mixer for a
lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding
12 5.00 the cost of centering shuttering finishing and Cmt
reinforcement including cost of admixtures
inrecommended proportions as per IS:9103 to
accelerate/ retard setting of concrete, improve work
ability without impairing strength and durability as per
direction of theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
Providing and laying in position Ready Mixed M-
200 grade concrete for reinforced cement conctere
work, using cement content as per approved Design
Mix manufactured in fully automatic batching
plant and transported to site of work intransit mixer for a
lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding
13 5.00 the cost of centering shuttering finishing and Cmt
reinforcement including cost of admixtures in
recommended proportions as per IS:9103 to
accelerate/ retard setting of concrete, improve work
ability without impairing strength and durability as per
direction of theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
Providing and laying controlled cement concrete
M.200for curing complete excluding cost of
14 5.00 formwork and reinforcement for reinforced concrete work in Cum
(A) Foundations, footings,Base of columns and Mass 3,977.88
Walls, from top of foundation level upto floor two level
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and
c 2.00 Cantilever upto floor two level. Cum
Columns, Pillars posts and struts upto floor two level.
Staircases excluding landing upto floor two level
Vertical and Horizontial its upto floor two level.
Providing and laying in position Ready Mixed M-
250 grade concrete for reinforced cement conctere
work, using cement content as per approved Design
Mix manufactured in fully automatic batching
plant and transported to site of work intransit mixer for a
lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding
15 5.00 the cost of centering shuttering finishing and Cmt
reinforcement including cost of admixtures in
recommended proportions as per IS:9103 to
accelerate/ retard setting of concrete, improve work
ability without impairing strength and durability as per
direction of theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be
maintained) (Cement level 450 kg )
Providing and laying controlled cement concrete M.250 and
16 curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work in
Foundations, footings, Base of columns and Mass concrete.
Walls, from top of foundation
C 2.00 level upto floor two leve Cu.M.
Slabs,landing,shelves,Balconies, Lintels, Beams,
D 2.00 Girders and Cantilever upto floor two level. Cu.M.
Columns, Pillars posts and
E 3.00 struts, upto floor two level. Cu.M.
Providing and laying in position Ready Mixed M-300 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of
laying, excluding the cost of centering shuttering finishing
and reinforcement including cost of admixtures in 5,043.66
recommended proportions as per IS: 9103 to accelerate/
retard setting of concrete, improve workability without
impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash (Min cement level as
shall be maintained)
Providing and laying in position Ready Mixed M-350 grade
concrete for reinforced cement conctere work , using cement
content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in
transit mixer for a lead up to 10 kms having continuous
agitated mixer, manufactured as per mix design of specified
grade for reinforced cement concrete work including
pumping of R.M.C. from transit mixer to site of
laying, excluding the cost of centering shuttering finishing
and reinforcement including cost of admixtures in 5,140.94
recommended proportions as per IS: 9103 to accelerate/
retard setting of concrete, improve workability without
impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash(Min cement level as
shall be maintained)
Providing and Laying ordinary cement concrete 1:2:4
(1-Cement 2-coarsesand: 4-graded stone aggregates
20 mm nominal size) and finishing smooth with curing
19 3.00 etc. complete including the cost of form work but excluding Cum
the cost of reinforsement for R.C.C work in (iv) Slabs
having more than 13 cm and upto 15 cm.thickness
Providing and Laying ordinary cement concrete 1:2:4
(1-Cement 2-coarsesand: 4-graded stone aggregates
20 mm nominal size) and finishing smooth with curing
20 3.00 etc. complete including the cost of form work but excluding Cum
the cost of reinforsement for R.C.C work in (iv) Slabs
having more than 8 cm and upto 10 cm.thickness
Providing and laying ordinary cement concrete 1:2:4 (1-
Cement 2- coarse sand : 4- graded stone aggregates 20 mm
nominal size) for R.C.C lintel including finishing smooth
21 3.00 with,curing etc. complete including the cost of formwork but Cum
excluding the cost of reinforcement.
Brick work using common burnt clay building
bricks having crushing strength not less than
22 35kg./Sq.Cm.in foundation and plinth in Cement
Mortar1:6 (1-Cement :6 - fine sand)
(A) Conventional (upto 10 ton)
Extra Rate for brickwork in Above Item for super
23 structure above plinth level upto floor two level (B)
(A) Conventional (upto 10 ton)
C) above floor two level Item No. 2(6.13) (A) Modular Per
c 10.00 Floor Per
D) above floor two level Item No. 2(6.13) (B) Conventional Per
d 10.00 Floor Per
Half brick masonry in common brunt clay building
bricks having crushing strength not less than 35 Kg/Sq.Cm.
24 20.00 in Cement mortar 1:5 ( 1-Cement : 5 coarse sand ) in Smt
foundation and Plinth conventional brickwork 593.90
Extra for half brick masonry in super structure above
25 10.00 plinth level upto floor two level (B) conventional Smt
Providing and laying Pre cast Light weight concrete hollow
core wall with hollow core concrete unit of approved
make & size of 92 mm thick, 600 mm wide and 2400 mm/
2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
made from of controlled cement concrete M20 having
26 2.00 cube compressive strength not less than 20 MP a jointing
with high strength & tensile adhesion non-shrink
cementitious joint compound /P.U. Foam. (Plaster not
Providing and laying Pre cast Light weight concrete hollow
core wall with hollow core concrete unit of approved
make & size of 120 mm thick, 600 mm wide and 2400 mm/
2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
made from of controlled cement concrete M20 having
27 2.00 cube compressive strength not less than 20MP a jointing
with high strength & tensile adhesion non-shrink
cementitious joint compound/ P.U.Foam. (Plaster not
Providing and laying Pre cast Regular concrete hollow
core wall with hollow core concrete unit of approved
make & size of 92 mm thick, 600 mm wide and 2400 mm/
2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
made from of controlled cement concrete M35 having
28 2.00 cube compressive strength not less than 35 MP a jointing
with high strength & tensile adhesion non-shrink
cementitious joint compound/ P.U.Foam. (Plaster not
Providing and laying Precast Regular concrete
hollow core wall with hollow core concrete unit of
approved make & size of 120 mm thick, 600 mm wide and
29 2.00 legth made from of controlled cement concrete M35 Sqm
having cube compressive strength not less than 35 MP a
jointing with high strength & tensile adhesion non-shrink
cementitious joint compound /P.U.Foam. (Plaster not
Providing form work in ordinary timber planking so as
to give a rough finish including centering, shuttering,
strutting and propping etc. height of propping and
30 centering below supporting floor to celling not exceeding
4 M & removal of the same for in situ reinforced or
plain concrete work upto floor four level
Foundation, footings, bases of columns etc. and mass
a 10.00 concrete. Smt
(B) Flat surfaces such as soffits of supspened floors slabs
b 20.00 Landings and the like. (1) Floors etc. upto 200 mm in Smt
thickness. 252.00
(B) Flat surfaces such as soffits of suspended floor roof
c 15.00 slabs Landings and the like. (2) Floors etc. above 200mm in Smt
thickness. 270.90
Vertical surface such as walls (any thickness) partitions and
d 20.00 the like including attached buttresses & string course & the Smt
(ii) Sides And Soffits Of Beam, Haunchings
e 20.00 Cantilevers, Girders, Bressumers And Lintels Not Smt
Exceeding 1 M In Depth. 192.15
(G) Columns PillarsPosts and struts. (1) Square Rectangular
f 15.00 Polygonal in plan. Smt
(2) Circular or curved in plan.
(H) (2) Sides and soffits of Beams Beam Haunchings canti-
h 20.00 levers Girders Bressumers and Lintels exceeding 1M.in Smt
Providing and fixing 35 mm thick shutters for Doors,
31 windows and clear story windows including anodised
alluminium butt hinges with necessary screws.
(A) Indian Teak Wood (ii) Fully Glazed.
(B) Indian Teak Wood (ii) Fully Panelled
(C) Indian Teak Wood (iii) Partly panelled and partly
c 2.00 glazed. Smt
Providing and fixing 35 mm thick shutters for Doors,
32 windows and clear story windows including black enamelled
M.S.butt hinges with necessary screws.
(A) Indian teak wood. (i) Fully Panelled.(upto 10 ton)
(A) Indian teak wood. (ii) Fully Glazed.(upto 10 ton)
(A) Indian teak wood. (iii) Partly panelled and partly
c 2.00 glazed. (upto 10 ton) Smt
Providing and fixing 35 mm thick panelled, glazed or
panelled and glazed shutters for Doors windows and clear
33 story windows including anodised alluminium But
hinges with necessary screws and indian teak wood
(A) Plywood sheet panels.
(B) Particle board panels
(C)Hard board panels.
(D) Asbestos sheet panels.
Providing and fixing 25 mm thick shutters for cup
boards etc. including black enamelled M.S. butt hinges
34 2.00 with necessary screws.(A) Indian teak wood. (i) Fully Smt
Panelled. (upto 10 ton)
Providing and fixing 25 mm thick shutters for cupboards etc.
including anodised alluminium
a 2.00 butt hinges with necessary screws. (A) Indian teak wood. (ii) Smt
Providing and fixing 25 mm thick shutters for cupboards etc.
including anodised alluminium butt hinges with necessary
b 5.00 screws. (A) Indian teak wood. (ii) Partly panelled and partly Smt
Providing and fixing plain asbestos cement sheet 6 mm
thick in partitions including fixing to fames with screws
35 2.00 etc, complete with 50 mm x 12 mm Deodar wood Smt
beading (Frames to be paid separately) (upto 10 ton)
Providing and fixing in partitions 4 mm thick medium hard
board of approved quality including fixing to fames with
36 2.00 screws etc complete with 50 mm x 12 mm teak wood Smt
beading (Frames to be paid separately) (upto 10 ton)
25 mm thick wooden shelves supported on 40 x
mm x 6 mm T or L iron brackets fixed at suitable
37 2.00 distances but not exceeding 75 cm. apart with Smt
Mango wood or equivalent quality. (upto 10 ton)
40 mm thick wooden shelves supported on 40 x
40mm x 6 mm T or L iron brackets fixed at suitable
38 2.00 distances not exceeding 75cm. Apart with Mango Smt
wood or equivalent quality. (upto 10 ton)
Providing and fixing M.S. round or square bars with M.S.
39 100.00 flats at required spacing in wooden frames of windows kg
and clerestory windows.(upto10 ton) 68.53
Providing and fixing M.S. grills of required pattern to
wooden frames of windows etc. with M.S. flats at
40 200.00 required spacings and frame alround, square or kg
round bars with round headed bolts and nuts or by screws 100.17
(A) Plain Grill. (upto 10 ton)
Providing and fixing M.S. grills of required pattern to
wooden frames of windows etc. with M.S. flats at
41 10.00 required spacings and frame alround, square or kg
round bars with round headed bolts and nuts or by screws 143.64
(A) Ornamental Grill. (upto 10 ton)
Providing and fixing glazed louvered glass
windows and ventilators with teak wood frame 10 cm.
42 10.00 x 7 cm. size including 3 coats of oil painting to wood Smt
work etc.complete. (upto 10 ton)
Providing and fixing glazed louvered glass
windows and ventilators with teak wood frame
43 10.00 cm.x7 cm. size including 3 coats of oil painting to Smt
wood work etc.complete.with wooden louvers plank 12mm 4,332.47
thick (upto 10 ton)
Providing and fixing 35 mm thick shutters for Doors,
windows and clere story windows including Indian
teak wood frames 10 cm x 7 cm. size including
44 2.00 anodized alluminium fixtures and fastenings including Smt
primer coat of approved quality and two coats of oil
painting etc, complete.(ii) Fully Glazed.
Providing and fixing 35 mm thick shutters for Doors,
windows and clere story windows including Indian
teak wood frames 10 cm x 7 cm. size including black
45 2.00 enamelled iron oxidixed fixtures and fastenings Smt
including primer coat of approved quality and two coats of
oil painting etc, complete.(ii) Fully Panelled.
Providing and fixing 35 mm thick shutters for Doors,
windows and clerestory windows
including Indian teak wood frames 10 cm x 7 cm. size
including anodized alluminium fixtures
and fastenings including primer coat of approved quality and 3,557.15
two coats of oil painting
etc, complete. (iii) Partly panelled and partly glazed.
Providing and fixing 30mm thick FACTORY MADE
SOLID BOTH SIDE PRELAM PANEL PVC DOOR
SHUTTER consisting of frame made out of M.S.tubes of
gauge thickness and size of 19mm x 19mm for stiles, top
and bottom rails. M.S. frame shall have a coat of steel
primer of approved makde
and manufactures. M.S frame covered with 5mm thick heat
moulded prelim PVC ‘C’ channel of siz 30mm thickness,
mm width of which 50mm shall be flat and 20mm shall be
tapered in 45 degree Angle on either side forming stiles, and
5mm thick, 95mm wide pream PVC sheet out of which
75mm shall be flat and 20mm shall be tapered in 45 degree
on the inner side ot form top and bottom rail and 115mm
wide prelim PVc sheet out of which
47 2.00 75nmm shall be flat and 20mm shall be - 75nmm shall be Smt
flat and 20mm shall be tapered on both side to form lock
rail, Top, bottom
and lock rails shall be provided either side of the panel.
10mm (5mm x 2) thick 20mm wide cross PVC sheet shall be
provided as gap insert for top rail and bottom rails. Panelling
of 5mm thck both side prelim PVC sheet to be fitted in the
M.S. frame welded,sealed to the stiles and rails with 7mm
(5mm + 2 mm) thick x 15mm wide PVC sheet beading on
inner side, and joined togeth with
solvent cement adhesive. An additional 5mm thick PVC strip
of 20mm width is to be stuck on the interior side of the ‘C”
chanel using PVC solvent adhesive etc. complete as per
direction of Engineering in charge, manufacture’s
specification and rawing.
Providing and fixing in position collapsible steel
shutters with vertical channels 20 x 10 x 2 mm braced
with flat iron diagonal 20 x6 mm size with top and bottom
rails T iron 40 x 40 x 6 mm with 38 mm dia steel pulleys
complete with bolts, units, locking arrangements, stoppers, 5,391.23
handles, including a priming coat of red lead paint &
Providing and fixing 1 mm thick M.S. sheet sliding
shutters with frame and diagonal braces of 40x40x6
mm angle iron, 3.15 mm M.S.gusset plates at Junctions
and corners 25 mm dia. pulley, 40x40x6 mm
49 1.00 angle and T-iron huide rail at top and bottom Sqm
respactively with handles, stoppers and locking
agangement etc, including applying a priming coat of
red lead paint. (upto 10 ton)
Providing and fixing rolling shutters of approved make made
of 80 mm wide M.S.laths inter-locked together
through their entire length and jointed together at theends by
end locks mounted on specially designed pipe shaft
with bracket plates, guide channels and
50 2.00 arragements for inside and out side locking with
push-pull operation including the cost of hood cover
and spring etc. complete. (A) Shutters having width
Providing and fixing rolling shutters of approved make made
of 80 mm wide M.S.laths inter-locked together
through their entire length and jointed together at theends by
end locks mounted on specially designed pipe shaft
with bracket plates, guide channels and
51 1.00 arragements for inside and out side locking with
push-pull operation including the cost of hood cover
and spring etc. complete. (A) Shutters having
Providing and fixing extruded aluminum window having
extruded aluminum Colour Powder Coated section frame
main outer size 127mm x 38.10mm x
1.35mm ,@ Wt.1.384 Kg/mt,horizontal Four track member
size 122.20mm x 31.75mm x 1.10mm @ Wt.
Kg/mt,vertical member of size 122.20mm x 31.75mm x
1.50mm ,@ Wt. 1.398 Kg/mt with sliding shutters of
52 1.00 horizontal member size 40mm x Smt
18mm x 1.29mm @ wt.of 0.456Kg/mt,vertical member of 2,119.14
size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt,@ with
mm thick transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
details etc complete for window.
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 63.50 x
38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track
member size 61.85 mm x 31.75 mm x 1.20mm @ wt.of
0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm
x 1.30 mm @ wt.of 0.659 Kg/mt with sliding shutters of
horizontal member size 40mm x 18mm x 1.29mm @ wt.of
53 1.00 0.456Kg/mt, vertical member of size 40mm x 18mm x Sq. M.
1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm
thick transparent bronze colour tinted float glass with powder
coated aluminum fittings
and fixtures and transparent silicon sealant glass fixing to
frame as per details etc complete for window.
Providing & Fixing in position Alluminium vents with
frame using approved anodised extruded alluminium
section as approved by Engg. In charge.(Jindal
alluminium) units equivalent Approved Rate)Frame
section of 63.50 x 38.50 mm. (wt. 0.68Kg/Rmt) incl. 1,288.93
Providing & Installing 5 mmthick approved color Acrylic
sheet of standard quality etc. comp.
Providing and fixing standared extruded of alluminium
section of size 63 mmx38.10 mmx1.2 mm (Jindal
55 1.00 Section:2434, @ Wt.0.643 Kg/mt) with colour Sq. M.
anodized alluminium frame for ventilation with 5 mm 1,163.92
thick frosted glass as details etc complete for Ventilation
Providing and fixing standared extruded of alluminium
section of size 63.50 x 38.10 x
56 1.00 mm,@ Wt 1.094Kg / Rmt with colour Powder Coated Sq.M.
alluminium frame with 5 mm thick transparent bronze colour 1,509.90
tinted float glass as details etc complete for Fix Partition
Providing and laying 40 mm thick marble chips flooring
rubbed and polished (I.E.terrazo) to granolithic finish with
under layer 30 mm thick cement concrete1:2:4 (1-Cement:
2-coarse sand: 4-graded stone aggregate 10 mm
and down gauge) and to player 10 mm thick with white,
black or white and blak marble cihps of required sizes from
57 1.00 mm to 4 mm nominal size laid in cement marble powder mix Sqm
3:1 (3- Cement:1-Marble powder by weight) in 749.70
proportion of 4:7 (4- Cement: 7-marble chips by
volume) (C) Medium Shade pigment with approx
50% white cement and 50% ordinary cement (In top layer
only) (upto 10 ton)
Providing and laying marble chips skirting (Terrazo) or
dedo rubbed, and polished to Granolithic finish to player
mm white, black or white and black marble chips of
size from smallest to 4 mm nominal size laid in cement
58 2.00 marble powder mix 3:1 (3-Cement: 1 marble powder Sqm
by weight) in proportion of 4:7 (4-cement marble powder
mix: 7-marble chips by volume) (B) Light shade pigment with
white cement (In top layer only)
Providing and laying white glazed tiles 6mm thick in flooring
treads of steps and landing laid on a bed of 12mm thick
59 2.00 cement mortar 1:3 (1-cement : 3-coarse sand ) finishing with Sq.M.
flush pointing in white cement.
Providing and laying Ceramic tiles 6 mm thick in flooring
treads of steps and landing laid on a bed of 12 mm thick
60 2.00 cement mortar 1:3 (1- cement :3-coarses and) finishing Sq.M.
with flush pointing in white cement. (upto 10 ton)
Providing & Fixing 2mm Aluminium / 4mmACP sheeting
fixed with Type-11 Class-C High Intensity Grade Sheeting as
61 2.00 per IRC 67 : 2012 reflective sheeting of size including Smt
lettering and signs as 5,832.20
Providing and laying Vitrified tiles 8 to 10 mm thick, 36''x36''
in flooring treads of steps and landing laid on a bed of
62 2.00 mm thick cement mortar 1:3 (1-cement:3-coarses and) Sq.M.
finishing with flush pointing inwhite cement. (upto 10 ton) 1,469.91
Providing and laying Vitrified tiles 8 to 10 mm thick, 24''x24''
in skrting risers of steps and dedo on 10 mm thick cement
63 2.00 plaster 1:3 (1- cement: 3-coarse sand) and Sqm
jointed with white cement slurry (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm thick, in skrting
risers of steps and dedo on 10 mm thick cement plaster
64 2.00 1:3 (1-cement:3- coarse sand) and jointed with white Sqm
cement slurry (upto 10 ton)
Providing and laying 24" x 24" vitrified Tiles 8 to
10 mm th. Double Charged gloosy/ Matt of Approved
make as approved by Adl.C.E. / consultants in flooring
over 20 mm thick cement mortar 1:6 (1 cement :
coarse sand)on new surface& jointed with colour cement 1,527.00
slurry incl with flush pointing & cleaning the surface
Providing and laying 24" x 24" vitrified 8 to 10 mm
th.Double Charged Gloosy / Matt tiles of Approved
make as Approved by Adl.C.E. / Consultants for upto
cm high skirting as approved by Engineer in charge
over 10 mm thick cement mortar 1:6 (1 cement : 6 coarse 165.00
sand)on new surface& jointed with colour cement slurry
incl with flush pointing & cleaning the surface etc. comp.
Providing and laying polished Kota stone slab flooring over
20 mm (Average) thick base of cement mortar 1:6
(1-cement:6-coarses and) or L.M.1.1.5 (1-Lime
putty:1.5-coarses and) laid over and jointed with grey
cement slurry mixed with pigment to match the shade of 982.83
slab including rubbing and polishing etc. complete. (A)
mm thick (upto 10 ton)
Providing and laying marble stone slab flooring over 20mm
(average)base of cement mortar 1:6 (1-cement : 6 coarse
sand) or L.M. 1:1.5(1- lime putty : 1.5 - coarse sand) laid and
68 2.00 jointed with gray cement slurry including rubbing and Sq.M.
polishing complete. (A) Marble slab 25mm
Providing and laying polished Kota stone slab flooring over
20 mm (Average) thick base of cement mortar 1:6
(1-cement:6-coarses and) or L.M.1.1.5 laid over and
69 5.00 jointed with grey cement slurry including rubbing and Sq.M.
polishing etc.complete. (B) 30 mm thick (upto 10 ton)
Providing and laying polished kota stone slab 25 mm thick in
risers of steps, skirting Dedo and pillars laid on 10 mm thick
cement mortar 1:3 (1-Cement :3 coarses and) and
70 5.00 jointed with gray cement slury mixed with pigment to Sq.M.
match the shade of slab including rubbing and
polishing etc.complete. (upto 10 ton)
Providing and laying cement concrete flooring 1:2:4
(1-cement: 2-coarses and:4-graded stone aggregate
71 2.00 20mm nominal size) laid in one layer and finished with a Sq.M.
floating coat of neat cement. (A) 40mm thick. (upto 10 297.68
Providing and laying cement concrete flooring 1:2:4
(1-cement: 2-coarse sand:4-graded stone aggregate
72 5.00 20mm nominal size) laid in one layer and finished with a Sq.M.
floating coat of neat cement. (B) 50mm thick. (upto 10 348.08
Providing and fixing pre-cast concrete kerb stone
of gray cement based concrete block 30 cm length,
cm height and 15 cm thick of M200 grade concret as per
73 5.00 approved design and including excavation for fixing in Rmt
proper line and level, filling the joint with C:M 1:3 (1 cement
:3 fine sand) etc complete. (upto 10 ton)
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and as
per approved design Confirming to IS 15658 : 2006 including
35 mm Sand layer for levelling and filling the joint with sand 680.10
in proper line and level as per guidlines of IRC : SP 63-2018
Providing and laying broken china mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed tiles
to be laid over cement mortar 1:3 to plain or slope and to be
tempered to bring mortar creme out upto surface using
white cement including rounding off junctions and 739.89
extending them up to15 cm along the wall, clearing with
water and oxalic acid etc.asdirected.
Providing and laying coloured glazed tiles of the
size 300 mmx200 mmx8 mm/300 mmx450 mmx8 mm
76 10.00 in skirting, risers of steps and dedo on 10 mm. thick Sqm
cement plaster 1:3 (1cement: 3 coarse sand) & 1,426.95
jointed with white cement slurry.
Providing corrugated G.I. sheet of class-3 roofing
fixed with glavanished iron J or L Hooks, Bolts and
nuts 8 mm diameter with bitumen and G.I. limpet washer or
77 10.00 G.I. limpet washer. filled with white lead complete excluding Sqm
the cost of purlins, Rafters and Trusses. (1) 0.80 mm thick
sheet.(up to10 ton)
Providing ridges or hips 600 mm over allin plain G.I.
sheet class-3 fixed with G.I. J or L Hooks and nuts
mm dia G.I. Limpet and bitumen washer complete. (1) 635.58
Providing and fixing 150 mm wide 450 mm over all semi
circular plain G.I.sheet class-3 gutter with Iron brackets
79 10.00 mmx3 mm size Bolts, Nuts, washers etc. including Sqm
making necessary connection with rain water pipes. (i) 0.80 555.71
Providing and fixing five courses water profing
treatment with bitumen felt consisting of second and
fourth course of blown/ bitumen or/and residual
bitumen applied hot at 1.2 kg.per Sq.M.of area for
each course and first course with fibre base bitunen
saturated under lay type land third course with fibre base
80 10.00 self finished felt type 2 grade 1 and fifth and final course Sqm
of stone grit 6 mm and down size or pea sizes gravel
spread at 0.008 Cu.Metre/Sq.metre
preparation of surface excluding grading complete. (upto
10 ton) including
Providing and fixing on wall face C.I. Rain water pipe
including filling the joints with spun yarn soaked in neat
81 20.00 cement slurry and cement mortar 1:2(1- Cement : Rmt
2-fine sand) (A) 75 mm dia.
Providing 15 mm thick cement plaster in single coat
on Rough (Similar) side of single or half brick walls for
82 1000.00 interior plastering up to floor two level and finished even Sqm
and smooth in (i) Cement mortar 1:3 (1-cement :3-sand) 174.83
Providing 20mm thick sand faced cement plaster on walls
upto height 10 metres above ground level consisting of
83 500.00 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) Sqm
and 8mm thick finishing coat of C.M. 1:1 (1-cement : 1-sand) 215.78
Colour washing with lime on wall surface (two coats)
over and including a primary coat of white washing to
84 5000.00 give an even shade after through brooming the surface to Sqm
remove all dirt, dust, mortar drops and other foreigh 12.29
Removing dry or oil bound distemper by a
washing and scraping and sand papering the wall
85 1500.00 surface smooth including necessary repairs to Sqm
scratches complete.
Distempering with dry distemper of approved brand and
manufacture (two coats) and of required shade on wall
surfaces of given an even shade, over and including
86 3500.00 a priming coat of whiting after thoroughly brooming Sqm
the surface free from mortar dropping and other
foreign matter.
Extra Coat for Above Item over above for every
87 1000.00 subsequent coat of approved brand and manufacture. Sqm
Distempeing (Two coats) with oil bound distemper of
approved brand and manufacture and of required
shade on wall surfaces to give an even shade, over
and including a priming coat with distemper primer
of approved brand and manufacture after
88 5000.00 thoroughly brushing the surface free from mortar
dropping and other foreign matter and also
including preparing the surface even and sand papered
Extra Coat for Above Item over above for every
89 2000.00 subsequent coat of approved brand and manufacture. Sqm
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated
90 10500.00 wall surface to give an even shade including throughly Sqm
brushing the surface free from mortar droppings and 78.44
other foreign matter and sand papered smooth.
Extra over item for every sub sequent coat of wall
91 2000.00 painting with plastic emulsion paint of approved brand Sqm
Extra over item for painting with plastic emulsion paint of
92 2000.00 approved brand on ceilings and sloping roofs. smt
Applying priming coat over new steel and other metel
surface after and including preparing the surface by
throughly cleaning, oil, grease, dirt and other
93 2000.00 foreign matter and scoured with brushes fine steel wood, Sqm
scrapers and sand paper with ready mixed priming
paint brushing red lead.
Painting two coats (excluding priming coat) on new
steel and other metal surface with enamel paint,
94 1000.00 brushing, interior to give an even shade including Sqm
cleaning the surface an even shade including cleaning the 86.94
surface of all dirt, dust and other foreign matter.
Painting one coats (excluding priming coat) on
previously painted steel and other metal surface with enamel
95 500.00 paint, brushing to give an even shade including cleaning Sqm
the surface of all dirt, dust and other foreign matter. 54.35
Extra over item for 83 & 84 every sub sequent coat of paint.
Painting two coats (excluding priming coat) on new
steel and other metal surface with synthetic enamel
97 500.00 paint, brushing to give an even shade including cleaning Sqm
the surfaceofalldirt,dust and other foreign matter.
Painting one coats (excluding priming coat) on
previously printed steel and other metal surface with
98 500.00 synthetic enamel paint, brushing to give an even shade Sqm
including cleaning the surface of all dirt, dust and other 43.79
foreign matter.
Extra over Above item for 86 & 87 for every sub
99 500.00 sequent coat of paint. Sqm
Painting two coats (excluding priming coat) on
external surface of new rain water, soil, waste and vent
100 500.00 pipes and fittings with ready mixed bituminous brushing, Sqm
black, anti corrosive to give an even shade including 20.16
cleaning of all dirt, dustand other foreign matter.(75 mm dia)
Painting two coats (excluding priming coat) on
external surface of new rain water, soil, waste and vent
pipes and fittings with ready mixed bituminous brushing,
101 500.00 black, anti corrosive to give an even shade including Sqm
cleaning of all dirt, dust and other foreign matter.(100 mm
Painting two coats (excluding priming coat) on new
wood and wood based surface with enamel paint,
interior to give an even shade including cleaning
102 500.00 the surface of all dirt, dust and other foreign matter Sqm
sand papering and stopping. (a) Ready mixed paint
brushing wood primier pink.
Painting one coats (excluding priming coat) on
previously painted wood and wood based surface with
103 500.00 enamel paint, to give an even shade including cleaning the Sqm
of all dirt, dust and other foreign matter.(b) Ready mixed 40.17
paintbrushing priming for enamel
Extra over Above item for 91 & 92 every sub sequent
104 500.00 coat of paint. Sqm
Painting two coats (excluding priming coat) on new
wood and wood based surface with ready mixed
105 650.00 paint, brushing, oil, gloss, semi gloss to give and Sqm
even shade including cleaning of all dust, dirt and 104.12
other foreign matter sand papering and stopping.
Providing 15 mm thick cement plaster by using Ready Mix
Mortar for plaster in single coat on rough (similar) side of
106 750.00 single or half brick walls for Sqm
interior plastering upto floor two level and finished even and 170.14
smooth in Cement mortar 1:4 (1 Cement : 4 sand)
Applying two coats of putty & two coats of primer
of approved brand and manufacture on new wall
107 6000.00 surface to give an even shade including thoroughly Sqm
brushing the surface free from mortar dropping and 40.19
other foreign matter and sand papered smooth.
Painting two coats (excluding priming coat) on new
wood and wood based surface with enamel paint,
108 600.00 interior to give an even shade including cleaning Sq.M.
the surface of all dirt, dust and other foreign matter 87.11
sand papering and stopping.
Writing letter or figures on any surface with black
japan paint (stops, comas, hyphens and the like not to per letter
109 500.00 be measured and paid for separately) (i) Block per
(Letters/Figures) (Per 10 Letter pet CM.HT) Cm/Ht
Extra over items for using thick white paint instead of per letter
110 500.00 black japan paint. (i)Block (Letters/Figures) per
Polishing with french polish on new wood and
wood based surface to give an even
111 150.00 surface including cleaning, the surface of all dirt, dust and Smt
sand papering smooth and including a coat of wood 131.67
Extra over items for using thick white paint instead of per letter
112 20.00 black japan paint. (ii) Indian (Letters/Figures) 0.07 perCm/Ht
Painting lines, deashes, arrows, letters etc on roads, Air
fields and like in two coats with road marking paint, brushing
113 50.00 including cleaning the surface of all dirt, dust and other Sqm
foreign matter. (i)Over 10cmi n width
Painting lines, deashes, arrows, letters etc on roads, Air
fields and like in two coats with road marking paint, brushing
114 50.00 including cleaning the surface of all dirt, dust and other Rmt
foreign matter.(ii) Upto 10 cm in width
Painting lines, deashes, arrows, letters etc on roads, Air
fields and like in one coats with road marking paint, brushing
115 50.00 including cleaning the surface of all dirt, dust and other Sqm
foreign matter. (i) Over 10cm in width
Painting lines, deashes, arrows, letters etc on roads, Air
fields and like in one coats with road marking paint,
116 100.00 brushing including cleaning the surface of all dirt, dust Sqm
and other foreign matter. (ii) Upto 10cm in width
Demolition including stacking of serviceable materilas
117 10.00 and disposal of unserviceable materials with all lead and Cu.M.
lift. (i) R.C.C. work 1,047.38
Demolition of Brick work and stone masonry including
stacking of serviceable materil as and disposalof
118 10.00 unserviceable materials with all lead and lift.(ii) In Cement Cu.M.
Demolition of terrace including stacking of serviceable
119 10.00 materilas and disposal of unserviceable materials with all Smt
lead and lift.(i) Brick tile covering. 63.00
Dismentaling tiled of stone floors laid in mortar including
120 10.00 stacking of serviceable materil as and disposal of Sqm
unserviceable materials with all lead and lift. 47.25
Dismentaling of sheet roofing including ridges, Hips,
Valleys, Gutters etc. stacking of serviceable materil as
121 10.00 and disposal of unserviceable materials with all lead Sqm
and lift.(i) G.I.sheet roofing.
Dismentaling of sheet roofing including ridges, Hips,
Valleys, Gutters etc. stacking of serviceable materil as
122 15.00 and disposal of unserviceable materials with all lead Sqm
and lift.(i) A.C. sheet roofing.
Dismentling steel work including distempering and
123 15.00 stacking the materials with all lead and lift. Kg.
Dismentling doors, windows, ventilators etc. (wood
or steel) shutters including chowkhats architraves,
124 5.00 hold fasts and other attachment etc. complete and Each
stacking the material within all lead and lift.(i) Not exceeding 185.85
3 Sq.M. in area.
Dismentling doors, windows, ventilators etc. (wood
or steel) shutters including chowkhats
125 5.00 architraves,hold fasts and other attachment etc. Each
complete and stacking the material with in all lead and 248.85
lift.(ii) Exceeding 3 Sq.M.in area.
Dismentling barbed wire in fencing including making rolls
and also including dismentling fencing posts including all
earth work concrete in base and making good the
disturbed ground stacking useful materials as
directed and disposing as directed and 66.15
disposing of the unserviceable materials with all lead
Dismentling C.I. pipes G.S.W. pipes abd A.C. rain
127 5.00 water pipes with fittings and clamps including stacking Rmt
the materials with all lead and lift (for any dia, of pipe) 74.03
Dismantling santtary fittings like wash basin . W.C. pan
128 5.00 Indian and Europe an type, flushing tank etc. including Each
stacking the materials with all lead and lift 401.63
Scraping oil paint from steel and other metal surface
129 2000.00 and making the surface even (with Hand Scraping.) Smt
Removing and scraping of old deteriorated plaster
of any thickness from wall / R.C.C member
130 3500.00 including stacking of serviceable material and disposal Smt
of unserviceable from site of work with all lead and lift
Providing and fixing M.S. fan clamps of shape
131 50.00 and size as specified in existing R.C.C. slab including Each
cutting chase and making good. 168.53
Cutting out cracks of roof terrace to V-section, cleaning
132 100.00 out, wetting, grouting with cement and sand slurry 1:3 Rmt
(1-cement 3-sand ) (upto 10 ton) 64.58
Cutting out cracks roof terrace to V-Section cleaning out
133 50.00 and filling solidly with a hot mixture of bitumen Rmt
and clean dry sand (1:1 by weight) (up to 10 ton) 75.29
Providing & Fixing in position Alluminium doors with
frame using approved quality anodised extruded
alluminium section as approved by Engg.in charge(Jindal
alluminium)(a) Frame sections 101.6x44.45 mm
(b) Shutter bottom vertical & top section
83.5x44.45 (wt.1.31 kg/mt.)(at 1.31 kg/mt) (c) Shutter
134 2.00 bottom section at 114.3x44.45 mm at (1.37 kg/mt) Shutter Sq. M.
middle section at 100x44.3 wt.(1.37 kg/mt) incl.providing 2,900.00
& installing 5 mm thick approved color Acrylic sheet
of standard quality fixed with glazing chips on upper
pannel & Laminated sheet on lower pannel (wtt.0.13
kg/Rmt) etc.comp.as direction of engg.in charge.(N.S.)
Providing & Fixing in position Alluminium window sliding / fix
type with frame using approved anodised extruded
alluminium section as approved by Engg. In charge.(Jindal
alluminium) units equivalent (a) Frame sections 65 x 25 mm
( at 0.41 kg/mt) (b)Sliding Frame bottom section of 61.85 x
135 2.00 31.75 mm (at 0.41 Kg/Rmt) © Shutter top & bottom section Sq. M.
40 x18 mm ( wt. 0.41 Kg/Rmt ) (d) Shutter interlock vertical 2,350.00
section 10 x 18 mm.( 0.41 Kg/ Rmt) (e) Shutter vertical of
x 18 mm. (0.41 Kg/Rmt) including P/F installing 5 mm thick
approved color Acrylic sheet of standard quality etc.comp.
Supplying and fixing C.I. cover 300mm x 300mm without
136 2.00 frame for Gulley trap (Standard pattern) te weight of cover to Each
be not less 4.53 Kg.) 491.80
Providing and fixing standared extruded of alluminium
section of size 63.50 x 38.10 x 1.95 mm,@ Wt 1.094Kg /
137 1.00 Rmt with colour Powder Coated alluminium frame with Sq. M.
5 mm thick transparent bronze colour tinted float glass as 1,815.14
details etc complete for Fix window.
Providing and fixing of Ridge flashing for roof
panel shall be made out of 0.5 mm thick pre
coated GI sheet. The Pre coatedsheet shall be of
minimum 240 mpa steel grade confirming to IS
14246:1995 and shall have zinc coating of minimum
gsm as per IS:277:1992, 5-7 microns epoxy primer
on both side of the sheet and polyester top coat 15-18
138 2.00 micron. The PP GI Sheet shall have plastic Sqm
protective guard film of minimum 25 microns to avoid
scratches during transportation. The ridge shall be fixed
to the steel members by poprivetor self drilling/self
stitching fastners @ maximum 450mm c/c along length of
capping/flashing etc complete .
Supplying and fixing vinyl flooring over the surface
139 10.00 having 1-2 mm thickness as per directed by Smt
engineer incharge etc as completed (N.S.) 963.00
Providing and laying 15mm bamboza wooden
flooring as per architect's drawing with all
necessary details as directed by the project
140 5.00 consultants. Use underlay for better result as per Detail Smt
specifications and directed by the project consultants.
(N.S.) Approved Rate )
Providing and fixing 1.20 Metre high fencing with
Metre long M.S. Angle posts 40 mm x 40 mm x 6 mm and
oil painting 3 coats fixed at 2.5 Mt, C/c. with five
Horizontan lines and two diagonals of galvanised steel
141 20.00 barbed wire weighting 9.38 Kg. per 100 Metre, strained Rmt
and fixed to posts with G.I, staples including fixing
the posts in ground with 0.5 M x 0.5.M x 0.5 M. block in
C.C 1:5:10 etc complete.
Constructing a sink (chowkedi) with C.C. 1:2:4, 12 cm.
thick over B.B. masonry in C.M, (1:6) in front and dwarf wall
142 5.00 1.0 Mt. high and 23 cm. thick cement plaster to Rmt
masonry / in C.M.1:3) and cement concrete flooring in 2,235.66
1:2:4: mix 5cm.dia.drain pipe etc.complete.
Constructing a cooking platform 60 cm. width and 70 cm
high resting on B.B. Masonry walls 23 cm. thick in C.M.
(1:6) with (i) Fixing or precast R.C.C. 1:2:4) 8 cm.
143 5.00 thick slab with marble chips set in C.M. (1:6) (6 mm thick Rmt
terrazo) with plastering on exposed faces walls in C.M.
(1:4) etc complete.
Making 15 mm groove in RCC work on road and filling it with
144 5.00 polysulfied selant and finished it good incl. all all labour Rmt
charges etc. comp as directed 30.00
P/A Tremix with dewartering machine and floater
machine on constructed CC work for finishing the
surface as per requirement. The rate including all
145 5.00 machinaries, labor, loading, unloading, Sq.M.
transportaion etc complete as per direction given by
engineer incharge.
Carring out timber treatment to all wood work including
drilling holes and spraying oil based chemical solution on
surface of timber work for termite control including labour
and material etc. complete. Using Chlordene 20 EC.
As Per 6113_part III Consentration Weight1.00 percent is
146 5.00 recommended one litre chemical emulsion dillute with 9 Smt
liter of kerosene precent concentration. Total 54.98
dillute concrentration will be 10 litre inclusive of
the litre chemical emulsion appication 0.75 / Litre
chemical per one Sqmt printed two coat wood surface.
Applying general insecticide pest control treatment to
floors, cup boards etc including labour material
etc. complete. Using Heptachloride 20 EC. As
Per 6113_pests Consentration Weight 0.50 percentis
recommended one litre chemical emulsion dillute with
147 5.00 liter of water will give. Total dillute concrentration will be
40 litre inclusive of one litre chemical emulsion
appication 0.5 Litre chemical / Sqm of surface is
recommended as per I.S
Carring out plinth treatment to post construction / existing
structure by spraying chemical solution for termite
control treatment including labour and material consist
ment with I.S. specification. Using Chlordene and
Chior purfiles 20 EC. As Per 6131_paret-II
148 5.00 Consentration Weight on percentis recommended i.e one Smt
litre 20 EC chemical emulsion with 19 liter give 1% 104.90
concrentration inclusive of one litre chemical
emulsion appication attherate of 5 Litre chemical /
Sqm of surface is recommended as per I.S
Carrying out wall treatment for termite control
including spraying with chemical solution in oil base (0.5
Lit./Sq.M.) including labour and material Using
Hepachlor concentration 20 EC. As Per
IS.6316_paret-II Consentration by Weight
149 5.00 percentis recommended i.e one litre chemical Smt
emulsion dillute with 39 liter go fIS concrentration 37.34
total dillite concentration will be 40 litre inclusive of one
litre chemical emulsion appication at the rate of 7.5 Litre
chemical / Sqm of surface is recommended as per I.S
Providing erecting and fixing double coated Syntex
PVC.(ISI) water tank of required capacity each with all
150 5.00 necessary fittings and connection etc. complete on Litre
Providing and fixing to wall, ceiling and floor galvanised
Mild steel tubes (Medium grade) of the following
151 nominal bore, tube fitting and clamps including making good
the wall ceiling and floor.
(A) 15mm (upto 10 ton)
(B) 20mm (upto 10 ton)
(C) 25mm (upto 10 ton)
(D) 32mm (upto 10 ton)
(E) 40mm (upto 10 ton)
(F) 50mm (upto 10 ton)
Providing and laying in trenches galvanised mild
steel tubes (Midium grade) of the following nominal
152 bore, and tube fitting (Earth work in trenches to be
measured and paid for separately)
(A) 15mm (upto 10 ton)
(B) 20mm (upto 10 ton)
(C) 25mm (upto 10 ton)
(D) 40mm (upto 10 ton)
(E) 65mm (upto 10 ton)
(H) 80mm (upto 10 ton)
Making connection of galvanised Mild steel distribution
branch with galvanised mild steel main 50 mm to 80 mm
153 2.00 nominal bore by providing and fixing tee including Each
cutting and threading the pipes complete.
Providing and fixing to wall ceiling and floor 6.0 Kg.F/Cm2
working pressure poluthene pipes of the following out
154 side Dia. Low densidy, complete with special
falnge compression type fittings,wall clips
etc.including making good the wall ceiling and floor.
Providing and fixing to wall ceiling and floor
10.0Kg.F/Cm2 working pressure polythene pipes of the
following out side Dia. Low densidy, complete
with special falnge compression type fittings, wall
clips etc. including making good the wall ceiling and
Providing and fixing cast iron (Spun) Nahni trap of
the following nominal diameter of self cleaning design
156 5.00 with C.I. screaed down or higned grating including Each
cost of cutting and making good the walls and floor 100 mm 600.08
inlet and 50 mm outlet.(C)100mm dia.
Providing and fixing water closet squatting Pan
(Indian type W.C.Pan) size 580 mm (Earth work,
157 5.00 bed concrete, foot rest and trap to be measured and Each
paid for separately) (A) Vitreous China. (I)Long pattern = 926.10
Provdg. & fixing wall mounted White / Color
Vitreous China European water closet with
158 2.00 integral P trap of "Cera" - Clair Series or equivalent No.
incl. seat cover , Chair Bracket etc. complete as per 4,250.00
direction of engg. In charge.(N.S.)
Providing and fixing wsh down water closet (Europe
an type, W.C.Pan) with integral P or S trap including
jointing the trap with soil pipe in Cement Mortar1:1
159 5.00 (1- Cement:1-fine sand) (Seal and cover to be measured Each
and paid forseparately) (A) vitreous China Pattern :(i)
in white colour
Providing and fixing Urinal of approved quality
including connection with trap and with integral
160 5.00 longitudinal flush pipe.(A) Squating plate pattern No.
white earthenware 550mm x 300mm.
Providing & Fixing Angle cock of " Ess Ess" - Trend
161 5.00 series or equivalent standard make as approved by No.
engg. in charge all complete. (N.S.) 403.39
Providing & Fixing pillar cock of " Ess Ess" - Trend
162 5.00 series or equivalent standard make as approved by No.
engg. in charge all complete. (N.S.) 641.53
Providing and fixing 100 mm size P or S trap for
water closet squatting pan including jointing the trap with
163 5.00 the pan and soil pipe in cement Mortar1:1 (1-Cement : Each
1-Fine sand)(A) Vitreous China.Pattern in white colour
Providing and fixing washbasin with single hole for
pillar tap with C.I. or M.S. brackets painted white
including sutting holes and making good the same
164 5.00 but excluding fittings.(A) Vitreous China:(ii) Flat Each
Back washbasin 550 mm x v 400mm size. (i) In
Providing and fixing Kitchen sink with C.I. or M.S.
brackets, painted white including cutting holes in walls
165 2.00 and making good the same but excluding fittings. © Each
Vitreous China Sink. (i) 600 mm x 450 mmx 150 mm size
Providing and fixing 600 mm x 450 mm bevelled edge
mirrror of superior glass mounted on 6 mm thick A.C.
166 2.00 sheet or ply wood sheet and fixing to wooden pluge with Each
C.P. brass screws and washers.
Providing and fixing chromium plated brass halftrun flush
167 cock of approved quality including
fixing in pipe line etc. complete.(ii) 25mm dia.
Provdg. & fixing White / Color Vitreous china Counter
wash basin with signle hole for pillar tap of "Cera " -
Concord series of 550 x425 mm size to be fiited in stone
counter with necessary brackets painted white incl.
cutting holes and making good the same .Cost Includes
168 1.00 P/F C.P. brass waste coupline, 32 mm dia fisher union
,15 mm dia. Pillar cock & Angle cock of " Ess Ess"-
Trend series ,32 mm dia. Waste pipe etc. complete
as per dir. of engg. in charge.
Finishing wall with water proofing cement paint of
on wall surfaces (Two coats) to give an approved
brand and manufacture and of required shape
169 650.00 even shade after thoroughly brushing the surface to Smt
remove all dirt and remains of loose powered
Extra over Item 156 for every subsequent coat of
170 500.00 water proofing cement paint of approved brand Smt
and manufacture. 31.82
Providing & Fixing S.S.304 Grade Sink of Nirali /
171 1.00 Krishna or Equivalent Make for Kitchen Platform of No.
size : 24":x18" as per Direction of engg. In charge 4,650.00
Providing and fixing Kitchen sink with C.I. or M.S.
brackets, painted white including cutting holes in
172 1.00 walls and making good the same but excluding Each
fittings. (C) Vitreous China Sink.(i) 600mm x 450mm 2,257.69
Providing and fixing C.P. brass towel rail comlete with
173 1.00 C.P.brass brackets fixed to wooden plugs with C.P. Each
brass scews.(B) 600mm x 20mm size. 597.22
Providing and fixing 600 mmx120 mm glass shelf with
174 1.00 C.P. brass bracket and guard rail complete mixed to Each
wooden plug with C.P.brass screws. 561.03
Providing and fixing toilet paper holder. (A) C.P.Brass
Providing and fixingof S.S. Railing pipe 50 mm x 16 G ASIS
176 2.00 304 Grade as per instruction of engineer in charge.
Providing and fixing screw down bib taps of following size.
177 (B) Brass chromium plated screws down Bib Tap.
Providing and fixing screw down bib taps of following
178 size. © Gun metal screw down bib tap.
Providing and fixing pillar tap, capstan head, screw
179 down high pressure with screws, shanks and back nuts.
Providing and fixing Gun metal check or non-return
180 fullway wheel valve.
(III) 25 MM DIA
Providing and fixing brass screw down stop tap.(A) 15 mm
181 15.00 dia Each
Providing and fixing chromium plated brass half trun
182 flush cock of approved quality including fixing in pipe line
(iii) 32mm dia.
Providing and fixing Urinal or approved quality
including conecting the Urinal with waste pipe , tap
183 5.00 etc.complete. (A) White earthen ware flat back or corner Each
type size 430mm x 260mm x 350mm.
Providing and fixing chromium plated, bottle trap with
184 1.00 necessary couplings of approved quality for wash basin. Each
Providing and fixing ball cock ofapproved quality as
185 5.00 directed. (A) Copper Metal (i) 25mm dia. Each
Providing and fixing ball cock ofapproved quality as
186 5.00 directed. (A) Copper Metal (i) 50 mm dia. Each
Filling with good Quality thor as and where directed
by the Architect / Engineer-in-charge, in sunk in layers
187 1.00 of 15 cm. thickness, including watering, ramming well etc. Cmt
complete, as directed by the Architect / Engineer-in- 3,850.00
Providing laying and jointing in true line and level 15 mm
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings make PRINCE/ SUPREME/ ASTRAL/ FINOLEX or
equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
188 15.00 every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing
of pipe and joints and fixing the same with solvent,
including cost of all materials.adhesive
Providing laying and jointing in true line and level 25 mm
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings make PRINCE/ SUPREME/ ASTRAL/ FINOLEX
orequivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
189 10.00 every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing
of pipe and joints and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level 32 mm
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings make PRINCE/ SUPREME/ ASTRAL/ FINOLEX or
equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
190 3.00 every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing
of pipe and joints and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level 40 mm
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings make PRINCE/ SUPREME/ ASTRAL/ FINOLEX or
equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
191 5.00 every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing
of pipe and joints and fixing the same with adhesive solvent,
including cost of all materials.
Providing laying and jointing in true line and level 50 mm
dia. U.P.V.C. Pipe (SCH-40) for cold water including
fittings make PRINCE/ SUPREME/ ASTRAL/ FINOLEX or
equivalent as approved by Engineer In Charge.
Pipe shall be fixed on the wall with the help of clamp at
192 2.00 every two metre C/C or shall be concelled as
directed including necessary fittings etc. including testing
of pipe and joints and fixing the same with adhesive solvent,
including cost of all materials.
Providing and fixing premoulded compressible filler board in
black colour confirming to MoRT&H Specifications (Clause
1015), having minimum density 95kg/cum. non-staining with
less than 1% water absorption & compression recovery of
93% minimum as per specification for 20 mm wide 788.78
expansion joint including cutting to required size and shape
at all levels etc.complete as directed.
Fixing sun film for protection sunlight in black or any colour
194 2.00 as as directd by engineer In Charge.(Market rate) Smt
Providing & Fixing 3 mm thick F.R.P.sheet of
Approved Quality & Color / Pattern as per Consultant's
design also includes required fabrication structure in
the grid of 2'-0x2'-0 size using hollow pipe of16 gauge &
size 2"x1" & 1"x1" ,G.I. & Bitumen Washers, Silicon
195 5.00 paste application for fixing the sheet . Rate also
includesnecessary bending, cutting, labor charges , Zinc
Primer coat & Two coats of oil painting of color as
approved by consultants & making good the wall. (N.S.)
Providing 2 mm thick F.R.P. Gutter with necessary M.S.
196 2.00 Supporting Brackets. (N.S.) Rmt
Hiring charges for J.C.B.machine inclduing cost of fuel,
197 2.00 operator, dirver etc.. ( 12 hours sift day/night) Hrs.
To provide tractor with hydraulic trolley, driver, 4 Nos. of
Labor with all tools like bucket drum, showels, trikam,
pavadas, etc,, to carryout different works during
198 2.00 monsoon for 12 Hrs. Shift. Work shall be carried out No.
as per the instrucitons of Engineer In-Charge.No extra
charged shall be paid for night shift.
Roller Blind Providing and fixing Roller Blind curtain
fixed on window level on wooden batten and curtain
lift with cotton thin rope, make of aerolax or
199 5.00 equivalent design and colour as per instruction by Smt
engineer – in – Charge with necessary hardware fitting,
material and labour etc complete.
Providing & Fixing Door closer - complete of Approved make
200 5.00 to wooden / Aluminium Doors as per direction of engg. In No.
Providing and fixiing M.S. Fan clamps type 1 of 16 mm dia
M.S. bar bent to shape with hooked ends of R.C.C. slabs
201 2.00 during laying incl. painting the exposed protion of loops, all No.
as per standard design complete.
Providing cement vata (10cm. x 10 cm. size) quarter round
202 1.00 in cement mortar 1:1 including neat cement finishing, Rmt
watering etc. complete. 23.45
Making Water connection from exi.Muni. Water line (N.S.)
Applying and providing Expansion joint sealing
System on 100 mm vide joint including cleaning of
exansion joint by mechanical means provision of
adhesive and flexible membrane with required
bond length as per menufracturer specification and
204 1.00 4mm thick alluminium strip covering with one side
sloted and bolted with suitable system, inclusive of
all manpower, machinery and material as per
specification and as directed.
Providing and Fixing 1 H.P. Electrical monoblock or
submarcible water pumps withmotor and required cable and
205 1.00 switch board of approved brand and make etc.comp.as Set
.Providing TMT Bar FE 415 reinforcement for R.C.C. work
206 20.00 including bending, binding and placing in position complete Kg.
up to floor two level (up to 10 ton) 66.59
ProvidingTMTBarFE500/500Dreinforcement for
R.C.C.workincluding bending,binding and placing in position
207 20.00 complete upto floor two level placing in position complete Kg.
upto floor two level placing in position complete upto floor 75.46
two level(upto 10 ton)
Providing and fixing 30mm thick solid both side prelam PVC
208 1.00 door shutter (sintex door-equivalent) with necessary Smt
alluminium fitting with EL-7 section frame 2,214.00
Conveyance charge of Earth,Lime, Murrum, building rubbish
209 50.00 earch manure or sludge and excavated rock and fly Cu.M.
ash,aggregate of any kind etc.comp.upto 5 km lead.(L.S.) 326.73
Providing and laying polished granite stone slab 18 mm thick
in risers of steps, dedo and pllars laid on 10 mm thick
210 5.00 cement mortar 1:3 (1 cement:3 coarse sand) and jointed Smt
with gray cement slurry including rubbing & polishing 2,690.00
Wall panelling with 12 mm MDF fixed to existing
alluminium framing and making grove as per design and
211 1.00 finished with royal plastic paint as per instruction of Smt
engineer incharge. (N.S.)
Providing and laying 15mm bamboza wooden
flooring as per architect's drawing with all
necessary details as directed by the project
212 1.00 consultants. Use underlay for better result as per Detail Smt
specifications and directed by the project consultants.
(N.S.) (Approved Rate )
Varnishing two coats (excluding priming coat) on new wood
and wood based surface under coating with flatting varnish
and finished coat with varnish to give an even surface
213 10.00 including cleaning the surface of all dirt, dust and sand Smt
papering so as to
produce a smooth dry surface.
Finishing wall with weather proof exterior emulsion paint on
wall surface (two coats) to
214 2500.00 give an required shape evenshade after thoroughly brushing Sq.M.
the surface to remove all dirt, and remains of loose 113.40
powdered materials.etc complete
Providing and fixing flush door shutters, solid core
construction with frame of first class hardwood with cross
board and face veneer or plywood face panels, with
both side 1 mm laminate finishing including
anodized aluminum butt hinges with necessary
screws. Decorative type and pine wood core anodized
minimum 3 no 150 mm long aluminum butt hinges in
flush door shutters with 2 no of brass holdfast 325 mm
long 1 no brass tower bolt 250 mm long and two no of
mm long brass door handle . Decorative both side 4,686.36
laminated Flush door 35 mm thick. with frame of 10 cm
x 7 cmt Indian teak wood frame including all necessary
fitting fixtures hardware screw and adhesive etc fixing
up to all lead and lift height up to 45 mtr from GL etc
complete as per direction of engineer in charge
Providing and fixing 35mm thick factory made moulded door
shuter consisting of solid core single leaf flush door of 30mm
thickness, lipped with 15mm (5mm x 3) thick x 30mm width
on one stiles and top rail and 10mm (5mm x 2) thick x 30mm
width on the other stilesand bottom rails. The inner panel
laminated with 2mm thick termite proof, water proof and fire
resistant moulded PVC
216 1.00 sheet with 2,4,6 raised panel design in different plain and /or Smt
prelim colours on one side after routing the moulded design 2,131.00
on flush door and 2mm plain and/or prelim PVC sheet on
other side using rubber adhesive on flush door and solvent
cement adhesive on the PVC liping etc. complete as per
direction of Engineer in charge, manufacture’s specification
P/M/F chainlink jali 8'x4' size as per details sketch &
instructionof engineer in charge same as lal darwaja garden
pattern consisting of 3'dia. M.S black pipe 'A' class 5'4" ht.
fixed at 8'9" c/c in C.C 1:2:4 block of 9"x9"x9" size chain link
jali of size 2"x2"x10 gauge fixed in 35x35x5 mm MS angle
217 1.00 frame 8'x4' size with MS flat of size 25x3 mm welded jali Rmt
etc.comp.The jali is to be welded to MS pipe with MS flat as 1,230.00
instruction given.The M.S pipe and the M.S angle frame are
to be painted one coat of primer and two coats of paint as
directed in line and level. (N.S)
Providing & Fixing masonary wall with porbandar lachiya
stone with well dressed grooveas per directed by engg.in
charge for foundation, plinth or super structure level (above
plinth level upto floor two level) in cement mortar 1:5 (1-
218 cement : 5-fine sand) incl.pointing the joint with white
cement and yellow oxide powder in proportion to match
stone colour the joints should be thread grooved as per exi.
lake stone pitching apperance
(A) stone masonary wall/stone dressed single faced (size
(B) stone coping (size 15"x8"x4")
(C) stone coping (size 15"x8"x9")
(D) stone column (size 15"x15")
(E) stone column top (size 20"x20"x9")
Supplying and fixing of 300 mm-L x 150 mm-B x 380 mm-
H Kerb block for Footpath in M-20 grade using 20 mm
nominal size black trap aggregate of
Sevaliya/Timbaor equivalent quality for pre-cast
blocks, reasonablyexposed finish/ formwork
mould with well equippedwith vibratory system for
kerb stones of approved design including curing, etc.
complete, including thecost of formwork etc. complete.
The rate shall also include necessary cutting of
asphalt, fixing the Kerbstones in line and level on 5 cm
219 2.00 thick sand bedding withnecessary equipments
and materials. The rate shall also include the flush
pointing in CM (1:3) for all joints of thekerbstones. Filling of
zari alone the sides of the kerbstone fixed with
Bituminous concrete Bituminousconcrete / C.C.
mixed in proper position to flush withthe road surface
as directed by Engineer in change to form a
portable mixture.a) Laying on 5 cm thick Sand Bedding
Providing and fixing pre-cast concrete kerb stone of gray
cement based concrete block 30cm length,30cm height and
15cm thick of M200 grade concret as per approved design
220 5.00 and including excavation for fixing in proper line and Rmt
level,filling the joint with C:M 1:3 (1cement:3fine sand) etc
Providing and Laying of Rubber Moulded Paver Block
Grey/Coloured 60 mm thick, M-35 Grade of any size shape
(Usually Uni-Paver Blocks) using black trap good quality
aggragate of 20 mm nominal size for footpath,parking areas,
service lanes and other areas as mentioned in the drawing /
instruction of engineer in charge. Cost includes formworks
using rubber mould, Rate providing and laying paver blocks
as per required grading and specification. The paver block
shall be mechanically compacted. The work of paving blocks
shall be executed in line and level by skill mason of flooring
221 20.00 work only. It should be laid in such a way that the no cutting
of the paver block to be necessary. if cutting of paver block
necessary then it should be cut by machine only and carting.
The finished surface of the paver block shall have resonably
good, plain finished. Paver blocks shall be compacted and
shall be relaid if necessary. Gravel or such type of materials
shall not be allowed for production. Laying on 5 cms thick
Provoding and fixing flush door shutters, solid core
construction with frame of first class hard wood with cross
board and face veneer or ply wood face panels, including
anodised alluminium butt hinges with necessary screws. (B)
Non- decorative type and block board core anodised
222 1.00 alluminium butt hinges in flush door shutters (2) 35 mm
thick. Labour work for fixing any kind of paving with cement
pointing in CM 1:2, including watering, ramming etc comp.
as dir.For pavement
I) Laying on Sand bedding as per requirement to fix the
223 1.00 C.C.Block / Nibhada Stone in Line & Level Smt
Box type metal letters forming composite box made from
1mm thick stainless steel plate of grade 304 having brush
224 finish of following font size to be fixed at Main Gate in
english and or Gujrati and including fixing charges approved
before fixing by clent / consultant.
Providing and fixing false ceiling at all height including
providing and fixing of frame work made of special sections,
power pressed from M.S. sheets and galvanized with zinc
coating of 120 gms/sqm (both side inclusive) as per IS :
and consisting of angle cleats of size 25 mm wide x 1.6 mm
thick with flanges of 27 mm and 37mm, at 1200 mm centre
to centre, one flange fixed to the ceiling with dash fastener
12.5 mm dia x 50mm long with 6mm dia bolts, other flange
of cleat fixed to the angle hangers of 25x10x0.50 mm of
required length with nuts & bolts of required size and other
end of angle hanger fixed with intermediate G.I. channels
45x15x0.9 mm running at the spacing of 1200 mm centre to
centre, to which the ceiling section 0.5 mm thick bottom
wedge of 80 mm with tapered flanges of 26 mm each having
lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in
a direction perpendicular to G.I. intermediate channel with
connecting clips made out of 2.64 mm dia x 230 mm long
225 1.00 G.I. wire at every junction, including fixing perimeter Smt
channels 0.5 mm thick 27 mm high having flanges of 20 mm
and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugs at 450 mm centre,
with 25mm long dry wall screws @ 230 mm interval,
including fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall screws of size
x 25 mm at 230 mm c/c, including jointing and finishing to a
flush finish of tapered and square edges of the board with
recomme-nded jointing compound , jointing tapes , finishing
with jointing compound in 3 layers covering upto 150 mm on
both sides of joint and two coats of primer suitable for board,
all as per manufacturer’s specification and also including the
cost of making openings for light fittings, grills, diffusers,
cutouts made with frame of perimeter channels suitably
fixed, all complete as per drawings, specification and
direction of the Engineer in Charge but excluding the cost of
Providing and fixing wall acoustical paneling using ecotone
Slato/ Anutone slato or equivalent Acoustic Panel make
Slats L-16 of size 128mmx2430mmx16mm thick up to
2400mm high as per the following specification :-Slats L-16-
2mm @16mm, 32 x 128 x 2430 mm high grade Pine wood
base Medium Density Fiber acoustic boards with Tongue &
Groove Edge,2mm slot perforation @ 16mm centre, slates
perforations, The acoustic should be furnished with a Black
absorbent felt backing with an airflow resistance of 330-
Ns/m³ (DIN 53887),wood practical core,NRC : should be Up
226 1.00 to 0.75,should meet the safety requirements of EN 14190. Sq.mt.
Fixing :- Sound Strut CC18 screw fixed horizontal/vertical to 4,160.00
wall at every 600mm c/c. Metal cleat can be fixed on top
edges of Sound Strut CS55 fixed directly by stamping to the
CS55 and IC91 which is screw fixed directly to the wall
where ever required with a backing black color fabric as
approved by Architect and as specified including all
accessories, material & labor complete as directed by
Architect / Engineer.
Providing & Fixing SPEED BUMP - #2 No (1 black, 1 yellow)
350 x 500 x 50 mm, Size per color End Cape 350 MM x
MM x 50 MM TOP DESIGN - Lining Top flat ANTI SKID
PATTERN FOR GRIP COLOUR :- YELLOW & BLACK
BODY MATERIAL :- MODIFIED THERMOPLASTICS
227 1.00 (Polymer Rubberized ) • ECO FRIENDLY RECYCLE Rmt.
RUBBER Packing :- 4 pcs/ woven Bag Load Capacity :- 20 2,185.00
MT Fitting ( Fixing on TRAKE) :-4 holes & END CAPE :-
HOLE HEX Bolts with Washer Epoxy for Bolt Fitting etc.
complete as directed by EIC .
Providing & Fixing in position 24 MM exposed grid
suspension system with “P “ Grid profile false ceiling system
using 600 MM X 600 MM ecotone/anutone or equivalent
make Glass Fiber Ceiling Tiles having tegular edges &
NRC value and approved surface design (with NRC of 0.90)
and edge profile Tegular placed in a suspended grid of size
600 MM X 600 MM made from hot dipped GI Steel sections,
rotary stitched, main tee of size 24 X 42 X 3000 MM X
MM thickness suspended at every 600 MM c/c along length
228 1.00 of ceiling with 4 MM dia, Pre-straightened G.I.Wire with Sq.mt.
necessary level adjusters & intermediate cross tees of size
24 X 38 X 600 MM X 0.40 MM thickness shall be inserted in
to slots between the main tees at 600 MM centers in
direction vertical to the main tees, where in the main tees
are resting on the periphery on wall angles of size 24 MM X
24 MM X 3000 MM X 0.40 MM thickness including providing
necessary openings for light fixtures, diffusers etc.
Providing and applying Texture Paint (Rustic Finish) on
external plastered surfaces, pattern as per sample approved
by the Architect. including preparing surface, using roller to
get approved texturised surface. Job to include making
required surface preparation, to receive Texture paint finish
229 300.00 etc. All complete as per detail drawing, as specified and as Sq.m
directed by Architect / Consultant / Project - In - Charge. The 425.00
rates shall be inclusive of Scaffolding, all material, labour
etc. complete. as directed by EIC.
Providing and fixing PVC/Gpsysum plain colour false
ceiling with grid type with aluminium frame from
gypsteel, fastners ,props, Finishing as per architectural
drawing allowing openings for A.C. Diffusers,
Light/Electrical Points etc –complete, Prior to fixing on 766.00
frame.(Brand : Anutone or equivalent ) (N.S.) or as
directd by engineer In Charge.
Provdg. & laying S.W. Gully trap with brick masonry
231 1.00 chamber & water tight G.T.Stone including fixing of No.
covervSquare mouth trap 100 mm x100 mm size P-Trap 1,279.40
Providing and laying (to level or slopes) and jointing with stiff
mixture of Cement Mortar in proportion 1:1 Salt glazed
232 1.00 stoneware pipes including testing of pipes and joints Rmt.
complete.(A) 100mm dia.
Providing and laying (to level or slopes) and jointing with stiff
mixture of Cement Mortar in proportion 1:1 Salt glazed
233 1.00 stoneware pipes including testing of pipes and joints Rmt.
complete.(B) 150mm dia.
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe
234 1.00 with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone Each
aggregate 20mm size) foundation concrete 1:5:10 inside 2,903.89
plaster 15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed
concrete etc. complete.(i) Inside dimensions 455mmx
610mm and 450mm deep for single pipe line.
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg/Cm2 in C.M. 1:5 C.I. cover with
frame (Light duty) 455mm x 610mm intenal dimensions total
weight of cover with frame to be not less than 38Kg. (Wt. of
cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C. top slabe
with 1:2:4 mix (1-cement :2- coarse sand :4-graded stone
235 1.00 aggregate 20mm size) foundation concrete 1:5:10 inside Each
plaster 15mm thick with cement mortar 1:3 finished smooth
with a floating coat of neat cement on walls and bed
concrete etc. complete.(i)Inside dimensions 500mm x
mm and 450mm deep for pipe line
with one or two inlets.
Constructing brick masonry chamber for underground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than
35Kg/ Cm2 in C.M. 1:5 C.I. cover with frame (Light duty)
455mm x 610mm intenal dimensions total weight of cover
with frame to be not less than
38Kg. (Wt. of cover 23 Kg.) and Wt. of frame 15Kg. ) (R.C.C.
236 1.00 top slabe with 1:2:4 mix (1-cement :2- coarse sand :4- Each
graded stone aggregate 20mm size) 7,109.35
foundation concrete 1:5:10 inside plaster 15mm thick with
cement mortar 1:3 finished smooth with a floating coat of
neat cement on walls and bed
concrete etc. complete.(iii) Inside dimensions 600mm x
mm and 450mm deep for pipe lines with three or more inlets.
Providing, supplying and fixing precast C.C. blocks (M-20)
edge kerb having size of 75 x 300 x 300 mm depth and as
237 2.00 per design conveying it to the site, jointing into C:M 1:3 and Rmt.
racking out the joints incl. necessary excavation of asphalt, 219.00
soil etc..completed.
Constructing a cooking Sandwich platform 60 cm. width and
70 cm high resting on B.B.Masonry walls
238 3.00 23 cm.thick in C.M.(1:6) with (ii) Fixing black Granitee 30mm Rmt.
thick laid on precast R.C.C. (1:2:4) slab with plastering on 933.98
exposed faces of wall in C.M. (1:4) etc complete.
Constructing a cooking platform 60 cm. width and 70 cm
high resting on B.B.Masonry walls 23 cm.thick in C.M.(1:6)
239 2.00 with (ii) Fixing black kadappa stone 30mm thick laid on Rmt
precast R.C.C. (1:2:4)slab with plastering on exposed faces 1,132.43
of wall in C.M. (1:4) etc complete.
Providing and fixing hard drawn steel wire fabric 75mm x
25mm mesh or weight not less than 7.75 kg. per Sq.M. to
240 2.00 window frames etc. including60 x 20mm beading of teak Smt
Providing & fixing 15 cm wide chicken mesh jali with nails &
241 2.00 then application of 15 mm plaster on R.C.C.& masonary Rmt.
joints as per dir.of engg.in charge 35.00
Providing and laying cement concrete flooring 1:2:4 (1-
cement : 2-coarse sand : 4-graded stone aggregate 20mm
242 2.00 nominal size) laid in one layer and finished with a floating
coat of neat cement. (A) 50mm thick.
Providing and constructing, Underground (U/G) water tank of
specified capacity, on specified location, for all depths, in
controlled CC of M-200 grade with bottom slab, top slab and
RCC walls, including cost of form work and
reinforcement,with inside and outside plaster in CM 1 :3 and
243 1000.00 water proofing treatment as per IWP specification,including
injection, grouting, etc. complete. The rate includes for
providing and fixing two nos. 0.6m. x 0.6 m. size medium
duty CI manhole cover/s at top, including wash out pipe line
and inlet and outlet connections etc. complete.
Providing and fixing PVC Printed pain colour false ceiling
with grid type with alluminium frame consisting of 600mm x
600mm 3mm thick plain PVC sheet used as panel insert in a
frame work made using anodized alluminium T section of
size 1 x 1 (235 x 25mm, 19 gauge or 1 mm thick) in square
pattern of grid sizes of 2 x 2 (600 x 600mm) The alluminium
frame work is supported from the cceiling with the help of
244 2.00 G.I. hook and G.I. wire/6mm M.S. rods of required sizes to
maintain proper level etc. The aluminium frame work is
supported on side wall with the use of alluminium L section
of size 1 x1 (25 x 25mm) angles etc. complete as per
direction of Engineer in charge. Manufactures specification
Providing and supplying of labour for necessary manual
excavation, cleaning, Shifting of Material Or any other, or for
245 20.00 any other work as directed by Engineer In charge. The Rate
includes Handcart with Mazdoor
Fitter/Plumber/Mason
WELDER/ Gas cutter at Day /night
Supplting of welding machine / gas cutter including cost of
D 2.00 welding rods/gas, Transportation, including carting from site No
to work place. 1,500.00
Mazdoor at Day Male/Female
Providing and fixing wooden planks ceiling with tounged and
grooved jointing and wood screws (frame work and cover
246 2.00 fillings to be measured and
laid for separately) (A) Indian Teak wood (ii) 20mm thick
Supplying electric breaker machine for RCC slab or asphalt
demolishing work on site by using operator, fuel, power
supply etc.complete as directed. (no payment should be
247 2.00 allowed for non working condition of machinery and for pipe
line excavation and M.H. work. Allowed only for break down
work) (Based on Previously approved rate by CE sir )
CatchPit Jali Fixing P/F FRC catch pit jali with frame 600mm
248 1.00 x 600mm clear opening etc. comp. As directed by engineer No.
in charge. (Based on Central Store Rate) 1,383.92
Providing and fixing concealed center point to wall ceiling &
floor CPVC (SDR 13.5) PIPE having National Sanitation
249 Foundation (NSF) seal for potable water of following dia.
nominal bore tube fittings and clamps including making good
the wall, ceiling and floor etc. complete.
Providing and fixing cast iron steps of size 500mm x 150mm
250 2.00 x 22.5mm and painting with two coats of Anti-corrosive paint Each
etc. complete. 162.23
Supplying and fixing C.I. cover 300mm x 300mm without
251 2.00 frame for Gulley trap (Standard pattern) te weight of cover to Each
be not less 4.53 Kg.) 491.80
Providing and fixing to wall ceiling and floor
10.0Kg.F/Cm2 working pressure polythene pipes of the
following out side Dia. Low densidy, complete
252 with special falnge compression type fittings, wall
clips etc. including making good the wall ceiling and
Providing and fixing sheet glass, selected quality (Type-C)
bedded in putty and fixed with
253 2.00 wooden beading including the cost of wooden beadings of Smt
first class teakwood and necessary cutting of glass. (2) 6 1,176.10
Providing and fixing rough cast wired glass, 6mm thick
bedded in putty and fixed with
254 2.00 wooden beading including the cost of wooden beadings of Smt
Indian teak wood and necessary cutting of glass. (C) Wired - 559.26
Filling cement concrete 1:2:4 (1- Cement :2-coarse sand :4-
graded stone aggregate 12.5 mm nominal size) in gaps of
255 20.00 A.C. sheet corrugation and wings of
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse
sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1- Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size)
finished smooth complete including curing and festing (i)
256 1.00 Inside size 900mm x 1200mm
and 1.5M. deep including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be not less than
128 kgs. (Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A)
With 230mm thick walls of brick msonry using brick having
crushing strength not less than 35Kg. / Sq.cm. in Cement
Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth
Metre for 150mm diameter sewer.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-
cement :2-coarse sand : 4-graded stone aggregate 20mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand :6-Brick bats 40 + 50mm size) inside plastering
15mm thick with Cement Mortar 1:3 (1-Cement : 3-coarse
sand) finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1- Cement
:2-Coarse sand :4-stone aggregate 20mm nominal size)
257 1.00 finished smooth complete including curing and festing (i)
Inside size 900mm x 1200mm and 1.5M. deep including C.I.
cover with frame size 560mm diameter total weight of cover
and frame to be not less than 128 kgs. (Wt. of cover 64 Kg.
and Wt. of frame 64 Kg.)(A) With 230mm thick walls of brick
msonry using brick having crushing strength not less than
35Kg. / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse
sand) (2) B type depth 1.50 Metre for 150mm diameter
Providing laying (to level or slopes) and jointing reinforced
concrete Light duty non-pressure pipes I.S. class NP2 of the
258 1.00 following internal diameter with Rmt
collars and butt ends prepared for collar joints including 658.89
testing of joints complete.(D) 300mm
Pro. And fixing single layer water proof gypsum board
mm thick sections using water proof board of size 1220 mm
x 1830 mm x 8.0 mm suspended by GI suspender channel
of size 25 mm x 3 mm with intermediate channel og size
mm x 40 mm x 0.8 mm at 1220 mm center to center ceiling
section of size 40 mm x 35 mm x 0.55 mm at
457 mm c/c and perimeter channel A of size 20 mm x
259 1.00 mm x 30 mm x 0.5 mm at edges & drops incl.paper tap sand
sofit cleat, anchor fastener,
scoch bolt connecting cleat,joining compound top coat on
ceiling incl.making necy.opening for light fitting,diffuser etc.
comp. as per detail drawing as
Providing & Fixing PVC Body Chromium Finish Health
Faucet with Flexible Pipe of Approved Brand &
260 15.00 Manufactures with holder etc.complete as per direction of
engg. in charge.
Providing and operation dewatering Pump including
fuel charges & operator Charges etc. as directed etc.
261 2.00 comp. (Shift for Eight Hour) (For Each Pump Set, No Shift
payment should be allowed for non working condition of 535.71
machinery) (Based on Previously approved rate by C E sir )
Providing in line level plumb, fabricating and fixing three
row horizontal barbed wire fencing and punched tape
concertina coil of 9 turns per meter of 610 mm dia fixed with
clips on top of the angle iron posts. The punched tape
concertina coil having sharp barbs at every 25 mm spacing
shall be 0.5 mm thick and 19 mm width and weighting
262 5.00 kg/100 mt. (Average) as per manufacture's specification. Rmt
The rate shall also include providing and fixing 1.20 390.00
mt.total long MS angle 40 x 40 x 6 mm @3.00 mt.c/c
spacing embaded in RCC column, angle posts shall be
painted with one coats of red oxide and two coats of enamel
paint of approved quality at top compound wall.
Providing, laying, spreading and compacting graded stone
aggregate to wet mix macadam specification including
premixing the Material with water at OMC in mechanical mix
plant carriage of mixed Material by tipper to site, laying in
uniform layers in subbase / base course on well prepared
surface and compacting with vibratory roller to achieve the
desired density as per MoRTH clause
(A) Supply of WMM
(B) Laying of WMM
Labour work for fixing interlocking blocks / any kind of
pavement on up to 50 mm th sand bedding, levelling,
264 20.00 watering and fixing in line & level as well cleaning the Smt
site etc.comp. as directed.SOR - (Jan. -2016) for Central 78.00
Verge / Footpath / Stone Paving
Paver Block Providing and laying shot blasted Non -
interlocking, Paver blocks of specified thickness, size, grade
of concrete and colour machine made and blasting by
automatic shot blasting machine and high density of as per
approved sample of approved make for footpath, parking
areas, service lanes,cross over and other areas as
mentioned in the drawing. Including providing and laying
mm thick averave bedding layer of coarse sand below paver
block as per required grading and specification. Laid paver
block shall be mechanically compacted. The work of the
paving blocks shall be executed in line and level by skilled
265 20.00 mason of flooring work only. Small size of paver block with
same specification shall be used at residue or at end. It
should be laid in such a way that the no cutting of the paver
block to be necessary. If cutting of paver block shall be
required , than cut by machine only and laying to be done by
skilled flooring mason. The finished surface of the paver
block shall have coarse sand Texture Finish. Pave blocks
shall be compacted and shall be re-laid if necessary. Actual
laid area shall be measured and paid without any wastage.
(A) 60 mm thick M-35 grade Grey Paver block of size
Lettering and lettering charges and printing Muni.corporation
266 3.00 symbol with help or skilled artist including colour costst. No
Prismatic grade reflective sheeting with super high
performance durable ,micro prismatic material confirming to
type XI as per ASTM-D 4956 -09 & Cutting , pesting letter
267 3.00 according to IRC standard in dual language with micro
prismatic material confirming to type XIsmatic confirming to
Excavation of pit of manually necessary labour of size
.6*.6*.6 m for as per above MS Structure foundation of pole
for any size. The grade of concrete should be M-20 the item
268 5.00 rate include carting, filling, with available earth and should
be proper be level up to ngl,as directed by Engineer in
Providing and supplying ISI marked only standard length
Stonewate pipes in standard lengths of following
class and diameter including all taxes,insurance,
transportiton, fright charges, octroi,inspection
269 charges, loading, unloading, conveyance to
departmental stores, stacking etc. complete (IS -
(GWSSB SOR 2021-22)
Lowering, laying and jointing stone ware pipes of
following diameters with cement joints in C.M.1:1
proportion in proper position , grade and alignment at all
270 level as directed by Engineer-in- charge including
conveyance from stone to site of work,Jointing material
etc.comp.(GWSSB SOR 2021-22)
Constructing Chamber of following size including
excavation, refilling, BBCC (1:5:10) for foundation,
C.C.Channel (1:2:4), finished 15 mm thick cement plaster
inside in CM 1:3, finishing with cement slurry, Brick
masonary in CM 1:5 & excluding the cost of chamber
seat cover etc..completed. (Based on Drainage SOR 2009-
0.60 X 0.45 mt. size Inside Clear, Depth from 0.0 to
2.00 0.90meter for pipe dia <=150 mm.
0.60 X 0.75 mt. size Inside Clear, Depth from 0.0 to
2.00 0.90meter for pipe dia <=20 mm.
0.75 X 0.75 mt. size (Inside Clear) Depth from 0.0 to
2.00 meter for pipe dia <=20 mm
Constructing Slab Type M.H. Chamber Of The
Following Size Including Excavation, Refilling, Brick Bats
Cement Concrete (1:5:10) of thickness 15 C.M., CC
Channel (1:2:4) of thickness 10 C.M., finished 15 mm
thick cement plaster inside & outside (Only for shaft)
In Cm 1:3, Finishing With Cement Slurry, P/F 4 Mm
Dia M.S.Steel Hdpe Coated Steps 35 Cm C/C At
272 Cm Staggered Masonary In Cm 1:5, Rcc Slab In
Cc1:1.5:3 of thickness 15 C.M.,Including
Cantering & Reinforcement (Single jalli at 15 C.M. c/c
bothway 10 mm dia.)But Excluding The Cost Of
Manhole Seat Cover Etc..Completed Of Size 0.75 X
1.00 Meter (Inside Clear, M.H. length should be parallel to
the flow) (Based on Drainage SOR 2009-10)
1.00 to 2.00 meter depth, (Slab at Ground level) (for
2.00 pipe dia <=230 mm)
2.00 to 3.00 meter depth, (Slab at below 0.60 mt. From
2.00 G.L.) (for pipe dia <=300 mm)
Making connection to the ex. M.H.in running sewer
incl. Dewatering and other required machinery etc.
273 of following dia pipes at any convenient time. All
damaged work shall be well repaired as per instructions.
etc..complete. (Based on Drainage SOR 2009-10)
a. 150 mm to 300 mm dia.
b. 400 mm to 600 mm dia.
Repairing damaged M.H. and rasing M.H. up to road
level incl. removing damaged brick work and repairing
by brick masonry in C.M. 1:5 and plaster in C.M. 1:3 and
274 fixing C.I. steps and existing MH sheet cover, removing
the debris from MH and carting the same as
directed. (Based on
Drainage SOR 2009-10)
(A) up to 0.15 mt. (@ Two Coarse)
(B) up to 0.35mt. (@ Four Coarse)
RCC Precast M.H.Frame & Cover Manufacture , supply
& Delivery at store or at side of work Precast RCC
M200 Frame & Cover Suitable to drainage M.H. and as
275 per type design & Drawing including cost of reinforcement
M.S. Angles or Flat , cutting mold work etc.(GWSSB SOR
Heavy Duty No. -
Frame Suitable for 50 Cm opening of MH
Cover Suitable for 50Cm Opening Of MH
Light Duty No. -
Frame Suitable for 50 Cm opening of MH
Cover Suitable for 50Cm Opening Of MH
House connection Chamber Light Duty No. -
Providing , supplying & Laying ISI marked only standard
length PVC FORMCOR pipes in standard lengths of
following class and diameter including all
taxes,insurance, transportiton, fright charges,
276 2.00 octroi,inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc.
complete ( S-N-4) (1) 200 mm dia.
Renovation and Repairing work in Chainlink fencing any
size and also refixing work incl. febrication work with all
277 5.00 materails to be painted one coat of primer and twocoats of
paint as directed inline and level. (N.S.)
Providing & Fixing Stair / Balcony Railing as per Consultant's
Design from M.S.square Rectangular,Round pipe of required
Dia, M.S.Flat,Angle,channel & other sections of required
size as per detail work includes
cutting,bending,welding,grinding,Fixing with necessary
supports - holdfasts,Application of one coat of Zinc
Primer,Two coats of Oil Painting etc.complete.(N.S.)
Finishing wall with Apex Ultima Acrylic paint of " Asian
Paint " or equivalent on wall surfaces (two coats) to
279 10000.00 give required even shade after application of Exterior Smt
Primer of Approved Brand & Manufactures after 79.00
thoroughly brushing the surface to remove a
Seal and Signature of the Bidder Add City Engineer
Date: (West Zone)
AHMEDABAD MUNICIPAL CORPORATION
West Zone, Zonal Office", 2nd Floor, A.M. Office, Dr. Ramanbhai Patel Bhavan, Usmanpura,
Ahmedabad Municipal Corporation, W.Z. Office, Ahmedabad-380013.
Municipal Commissioner invites Percentage Rate sealed tenders from interested
MEMORANDUM OF WORKS IN BRIEF
1 Name of work Repairing/Renovation and Colour Work at Diff.Muni.
Buildings of Naranpura ward in west zone.
2 Time Limit 12 Months
3 Tender Validity Period 120 Days from the date of opening of the tender
4 Eligibility Criteria Register “D” class in PWD in Govt. R&B/CPWD/AMC or equivalent
registration with any other state Govt. or institutions.
5 Estimated Cost put to Rs.
6 Earnest Money Deposit Rs.58500/- (Demand Draft or pay order in favour of Municipal Commissioner,
Ahmedabad /) To be submitted as below. Demand Draft or Bank Guarantee shall be
from Nationalized Bank / Sheduled Bank and valid for 120 days. (As per Latest AMC
finance dept.circular).
7 Security Deposit 5 % of the Sanctioned Tender Amount in form of Bank Guarantee/
Demand Draft / Local MICR Cheque. & attched ANNEXURE - 1 finance
dept.circular No- 14 Dt.4/6/13
8 Tender fees Rs.2400/-Demand Draft in favour of Municipal Commissioner,
(Non refundable) Ahmedabad)
9 Submission of EMD and In separate sealed cover each for EMD and Tender Fees along with
Tender Fees Tender as described in the invitation of tender and submitted to Assistant
Manager (west zone),Ahmedabad Municipal Corporation, West Zone,
Zonal Office", Dr. Ramanbhai Patel Bhavan, Usmanpura, Ahmedabad.
10 Tenders issue date Tenders from the AMC website www.amc.nprocure.com &
www.nprocure.com shall be down loaded from AS PER TENDER NOTICE
11 Last Date of Submission Dt.30-04-2026 upto 18:00 hrs As per Notice inviting Tender / Addendum
of the / Corrigendum.. The tenders received after latest schedule date and time
Tender will not be entertained under any circumstances.
12 Tender Documents Dt.01-05-2026 upto 12:00 hrs to Assistant Manager / Add.C.E.(W/Z) office,
Submission 2nd Floor, Dr. Ramanbhai Patel Bhavan,Usmanpura, Ahmedabad
Municipal Corporation, W.Z. Office, Ahmedabad-380013
13 Date of Opening Dt.01-05-2026 upto 15:00 hrs As per Notice inviting Tender / Addendum
/ Corrigendum (only Techanical Bid) to Assistant Manager /
Add.C.E.(W/Z) office, 2nd Floor, Dr. Ramanbhai Patel
Bhavan,Usmanpura, Ahmedabad Municipal Corporation, W.Z. Office,
Ahmedabad-380013
14 Mode of sending the Document shall be physically submitted in sealed envelope By
Tender Documents and RPAD/Speed post/ Hand Delivery in sealed covers in Duplicate (One
evalution of tender Original & One Duplicate) duly sign & seal by contractor
Tenders received without EMD shall be considered as Non-Responsive and
shall be rejected outright.
15 Terms, Condition, & All general condition of contract of Form B1 condition of contract shall
Specification be applicable..
16 Defect &Liability Period The contractor shall be responsible to make good and remedy at his own expense
any defect which may develop or may be noticed before the period mentioned
hereunder from the certified date of completion, The within 15 days of receipt of
the notice. In the case of failure on the part of the contractor, the Engineer-in-
charge may rectify or remove or re-execute the work at the risk & cost of the
contractor. The Engineer-in-charge shall be entitled to appropriate the whole or
any part of the amount of security deposit towards the expenses, if any, Incurred
by him in rectification, removal or re-execution. The Defects Liability period
shall be as under(a) for all works costing upto Rs. 50,000 ( amount put to
tender), the period shall be 3 months from the certified date of completion.
(b) for all works costing more than Rs. 50,000 and upto Rs. 1 crore (amount put
tender), the period shall be 6 months from the certified date of completion or one
monsoon, whichever is later.
(c) for major projects costing more than Rs. 1 crore, the period shall be
months from the certified date of completion which should include one
(d) For building works, the period specified in (a), (b) or (c) above OR elapse of
monsoon period following the certified date of completion, whichever is later.
For the purpose of deciding the monsoon period, the 30th September may be
treated as the last date.
17 Time permitted to start Whenever a work is allotted by Engineering staff, whether minor or major
parts of work of part thereof of any amount, the contractor shall be bound to start the
works within 48 hours of intimation of work. Communication done
telephonically via Calls,SMS, Via Whatsapp and through letter / E-mail
shall be considered legal and binding for the same. Failure of comply to
start the works in 48 hours of intimation as above by contractor the
contractor shall be levied penalty of (1) Rs.1000/- per day (for tenders
amounting upto 10 Lakhs), (2) Rs.2500 per day (for tenders amounting
above 10 Lakhs and upto 30 Lakhs), (3) Rs.5000 per day (for all tenders
amounting above 30 Lakhs). Three times failures by contractor shall make
contractor responsible to be black listed unless and otherwise justified
properly in writing / binding within 15 days of last notice of penalty.
18 Compensation for Delay 10% of Remaining work (As per Circular)
19 Addendum/Corrigendum Addendum/Corrigendum If any Shall be Published 48 Hrs. Price To the
Final Submission Time And Date. The Same Shall From a part Of Tender
And The Same As to be Attached Along With The Tender Document.
20 EPF Act As per Acoount Department circular no-37 Date:09/08/2018
21 GST 18% GST will be paid extra by AMC/Authority at prevailing rate to the
22 Municipal Commissioner reserves the rights to reject any or all the tenders without assigning any
reasons thereof.
23 Conditional tenders will not be accepted.
24 Mobilization advance will not be given.
25 Contractor has to provide more than one number of gangs as per the works allotted and in case of non
providing of gangs and machinery at all sites at given time shall be treated as delayed by contractor
and penalty shall be levied on per day delay as mentioned as above.(the amounr shall be as instructed
earlier based on the tender amount)
26 The staff of the contractor shall wear safety jackets,hoes, helmets etc. while on duty and any violation
will attractfineofRs. 5,000/-foreach incident. Failure to erect safety signage or trying to carry out the
works with out proper precautions/safety measures as required will attract a fine of Rs.5,000/-for each
27 The contractor shall adhere to the maintenance schedule outlined in the tender documents and comply
with the prevailing AMC circulars issued from time to time.
Seal and Signature of the Bidder Add. City Engineer
AMC Finance dept. circular No – 41, Dt.08/02/2022
(A) Guarantees issued by following banks will be accepted as SD/EMD on permanent basis.
(1) All Nationalized Banks
(B) Guarantees issued by following banks will be accepted as SD/EMD for the period up to March-
2022. The validity cut-off date in the GR is with respect to the date of issue of Bank Guarantee irrespective
of the date of termination of Bank Guarantee. Guarantees issued or Authorized by Ahmedabad Branch Only.
(1) Commercial Banks:
(3) ICICI Bank.
(5) Kotak Mahindra Bank
(6) IndudInd bank
(8) Tamilnadu Mercantile Bank
(9) Ujjivan Small Finance bank
(10) A U Small Finance Bank
(11) Fedaral Bank Bank
(12) Equitas Small Finance bank
(13) Bandhan Bank
(14) Standard Chartered Bank
(2) Co-Operative & Rural Banks of Gujarat
1. The Mehsana Urban Co-operative Bank Ltd
2. The Ahmedabad Mercantile Co-Operative Bank Ltd
3. Nutan nagrik Sahakari Bank Ltd
4. The Kalupur Commerical Co-operative Bank Ltd
5. Rajkot Nagarik Sahakari Bank Limited
6. The Gujarat State Co-Operative Bank
7. Sarswat Bank
8. Saurashtra Gramin Bank
Seal and Signature of the Bidder Add.City Engineer
AHMEDABAD MUNICIPAL CORPORATION
Invitation for Bid (IFB)
1. The AHMEDABAD MUNICIPAL CORPORATION, (hereinafter called “the Employer”) invites
sealed Tender document from reputed and qualified bidders for the construction of Works detailed in
the Table below:-
Sr. Name of Works Approximate Earnest Completion
No value of works Money Period
. (Rs.) Deposit
1 Repairing/Renovation Rs. 58,32,794.93 Rs.58,500/- 12 Months
and Colour Work at
Diff.Muni. Buildings of
Naranpura ward in west
2. Interested bidders shall download the tender documents from AMC’s website
www. amcnprocure.com/ www.nprocure.com.
3. Tender (a complete set of bidding document) fee shall be Rs. 2400.00 in the form of Demand Draft /
Pay Order from any Nationalised Bank in favour of MUNICIPAL COMMISSIONER, Ahmedabad,
payable at Ahmedabad, which shall be non refundable.
4. All bids must be accompanied by Earnest Money Deposit of the amount specified for the Works in
the above Table payable at Ahmedabad and drawn in favour of MUNICIPAL COMMISSIONER,
Ahmedabad, payable at Ahmedabad,. Earnest Money Deposit will have to be specified in Clause 2 of
Financial Condition.
5. Physical submission must be delivered to Asst. Manager (Admin) West Zone, 2nd Floor,Dr.
Ramanbhai Patel Bhavan, Usmanpura, Ahmedabad Municipal Corporation, W.Z. Office,
Ahmedabad-380013.
6. The Bids will be opened at the office of Addl.City Engineer (W/Z) , Ahmedabad Municipal
Corporation, 2nd Floor, Dr. Ramanbhai Patel Bhavan, Usmanpura, Ahmedabad Municipal
Corporation, W.Z. Office, Ahmedabad-380013. in the presence of bidders or their representatives
who choose to attend. In the event of the specified date of bid submission/opening being declared a
holiday for the Employer, the bids shall be received /opened on the next working day at the same
place and the same time.
TERMS & CONDITIONS
( A ) INSTRUCTIONS TO BIDDERS (ITB)
( B ) GENERAL TERMS & CONDITIONS
( C ) FINACIAL TERMS & CONDITIONS
( D ) MAIN CONDITION / FETURES OF THE WORK
AHMEDABAD MUNICIPAL CORPORATION
TERMS & CONDITION
( A ) INSTRUCTIONS TO BIDDERS (ITB)
1. Procedure for Submission of Tender
a). The Bidder should quote the price bid in tender form before schedule time Tender Document, tender fee &
EMD (Draft /DD) and all other enclosures as asked in tender.
b).The bidder shall submit the following Tender documents physically in hard copy in two separate envelope
(marked as “original” and other marked as “Duplicate”) in schedule time by RPAD/ Speed Post/ Hand
Delivery in duplicate. The Bid envelopes shall be marked as follows:-
Tender Document
Registration certificate of class
c).The envelope shall be addressed to the Employer at the following address:
Asst. Manager (Admin) West Zone,
2nd Floor,Dr. Ramanbhai Patel Bhavan,
Usmanpura, Ahmedabad Municipal Corporation,
W.Z. Office, Ahmedabad-380013
d).Bear the following identification:
“TO BE OPENED ONLY IN PRESENCE OF THE EVALUATION COMMITTEE”
e). Indicate the name and address of the bidder.
If the outer envelope is not sealed and marked as above, the Employer will assume no responsibility for
the misplacement or premature opening of the bid.
f).All information has to be typed or hand written legibly. All pages of the Bid have to be initialed by the
g) All The Bid Document Essentially Needs to be Properly binded/steppled
2. Assessment of Submission
2.1 The Employer will open the technical bid of physically submitted document of all the bids received for
the package (except those received late) containing the sealed Tender volume and other enclosures then
announce the names of bidders in the presence of bidders or their representatives who choose to attend
on the date and time mentioned in the NIT In the event of specified date of bid opening being declared as
a holiday for the Employer, the Tender will be opened at the appointed time and location on the next
2.2 In Physical submission, Bidders detailed and tender fee, E.M.D. shall be opened first. The Employer at
the opening will announce bidder’s names, , the presence/or absence of EMD, the amount and validity of
EMD furnished with each bid, is valid registration and such other details, as the Employer may consider
2.3 The Employer will determine whether the bid is accompanied by the required EMD.
2.4 If the EMD furnished does not conform to the amount and validity period as specified in the Invitation
for Bid and has not been furnished in the form, the bid shall be rejected by the Employer as non-
responsive and the Tender volume will be returned to the bidder.
2.5 Subject to confirmation of the EMD by the issuing bank, the Tender volume accompanied with valid
EMD will be taken up for further evaluation. In case, the Bank does not confirm the EMD, the bid shall
be rejected as non-responsive and no further evaluation carried out.
2.6 The tender volume will further be examined to determine whether the bid has been properly signed,
meets the eligibility and qualification criteria, has the required available bid capacity, is accompanied by
the requisite certificates, undertaking and other relevant information specified in the bid documents and
is substantially responsive to the requirement of the bidding documents and provides any clarification for
ascertaining the correctness of the information/details.
2.7 If the Tender volume is not substantially responsive, it will be rejected by the Employer and will not
subsequently be made responsive by correction or modification or withdrawal of the nonconforming
deviation or reservation.
3. Evaluation and Comparison of Tender volume
The Employer will evaluate and compare only those Tender volumes which are determined to be
substantially responsive in accordance with Clause 2 and qualified for award of Contract in accordance
with Clause 5 (General Terms and Condition).
4. Procedure for Tender Opening
Received copies of tender in physical form with in schedule time, will be open on schedule date and
time. In the event of specified date of bid opening being declared bidders who qualify the criteria then
bidder bid will be considered for opening of price bid.
5.1 The Employer will award the Contract to the bidder whose bid has been determined to be substantially
responsive to the bidding documents and who has offered the lowest Evaluated Bid Price, provided that
such bidder has been determined to be (i) eligible in accordance with the provisions of Clause 3(General
Terms and Condition); and (ii) qualified in accordance with the provisions of Clause 5(General Terms
and Condition).
6. Notification of Award
6.1 Prior to expiration of the period of bid validity prescribed by the Employer, the Employer will notify the
successful bidder by cable/fax and confirmed by registered letter that his bid has been accepted. This
letter shall name the sum which the Employer will pay the Contractor in consideration of the execution,
completion and maintenance of the Works by the Contractor as prescribed by the Contract.
6.2 The notification of award will constitute the formation of the Contract.
7. A successful Bidder has to deposit security deposit / Bank Guarantee as per Circular after receiving letter
of Indent. Time limit of work will commence from the date of issue of work order.
8. Clarification of Bids
8.1 To assist in the examination, evaluation and comparison of bids, the Employer may, at his discretion, ask
any bidder for authentication the correctness of the information/details furnished by him in his bid. Such
request by the Employer and the response by bidder shall be in writing or by cable/fax.
8.2 Subject to above clause, no bidders shall contact the Employer on any matter relating to his bid from the
time of bid opening to the time contract is awarded.
8.3 Any effort by the bidder to influence the Employer in the Employer’s bid evaluation, bid comparison or
contract award decisions may result in the rejection of his bid.
9.1 Information relating to the examination, clarification, evaluation and comparison of bids and
recommendations for the award of a contract shall not be disclosed to bidders or any other persons not
officially concerned with such process until the award to the successful bidder has been announced. Any
effort by a bidder to influence the Employer's processing of bids or award decisions may result in the
rejection of his bid.
10.1 The bidder is advised to visit and examine the Site of Works and its surroundings and obtain for itself
on its own responsibility all information that may be necessary for preparing the bid and entering into a
contract for construction of the Works. The costs of visiting the Site shall be at the bidder’s own expense.
10.2 The bidder and any of its personnel or agents will be granted permission by the Employer to enter its
premises and lands for the purpose of such inspection, but only upon the express condition that the
bidder, its personnel and agents, will release and indemnify the Employer and its personnel and agents
from and against all liability in respect thereof and will be responsible for death or personal injury, loss
of or damage to property and any other loss, damage, costs and expenses incurred as a result of the
11.0 Cheklist for submition of Technical Bid.
11.2 valid Registration Copy.
11.3 Valid E.M.D
AHMEDABAD MUNICIPAL CORPORATION
TERMS & CONDITION
( B ) GENERAL TERMS & CONDITIONS
1. Scope of Bid
1.1 The Ahmedabad Municipal Corporation hereinafter called "the Employer" invites Tender document for
the construction of works (as defined in these documents, hereinafter referred to as "the Works") detailed in
the table given in the IFB.
1.2 The Works consist of: “as Above "
Source of Funds
1.1 The expenditure on these Works will be met by AHMEDABAD MUNICIPAL CORPORATION.
3. Eligible Bidders
3.1 This invitation for bids is open to bidders who has necessary bid capacity and who meet the following
A bidder shall not be under a declaration of ineligibility for corrupt or fraudulent practice.
The bidders shall have a registration with State PWD, and/or CPWD for "D" class and or equivalent.
If contractor is not registered with AMC in the relevant class, on award of contract he shall be
required to register himself with AMC within 3 month's time.
Bidders shall provide such evidence of their continued eligibility satisfactory to the Employer, as the
Employer shall reasonably request.Subject to Submition of Succsesful Submition as per Clause –II of R.&B.
4. Eligible Material, Equipment and Services
4.1 At the Employer's request, the bidder having offered the lowest evaluated financial bid may be required
to provide evidence of the origin of materials, equipment, and services to the satisfaction of the Employer.
4.2 For purposes of Sub Clause 4.1, "origin" means the place where the materials are mined, grown,
produced or manufactured; similarly for equipments and from where the services are provided.
5. Qualification of the Bidder
To be qualified for award of Contract, bidders shall:
a) Submit a written power of attorney authorizing the signatory of the bid to commit the bidder; and
General information
All individual firms must complete the information in this form. Nationality information shall be provided
for all owner(s) or applicant(s) that are partnership or individually owned firms.
1 Name of firm:
2 Head office address With Contact no.:
3 Local office address (if any) With Contact no.:
4 Telephone/ Contact With name :
5 E-mail address:
6 Place of incorporation/registration:
7 Year of incorporation/registration:
Additional information regarding litigation, debarment, arbitration, etc.
Authorised Signeture Bidder
5.3 Disqualification
Even though the Bidders may meet the above criteria, they are subject to be disqualified for any of the
following reasons:
a) Misleading or false representation in the forms, statements and attachments submitted and included in
b) Record of poor performance such as abandoning the work, rescinding of contract for which the reasons
are attributable to the non-performance of the contractor, consistent history of litigation awarded against
the applicant or financial failure due to bankruptcy.
c) Has been identified by the Employer as poor performer in implementation of ongoing AMC works.
d) The bidder fill (tender) in percentage rate above or below and total amount (both in figures and words)
d) The bidder fill (tender) in percentage rate above or below and total amount (both in figures and words)
only in E-Tender (Online) Not to fill in hard copy of Tender documents
5.4 Debarment/Black listing
Notwithstanding the above, the Employer may debar or blacklist any of the bidder(s) for their misleading or
false representations in the forms statements etc. for the period to be decided by the Employer.
6. One Bid per Bidder
6.1 Each bidder shall submit only one bid per contract package either by himself or as a partner in a joint
venture. A bidder who submits or participates in more than one bid for a contract package will be
7. Bidding Documents
The bidder is expected to examine carefully the contents of all the above bid documents. Failures to comply
with the requirements of bid documents will be at the bidder's own risk. Pursuant to Clause 16, bids which
are not substantially responsive to the requirements of the bidding documents will be rejected.
8. Language of Bid
The bid, and all correspondence and documents related to the bid exchanged between the bidder and the
Employer shall be written in the English language. Supporting documents and printed literature furnished by
the bidder may be in another language provided they are accompanied by an accurate translation of the
relevant passages in the English language, in which case, for purposes of interpretation of the bid, the
English translation shall prevail.
9.1. Unless stated otherwise in the bidding documents, the Contract shall be for the whole works as
described in bidding documents, based on the percentage rate amount in the Bill of Quantities submitted
online by the bidder.
9.2. The bidder shall fill (tender) in percentage rate above or below and total amount (both in figures and
9.2. The bidder shall fill (tender) in percentage rate above or below and total amount (both in figures and
words) for overall items of the Works provided in the Bill of Quantities
10. Bid Validity
10.1 Bids shall remain valid as per Instruction to Bidders (ITB) after that deadline date for bid submission
specified in Clause. The Employer as non-responsive shall reject a bid valid for a shorter period.
10.2 In exceptional circumstances, prior to expiry of the original bid validity period, the Employer may
request the bidders to extend the period of validity for a specified additional period. The request and
the responses thereto shall be made in writing or by fax. A bidder may refuse the request without
forfeiting his bidder agreeing to the request will not be required or permitted to modify his bid but will
be required to extend the validity of his Bid Security for the period of the extension, and in compliance
with Clause 2 ( Financial Terms & Conditions) in all respects.
11. Format and Signing of Bid
11.1 The bidder shall prepare two copies of the documents comprising the bid as described in Instructions to
11.2 The bid shall be typed or written in indelible ink and shall be signed by a person or persons duly
authorized to sign on behalf of the bidder.
11.3 The bid shall contain no alterations, omissions or additions, except those to comply with instructions
issued by the Employer, or as necessary to correct errors made by the bidder, in which case the person
or persons signing the bid shall initial all such corrections.
11.4 All witnesses and sureties shall be persons of status and probity and their full names,
Occupations and addresses shall be printed below their signatures.
12. Deadline for Submission of Bids
Bids must be received by the Employer at the address specified above not later than the time and date
specified in the NIT.
Any bid received by the Employer after the deadline for submission of bids will be returned unopened to the
14. Signing of Agreement
At the same time that the Employer notifies the successful bidder that his bid has been accepted, the
Employer will direct him to submit the Performance Security and attend the Employer's office on a date
determined by the Employer for signing the Form of Agreement.
15. The selection process will lay high emphasis on the ability and competency of contractors to do high
quality work within the given time schedule.
16. The onus of providing, all necessary company / project related information, in appropriate manner and
medium, so as to demonstrate the competency of the bidder and to allow proper evaluation, will rest entirely
17. All clause shall be operative from the date of issue of work order and up to the expiry of original and
extended time limit.
18. Legal Condition:-
Corrupt or Fraudulent Practices
The Employer will reject a proposal for award if he determines that the Bidder recommended for award
has engaged in corrupt or fraudulent practices in competing for the contract in question. The Employer
will declare the firm ineligible, either indefinitely or for a stated period of time, to be awarded a contract
by AHMEDABAD MUNICIPAL CORPORATION if it at any time determines that the firm has
engaged in corrupt or fraudulent practices in competing for the contract, or during execution.
“corrupt practice” means behavior on the part of officials in the public or private sectors by which
they improperly and unlawfully enrich themselves and/or those close to them, or induce others to do
so, by misusing the position in which they are placed, and it includes the offering, giving, receiving,
or soliciting of anything of value to influence the action of any such official in the procurement
process or in contract execution; and
“fraudulent practice” means a misrepresentation of facts in order to influence a Procurement process
or the execution of a contract to the detriment of the Borrower, and includes collusive practice among
bidders (prior to or after bid submission) designed to establish bid prices at artificial non-competitive
levels and to deprive the Borrower of the benefits of free and open competition.
Municipal Commissioner reserves the rights to reduce/increase the scope of work and contract without
assigning any reason thereof.
If Ahmedabad Municipal Corporation is convinced that the Bidder has resorted to material
misrepresentation or provided fraudulent information / statement, the said Bidder will be liable for
disqualification / rejection at any stage.
Proof for fulfillment of eligibility criteria should be submitted along with Tender volume. If the Tender
volume is submitted without valid documents and without proof of eligibility criteria it will be rejected.
Those who do not meet with the eligibility criteria need not submit the Tender document.
Tenders, which do not fulfill all or any of condition or are submitted incomplete in any respect or are
conditional tenders, will be rejected.
Contractor shall be responsible to obey all Labour Laws, Environmental and Safety Laws.(the existing
laws as well as framed from time to time). Any penalties laid due to violation of such laws shall be
directly deducted from the contractor's outstanding.
19. Administrative Conditions:-
Safety and Signage
Contractor has to arrange for the complete safety of the persons working for project, users of the road i.e.
public and vehicles also. All the arrangements of traffic drums, metal / fiber cones, traffic blinkers,
traffic signs as per design, safety tapes etc. to be arranged at site. Necessary florescent marking on traffic
signs to be provided so that it should be visible at night. During night working hours safety in charge
personnel shall be provided with florescent jackets. This shall be Provided at no extra cost by the
bidder under attaché with specified in the tender documents under payable iteme.
Liaison with local authority for electrical connections for the AMC
The contractor is responsible for liaison with local authority for change in supply connection or new
connection on behalf of AMC. It includes filling the necessary application to power Supply Company,
follow up and getting the supply, filling the necessary test reports to the power supply company. All
official fees including security deposits and other expenses shall be of initially paid by the contractor.
AMC may support to get the temporary connection and may at its diseretien get the same
converted to permanent connection at the same of AMC if desired do,and contractor shall as no
extra cost support the same. In this case AMC my be as the remaining cost subject to approval.
20 :- CONTINGENT FEE:
The Contractor warrants that he has not employed any person to solicit or secure the contract upon
any agreement for a commission, percentage, brokerage or contingent fee. Breach of this warranty
shall give the Municipal Commissioner the right to cancel the contract or to take any other measure
as the Municipal Commissioner may deem fit. The warranty does not apply to commissions payable
by the contractor to establish commercial or selling agent for the purpose of securing business.
No officer, employer of the Municipal Corporation be admitted to any share or part of this contract or
to any benefit that may rise there from.
21:- OVERPAYMENT AND UNDERPAYMENT:
Whenever any claim fourths payment of a sum to the Municipal Corporation arises out of or under
this Contract against the contractor the same may be deducted by the Municipal Corporation from any
sum then due or which at any time thereafter may become due to the contractor under this contract and
failing that under any other contract with the Municipal Corporation or from any sum due to the
contractor with the Municipal Corporation (which may be available with Municipal Corporation), or
from his retention money, or he shall pay the claim on demand. The Municipal Corporation reserves the
right to carry out post payment audit and technical examination of the final bill including all supporting
vouchers, abstracts, etc.
The Municipal Corporation further reserves the right to enforce recovery of any over payment when
detected not withstanding the fact that the amount of the final bill may be included by the Contractor.
If as a result of such audit and technical examination any over payment is discovered in respect of any
work done by the Contractor or alleged to have been done by him under the contract, it shall be
recovered by the Municipal Corporation from the contractor by way of all the means prescribed above
or if any under payment is discovered by the Municipal Corporation, any amount due to the contractor
under this contract or under payment may be adjusted against any amount then due or which may at any
time thereafter become due before payment is made to the contractor from him to the Municipal
Corporation on any other contract account whatsoever.
If, at any time, there should be evidence of any lien or claim for which owner might have become
liable and which is chargeable to the contractor, the owner shall have the right to retain out of any
payment then due or thereafter to become due an amount sufficient to completely indemnify the owner
against such lien or claim or if such lien or claim be valid the owner may be or become due and
payable to the contractor. If any lien or claims remaining, unsettled after all payments are made, the
contractor shall refund or pay to the owner all money that the latter may be compelled to pay in
discharging such lien or claim including all cost and reasonable expenses.
Contractor shall not sub-let the work without permission of the authority.
Joint venture and subcontracting shall not be allowed under this tender
Addendum or corrigendum conveying any change or correction in respect of the work shall form the part of
the contract documents. The full consideration shall be given to such addendum or corrigendum before
submission of tender duly filled in by the contractor. Therefore, the contractors shall have to kindly refer the
tender for such addendum or corrigendum published by AMC through its website www.amc.nprocure.com
& www.nprocure.com 48 hours prior to the deadline of submission of the tender. Tenderers shall verify the
number of addendum issued and enclose the same with the tender documents , failing which the tenders shall
be liable for rejection and no any complaint in respect to this shall be entertained under any circumstances.
Seal and Signature of the Bidder Add. City Engineer
Date: (West Zone)
AHMEDABAD MUNICIPAL CORPORATION
TERMS & CONDITION
( C ) FINACIAL CONDITION
1. Cost and Currencies of Bidding
The bidder shall bear all costs associated with the preparation and submission of his bid and the Employer
will in no case be responsible or liable for those costs.
Currencies of Bid and Payment
The rates and the prices shall be quoted by the bidder entirely in Indian Rupees
All payments including advances, if any, shall be made in Indian Rupees.
2. Earnest Money Deposit :-
2.1 Bank guarantees (and other instruments having fixed validity) issued as surety for the bid shall be valid
for 28 days beyond the validity of the bid.
2.2 The EMD of the unsuccessful bidders, except for L1,L2 and L3 bidders, will be returned as promptly as
Early as possible as but not later than 28 days after the expiration of the period of bid validity.
2.3 The EMD of the successful bidder, along with second and third lowest tenders, will be returned when the
bidder has furnished the required performance security and signed the agreement.
2.4 Earnest Money Deposit may be forfeited
a) if the bidder withdraws his bid during the period of bid validity;
b) in the case of a successful bidder, if the bidder fails within the specified time limit to
i) Furnish the required Performance Security or
ii) Sign the Agreement.
3. (A) Security Deposit :-
Within 15 (fifteen) Working days of the date of receipt of the Letter of Intent (LOI) the successful
bidder shall deliver to the Employer, a Initial Security Deposit Shall be submitted as per C.E.
Circular.in the form of a Bank Guarantee/ DD/Locle MICR cheque for an amount equivalent to 5%
(five percent) of the Contract Price .
Failure of the same shall make the contractor liable for any penalty as decided by AMC. At present a policy is
framed by Audit department of AMC to charge 4% interest for the balance period and discontinuity period.
The Security Deposit to be provided by the successful bidder in the form of a bank guarantee as per
format shall be issued as per Memorendum of work.
(E) Retention :-
a). Retention @ 2% of the value of work done will be deducted from each RA bill. It will be released along
with release of payment of Final Bill.
4. Approved Bank: - As per Annexer -I
5. No advance for machinery or materials will be given.
6. Mobilization advance will not be given.
7. Quantities in B.O.Q. may vary up to any extent and contractor shall not claim any extra rate for the same.
8. Penalty: - 10 percent of the balance work on Date of Completion Date or extended time limit. & As
9. Tax, Duties on Materials
All charge on account of Octroi ,excise duties, terminal tax, sales tax. Service tax, VAT (exculding GST)
etc. on material procurement or any other component for the works from any source shall be borne by the
Special Clause:
As per construction works welfare cess Act – 1996 non-refundable one percent of tender amount shall be
deducted against works welfare cess.
Seal and Signature of the Bidder Add. City Engineer
Date: (West Zone)
General terms & conditions
1. Tenderer should be registered in PWD/ in Govt. R&B /CPWD / AMC or equivalent registration with any
other state Govt. or institutions. Copy of registration should be attached with tender document. Tenderer who
was not registred in AMC must be get registred in panel of approved AMC contractor.
2. A booklet of FORM B-1 of Gujarat State Roads & Building Department / Water Resources Department with
the correction slips made up to 15-08-1999 may be referred. (only English version) Clause No. -2 liquidated
damages for delay shall be overrule by A.M.C.’s M.C.circular no.- 9 dt. 18/05/2012.
3. In the specification “as directed" / "approved" shall be taken to mean "as directed / "approved" by the
Engineering in charge.
4. Wherever a reference to any Indian standard appears in the specifications, it shall be taken to mean as
reference to the latest edition of the same of force on the date of agreement.
5. In "Mode of measurement" in the specifications wherever a dispute arises in the absence of specific mention
for a particulars point / aspect, the same in the relevant Indian Standards shall be referred to.
6. All measurement and computations, unless otherwise specified shall be carried out nearest to the
following limits :-
i) Length, width and depth, Height 0.01 Meter
ii) Areas 0.01 Sq.mts.
iii) Cubic contents 0.01 Cu. mts.
In recording dimensions of work, the sequence of length, width and height (Depth) or thickness shall be
7. Definite particulars covered in the items of work, though not mentioned or elucidate in its specifications
shall be deemed to be included therein.
8. Approval of the samples of various materials given by the Engineer in charge or AMC's Consultant shall not
absolve the contractor from the responsibility of replacing defective materials brought on site or materials
used in the work found defective at a later date. The contractor shall have no claim to any payment or
compensation whatsoever on account of any such materials being rejected by the Engineer in charge.
9. The contractor’s rate for the item of work shall be for the work completed in all respect.
10. All materials including those of electrical shall be got approved by the Engineer in charge/ Architect before
using them in the work.
11. Materials as and when rejected by the Engineer in charge or AMC's Consultant shall be removed from the
site of work within 24 hours.
12. All work shall be carried out in a manner as per standard engineering practice.
13. All tools, templates, machinery and equipment for correct execution of the work as well as for checking
lines, levels, alignment of the works & all precautionary measures during execution shall have to be kept in
sufficient numbers and in good working condition at the site of the work. All excavated trench shall be kept
covered with barricade and caution tap.
14. Special modes of the construction not adopted in general Engineering practice, if proposed to be adopted by
the contractor shall be considered only if the contractor provided satisfactory evidence that such special
mode of construction and completion of work to the required strength and quality. Acceptance of the same
by the Engineer in charge shall not however, absolve the contractor from the responsibility of any adverse
effect and concordance of adopting the same in the course of exaction or completion of the work.
15. The contractor shall be responsible for observing the rules and regulation imposed under the "Minor Mineral
Act", and such other laws and rules prescribed by the Government from time to time.
16. All necessary safety measures and precautions (incl. those laid down in the various relevant Indian Standard)
shall be taken to engrave the safety of men, materials and machinery on the work and also of the work itself.
17. Quantity measured in the tender is approximate. It may increase or decrease looking to the quantum of actual
work for which no any claim shall be entertained by A.M.C.
18. Contractor shall have to execute extra item if required or as per need of AMC.
19. The work in general shall be carried out as per standard specifications of the relevant items to be executed &
as per the instruction of Engineer in charge & as per the guidance of AMC's Consultant for this project.
20. The general terms & conditions of the contract shall be applicable & shall be binding on the contractor. The
contract agreement shall have to be executed between AMC & the agency to which work is awarded for
21. For Tender amounting below 10 lakh LOI shall be issues within 3 days after received of sanctioned tender
and resolution.Within 10 days contractor has to submit SD and after reciveing SD Work order shall be issue
to contractor and the time limit shall be start from the date of issue of the written work order to the
For Tender amounting above 10 lakh LOI shall be issues within 3 days after received of sanctioned
tender and resolution .Within 15 days contractor has to submit SD and after reciveing SD work order shall be
issue to contractor and the time limit shall be start from the date of issue of the written work order to the
Security Deposit of 5% of sanctioned tender amount shall be deposited by pay order / demand draft /
cheque or Bank Guarntee of nationalized bank/scheduled bank only. Contractor shall have to sign contract
paper with AMC. The contractor shall be fined 4% of interest per year for delay in submission of S.D and
shall be deducted from contractor’s bill.
22. In case of any ambiguity in specifications mentioned in this tender, the interpretation given by M.C. Or His
Designeted Officer will be final and binding to the Contractor.
23. The contractor shall take no advantage of any apparent error or omission in drawing or specification and the
Engineer -in-charge shall make such corrections and interpretations as necessary to fulfill the intent of the
plants and specifications.
24. The quantities of items in BOQ (Bill of Quantities) may vary in case of necessity arises.
25. All prevailing taxes/duties chargeable by State Govt./Central Govt. and the Municipal Corporation. will be
payable by the contractor.
26. No any kind of price rise / price escalation / price variation for cement, steel or labour shall be paid.
27. Contractor is requested to see the site physically before tendering. He is also requested to quote the rates
keeping in view of all the points mentioned in relevant pages of tender documents.
28. Water Supply: The contractor shall arrange at his own cost, a suitable supply of piped water for the
construction of the works and provide a satisfactory supply of potable water for drinking, washing, sanitation
and cleaning down. The contractor will be responsible for all the costs where applicable of connection, meter
installation, water consumed, water required for testing purposes, disconnection and the laying,
maintenances and ultimate removal of any distribution system around the site.
29. Electricity: Electric supply will be made available at the site by the Contractor and the contractor must make
his own arrangements with the Corporation and Electricity Supply Authorities and with other contractors to
connect and to take a supply from such services, paying all costs in connection therewith.
The Contractor shall be entitled to use supply Electricity as may be available on the site for purpose of the
work and shall pay such charges as is fixed by the appropriate supply Authorities.
In case there is any delay in supply of power site of any interruption or fault in the power during the work.
No compensation shall be paid for idle labor staff, machineries and for use of diesel operating sets etc. as the
30. Tenders shall submit all the valid/certified documents in support of their initial/eligibility criteria mentioned
above along with the bid. They shall have also to submit the income tax clearance certificate and solvency
31. No advance such as secured advance machinery advance, mobilization advance or materials advance will be
32. The contractor shall get the electrical works executed through the authorized Government approved licensed
electrical person or firm in appropriate category in accordance to contractual provisions.
33. The electrical works shall be carried out strictly in accordance with the directives issued by Engineer in
34. Contractors shall not have any dispute or claim for any kind of compensations
(i) If the quantity stipulated in the tender items varies or the scope of work changes & thereby total amount of
(i) If the quantity stipulated in the tender items varies or the scope of work changes & thereby total amount of
work increases/ decreases.
(ii) If the work gets delayed/ postponed for some administrative/ technical decision what so ever.
35. In case of any dispute, decision of Municipal Commissioner shall be final and binding on the contractors.
36. Tenders which do not fulfill all or any of conditions or are submitted incomplete in any respect will be
rejected. Municipal Commissioner reserves the right to increase/decrease the scope of work. No any claim to
that effect shall be entertained. The Municipal Commissioner also reserves the right to reject any or all the
tenders without assigning any reason thereof.
37. The contractors are requested to quote their rates considering above tender conditions.
38. The contractor shall have to execute the contract agreement after received work order.
Even though in special case, If work is not started because of monsoon or any other special reason
(like site is not available and due to unavoidable circumstances arise), after evaluation of situation the actual
date of starting of work will be consider after approval of Dy.M.C. (West zone)
39. The Contractor shall not claim for increase or decrease in the quantity of the BOQ item or the scope of work.
40. The R.A bill / final bill payment shall be made as per the latest A.M.C policy / circular for the work done by
the contractor.
41. Conditional tenders will not be accepted.
Signature of contractor with seal Add City Engineer (W.Z.)
Date Ahmadabad Municipal Corporation
ybœtJtœ BGþrlrmvj ftuvotuhuNl
ftb btxulwk xftJthe œh Jt¤wk xuLzh ylu ftuLx[tfx
xuLzhh btxule Nh<tuu
1 y: yt xuLzh su <u Jdolt y.Bgw.ftu y&Jt fuLî{ y&Jt htsg mhfthle btLg gtœelt ftuLx[fxhtu Che NfNu.dJobuLxlt btLg ftuLx[[tfxhu
y.Bgw.ftuvtuo. bt btLg ftuLx[[tfxhtu le gtœebtkk hSMxuNl fhtJJtlwk hnuNu.
1 c: btLg ©uKelt ftuLx[tfxh <hefu ltuk^Kelwk «btKvºtle MJ «btKe< fhuj lfj xuLzh mt&u stuzJtle hnuNu.
1 f: xuLzhhle jtgft<
ftb sJtcœth xuLzhh <ubs su xuLzhh mwaJuj ftuLx[tfxhle ©uKebtk ytJ<t ntug <ubs ftb fhJt mûtb ntug <ublu s ytvJtbtkk
ytJNu. ftb yvt<t vnujt ftuLx[tfxhu ftb mkk<tu»tfthf <ubs xtRb jebexbtkk vwÁk fhJt sYhe mJj<,ylwCJ, ûtb<t ylu
VtgltLmegj hemtumo hsw fhJtlt hnuNu.
1 z: ybœtJtœ Bgwrlrmvj ctuzo XhtJ lk - 3836,<t.25/11/2011 &e b¤uj bkswhe ylwmth <&t mexe.Rsluh mh¾gwjh,lk -
17,<t.09/12/2012 bwsc ybœtJtœ Bgwrlrmvj ftuvtuohuNlbtk ftuLx[t¾xh hSMxuNl Ve,heLgwyj Ve <&t yvd{uzuNl Ve ylu
btv œkztu ægtlbtk htFe <u bwsc ybj fhJtltu hnuNu.
1 R: xuLzh Ch<t vnujt xuLzhhu mtRx rlheûtK fhe juJwk. xuLzhh ftblt «fth, ngt< hM<t, vtKe btdo, mkkath ylu JvhtNlt ceò
hM<tytu&e mkk<wÐ ntuJtlwk btle juJtbtkk ytJNu. xuLzhhu ftblu mtRx ylu rcÕzekkd(fu su ftb fhJt, ftb vwhwk fhJt <&t ftblt
buRxulLm btxu cltJuj ntug).<ubs xuLzhhu yt mtRxlt ftb btxu, rcÕzekkd btxu, gtzo, zevtu btxule søgt vtu<tle he<u bu¤Je juJtle
hnuNu. (xuLzhlwk ftb fhJt, ftb vwhwk fhJt <&t ftblt buRxulLm btxule søgt)
2: yt ftble mbg bgtoœt xuLzhbtk sKtÔgt bwscle hnuNu. (bubtuhuLzbbt sKtJuj «btKu)
3: xuLzh Jujezexe rvhegz xuLzhbtk sKtÔgt bwsc hnuNu. (bubtuhuLzbbt sKtJuj «btKu)
4: xuLzh Ch<e JF<u yluoMxble ChJtle hnuNu.
xuLzh Vtubo ylu ylwmwrabtkkle œhufu œhuf Ftje søgt xuLzh Chlthu Chuje yt mt&u btufjujt œM<tJus vh< fhJtlt hnuNu.
6: ftuLx[tfxhtuyu leaule ctc<tu ft¤SvwJof JtkkaJt rJlkk<e Au.
1) J^w fu ytuAtle xftJthelt œh Nçœtu <ubs ytkkfztbtkk ytvJt.
2) ftuR fkkvlelu ltbu xuLzh juJtbkkt ytÔgwk ntug <tu fkkvle J<e xuLzh vh mne fhlth Ôgrf<lu yr^f]< fh<wk bwFðgthltbwk xuLzh mt&u
hsw fhJtlwk hnuNu.
3) Bgwrl.ftuvtuohuNllt «J<obtl rlgbtu ylwmth yluMxble ChJtle hnuNu.ylu xuLzh mt&u cezJtle hnuNu.
4) ftuLx[tfxhu RLfbxuût mkkckr^< vtl lkch <&t cukf zexuRj ytvJtle hnuNu.
5) ftuLx[tfxh vtmu ydtWlt ylwCJt ykdult «btKvºttule lfj xuLzh mt&u hsw fhe NfNu.
6) xuLzh Nh<tu ylu MvuNeVefuNl <&t CtJ vºtflt œhuf vtlt ylu rJd<tu vh ftuLx[tfxhu mne fhJe.
7) <btb mw^tht, AufAtf ylu Dwkxujt jFtK vh ftuLx[tfxhu xwkfe mne fhJe.
7: AufAtf xuLzh Chlthlu sKtJJtbtkk ytJu Au fu xuLzh œM<tJustult jFtKbtk ftuR AufAtf fu VhuVth fhJt œuJtNu lrn ylu ytJe ftuR
AufAtf fu VuhVth juJtNu lrn, <ultkk jFtKbtkk ftuR Cwwj ntug <tu <ult vh l Dwkx<t Ftuxt jFtK fu ytkkfzt vh Auftu bthelu <ult mtawk jFtK
fu ytkkfzt MvÐ Wfju <u he<u jFJt. «ðguf mw^tht vh xwkfe mne fhJe.
8 y: xuLzh hsw fh<tkk vnujt Ftm fhelu xuLzhbtk œNtoJuj mwaltytulwk vtjl fhJtbtkk ytÔgw lrn ntug <tu xuLzh ybtLg dKJtbkkt ytJNu
<ule ltuk^ juJt rJlk<e Au. J¤e yt Vtubolwk bwFv]ƒ ylu ftuLx[tfxhtult btdoœNol btxu mtbtLg rlgbtu ylu mwaltytu vK ft¤SvwJof
JtkkaJt rJlkk<e Au.
1) ftuRvK fthK œNtoÔgt rmJtg ftuRvK fu c^t xuLzhtu yMJefth fhJtltu nf yctr^< hnu Au.
8 c: Wvhle ctc<tu Wvhtkk< xuLzh leault mkkstudtubtkk <h< ybtLg XhJtlu vtºt &Nu.
1) xuLzh Chlth, rlg< ftb y&Jt ftb btxu bkswh fhuj y&Jt CtJ vºtflt ftuR ftuz y&Jt vîr< y&Jt rJd<tubtkk bwfuj Nh<
y&Jt mw^thtbtkk ftuR VuhVth mwaJ<t ntug.
2) xuLzhlwk ftuR vtlwk fu vtlt ftZe ltkkÏgwk/ltkkÏgt ntug fu cœÕgwk/cœÕgt ntug.
3) c^t mw^tht J^tht y&Jt atukxtzuje ftvjeytu Wvh xuLzh Chlthu xwkfe mne l fhe ntug.
4) xuLzhbtk <ubKu ftuR AufAtf fhe ntug, ylu
5) xuLzh Chlth y&Jt vuZele ctc<btkk œhuf Ctdeœth y&Jt <u ykkdulwk bwFðgthltbwk ^htJlth Ôgrf< mne l fhu y&Jt xuLzhbt <u btxu
htFJtbtkk ytJuje søgtbtkk mne/mneytu Wvh ftuR mtûteyu mtF fhe l ntug.
8 f: Nh<e xuLzh MJefthJtbtk ytJNu lne.
8 z: xuLzh MJefthJw , hœ fhJw, ftulu ytvJw ylu fgt CtJ&e ytvJw <u ykdu Bgwrl. frb§h©eltu rlKog ytFhe hnuNu. ftuR fthKmh stu
ftuLx[tfxhlu ftb l ytve Nftg <tu <u ykkdu ftuLx[tfxh ftuRvK «fthltu lwfNtle fu J¤<hltu nff œtJtu fhe NfNu lrn fu ftgœtfeg
ftgoJtne yt ykkdu &R NfNu lrn. xuLzh bkswh >ltu y&o ftb ytve s œuJtlwk Au <uJtu &R NfNu lrn.
9: rJmkkdr< ylu rnmtc stud:
nt& ^hJtlt ftbtule ctc< œNtoJ<t CtJ vºtf btklt sÚ&t ylu hfble ftuRvK Cwjawf leault rlgbtu ylwmth mhCh fhJtbtkk ytJNu.
1) xuLzh Chlthu œhlt Ftltbtkk sKtJuj Nçœtu ylu ytkkfzt Jåau ftuR ymkkdr<lt fumbtkk Nçœtubtkk sKtJuj hfb btLg htFJtbtkk ytJNu.
2) yufb œh ylu sÚ&tlt Ftuxt dwKtfthlt fthKu ftble ctc<tu œNtoJ<e CtJ vºtf lt Ftltbtkk&e hfbbtkk Cwj sKtg <tu yufb
œh btLg htFJtbkkt ytJNu ylu œhlt yt^thu dwKtfth mw^thJtbkkt ytJNu.
3) yufblt Ftltbtkk&e <ubs ytd¤ Fuka<t mhJt¤tle <btb Cwjtu mw^thJtbkkt ytJNu.
4) ctc<tu y&Jt mhJt¤t mtbu vwhu ytkkfzu fhuj ftuR vK ctc< ægtlbtkk juJtbtkk ytJNu lrn.
10y: ftbltu «tud{um mbg bgtoœt bwsc fhJtltu hnuNu.
xuLzhbtk ftuLx[t¾xh îtht Chujt CtJ <btb «fthlt su <u «J<o<t mhfthe xuût mrn<lt CtJ dKJtbtk ytJNu. ylu <ubtk atjw
ftb œhBgtl su ftuR VuhVth &Nu <ultu J^thtu awfJJtbtk ytJNu lrnk.
10c: mûtb m•tt îtht xuLzhle bkswheltu XhtJ vtzgt ctœ ( LOI) ytvJtbtk ytJNu ðgth ctœ rœl - 15 btk rm¾gtuhexe zevtuÍex sbt
fhtJJtle hnuNu. rm¾gtuhexe zevtuÍex btuze ChJtlt rfMmtbtk Bgwrl.ftuvtuohuNlbtk «J<obtl rlgb ylwmth ftgoJtne fhJtbtk
10f: bkswh &guj xuLzhle mbgbgtoœtbtk ftbdehe vqKo l &tg <tu mbgbgtoœt ctœlt FhuFh ctfe ftble hfblt 10% juFu (jefJezexe
zubuSm) vulÕxe Jmwj fhJtbtk ytJNu.
xuLzh Chlthu yu Jt< mbS juJtle hnuNu fu <uKu xtkkfujt œh vwhtk &gujt ftb btxult Au ylu <ubtk bswhe, vtjF, ÃjtLx,
œuFhuF,mhJem-ftbdehe, Jes¤e, htugÕxe ylu ytufx[tug Jduhu ykkNu <btb Faoltu <&t sYh sKtg <tu ylu ðgthu ht<vt¤elt ftblu
juJt c^t J^thtlt Faoltu mbtJuN &Nu ylu xtkkfujt CtJ fu œh fh<t J^thtle ftuR awfJKe ykkdult <ublt ftuR œtJt ægtlbtkk juJtNu
lnekk ylu xuLzh Chlth Ftuxe hswyt<lu fthKu y&Jt ftuR Ôgrf<yu(vAe<u ctkk^ftb rJCtdltu fboathe ntug fu l ntug)<ublu ytvuje
btne<elu yt^thu vtA¤&e ftuR œtJt hsw fhJt nfœth hnuNu lnekk. <ublw xuLzh ChJt <&t <ubtkk swœt swœt CtJ ylu œh ChJt btxu
sYhe yuJe <btb btne<e vtu<tlt vûtu l bu¤Je NfJtlu fthKu vtu<u xuLzh hsw fhJtlu je^u y&Jt <ubtkk&e WCt &<t ftuR stuFb fu
sJtcœthebtkk&e Axfe NfNu lnekk. mœh ftbbtk ftuR vK ò<lt ctk^ftblt bxehegj Wvh CtJ J^thtu ytvJtbtk ytJNu lrnk.
11 c: ftuLx[tfxhtulu vubuLx / hlekd cej Bgwrl. frb§h©elt su <u «J<obtl rlgb bwsc fhJtbt ytJNu.<&t Bgwrl. frb§h©e/mexe
Rsluh©e lt su <u JF<ltk mh¾gwjh «btKu ftbdehe/ybj fhJt ckDlf<ot hnuNu.
11 f: ftuLx[t¾xhlt œhuf hlekd cejbtk&e ftuLx[t¾xhlu awfJJtle &<e fwj hfb Wvh (xuLzh bwsclwk vubuLx +
yu¾x[t ytRxb) 2 % juFu hexulNl ble ftvJtbtk ytJNu su VtRlj cejbtk vh< ytvJtbtk ytJNu.
11 z: htsg / fuL÷ mhfth©elt JF<tuJF<lt ftgœt bwsc su ftuR hfble fvt< fhJtle &Nu <u bwsc ftuLx[[tfxhlt cejbtkk&e fvt<
12: yu)fhth mkkc^e œM<tJustu fhthlt ydðglt Ctd dKtNu ylu <u mD¤t mne<lt fhth mbd{ ftblu jtdw vzNu.
ce)xuLzhbtk œNtoJuj ftb mkkck^e œM<tJusbtkk œNtoJuj rJd<btkk rJmkkd<<tlt rfMmtbtk leau œNtoJuj ¢btlwmth
œM<tJusbtkk œNtoJuj rJd< d{tng htFJtbkkt ytJNu.
yu) yufb ylu fœ
2) xuLzh Vtubolwk CtJvºtf
z[tuRkdbtk fœ, ytfth, ytkkfzt fœta Ftuxt ntug <tu btvujtkk fœ, ytfthlu ylwmhJwk.
2) xuLzh Vtubole ylwmwra-ce
Cwj Chujt fu Ftuxt JKollt rfMmtbtkk yt mkkck^e Wvhefûttyu rJmkkd<<t ykdule ltuk^ bwfe
yuze.me.R/zu.Bgwrl.frb./Bgwrl.frb.le bkswhe bu¤JJtbtk ytJNu ylu <u bwsc fhJtbkt ytJuj rlKog ykkr<b dKJtbkkt ytJNu.
13 : xuLzhhu z[tuRkd fu MvuNeVefuNlbtkk hnuje ftuR ûtr< fu Ftbeltu duhjtC juJtle fturNN l fhJe ylu Rsluh Rl-atsuo Ãjtl <&t
MvuNeVefuNlle ûtr<ytu mw^thJe <&t <ulwk mtawk y&oDxl fhtJJwk.
14 : yt Wvhtk< y.Bgw. ftuvtuo. lt slhj ftuLx[tfx fLzeNl vK btLg htFJle hnuNu.
15 : yufe JF<u yuf fh<t J^w søgtytuyu ftb NY fhJtltu Jfo ytuzoh b¤u <tu ftb yuf mt&u s c^u NY fhJw vzNu.
16 :atjw ftbu mrJom jtRllu lwfNtl l &tg <u he<u ftb fhJtlw hnuNu. stu ftuR mrJom jtRllu lwfNtl &Nu <tu <ule mkvwKo sJtcœthe
(òlbtj) ftuLx[tfxhle vtu<tle hnuNu. mtRx Wvh ftb œhBgtl bswhtu fu sl<tlt ftuR btKmlt òlbtj lu lwfNtl &tg <ule
sJtcœthe ftuLx[tfxhle hnuNu.vtujem Vhegtœ &tg <tu <ule sJtcœthe vK ftuLxtfxhle hnuNu. CuFz Dme l vzu <ule sJtcœthe vK
vtujem Vhegtœbt ftuLx[tfxhle hnuNu.CuFz Dme l vzu <u btxu mjtb<elt vdjt (suJt fu œtuhzwk ctk^e bswh Ftztbtkk W<thJt, mtuhekkd
ylu Mx[[xekkd fhJt rJduhu) je^t Jdh bsqhlu Ftztbtkk W<thNu <tu ftuLx[[tfxh s vtujem Vhegtœbt sJtcœth hnuNu ylu
Bgwrl.ftuvtuohuNlltu ftuRvK MxtV ytlt btxu sJtcœth hnuNu lrn.ytxjwk mbSlu s xuLzh ChJwk. Bswhtultu rJbtu vK W<thJtu.
17 : ftuLx[tfxh îtht xuLzhbt œNtoJuj MveNeVefuNl bwsc MxtLzzo bxehegÕm MvuNeVefuNl bwsc jtJJtlt hnuNu.<&t sYh sKtg <tu
xuMxekd fhtJJtlwk hnuNu.<&t yt ykdu «Joðbtl Bgwrl.ftuvtuohuNlt rlgb bwsc bxehegÕm fu ceò xuMxed hevtuxo ftuLx[tfxhu vtu<tlt Fauo
ftuvtuohuNl sKtJu <u søgtyu fhtJJtlt hnuNu. bxehegÕm jtJJt fu jR sJtltu mkvwKo Fao ftuLx[tfxhu CtudJJtltu hnuNu.
18 : M&¤ vrhrM&r< / sYhegt< bwsc ftb fhtJ<t xuLzhlt ytRxblt sÚ&tbtk J^ ^x &tg <tu rlgb ylwmth <u ykdu ftb fhJt
ftuLx[tfxh ck^tgujt Au.
19: mtRx vh jtJJtbtk ytJuj btj mtbtl hesufx fhJtbt ytJu <tu <whk< rœl 1btk vh< jR sJtltu hnuNu.
yLg&t <ule lwfNtlle sJtcœthe ftuLx[tfxhle hnuNu.
20 :ftuLx[tfxhlu su ftuLx[tfx ytvJtbtk ytJu Au.<ubt mhfth©elt «Joðbtl rlgb bwsc ve.yuV/juch
yufx/vtujemlt ftgœtlw vtjl fhJtlwk hnuNu <&t yt ykdu Bgwrl.ftuvtuohuNl îtht su btne<e btkdJtbtk ytJu <u ytvJtle hnuNu.
21: ftuRvK ftgœtfeg jexeduNl ybœtJtœ Nnuhle ftuxobt hnuNu.
22: btj su <u Mxtumo Wvh y&Jt mtRx Wvh jtuftulu lz<h l &tg <u he<u mwalt bwsc W<thJtltu <ubs dtuXJJtltu hnuNu.
23: ftuR vK mhfthe fhJuht ChJtle <btb sJtcœthe ftuLx[tfxhle hnuNu.
24: yt xuLzhbtkk stu ftuR ytRxb hne dR ntug <tu <u y&tJ M&¤ M&e<e bwsc xuLzhbtk mbtJuN l ntug <uJe J^thtle ftbdehe fhJtle
&tg <uJt rfMmbtk Bgwrl.ftuvtuohuNlt «Joðbtl rlgb ylwmth J^thtle ytRxblt CtJ lffe fhJtbtk ytJNu ylu <u bwsc awkfJKe
25: atjw ftb œhBgtl «tuxufNlle mkvwKo sJtcœthe ftuLx[[tfxhle hnuNu. subtkk vevzt,œtuhzt, Cgmwaf ctuzo,ÃjtMxef vxe,rJ. ftuLx[tfxhu
jtJJtlwk ylu mtaJJtlwwk hnuNu. ylu ftuRvK yfMbt< &Nu <tu <ule mkkvwKo sJtcœthe ftuLx[tfxhle hnuNu.
26: M&¤ Wvh atjw ftbdehe œhBgtl ftb fhlth ftuLx[tfxhlt bswh / fboathe y&Jt yLg Ôgrf<lt yfMbt<lt rfMmbtk juch yufx
bwsc fhJtle &<e ftgoJtne <&t vtujem ftgoJtnele sJtcœthe ftuLx[tfxhle hnuNu.
27: stu MxtV mqalt ytvu <u bwsc mwalt vtu&e ftuLx[tfxhu htFJtle hnuNu. <ubt œhhtus fhuj ftbdehe <&t yr^ftheytuyu ftb
mw^thJt fu vtu{d{um J^thJtlt ltuk^ fhuj ntug <tu <ulwk ftuBÃjtgLm ytvJtlwk hnuNu ytJe ltu^lt sJtc l &gu fu <u «btKu M&¤ Wvh
ybj l &gu ftuLx[tfxhlu vulÕxe fhJtle mððtt yuze.mexe yuLSlehgh©elu hnuNu.
28: œhuf ytRxblt MvuNeVefuNl ybœtJtœ Bgwrlrmvj ftuvtuohuNlltk bkswh &guj <&t btLg htFuj MvuNeVefuNl Nh<tu bwsc hnuNu su
ytRxbbtk MvuNeVefuNl l ntug <uJt mkstudtubtk yuze. mexe.yuLSlegh©eltu rlKog ytFhe hnuNu. Jtuxhekd fhJtbtk lrn ytJu fu
œhhtus J^thtltu zucheÍ WvtzJtbtk lrn ytJu <tu ftuLx[tfxhlt Fauo ylu sutFbu Jdh ltuxemu Jtuxhekd fhtJJtbtk <&t zucheÍ
WvtzJtbtk ytJNu ylu cejbtkk&e hfb ftve juJtbtk ytJNu.
29: juch JuÕVuh Vkkz btxu ntjbtkk htsg mhfth©eyu fhuj nwfb bwsc 1%(yuf xft) hfb cejbtk&e ftve juJtbt ytJNu.
30: su ftbtubtk atubtmtlt mbgdt¤tlu ctœ ytvJtle Nh<tultu WÕjuF ntug ðgtk atubtmtltu vehegz <t.15 swl &e 30 mÃxuBch
Mþ^eltu dKJtbtk ytJNu. yt mbg œhBgtl ftuLx[tfxh îtht ftbdehe fhe Nftg <ub l ntug <tu <u mbgdt¤tu ctœ fhe ftble
mbgbgtoœt dKJtbtk ytJNu <&t sYhegt< Bþscle xtEb jebex J^the vK ytvJtbtk ytJNu.
31: ftuLx[tfxhu «J<obtl ybœtJtœ Bgw. ftuvtuohuNl lt JF<tuJF< lt mhfgwjh bwsc ve yuV,Jux <&t ylu muÕm xuût lu jd<t vwhtJt
vubuLx fh<e JF<u sYh vzu&e hsw fhJtlt hnuNu.
yufhthlwk Vtubo
1) nwk/ybu yt&e yufhth fhwk Awk/fheyu Aeyu fu yt xuLzh hsw fh<tkk vnujtkk buk/ybu M&¤le bwjtft< je^e Au ylu ftblu
jd<t btjmtbtl, bswhe ylu ceS ctc<tulu jd<e M&trlf vrhrM&r<le ò<-btne<e bu¤Je Au.
2) nwk/ybu yt&e yufhth fhwk Awk/fheyu Aeyu fu yt ftuLx[tfxhtule Nh<tu rJd<tu ylu xuLzhlu jd<t œM<tJustu ft¤SvwJof
yÇgtm fgtuo Au ylu <u bwsc <ultu ybj fhJt mkkb< Awk/Aeyu.
ftuLx[tfxhle mne - rm¬tu yuze.mexe yuLSlegh
btuctEj lkch mt&u (vrùb Ítul)
AHMEDABAD MUNICIPAL CORPORATION
ENGGNIERING DEPARTMENT
GENERAL SPECIFICATION
Time limit for the work shall be 12 months after the order to start the works. Progress of work should be in
proportion to time limit. The details of reinforcement of R.C.C. work shall be as per design and instructions
of Add. City Engineer and his order will be considered final.
The contractor shall have to maintain account of steel, cement and other materials that may be brought by
him on site. This account shall be regularly maintained and kept open for inspection by Municipal Staff.
Watering of all the items shall be as per instructions otherwise no payment shall be made to contractors.
Mixing of concrete shall be done by concrete mixer machine. Arrangements of binding vibrator for R.C.C.
works if required shall have to be made by the contractor .
The contractor shall be remain responsible for Workmen’s compensation if any accident. The contractor
shall arrange for barricading at night and arrangement of Pagi at night to direct the traffic. He shall be
responsible for any damage to public. If any incident happen, during the execution of work. In case of
dispute for unseen or overlooked items the decision of the Dy. City Engineer shall be final. The contractor
shall have to give site clean of all rubbish during the work and at the time of completion of work and hand
over the site with final finishing of the work as directed. All the rejected materials shall be removed from
site within 24 hours by contractor at this risk and cost. Debris shall have to cart daily from site.
For mixing mortar either for masonry or for plaster or for any other purpose contractor shall have to
prepare through of bigger size and mix the mortar in the required proportion. In on case he shall be allowed
to mix the mortar either on floor or any finished surfaces. The contractor shall have to make his own
arrangement for water required for the work.
If any extra item crops up during the progress of work the same shall be carried out by the contractor and he
shall be paid at the rate fixed by Add.C.E. as per the rate analysis based on latest SOR or if item is not
available in SOR than based on current market rates. In case of extra item decision of Add. City Engg. shall
remain final regarding rate.
If in the interest of the Corporation it is necessary to change either any site or the design of the propose work
the contractor shall carry out the same at his quoted rates without charges any extra and the contractor will
have to carry out the works and he will be paid at the rate quoted by him. No claim for extra rate for
subsequent changes in site and design is entertained.
The cubical contents of the cement bag shall be taken as 1-20 cft. Per bag and the contractors shall have to
prepare the measures boxes according to this measure.
Octroi exemption passes shall not be given for any materials required for the work. Contractor will be fully
responsible for compliance of the various provisions under contract Act. 1970 and the Rules framed the to
The tender for the work shall remain open for a period (120) days from the date of opening of the tenders for
this work and that the tenderer shall not be allowed to withdraw on modify the offer on his own during the
period. If any tenderer withdraw or makes any modifications or addition in the terms and conditions of his
tender not acceptable to the Municipal Corporation the Municipal Corporation shall without prejudice to any
right or remedy be at liberty to forfeit in full the said earnest money and black list the contractor.
If work is not started within specified time limit the penalty as per rule & tender condition delay of start
shall be recovered separately from the immediate bills payable to the contractor. Contractor has to make his
own arrangement for procurement of steel and cement.
Contractors should note the following conditions carefully:-
i) Conditional tender shall not be accepted.
ii) All tenders are to be submitted in duplicate without which the tenders are liable to be rejected.
iii) In case of tender downloaded from website, tender fee & EMD should be submitted in form of
iv) Condition of Form - B1 Standard Specification of material & code of practice will be applicable.
Form B1 can be is available in website. Specification shall be as per ' R& B Dept. - Govt. of Gujarat
booklets of Building Works & and Road Works Specifications published by Gujarat Book Depot,
Sector-21. Gandhinagar.
CONTRACTOR'SSIGNATURE ADD.CITY ENGINEER
& STAMP (West Zone)
TECHNICAL SPECIFICATIONS
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT
STANDARD DETAILED TECHNICAL SPECIFICATION OF ITEMS
Excavation for foundation upto 1.5 M depth including sorting out and stacking useful materials
disposing of the excavated stuff upto 50 meter lead in loose or soft soil.
Any soil which generally yields to the application of ackaxes and shoves, phawaras rakes or any
such ordinary excavating implement or organic soil, gravel silt, sand turfloam, clay, peat etc., fall
under this category.
Clearing the site :
The site on which the structure is to be built shall be cleared and all obstructions, loose stone,
materials and rubbish of all kind, bush, wood and trees shall be removed as directed. The
materials so obtained shall be property of the Government and be conveyed and stacked as
directed. within 50 M. lead. The roots of the trees coming in the sides shall be cut and coated with
The rate of site clearance is deemed to be included in the rate of earth work for which no extra will
After clearing the site, the center lines will be given by the Engineer-in-charge. The contractor shall
assume full responsibility for alignment, elevation and dimension of each and all parts of the work.
Contractor shall supply laborers, materials, etc. required for setting out the reference marks and
bench marks and shall maintain them as long as required and directed.
The excavation in foundation shall be carried out in true line and level and shall have the width
and depth as shown in the drawings or as directed. The contractor shall do the necessary shoring
and shutting or providing necessary slopes to a safe angle, at his own-cost. The payment for such
precautionary measures shall be paid separately if not specified. The bottom of the excavated
area shall be 1 evened both longitudinally and transversely. as directed by removing and watering
as required. No earth filling will be allowed for bringing it to level, if mistake or any other reason
excavation is made. deeper or wider that shown on the plan or directed. The extra depth or width
shall be made up with concrete of same proportion as specified for the foundation concrete at the
cost of the contractor. The excavation up to 1.5 m. depth shall be measured under this item.
Disposal of the excavated stud :
The excavated stuff of the selected type shall be used in filling the trenches and plinth or leveling
the ground in layer including ramming and watering etc.
The balance of the excavated quantity shall be removed by the contractor from the site of work to a
place as directed with lead upped 50 M. and all lift.
Mode of measurement and payment :
The measurement of excavation in trenches for foundation shall be made according to the sections
of trenches shown on the drawing or as per sections given by the Engineer-in-charge. No payment
shall be made for surplus excavation made in excess of above requirements or due to slopping
and sloping back as found necessary on account of conditions of soil , and requirements of safety.
The rate shall be for a unit of one cubic meter.
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting out and stacking
of useful materials and disposing off the excavated stuff upto 50 Meter lead.(C) Hard
The rate shall be for a unit of one cubic meter.
Filling available excavated earth in trenches, plinth, sides of foundation etc. incl. watering and
The earth obtained from excavation shall be filled in layers not exceeding 20 cms. in depth and
water thoroughly after each layer and shall be properly consolidated with rammers so that no
hollow voids remain there. In general the work shall be carried out in the best manner so that no
hollow voids remain after work. Workmanship in general confirm to C –2.
Mode of Measurement shall be on cubic meter basis.
filling in plinth with sand under floors including watering, ramming consolidated and
dressing etc. complete.
Sand shall conform to M.
The sand to be used for filling shall be free from salts, organic or other foreign matter, All clods of
earth shall be broken.
As soon as the work in foundation has been completed and measured, the site of foundation shall
be cleared of all debris, brick bats, mortar dropping etc; and filled with sand in layers not exceeding
20 Cms. Each layer shall be adequately watered rammed and consolidated before the succeeding
layer is laid. The sand shall be rammed with iron rammers where feasible and with the butt ends
of crow-bars, where rammer cannot be used.
The plinth shall be similarly filled with sand in layers not exceeding 20 Cms adequately watered
and consolidated by ramming with iron or wooden rammers. When nfilling reaches finished level,
the surface shall be flooded with water for at least 24 hours and allowed to dry and then rammed
and consolidated.
The finished level of filling shall be kept to shape intended to be given to floor.
In case of large heavy duty flooring like factory flooring, the consolidation may be done by power
rollers, where so specified. The extent of consolidation required shall also be as specified.
Mode of measurement and payment :
The payment shall be made for filling in plinth and trenches, No deduction shall be made
for shrinkage or voids if consolidated as instructed above
The rate includes cost of collecting carting sand with all lead and labour for filling the same in plinth
The rate shall be for a unit of one cubic meter.
Filling in foundation and plinth with murrum or selected soil in layers of 20 cm. thickness including
watering, ramming and consolidating etc. Complete
Filling in foundation and plinth with murrum or selected soil shall be filled in layers not exceeding 20 cms. in depth and
water thoroughly after each layer and shall be properly consolidated with rammers so that no hollow voids remain there.
In general the work shall be carried out in the best manner so that no hollow voids remain after work. Workmanship in
general confirm to C –2.
Mode of Measurement shall be on cubic meter basis.
Providing and laying cement concrete1:5:10 (1-Cement: 5-coarses sand and:10-hand
broken stone aggregates 40mm nominal size) and curing complete excluding cost of
formworkin (A) Foundation and Plinth (upto 10 ton)
Providing and laying cement concrete1:4:8 (1-Cement: 4-coarses and:8-hand broken stone
aggregates 40mm nominal size) and curing complete excluding cost of formworkin (A)
Foundation and Plinth (upto 10 ton)
Providing and laying cement concrete1:3:6(1-Cement:3-coarse sand:6-hand broken stone aggregates 40mm
nominalsize) and curing complete excluding cost of formworkin(A)Foundation and Plinth (upto 10 ton)
Providing and laying cement concrete 1:3:6 (1-Cement:3-coarse sand:6-hand broken stone
aggregates 20mm nominal size) and curing complete including cost of formwork in (A) wall
caps/ coping (upto 10 ton)
Providing and laying cement concrete work 1:2:4 ((1-Cement:2-coarse sand:4-graded aggregates 20mm
nominal size) curing complete excluding cost of formwork and reinforcement ( up to {(a) to (c)}
Provdg. & laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregates 20 mm nominal
size) for reinforced concrete chhajjas not exceeding 10 cm. thickness upto floors two level including
finishing the exposed surfaces with cement mortar 1:3 (1 cement : 3 find sand) to give a smooth and even
surface centering and form work and curing complete excluding cost of reinforcement.
1.0 Materials: Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6, Grit shall
conform to M-8 Graded stone aggregate 20 mm nominal size shall conform to M-12.
2.1 The concrete mix is not required to be designed by preliminary tests. The proportion of the concrete mix shall
be 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 10 mm nominal size) by volume. Concrete work
shall have exposed concrete surface or as specified in the item.
2.2 The designation ordinary M-100, M-150, M-200, M-250 specified as per I.S Correspond approximately to
1:3:6, 1:2:4, 1 1/2 :3 and 1:1:2 nominal mix of ordinary concrete by volume respectively.
2.3 The ingredients required for ordinary concrete containing one beg of cement of 50 Kg. by weight (0.0342 Cu.
M) for different proportions of mix shall be as under:
Grade of Total quantity of dry Proportion of fine Quantity of
concrete aggregate by volume aggregate to coarse water per
per 50 Kgs, of cement aggregate 50 Kgs. of
to be taken as the cement
sum of individual maximum.
volume of fine and
coarse aggregates,
M-100 (1:3:6) 300 Liters Generally 1:2 for fine 34 Liters
M-150 (1:2:4) 220 ” aggregate by volume but 32 “
M-200 (1:1 1/2 :3) 160 “ subject to and upper 30 “
M-250 (1:1:2) 100 “ limit of 1:1/2 and lower 27 “
2.4 The water cement ratios shall not more than those specified in the above table. The cement content of the mix
specified in the Table shall be increased if the quantity of water in a mix has to be increased to overcome the
difficulties of placement and compaction so that the water cement ratio specified in the Table is not exceeded.
2.5 Work ability of the concrete shall be controlled by maintaining a water cement ratio that is bound to give a
concrete mix which is just sufficiently wet to be placed and compacted without difficulty with the means
2.6 the maximum size of coarse aggregate shall be as large as possible within the limits specified but in no case
greater than surround all reinforcement thoroughly and to fill the corners of the form.
2.7 For reinforced concrete work, coarse aggregates having a nominal size of 20mm are generally considered
2.8 For heavily reinforced concrete members as in the case of ribs of main beams the nominal maximum size of
coarse aggregate should usually be restricted to 5 mm less than the minimum clear distance between the
main bars, or 5 mm less than the minimum cover to the reinforcement whichever is smaller.
2.9 Where the reinforcement is widely spaced as in solid slabs, limitations of size of the aggregate may not be
important and the nominal maximum size may sometimes be as greater than the minimum cover.
2.10 Admixture may used in concrete only with approval of Engineer-in-charge based upon the evidence that with
the passage of time, neither the compressive strength of concrete is reduced nor are other requisite qualities
of concrete and steel impaired by the use of such admixtures.
3.0 Workmanship:
3.1 Proportioning: Proportioning shall be done by volume, except cement which shall be measured in terms of
bags of 50 Kg. weight. The volume of one such bag being taken as 0.0342 Cu. Meter. Boxes of suitable sizes
shall be used for measuring sand aggregate. The size of the boxes (internal) shall be 35 cms x 25 cms. and
40 cms deep. White measuring the aggregate and sand, the box shall be filled without shaking ramming or
hammering. The proportioning of sand shall be on the basis of its dry volume and in case of damp sand,
allowances for bulkage shall be made.
3.2.1 For all work, concrete shall be mixed in a mechanical mixer which along with other accessories shall be kept in
first class working condition and so maintained throughout the construction. Measured quantity of aggregate,
sand, cement required for each batch shall be poured into the drum of the mechanical mixer while it is
continuously running. After about half a minute of dry mixing, measured quantity of water required for each
batch of concrete mix shall be added gradually and mixing continued for another one and half a minute. Mixing
shall be continued till materials are uniformly distributed and uniform color of the entire mass is obtained and
each individual particle of the coarse aggregate shows complete coating of mortar containing its proportionate
amount of cement. In no case shall the mixing be done for less than 2 minutes after all ingredients have been
put into the mixer.
3.2.2 When hand mixing is permitted by the Engineer-in-charge for small jobs or for certain other reasons, it shall be
done on the smooth watertight platform large enough to allow efficient turning over the ingredients of concrete
before and after adding water. Mixing platform shall be so arranged that no foreign material gets mixed with
concrete nor does the mixing water flow out. Cement in required number of bags shall be placed in a uniform
layer on top of the measured quantity of fine and coarse aggregate, which shall also be spread in a layer of
uniform thickness on the mixing platform. Dry coarse and fine aggregate and cement shall then be mixed
thoroughly by turning over to get a mixture to uniform color. Specified quantity of water shall then be added
gradually through a rose-can and the mass turned over till a mix of required consistency is obtained. In hand
mixing quantity of cement shall be increased by 10 percent above that specified.
3.2.3 Mixers which have been out of use for more than 30 minutes shall be thoroughly cleaned before putting in a
new batch. Unless otherwise agreed to by the Engineer-in-charge the first batch of concrete from the mixture
shall contain only two thirds of normal quantity of coarse aggregate. Mixing plant shall be thoroughly cleaned
before changing from one type of cement to another.
3.3 Consistency :
3.3.1 The degree of consistency which shall depend upon the nature of the work and methods of vibration of
concrete, shall be determined by regular slump tests in accordance with I.S. 1199-1959. The slump of 10mm
to 25mm. shall be adopted when vibrators are used and 80mm when vibrators are not used.
3.4 Inspection:
3.4.1 Contractor shall give the Engineer-in-charge due notice before placing any concrete in the forms to permit him
to inspect and accept the false work and forms as to their strength, alignment, and general fitness but such
inspection shall not relieve the contractor of his responsibility for the safety of men, machinery, materials and
for results obtained. Immediately before concreting, all forms shall be thoroughly cleaned.
3.4.2 Centering design and its erection shall be got approved from the Engineer-in-charge. One carpenter with
helper shall invariably be kept present throughout the period of concreting. Movement of labour and other
persons shall be totally prohibited for reinforcement laid in position. for access to different parts, suitable
mobile platforms shall be provided so that steel reinforcement in position is not disturbed. For ensuring proper
cover, mortar blocks of suitable size shall be provided so that steel reinforcement in position is not disturbed.
For ensuring proper cover, mortar blocks of suitable size shall be cast and tied to the reinforcement. Timber
kapachi or metal pieces shall not be used for this purpose.
3.5 Transporting and laying:
3.5.1 The method of transporting and placing concrete shall be as approved. Concrete shall be so transported and
placed that no contemination, segregation or loss of its constituent material takes place.
All form wok shall be cleaned and made free from standing water, dust, show or ice immediately before
placing of concrete.
No concrete shall be placed in any part of the structure until the approval of the Engineer-in-charge has been
3.5.2 Concreting shall proceed continuously over the area between construction joints. Fresh concrete shall not be
placed against concrete which has been in position for more than 30 minutes unless a proper construction
joint is formed. Concrete shall compacted in its final position within 30 minutes of its discharge from the mixer.
Except where otherwise agreed to by the Engineer-in-charge concrete shall be deposited n horizontal layers to
a compacted depth of not more than 0.45 meter when internal vibrators are used and not exceeding
meter in all other cases.
3.5.3 Unless otherwise agreed to by the Engineer-in-charge, concrete shall not be dropped into place from a height
exceeding 2 meters. When trunking or chutes are used they shall be kept close and used in such a way as to
avoid segregation. When concreting has to be resumed on a surface which has hardened, it shall be
roughened, swept clean, thoroughly wetted and covered with a 13 mm thick layer of mortar composed of
cement and sand in the same ratio as in the concrete mix itself. This 13 mm layer of mortar shall be freshly
mixed and placed immediately before placing of new concrete. Where concrete has not fully hardened, all
laitance shall be removed by scrubbing the wet surface with wire or bristle brushes, care being taken to avoid
dislodgment of any particles of coarse aggregate. The surface shall then be thoroughly wetted, all free water
removed and then coated with neat cement grout. The first layer of concrete to be placed on this surface shall
not exceed 150 mm in thickness and shall be well rammed against old work particular attention being given to
corners and close spots.
3.5.4 All concrete shall be compacted to produce a dense homogeneous mass with the assistance of vibrators,
unless, otherwise permitted by the Engineer-in-charge for exceptional cases, such as concreting under water,
where vibrators cannot be used. Sufficient vibrators in serviceable condition shall be kept at site so that spare
equipment is always available in the event of breakdowns.
Concrete shall be judged to be compacted when the mortar fills the spaces between the coarse aggregate and
begins to cream up to form an even surface. Compaction shall be completed before the initial setting starts i.e.
within 30 minutes of addition of water to dry mixture. During compaction, it shall be observed that needle
vibrators are not applied on reinforcement which is likely to destroy the bond between concrete and
3.6 Curing: Immediately after compaction, concrete shall be protected from weather including rain, running water,
shocks, vibration, traffic, rapid temperature changes, frost and drying out process. It shall be covered with wet
sacking, hassain or other similar absorbant material approved, soon after the initial set and shall be kept
continuously wet for a period of not less than 14 days from the date of placement. Masonary work over
foundation concrete may be started after 48 hours of its laying but curing of concrete shall be continued for a
minimum period of 14 days.
3.7 Sampling and Testing of concrete:
3.7.1 Samples from fresh concrete shall be taken as per I.S. 1199-1959 and cubes shall be made, cured and tested
at 7 days or 28 days as per requirements in accordance with I.S. 516-1959. A random sampling procedure
shall be adopted to ensure that each concrete batch shall have a reasonable chance of being tested i.e. the
sampling should be spread over the entire period of concreting and cover all mixing units. The minimum
frequency of sampling of concrete of each grade shall be in accordance with following:
Quantity of concrete No. of Quantity of concrete in No. of samples
in the work samples the works
51 and above 4+ one additional for each additional 50 M. or part thereof.
NOTE : At least one sample shall be taken from each shift. Ten test specimens shall be made from each sample, five
for testing at 7 days and the remaining five at 28 days. The samples of concrete shall be taken on each day of
the concreting as per above frequency. The number of specimens may be suitably increased as deemed
necessary by the Engineer-in-charge when procedure of tests given above reveals a poor quality of concrete
and in other special cases.
3.7.2 The average strength of the group of cubes cast for each day shall not be less than the specified cube
strength of 150 Kg/Cm at 28 days. 20% of the cubes cast for each day may have value less than the specified
strength provided the lowest value is not less than 85% of the specified strength. If the concrete made in
accordance with the proportions given for a particular grade, does not yield the specified strength; such
concrete shall be classified as belonging to the appropriate lower grade. Concrete made in accordance with
the proportions given for a particular grade shall not, however, be placed in a higher grade on the ground that
the test strength are higher than the minimum specified.
3.8.1 The Engineer-in-charge shall be informed in advance by the contractor of his intention to strike the form work.
While fixing the time for removal of form work, due consideration shall be given to local conditions, character
for the structure, the weather and other condition that influence the setting of concrete and of the materials
used in the mix. In normal circumstances (generally where temperatures are above 20 C) and where ordinary
concrete is used, forms may be struck after expiry of periods specified in item No 9.1(A) for respective item of
3.8.2 All form work shall be removed without causing any shock or vibration as would damage the concrete. Before
the soffit and struts are removed, the concrete surface shall be exposed, where necessary in order to
ascertain that the concrete has sufficiently hardened. Centering shall be gradually and uniformly lowered in
such manner as to permit the concrete to take stresses due to its own weight uniformly and gradually. Where
internal metal ties are permitted, the or their removable parts shall be extracted without causing any damage
to the concrete and remaining holes filled with mortar. No permanently embedded metal part shall have less
than 25 mm cover to the finished concrete surface. Where it is intended to re-use the form work, it shall be
cleaned and made good to the satisfaction of the Engineer-in-charge. After removal of form work and
shuttering, the Executive Engineer shall inspect the work and satisfy by random checks that concrete
produced is of good quality.
3.8.3 Immediately after the removal of forms, all exposed bolts etc., passing through the cement concrete member
and used for shuttering or any other purpose shall be cut inside the cement concrete member to a depth of at
least 25 mm below the surface of the concrete and the resulting holes be filled by cement mortar. All fine
caused by form joints, all cavities produced by the removal of form ties and all other holes and depressions
honeycomb spots, broken edges or corners and other defects shall be thoroughly cleaned, saturated with
water and carefully pointed and rendered true with mortar of cement and fine aggregate mixed in the
proportions used in the grade of concrete that is being finished and of as dry consistency as is possible to use.
Considerable pressure shall be applied in filling and pointing to ensure thorough filling in all voids. Surfaces
which are pointed shall be kept most for a period of 25 hours.
If rock pockets/honeycombs in the opinion of the Engineer-in-charge are of such an extent or character as to
effect the strength of the structure materially or to endanger the life of the steel reinforcement, he may declare
the concrete defective and require the removal and replacement of the portion of the structure affected.
4.0 Mode of measurement and payment:
4.1 The consolidated cubical contents of concrete work as specified in item shall be measured. The concrete laid
in excess of section shown on drawings or as directed shall not be measured. No deduction shall be made for
(a) Ends of dis-similar materials such as joints, beams, posts, girders, rafters, purline trusses, corbels and steps
etc. up to 500 Sq. Cm. in section.
(b) Opening up to 0.1 Sq. M.
4.2 The rate includes cost of all materials, labour, tools and plant required for mixing, placing in position, vibrating
and compacting, finishing, as directed, curing and all other incidental expenses for producing concrete of
specified strength. The rate excludes the cost of form work.
4.3 The rate shall be for a unit of one cubic meter.
5.4.1 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) and curing complete excluding cost of form work and reinforcement for reinforced concrete work
(A) Foundation footing, base of columns and mass (B) Slabs, landings, shelves, balconies, internals beams
girders and cantilever up to floor two level (C) Columns, pillars, posts and struts up to floor two level (D)
Staircase up to floor two level (E) Vertical and horizontal fins up to floor two level.
1.0 Materials & Workmanship
1.1 The relevant specification of item No. 5.3.13 shall be followed except that the work shall be carried out for
reinforced concrete work for work as specified in item 1.2. In addition, the following stipulations shall be
(a) The bars shall be kept in position by the following methods:
(i) In case of beam and slab construction, sufficient number of precast cover blocks in cement mortar 1:2 (1
cement : 2 coarse sand) about 4 cms x 4 cms section and of thickness equal to the specified cover shall be
placed between the bars and shuttering as to secure and maintain the requisite cover of concrete over the
In case of cantilevered or doubly reinforce beams of slabs, the main reinforcing bars shall be held in position
by introducing chain spacers or supports bars at 1.0 to 1.2 meters centers.
(ii) In case of columns walls, the vertical bars shall be kept in position by means of timber temphtes with slotes
accurately out in them. The temphtes shall be removed after concreting has been done below it. The bars may
also be suitably tied by means of annealed steel wires to the shuttering to maintain their position during
1.2 All bars projecting from pillars, columns beams, slabs etc., to which other bars and concrete are to be attached
or bounced to later on, shall be protected with a coat of thin neat cement grout, if the bars are not likely to be
incorporated with succeeding mass of concrete within the following 10 days. This coat of thin neat cement
shall be removed before concreting.
2.0 Mode of measurement and payment:
2.1 Relevant specifications of item No. 5.3.13 shall be followed.
2.2 The volume occupied by reinforcement shall not be deducted from R.C.C. work.
2.3 The rate shall be for a unit of one cubic meter.
Providing and laying controlled cement concrete
M.150 for curing complete excluding cost of
formwork and reinforcement for reinforced concrete work in (A) Foundations, footings,Base of
columns and Mass concrete
Providing and laying in position Ready Mixed M-150 grade concrete for reinforced cement conctere work, using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to
site of work intransit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix
design of specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer
to site of laying, excluding the cost of centering shuttering finishing and reinforcement including cost of
admixtures in recommended proportions as per IS:9103 to accelerate/ retard setting of concrete, improve work
ability without impairing strength and durability as per direction of theEngineer-in-charge. Without Fly Ash (Min
cement level as per latest IS456 shall be maintained) (Cement level 320 kg )The earth obtained from excavation
shall be filled in layers not exceeding 20 cms. in depth and water thoroughly after each layer and shall be
properly consolidated with rammers so that no hollow voids remain there. In general the work shall be carried
out in the best manner so that no hollow voids remain after work. Workmanship in general confirm to C –2.
Providing and laying in position Ready Mixed M-150 grade concrete for reinforced cement conctere work, using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work intransit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended
proportions as per IS:9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and
durability as per direction of theEngineer-in-charge. Without Fly Ash (Min cement level as per latest IS456 shall be
maintained) (Cement level 320 kg )The earth obtained from excavation shall be filled in layers not exceeding 20 cms. in
depth and water thoroughly after each layer and shall be properly consolidated with rammers so that no hollow voids
remain there. In general the work shall be carried out in the best manner so that no hollow voids remain after work.
Workmanship in general confirm to C –2.
Mode of Measurement shall be on cubic meter basis.
Providing and laying in position Ready Mixed M-200 grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work intransit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and
reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/ retard
setting of concrete, improve work ability without impairing strength and durability as per direction of
theEngineer-in-charge. Without Fly Ash (Min cement level as per latest IS456 shall be maintained) (Cement
Providing and laying in position Ready Mixed M-200 grade concrete for reinforced cement conctere work, using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work intransit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended
proportions as per IS:9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and
durability as per direction of theEngineer-in-charge. Without Fly Ash (Min cement level as per latest IS456 shall be
maintained) (Cement level 400 kg )
Mode of Measurement shall be on cubic meter basis.
Providing and laying controlled cement concrete M.200for curing complete excluding cost of formwork and
reinforcement for reinforced concrete work in (A) Foundations, footings,Base of columns and Mass concrete.
Walls, from top of foundation level upto floor two level
Slabs,landing,shelves,Balconies Lintels, Beams, Girders and Cantilever upto
floor two level.
Columns, Pillars posts and struts upto floor two level.
Staircases excluding landing upto floor two level
Vertical and Horizontial its upto floor two level.
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work,
using cement content as per approved Design Mix manufactured in fully automatic batching plant and
transported to site of work intransit mixer for a lead up to 10 kms having continuous agitated mixer,
manufactured as per mix design of specified grade for reinforced cement concrete work including pumping of
R.M.C. from transit mixer to site of laying, excluding the cost of centering shuttering finishing and
reinforcement including cost of admixtures in recommended proportions as per IS:9103 to accelerate/ retard
setting of concrete, improve work ability without impairing strength and durability as per direction of
theEngineer-in-charge. Without Fly Ash (Min cement level as per latest IS456 shall be maintained) (Cement
Providing and laying in position Ready Mixed M-250 grade concrete for reinforced cement conctere work, using
cement content as per approved Design Mix manufactured in fully automatic batching plant and transported to site of
work intransit mixer for a lead up to 10 kms having continuous agitated mixer, manufactured as per mix design of
specified grade for reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of laying,
excluding the cost of centering shuttering finishing and reinforcement including cost of admixtures in recommended
proportions as per IS:9103 to accelerate/ retard setting of concrete, improve work ability without impairing strength and
durability as per direction of theEngineer-in-charge. Without Fly Ash (Min cement level as per latest IS456 shall be
maintained) (Cement level 450 kg )
Mode of Measurement shall be on cubic meter basis.
Providing and laying controlled cement concrete M.250 and curing complete excluding the cost of formwork and
reinforcement for reinforced concrete work
Providing and laying controlled cement concrete M.250 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete work
Foundations, footings, Base of columns and Mass concrete.
Walls, from top of foundation
level upto floor two leve
Slabs,landing,shelves,Balconies, Lintels, Beams,
Girders and Cantilever upto floor two level.
Columns, Pillars posts and
struts, upto floor two level.
Providing and laying in position Ready Mixed M-300 grade concrete for reinforced cement
conctere work , using cement content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of
laying, excluding the cost of centering shuttering finishing and reinforcement including
cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability as per
direction of the Engineer - in - charge. Without Fly Ash (Min cement level as per latest IS
shall be maintained) (Cement level 475 kg )
Providing and laying in position Ready Mixed M-350 grade concrete for reinforced cement
conctere work , using cement content as per approved Design Mix manufactured in fully
automatic batching plant and transported to site of work in transit mixer for a lead up to 10 kms
having continuous agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit mixer to site of
laying, excluding the cost of centering shuttering finishing and reinforcement including
cost of admixtures in recommended proportions as per IS: 9103 to accelerate/ retard setting of
concrete, improve workability without impairing strength and durability as per
direction of the Engineer - in - charge. Without Fly Ash(Min cement level as per latest IS 456shall be
maintained) (Cement level 500 kg )
Materials & Workmanship :
Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6. Grit shall conform to M-8.
Coarse aggregate shall conform M-12 B.
The proportioning of cement and aggregates shall be done by weight and necessary precautions shall be taken in the
production to ensure that the required work cube strength is attained and maintained. The controlled concrete shall be
in grades of M-100, M-150, M-200, M-250, M-300, M-350, M-400, with prefix controlled added to it. The letter ‘M’ refers
to mix and numbers specify 28 days works cube compressive strength of 150 mm cubes of the mix expressed in Kg. /
The proportion of cement, sand and coarse aggregates shall be determined by weight. the weight batch machine shall
be used for maintaining proper control over the proportion of aggregates as per mix design.
The strength requirements of different grades of concrete shall be as under:
Grade of Concrete Compressive strength of 15 cms 28 cubes in Kg./Cmt. at with I.S.
days conducted in accordance 516-1959
Preliminary test Work test
In all cases, the 28 days compressive strength specified in above table above be the criteria for acceptance or
rejection of the concrete
Where the strength of a concrete mix as indicated by tests, lies in between the strength of any two grades specified in
the above table such concrete shall be classified in for all purposes as concrete belonging to the lower of the two
grades between which its strength lies.
The proportions for ingredients chosen shall be such that concrete has adequate workability for conditions prevailing
on the work in question and can be properly compacted with means available except where it can be shown to the
satisfaction of the Engineer-in-charge, that the supply of properly graded aggregate of uniform quality can be
maintained till the completion of work. Grading of aggregate shall be controlled by obtaining the coarse aggregates, in
different sizes and being in them in the right proportions as required. Aggregate of different sizes shall be stocked in
separate stock piles. The required quantity of material shall be stock piled several hours, preferably a day before use.
The grading of coarse and fine aggregate shall be checked as frequently as possible, the frequency for a given job
being determined by the Engineer-in-charge to ensure that the suppliers are maintaining the uniform grading as
approved for samples used in the preliminary tests.
In proportioning concrete, the quantity of both cement and aggregate shall be determined by weight. Where the weight
of cement is determined by accepting the maker’s weight per bag a reasonable number of bags shall be weighted
separately to check the net weight. Water shall either be measured by volume in calibrated tanks or weighed. All
measuring equipments shall be maintained in clean and serviceable condition. Their accuracy shall be periodically
In is most important to keep the specified water cement ratio constant and at its correct value. To this end, moisture
content in both fine and coarse aggregates shall be determined by the Engineer-in-charge, according to the weather
conditions. The amount of mixing water shall then be adjusted to compensate for variations in the moisture content.
For the determination of moisture content in the aggregates, I.S. 2389(Part III) shall be referred to. Suitable
adjustments shall also be made in the weights of aggregates due to variation in their moisture content. Minimum
quantity of cement to be used in concrete shall not be less than 220 Kgs./M 3 in plain concrete and not less than
Kg/M3 in reinforced concrete.
Mode of measurement and payment:
The consolidated cubical contents of concrete work as specified in item shall be measured. The concrete laid in
excess of section shown on drawings or as directed shall not be measured. No deduction shall be made for –
Ends of dis-similar materials such as joints, beams, posts, girders, rafters, purline trusses, corbels and steps etc. up to
500 Sq. Cm. in section.
Opening up to 0.1 Sq. M.
The rate includes cost of all materials, labour, tools and plant required for mixing, placing in position, vibrating and
compacting, finishing, as directed, curing and all other incidental expenses for producing concrete of specified
strength. The rate excludes the cost of form work.
Providing and Laying ordinary cement concrete 1:2:4 (1-Cement 2-coarsesand: 4-graded stone aggregates
mm nominal size) and finishing smooth with curing etc. complete including the cost of form work but
excluding the cost of reinforsement for R.C.C work in (iv) Slabs having more than 13 cm and upto
Providing and Laying ordinary cement concrete 1:2:4 (1-Cement 2-coarsesand: 4-graded stone aggregates 20 mm
nominal size) and finishing smooth with curing etc. complete including the cost of form work but excluding the cost of
reinforsement for R.C.C work in (iv) Slabs having more than 13 cm and upto 15 cm.thickness
Mode of Measurement shall be on cubic meter basis.
Providing and Laying ordinary cement concrete 1:2:4 (1-Cement 2-coarsesand: 4-graded stone
aggregates 20 mm nominal size) and finishing smooth with curing etc. complete including the cost of
form work but excluding the cost of reinforsement for R.C.C work in (iv) Slabs having more than 8 cm and
upto 10 cm.thickness
Mode of Measurement shall be on cubic meter basis.
Providing and laying ordinary cement concrete 1:2:4 (1- Cement 2- coarse sand : 4- graded stone aggregates
20 mm nominal size) for R.C.C lintel including finishing smooth with,curing etc. complete including the cost of
formwork but excluding the cost of reinforcement.
Brick work using common burnt clay building bricks having crushing strength not less than 35kg./Sq.Cm.in
foundation and plinth in Cement Mortar1:6 (1- Cement :6 - fine sand) (B) Conventional (upto 10 ton)
Materials: Water shall conform to M-1 Cement shall conform to M-3 Sand shall conform to M-6. Brick
shall conform to M-15 Cement mortar shall conform to M-11.
The proportion of the cement mortar shall be 1:6 (1 cement : 5 fine sand) by volume.
Wetting of bricks:
The bricks required for masonry shall be thoroughly wetted with clean water for about two hours before use
or as directed. The cessation of bubbles, when the bricks are wetted with water is an indication of through
wetting of bricks.
Bricks shall be laid in English bond unless directed otherwise. Half or cut bricks shall not be used except
when necessary to complete to bond; closer in such case shall be cut to required size and used near the ends
A layer of mortar shall be spread on full width for suitable length of the lower course. Each brick shall first
be properly bedded and set home by gently tapping with handle of trowel or wooden mallet. It side face shall
be flushed with mortar before the next brick is laid and pressed against it. On copletion of course, the vertical
joints shall be fully filled form the top with mortar.
The walls shall be taken up truly in plumb. All courses shall be laid truly horizontal and all vertical joint
shall be truly vertical. Vertical joints in alternate course shall generally be directly one over the other. The
thickness of brick course shall be kept uniform.
The brick shall be laid with frog upwards. A set of tools comprising of wooden straight edges, mason’s sprit
level, square half meter rub, and pins, string and plumb shall be kept on the site of work for frequent
checking during the progress of work.
Both the faces of walls of thickness greater than 23 cms shall be kept in proper place. All the connected brick
work shall be kept not more than one meter over the rest of the work. Where this is not possible, the work
shall be raked back according to bond (and not left toothed) at an angle not steeper than 45 degrees.
All fixtures, pipes, outlets of water, hold fasts of doors and windows etc. which are required to be built in
wall shall be embedded in cement mortar.
Bricks shall be so laid that all joints are quite flush with mortar. Thickness of joins shall not exceed 12 mm.
The face joints shall be raked out as directed by taking tools daily during the progress of work, when the
mortar is still green so as to provide key for plaster or pointing to done.
The face of brick shall be cleaned the very day on which the brick work is laid and all mortar dropping
Green work shall be protected from rain suitably. Masonry work shall be kept moist on all the faces for a
period seven days. The top of masonry work shall be kept well wetted at the close of the day
Preparation of foundation bed:
If the foundation is to be laid directly on the excavated bed, the bed shall be leveled, cleared of all loose
materials, cleaned and wetted before starting masonry. If masonry is to be laid on concrete footing, the top of
concrete shall be cleaned and moistened. The contractor shall obtain the engineer'’ approval for the
foundation bed, before foundation masonry is started. When puccas flooring is to be provided flush with the
top to plinth, the inside plinth offset shall be kept lower than the outside plinth top by the thickness of the
Mode of measurements and payment:
The measurements of this item shall be taken for the brick masonry fully completed in foundation up to
plinth. The limiting dimensions not exceeding those shown on the plans or as directed shall be final.
Battered, tapered and curved portions shall be measured net.
No deduction shall be made from the quantity of brick work nor any extra payment made for embedding in
masonry or making holes in respect of following items:
Ends of joints, beams, posts, girders, rafters, purlins, trusses, corbel steps etc. where cross sectional area does
not exceed 500 Sq. cm.
Opening not exceeding 1000 Sq. cm.
Wall plates and bed plates, bearing of slabs, chhajas an the like whose thickness does not exceed 10 Cms.
and the bearing does not extend to the full thickness of wall.
Drainage holes, and recesses for cement concrete blocks to embed hold fasts for doors, windows etc.
Iron fixtures, pipes up to 300 mm dia hold fasts and doors and windows built into masonry and pipes etc. for
concealed wiring.
Forming chases of section not exceeding 350 Sq. Cm. in masonry.
Apertures for fire places shall not be deducted nor shall extra labour required to make splaying of jambs,
throating and making Arches over the aperture be paid for separately.
The rate shall be for a unit of one cubic meter.
Brick work using common burnt clay building bricks having crushing strength not less than
35kg./Sq.Cm.in foundation and plinth in Cement Mortar1:6 (1-Cement :6 - fine sand) B)
Extra for brickwork in super structure above plinth level upto floor two level (B) Conventional
Materials: Water shall conform to M-1 Cement shall conform to M-3 Sand shall conform to M-6. Brick shall conform to
M-15 Cement mortar shall conform to M-11.
The proportion of the cement mortar shall be 1:6 (1 cement : 5 fine sand) by volume.
Wetting of bricks:
The bricks required for masonry shall be thoroughly wetted with clean water for about two hours before use or as
directed. The cessation of bubbles, when the bricks are wetted with water is an indication of through wetting of bricks.
Bricks shall be laid in English bond unless directed otherwise. Half or cut bricks shall not be used except when
necessary to complete to bond; closer in such case shall be cut to required size and used near the ends of walls.
A layer of mortar shall be spread on full width for suitable length of the lower course. Each brick shall first be properly
bedded and set home by gently tapping with handle of trowel or wooden mallet. It side face shall be flushed with
mortar before the next brick is laid and pressed against it. On copletion of course, the vertical joints shall be fully filled
form the top with mortar.
The walls shall be taken up truly in plumb. All courses shall be laid truly horizontal and all vertical joint shall be truly
vertical. Vertical joints in alternate course shall generally be directly one over the other. The thickness of brick course
shall be kept uniform.
The brick shall be laid with frog upwards. A set of tools comprising of wooden straight edges, mason’s sprit level,
square half meter rub, and pins, string and plumb shall be kept on the site of work for frequent checking during the
progress of work.
Both the faces of walls of thickness greater than 23 cms shall be kept in proper place. All the connected brick work shall
be kept not more than one meter over the rest of the work. Where this is not possible, the work shall be raked back
according to bond (and not left toothed) at an angle not steeper than 45 degrees.
All fixtures, pipes, outlets of water, hold fasts of doors and windows etc. which are required to be built in wall shall be
embedded in cement mortar.
Bricks shall be so laid that all joints are quite flush with mortar. Thickness of joins shall not exceed 12 mm. The face
joints shall be raked out as directed by taking tools daily during the progress of work, when the mortar is still green so
as to provide key for plaster or pointing to done.
The face of brick shall be cleaned the very day on which the brick work is laid and all mortar dropping removed.
Green work shall be protected from rain suitably. Masonry work shall be kept moist on all the faces for a period seven
days. The top of masonry work shall be kept well wetted at the close of the day
Preparation of foundation bed:
If the foundation is to be laid directly on the excavated bed, the bed shall be leveled, cleared of all loose materials,
cleaned and wetted before starting masonry. If masonry is to be laid on concrete footing, the top of concrete shall be
cleaned and moistened. The contractor shall obtain the engineer'’ approval for the foundation bed, before foundation
masonry is started. When puccas flooring is to be provided flush with the top to plinth, the inside plinth offset shall be
kept lower than the outside plinth top by the thickness of the flooring.
Mode of measurements and payment:
The measurements of this item shall be taken for the brick masonry fully completed in foundation up to plinth. The
limiting dimensions not exceeding those shown on the plans or as directed shall be final. Battered, tapered and curved
portions shall be measured net.
No deduction shall be made from the quantity of brick work nor any extra payment made for embedding in masonry or
making holes in respect of following items:
Ends of joints, beams, posts, girders, rafters, purlins, trusses, corbel steps etc. where cross sectional area does not
exceed 500 Sq. cm.
Opening not exceeding 1000 Sq. cm.
Wall plates and bed plates, bearing of slabs, chhajas an the like whose thickness does not exceed 10 Cms. and the
bearing does not extend to the full thickness of wall.
Drainage holes, and recesses for cement concrete blocks to embed hold fasts for doors, windows etc.
Iron fixtures, pipes up to 300 mm dia hold fasts and doors and windows built into masonry and pipes etc. for concealed
Forming chases of section not exceeding 350 Sq. Cm. in masonry.
Apertures for fire places shall not be deducted nor shall extra labour required to make splaying of jambs, throating and
making Arches over the aperture be paid for separately.
The rate shall be for a unit of one cubic meter.
Half brick masonry in common brunt clay building bricks having crushing strength not less than
Kg/Sq.Cm. in Cement mortar 1:5 ( 1-Cement : 5 coarse sand ) in foundation and Plinth
conventional brickwork (up to 10 ton)
The rate shall be for a unit of Sq. Mt.
Extra for half brick masonry in super structure above plinth level upto floor two level (B) conventional
Materials: Brick shall conform to M-15. Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform
to M-6. Cement mortar shall conform to M-11.
Relevant specifications of bricks, wetting and laying of bricks, joints, curing etc. shall conform to item No. 7 except the
brick work of half bricks shall be carried out.
Cement mortar used in masonry work shall be in proportion of 1 part of cement and 5 part of sand by volume.
All bricks shall be laid strecher wise, breaking joints with those in the upper and lower courses. The wall shall be taken
truly plumb. All courses shall be laid truly horizontal and all vertical joints shall be truly vertical. The bricks shall be laid
with frogs upwards. A set of masons tools shall be maintained on work as required for frequent checking.
Mode of measurement and payment:
The half brick masonry work in foundation and plinth shall be measured under this item, the limiting dimensions shall
not exceed those shown in the plan or as directed. Any work done extra over the specified dimensions shall be
The relevant specifications of item No. 7 shall be followed. The length shall be measured nearest to one Cm.
The rate shall be for a unit of Sq. Mt.
Providing and laying Pre cast Light weight concrete hollow core wall with hollow core concrete unit of
approved make & size of 92 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in
legth made from of controlled cement concrete M20 having cube compressive strength not less than 20 MP a
jointing with high strength & tensile adhesion non-shrink cementitious joint compound /P.U. Foam. (Plaster
Providing and laying Pre cast Light weight concrete hollow core wall with hollow core concrete unit of approved make
& size of 92 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth made from of
controlled cement concrete M20 having cube compressive strength not less than 20 MP a jointing with high strength &
tensile adhesion non-shrink cementitious joint compound /P.U. Foam. (Plaster not required)
The rate shall be for a unit of Sq. Mt.
Providing and laying Pre cast Light weight concrete hollow core wall with hollow core concrete unit of
approved make & size of 120 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in
legth made from of controlled cement concrete M20 having cube compressive strength not less than 20MP a
jointing with high strength & tensile adhesion non-shrink cementitious joint compound/ P.U.Foam. (Plaster
Providing and laying Pre cast Light weight concrete hollow core wall with hollow core concrete unit of approved make
& size of 120 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth made from of
controlled cement concrete M20 having cube compressive strength not less than 20MP a jointing with high strength &
tensile adhesion non-shrink cementitious joint compound/ P.U.Foam. (Plaster not required)
The rate shall be for a unit of Sq. Mt.
Providing and laying Pre cast Regular concrete hollow core wall with hollow core concrete unit of approved
make & size of 92 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth made
from of controlled cement concrete M35 having cube compressive strength not less than 35 MP a jointing with
high strength & tensile adhesion non-shrink cementitious joint compound/ P.U.Foam. (Plaster not required)
Providing and laying Pre cast Regular concrete hollow core wall with hollow core concrete unit of approved make &
size of 92 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth made from of
controlled cement concrete M35 having cube compressive strength not less than 35 MP a jointing with high strength &
tensile adhesion non-shrink cementitious joint compound/ P.U.Foam. (Plaster not required)
The rate shall be for a unit of Sq. Mt.
Providing and laying Precast Regular concrete hollow core wall with hollow core concrete unit of approved
make & size of 120 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth
made from of controlled cement concrete M35 having cube compressive strength not less than 35 MP a
jointing with high strength & tensile adhesion non-shrink cementitious joint compound /P.U.Foam. (Plaster
Providing and laying Precast Regular concrete hollow core wall with hollow core concrete unit of approved make &
size of 120 mm thick, 600 mm wide and 2400 mm/ 2600 mm/ 2850 mm/ 3000 mm/ 3300 mm in legth made from of
controlled cement concrete M35 having cube compressive strength not less than 35 MP a jointing with high strength &
tensile adhesion non-shrink cementitious joint compound /P.U.Foam. (Plaster not required)
The rate shall be for a unit of Sq. Mt.
Providing form work of ordinary timber planking so as to give a rough finish including centering shuttering,
strutting and propping etc. height of propping and centering below supporting floor to celling not exceeding
m. and removal of the same for in site reinforced concrete and plain concrete work in foundations, footing,
bases of columns, and mass concrete. ( up a to h)
The shuttering to be provided shall be of ordinary timber planks and shall conform to M-26.
The dimensions of scantlings and battens shall conform to the design. The strength of the wood shall not be less than
that assumed in the design.
The form work shall conform to the shape lines and dimension as shown on the plans and be so constructed as to
remain sufficiently rigid during the placing and compacting of the concrete. Adequate arrangements shall be made by
the contractor to safe guard against any settlement of the form work during the course of concreting and after
concreting. The form work of shuttering, centering, scaffolding bracing etc shall be as per design.
Cleaning & Treatment of forms:
All rubbish, particularly chippings shaving and saw dust shall be removed from the interior of the form before the
concrete is placed and the form work in contact with concrete shall be cleaned and thoroughly wetted or treated. The
surface shall be then coated with soap solution applied before concreting is done. Soap solution for the purpose shall
be prepared by dissolving yellow soap in water to get consistency of paint. Alternatively a coat of raw linseed oil or
form oil of approved manufacture may be applied in case steel shuttering is used. Soap solution or raw linseed oil shall
be applied after thoroughly cleaning the surface. Care shall be taken that the coating does not get on construction joint
surface and reinforcement bars.
Stripping time:
In normal circumstances and where ordinary cement is used forms may be struck after expiry of following periods:
Sides of walls columns and vertical faces of beam 24 to 48 hours.
Beams soffits (Props left under) 7 days.
Removal of props slabs
(i) Slabs spanning up to 4.5 m – 7 days (ii) Spanning over 4.5 mm 14 days
Removal of props to beams and arches
(i) Spanning up to 6 m – 14 days (ii) Spanning over 6 m 21 days
Procedure when removing the form work:
All form work shall be removed without such shock or vibration as would damage the reinforced concrete surface.
Before the soffits form work and struts are removed, the soffits and the concrete surface shall be exposed where
necessary in order to ascertain that the concrete has sufficiently hardened.
The centering to be provided shall be got approved. It shall be sufficiently strong to ensure absolute safely of the form
work and concrete work before, during and after pouring concrete. Watch should be kept to see that behavior of
centering and form work is satisfactory during concreting. Erection should also be such that it would allow removal of
forms in proper sequence without damaging either the concrete or the forms to be removed.
The props of centering shall be provided on firm foundation or base of sufficient strength to carry the loads without
any settlement.
The centering and form work shall be inspected and approved by the Engineer-in-charge before concreting. But this
will not relieve the contractor of his responsibility for strength, adequacy and safety of form work and centering. If there
is a failure of form work or centering, contractor shall be responsible for the damages to the work, injury to life and
damage to property.
All scaffolding, hoisting arrangements and ladders etc required for the facilitating of concreting shall be provided and
removed on completion work by contractor at his own expense. The scaffolding, hoisting arrangements and ladders
etc. shall be strong enough to with stand all live, dead and impact loads expected to act and shall be subject to the
approval of the Engineer-in-charge. However, contractor shall be solely responsible for the safety of the scaffolding,
hoisting arrangement, ladders, work and workman etc.
The scaffolding hoisting arrangements and ladders shall allow easy approach to the work spot and afford easy
The rate is applicable to all conditions of working and height up to 4 mts. The rate shall include the cost of materials
and labour for various operations involved such as:
Splayed edges, notching, allowance for overlaps and passing at angles, battens centering, shuttering propping,
bolting, nailing, wedging, easing, striking and removal.
Filleting to form stop chamfered edges or splayed external angles not exceeding 20 mm width to beams, columns and
Temporary openings in the forms for pouring concrete, if required, removing rubbish etc.
Dressing with oil to prevent adhesion of concrete with shuttering, and
Raking or circular cutting.
Rate shall be paid in Sq.m
Providing and fixing 35 mm thick shutters for Doors, windows and clear story windows including anodised
alluminium butt hinges with necessary screws.
(A) Indian Teak Wood (ii) Fully Glazed. (upto 10 ton)
(B) Indian Teak Wood (iii) Partly panelled and partly glazed. (upto 10 ton)
(C) Indian Teak Wood (iii) Partly panelled and partly glazed.
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing 35 mm thick shutters for Doors, windows and clear story windows including black
enamelled M.S.butt hinges with necessary screws..
(A) Indian teak wood. (i) Fully Panelled.(upto 10 ton)
(B) Indian teak wood. (ii) Fully Glazed.(upto 10 ton)
(C) Indian teak wood. (iii) Partly panelled and partly glazed. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing 35 mm thick panelled, glazed or panelled and glazed shutters for Doors windows and
clear story windows including anodised alluminium But hinges with necessary screws and indian teak wood
(A) Plywood sheet panels. (upto 10 ton)
(B) Particle board panels (upto 10 ton)
(C) Hard board panels. (upto 10 ton)
(D) Asbestos sheet panels. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing 25 mm thick shutters for cup boards etc. including black enamelled M.S. butt hinges with
necessary screws. (A) Indian teak wood. (i) Fully Panelled. (upto 10 ton)(a to b)
Providing and fixing 25 mm thick shutters for cup boards etc. including black enamelled M.S. butt hinges with
necessary screws. (A) Indian teak wood. (i) Fully Panelled. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing plain asbestos cement sheet 6 mm thick in partitions including fixing to fames with
screws etc, complete with 50 mm x 12 mm Deodar wood beading (Frames to be paid separately) (upto 10 ton)
Providing and fixing plain asbestos cement sheet 6 mm thick in partitions including fixing to fames with screws etc,
complete with 50 mm x 12 mm Deodar wood beading (Frames to be paid separately) (upto 10 ton)
Item should be executed as per site require ements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing in partitions 4 mm thick medium hard board of approved quality including fixing to fames
with screws etc complete with 50 mm x 12 mm teak wood beading (Frames to be paid separately) (upto 10 ton)
Providing and fixing in partitions 4 mm thick medium hard board of approved quality including fixing to fames with
screws etc complete with 50 mm x 12 mm teak wood beading (Frames to be paid separately) (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
25 mm thick wooden shelves supported on 40 x 40 mm x 6 mm T or L iron brackets fixed at suitable distances
but not exceeding 75 cm. apart with Mango wood or equivalent quality. (upto 10 ton)
25 mm thick wooden shelves supported on 40 x 40 mm x 6 mm T or L iron brackets fixed at suitable distances but not
exceeding 75 cm. apart with Mango wood or equivalent quality. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
40 mm thick wooden shelves supported on 40 x 40mm x 6 mm T or L iron brackets fixed at suitable distances
not exceeding 75cm. Apart with Mango wood or equivalent quality. (upto 10 ton)
40 mm thick wooden shelves supported on 40 x 40mm x 6 mm T or L iron brackets fixed at suitable distances not
exceeding 75cm. Apart with Mango wood or equivalent quality. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of
windows and clerestory windows.(upto10 ton)
Providing and fixing M.S. round or square bars with M.S. flats at required spacing in wooden frames of windows and
clerestory windows.(upto10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Kg.
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at
required spacings and frame alround, square or round bars with round headed bolts and nuts or by screws
(A) Plain Grill. (upto 10 ton)
Providing and fixing M.S. grills of required pattern to wooden frames of windows etc. with M.S. flats at required
spacings and frame alround, square or round bars with round headed bolts and nuts or by screws (A) Plain Grill. (upto
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Kg.
Providing and fixing glazed louvered glass windows and ventilators with teak wood frame 10 cm. x 7 cm. size
including 3 coats of oil painting to wood work etc.complete. (upto 10 ton)
Providing and fixing glazed louvered glass windows and ventilators with teak wood frame 10 cm. x 7 cm. size including
3 coats of oil pa inting to wood work etc.complete. (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing glazed louvered glass windows and ventilators with teak wood frame 10 cm.x7 cm. size
including 3 coats of oil painting to wood work etc.complete.with wooden louvers plank 12mm thick (upto
Providing and fixing glazed louvered glass windows and ventilators with teak wood frame 10 cm.x7 cm. size including
3 coats of oil painting to wood work etc.complete.with wooden louvers plank 12mm thick (upto 10 ton)
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing 35 mm thick shutters for Doors, windows and clere story windows including Indian teak
wood frames 10 cm x 7 cm. size including anodized alluminium fixtures and fastenings including primer coat
of approved quality and two coats of oil painting etc, complete.(ii) Fully Panelled.
Providing and fixing 35 mm thick shutters for Doors, windows and clere story windows including Indian teak wood
frames 10 cm x 7 cm. size including anodized alluminium fixtures and fastenings including primer coat of approved
quality and two coats of oil painting etc, complete.(ii) Fully Panelled.
Item should be executed as per site requirements amd instructions given by Engg-In-Charge.
Mode of payment shall be in Sq.m
Providing and fixing 35 mm thick shutters for Doors, windows and clere story windows including Indian teak
wood frames 10 cm x 7 cm. size including black enamelled iron oxidixed fixtures and fastenings including
primer coat of approved quality and two coats of oil painting etc, complete.(ii) Fully Panelled.
Wood for shutter shall conform to M-29 (2) Anodised aluminium butt hinges shall conform to M-43.
Workmanship: The item covers the requirement of preparation of shutters for doors, windows, clerestory windows,
their supply and fixing.
Panelled shutters shall be constructed in the form of timber frame work of styles and rails with panel, inserted of type
as specified in the detailed drawings. Panel shall be fixed by providing grooves in the style and rails. The styles and
rails shall be joined to each other by mortise and tenon joints at right angles.
All members of the shutters shall be straight without any warp or how and shall have smooth, well planed faces at right
angles to angles to each other.
The size of styles and rails shall be as per drawing or as directed. Styles and rails of shutters shall be made of one
Timber paneling:
Thickness of the panel shall be as specified in the item as shown in the drawing or as directed. If the panel is
made from more than one piece, the pieces shall be finished as shown in the detailed drawings and shall be joined
with continuous groove with specified size. The end pieces of the panel and the top and bottom of the panel shall be
provided with continuous tongue to frame into groove of the frame shutter. An air space of 1.5 mm shall be left in the
groove of frame shutter while fixing the panels in it.
The faces of the panel as well as various pieces of the panel shall be closely fitted to the size of the grooves.
Finishing of the corners of raised panel edges shall be done as shown in drawings or as directed.
Fixtures & Fastenings:
The rate shall include anodised aluminium butt hinges including fixing with iron screws. The size and number of hinges
shall b as per table given in annexure-1.
Mode of measurements and payment:
The rate for shutter includes cost of providing block and clear for keeping the shutter in open position as
The dimension of the shutter shall be measured clear size of the shutter in close position between the grooves
The rate shall be for a unit of one sq. meter.
(A) (II)Providing and fixing 35 mm thick fully glazed shutters for doors, windowsand clerestory windows
including anodised aluminium butt hinges with necessary streces, Indian Teak Wood.
Materials: Teak wood shall conform to M-29. Glass shall conform to M-38. Anodised aluminium butt hinges shall
conform to M-43.
The relevant specifications of item No. 10.12(A) I shall be followed except that the 35 mm thick shutters fully
glazed for doors, windows and clerelstory windows including aluminium butt hinges with necessary screws.
The glass panels shall be embodied in putty and secured to the rebate by wooden beds or mouldings shape
and size as approved with counter sunk screws of suitable size.
The glass panel shall be properly cut to fit the rebates of the frames and sashes fully with a light minus margin
of about 1.5 mm on all sides. Before glazing the frame shall be primed and prepared for painting so that wood may not
draw oil out of putty.
The rebate shall be putted to an extent to provide bedding all round the glass.
The glass shall then be bedded in putty and fitted to frames with wooden beads or mouldings as directed and
secured with counter sunk screw. The screw shall be spaced not more than 10 mm form each corner and not more
than 200 mm apart.
The size of the rebate in the frame and size and shape of beads or moulding shall be as per detailed drawings
or as directed. The beds or mouldings shall have mitered corners.
Mode of measurement and payment:
The relevant specifications of item No. 10.12(A)(I) I shall be followed.
The rate shall be for a unit of one sq. meter.
A) (III)Providing and fixing 35 mm thick partly panelled and partly glazedshutters, or doors, windows including
anodized aluminium butt hinges with necessary screws, Indian teak wood.
Materials: Teak wood shall conform to M-29. Glass shall conform to M-38. Anodised aluminium butt hinges shall
conform to M-43.
Workmanship: The relevant specifications of item No. 10.12(A) (I) and 10.12(A)(II) shall be followed except that the
35 mm thick shutters shall be partly panelled and partly glazed for door windows, clerestory windows etc., as per
Mode of measurement and payment:
The relevant specifications of item No. 10.12(A)(I) shall be followed. Teak wood incl.Brass fixtures and S.S.Hingers as
approved by Engg.in charge.
The rate shall be for a unit one sq. meter.
Providing and fixing 30 mm thick FACTORY MADE SOLID PANEL PVC DOOR SHUTTER consisting of frame
made out of M.S.tubes of 19 gauge thickness and size of 19 mm x 19 mm for stiles and 15 mm x 15 mm for to
p and bottom rails. M.S. frames hall have a coat of steel primers of approved make and manufacture, M.S.
frames hall be covered with 5 mm thick heat moulded PVC ‘C’ channel of size 30 x 50 mm formings tiles, and
mm thick 75 mm wide PVC sheets for to prail, lock rail and bottom rail on either side, and 10 mm (5 mm x 2)
thick, 20 mm wide cross PVC sheet as gap insert for to p rail and bottom rail, Panelling of 5 stiles and rails
with 30 mm wide x 5 mm thick PVC sheet beading on eighter side, and joined together with solventcement
adhesive,. An additional 5 mm thick PVC strip of 20 mm width is to be stculkon the interiors ide of the ‘c’
channel using PVC solventcement adhesive etc. complete as per direction of Engineer incharge,
manufacture’s specification and drawing.
PVC doors shall be provided with EZ-7 section doorframe as mentioned in the item description. The size of the door
shall be as per the drawing. The overall thickness of PVC doors shall be 24 mm. The aluminium fixtures and
fastenings shall be fixed to the shutters as directed by the engineer-in-charge.
The doors shall be of Sintex or any other approved make.
The holes for the hardware to be fitted shall be marked first on the door (for hinges, handle, tower bolt, aldrop etc.);
pilot holes of 3 mm shall be pre-drilled and then hinges is to be fitted on door. Screws shall not hammered on the
door but fastened by hand/electric screw driver.
Mode of measurement:
The rates of the PVC doors shall be on the basis of area in sq.mt. of PVC doors procured and fixed by the contractor.
No separate payment for the aluminum fixtures and fastenings shall be payable.
Providing and fixing in position collapsible shutters with vertical channels 20 x 10 x 2 mm braced with flat iron
diagonal 20 x 6 mm size with top and bottom rails T iron 40 x 40 x 6 mm with 38 mm dia steel pulleys complete
with bolts, units, locking arrangements, stoppers, handles, including a priming coat of red lead paint &
Materials: The collapsible steel gate shall conform to M-33.
T-rails shall be fixed to the floor and to the lintel at top by means of anchor bolts, embedded in cement concrete on
floor and lintel. The anchor bolts shall be placed approximately at 45 mm centers alternatively in the two flanges of the
T iron. In the bottom runner (T-iron) shall be embedded in the floor and proper groove shall be formed along the runner
for the purpose. The collapsible gate shall be fixed at the sites by fixing the end double channels in the T-Iron rail and
also by hold fasts bolted to the end double channel and fixed in the masonry of the side walls or the otherwise.
In case where the collapsible gate is not required to the lintel beams or slop above, a tee iron suitably
designed may be fixed at the top embedded in masonry and provided with necessary clamps and roller arrangement
All the adjoining work damaged while fixing of gate shall be made good to match the existing work without any
All the members of the collapsible gate including T-Iron shall be thoroughly cleaned of rust, scales, dust etc.
and given a priming coat of red lead before fixing them in position.
Mode of measurements and payment:
The collapsible gate shall be measured in sq. meter. The height of the gate shall be measured as the length of
double channels and breadth from outside to outside of the end fixed double channels in open position of the gate.
The rate includes providing handles, locking arrangements, stoppers etc.
The rate shall be for unit of one sq. meter.
Providing and fixing 1 mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6 mm
angle iron, 3.15 mm M.S.gusset plates at Junctions and corners 25 mm dia. pulley, 40x40x6 mm angle and T-
iron huide rail at top and bottom respactively with handles, stoppers and locking agangement etc, including
applying a priming coat of red lead paint. (upto 10 ton)
Providing and fixing 1 mm thick M.S. sheet sliding shutters with frame and diagonal braces of 40x40x6 mm
angle iron, 3.15 mm M.S.gusset plates at Junctions and corners 25 mm dia. pulley, 40x40x6 mm angle and T-iron
huide rail at top and bottom respactively with handles, stoppers and locking agangement etc, including applying a
priming coat of red lead paint. (upto 10 ton)
Item should be executed as per site conditions and instructions given by Engg-In-Charge.
The rate shall be for unit of one sq. meter.
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S.laths inter-locked
together through their entire length and jointed together at theends by end locks mounted on specially
designed pipe shaft with bracket plates, guide channels and arragements for inside and out side locking with
push-pull operation including the cost of hood cover and spring etc. complete. (A) Shutters having width
Providing and fixing rolling shutters of approved make made of 80 mm wide M.S.laths inter-locked together
through their entire length and jointed together at theends by end locks mounted on specially designed pipe shaft with
bracket plates, guide channels and arragements for inside and out side locking with push-pull operation including the
cost of hood cover and spring etc. complete. (A) Shutters having width below 3.5 M.
Item should be executed as per site conditions and instructions given by Engg-In-Charge.
The rate shall be for unit of one sq. meter.
Providing and fixing extruded aluminum window having extruded aluminum Colour Powder
Coatedsectionframemainoutersize127mmx38.10mmx1.35mm(ofJindalSectionno:2443,@Wt.1.384Kg/mt),horizo
ntal Four track member size122.20mm x31.75mm x1.10mm (ofJinda lSection no:8787,@ Wt.1.205Kg/ mt)
,vertical member of size122.20mm x31.75 mm x1.50 mm (ofJindal Section no:8935,@Wt.1.398Kg/mt) with
sliding shutters of horizontal member size 40mmx18mmx1.29 mm(ofJindal Section no:8949 @wt.of0.456
Kg/mt), vertical member of size 40mmx18mmx 1.29mm(ofJindal Section no:8947 @wt.of0.456Kg /mt/Section
8948,@Wt.0.457Kg/mt) with 5mmt hick transparent bronze colour tinted float glass with powder coated
aluminum fittings and fixturesandtransparentsiliconsealantglassfixingtoframeasperdetailsetccompletefor
Providing and fixing extruded aluminum window having extruded aluminum Colour Powder Coated section
frame main outer size127mmx38.10mmx1.35mm(ofJindalSectionno:2443,@Wt.1.384Kg/mt),horizontal Four track
member size122.20mm x31.75mm x1.10mm (ofJinda lSection no:8787,@ Wt.1.205Kg/ mt) ,vertical member of
size122.20mm x31.75 mm x1.50 mm (ofJindal Section no:8935,@Wt.1.398Kg/mt) with sliding shutters of horizontal
member size 40mmx18mmx1.29 mm(ofJindal Section no:8949 @wt.of0.456 Kg/mt), vertical member of size
40mmx18mmx 1.29mm(ofJindal Section no:8947 @wt.of0.456Kg /mt/Section 8948,@Wt.0.457Kg/mt) with 5mmt hick
transparent bronze colour tinted float glass with powder coated aluminum fittings and
fixturesandtransparentsiliconsealantglassfixingtoframeasperdetailsetccompletefor
Mode of measurement
Measurement will be given on the Square meter basis of actual area of the Aluminum section.
Providing and fixing window having extruded aluminum Colour anodized section frame main outer size
x 38.10 x 1.95 mm,@ Wt 1.094 Kg / Rmt, horizontal two track member size 61.85 mm x 31.75 mm x 1.20mm @
wt.of 0.695 Kg/mt, vertical member of size 61.85 mm x 31.75mm x 1.30 mm @ wt.of 0.659 Kg/mt with sliding
shutters of horizontal member size 40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, vertical member of size
40mm x 18mm x 1.29mm @ wt.of 0.456Kg/mt, @ Wt. 0.457 Kg/mt with 5 mm thick transparent bronze colour
tinted float glass with powder coated aluminum fittings
and fixtures and transparent silicon sealant glass fixing to frame as per details etc complete for window.
Providing & Fixing in position Alluminium vents with frame using approved anodised extruded alluminium
section as approved by Engg.in charge.(Jindal alluminium) units equivalent (Approved Rate) Frame section of
63.50 x 38.50 mm (wt.0.68 Kg/Rmt) incl.Providing & Installing 5 mm thick approved color Acrylic sheet of
standard quality etc.comp.
Providing & Fixing in position Alluminium vents with frame using approved anodised extruded alluminium
section as approved by Engg.in charge.(Jindal alluminium) units equivalent (Approved Rate) Frame section of 63.50 x
38.50 mm (wt.0.68 Kg/Rmt) incl.Providing & Installing 5 mm thick approved color Acrylic sheet of standard quality
Mode of measurement
Measurement will be given on the Smt. basis of actual area of the Aluminum section.
Providing and fixing standared extruded of alluminium section of size 63 mmx38.10 mmx1.2 mm (Jindal
Section:2434, @ Wt.0.643 Kg/mt) with colour anodized alluminium frame for ventilation with 5 mm thick
frosted glass as details etc complete for Ventilation
Providing and fixing standared extruded of alluminium section of size 63 mmx38.10 mmx1.2 mm (Jindal
Section:2434, @ Wt.0.643 Kg/mt) with colour anodized alluminium frame for ventilation with 5 mm thick frosted glass
as details etc complete for Ventilation
ITEM SHALL BE EXTUCUTED AS PER INSTRUCTION GIVEN BY ENGG. INCHARGE.
ITEM SHALL BE PAID IN SMT
Providing and fixing standared extruded of alluminium section of size 63.50 x 38.10 x 1.95mm,@ Wt 1.094Kg /
Rmt with colour Powder Coated alluminium frame with 5 mm thick transparent bronze colour tinted float glass
as details etc complete for Fix Partition
ITEM SHALL BE EXTUCUTED AS PER INSTRUCTION GIVEN BY ENGG. INCHARGE.
ITEM SHALL BE PAID IN SMT
Providing and laying 40 mm thick marble chips flooring rubbed and polished (I.E.terrazo) to granolithic finish
with under layer 30 mm thick cement concrete1:2:4 (1-Cement: 2-coarse sand: 4-graded stone aggregate
mm and down gauge) and to player 10 mm thick with white, black or white and blak marble cihps of required
sizes from 1 mm to 4 mm nominal size laid in cement marble powder mix 3:1 (3-Cement:1-Marble powder by
weight) in proportion of 4:7 (4-Cement: 7-marble chips by volume) (C) Medium Shade pigment with approx
50% white cement and 50% ordinary cement (In top layer only) (upto 10 ton)
Providing and laying 40 mm thick marble chips flooring rubbed and polished (I.E.terrazo) to granolithic finish
with under layer 30 mm thick cement concrete1:2:4 (1-Cement: 2-coarse sand: 4-graded stone aggregate 10 mm and
down gauge) and to player 10 mm thick with white, black or white and blak marble cihps of required sizes from 1 mm
to 4 mm nominal size laid in cement marble powder mix 3:1 (3-Cement:1-Marble powder by weight) in proportion of
4:7 (4-Cement: 7-marble chips by volume) (C) Medium Shade pigment with approx 50% white cement and 50%
ordinary cement (In top layer only) (upto 10 ton)
Item should be executed as per site conditions and instructions given by Engg-In-Charge.
The rate shall be for a unit Sq.m.
Providing and laying marble chips skirting (Terrazo) or dedo rubbed, and polished to Granolithic finish to
player 6 mm white, black or white and black marble chips of size from smallest to 4 mm nominal size laid in
cement marble powder mix 3:1 (3-Cement: 1 marble powder by weight) in proportion of 4:7 (4-cement marble
powder mix: 7-marble chips by volume) 20 mm thick with under 14 mm thick layer cement plaster 1:3 (1-
cement: 3-coarse sand) (C) Medium shade pigment with appox 50% white cement and 50% ordinary cement
(In top layer only) (upto 10 ton)
Providing and laying marble chips skirting (Terrazo) or dedo rubbed, and polished to Granolithic finish to
player 6 mm white, black or white and black marble chips of size from smallest to 4 mm nominal size laid in cement
marble powder mix 3:1 (3-Cement: 1 marble powder by weight) in proportion of 4:7 (4-cement marble powder mix: 7-
marble chips by volume) 20 mm thick with under 14 mm thick layer cement plaster 1:3 (1-cement: 3-coarse sand) (C)
Medium shade pigment with appox 50% white cement and 50% ordinary cement (In top layer only) (upto 10 ton)
Item should be executed as per site conditions and instructions given by Engg-In-Charge.
The rate shall be for a unit Sq.m.
Providing and laying white glazed tiles 6 mm thick in flooring treads of steps and landing laid on a bed of
mm thick cement mortar 1:3 (1- cement:3-coarses and) finishing with flush pointing in white cement. (upto
Workmanship : The work shall be carried out for skirting as dedo. Before fixing glazed tiles of shade and size as specified, the
surface shall be prepared by heavy scarping, making joints etc. to the required line, level and plumb. The surface shall be
thoroughly wetted before commencing the laying work. Thereafter about 10 mm. thick backing of cement mortar in specified
proportion shall be applied on the surface in true like and level generally as per specifications of plaster item.
Fixing : The black of each tile to be fixed shall be smeared with cement paste of matching colour and the glazed tiles shall then
be gently tapped against the surface, with a wooden mallet. The skirting shall be done only after the flooring is competed. Any
pipes coming out of the wall through the dedo or skirting shall only beat at the intersections of the horizontal and vertical joints.
The tiles shall not have staggered joints. The joints shall be true to entire line both ways and vertical joints shall be in line with
joints of flooring. Tiles shall be fixed as close as possible to the adjoining tiles and any difference in the thickness of the glazed
tiles shall be evened out in the cement paste so that all the tiles faces are set in conformly with one another. The skirting shall
project uniformly and not more than 6 mm. thickness beyond the finished surface above. Top of skirting of dedo shall be truly
horizontal. The rises of steps, skirting or dedo shall rest on top of treads of flooring wherever required. The tiles shall be cut
(sawn) and thin edges smoothened before use.
Curing : Curing shall be done for 7 days continuously.
Finishing : Skirting and dedo shall be hand polished to have an even smooth and shining surface. In case of skirting only 10 mm.
x 10 mm. grove shall be provided at the junction of cement plaster and cement tilesThe white glazed tiles shall be laid on cement
mortar bedding of 12 mm thick in C.M. 1 :3 . The mortar shall have sufficient plasticity for laying and there shall be no hard
lumps that would interfere with the evenness of bedding the base shall be cleared with well wetted. The mortar shall then be
spread in thickness not less than 10 mm at any place and average 12 mm thickness. The proportion of the cement mortar shall
be as specified in the item.
The tiles before laying shall be soaked in water for atleast two hours Neat Gracie cement grout at 3.3 Kg/Cement /Sq. mt. Of
honey like consistency shall be separated over the mortar bedding as directed. The edges of the tiles be smeared with neat
cement slurry. The tiles shall be well pressed and gently tapped with a wooden mallet till they are properly bedded and in level
with the adjoining tiles. There shall be no hollows in bed or joints. The joints between the tiles shall be as thin as possible in
straight line or as per pattern.
The tiles shall not have staggered joints. The joints shall be true to centre line both ways. The Nehni trap coming in the flooring
shall be so positioned that its grating shall replace only one tile as far as possible. Where full size tiles cannot be fixed, they shall
be cut (swan0 to be required size and the edges rubbed smooth to ensure straight and true joints. The joints shall be filled with
grey cement grout with wire brush of trowel to a depth of 5 mm. and loose material removed. White cement shall be used for
pointing the joints., After fixing the tile finally in an even the flooring shall be kept wet and allowed to nature undisturbed for
The surplus cement grout that may have come out of the joints shall be cleared off before it sets. Once the floor has set, it shall
be carefully washed, cleared by dilute acid and dried. Proper precaution and measures shall be taken to ensure that the tiles are
not damaged inany way till the completion of the construction.
Mode of measurement & payment
The work done shall be measured in sq. mt. For visible area of work done, The length and width of the flooring shall be
measured not between the faces of skirting or dedos or plastered face of wall as the case may be. The paving under dedo or
skirting shall not be measured. No deduction shall be made not extra paid for any opening in the floor of area upto 0.1 sq. mt.
Nothing extra shall be paid for laying the floors at different levels in the same rooms.
The rate shall be for a unit of one sq. metre.
Providing and laying Ceramic tiles 6 mm thick in flooring treads of steps and landing laid on a bed of 12 mm thick cement
mortar 1:3 (1-cement :3-coarses and) finishing with flush pointing in white cement. (upto 10 ton)
Water shall conform M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11.
Ceramic tiles shall be of approved colour and quality. The tile shall be even, sound regular
in shape and generally uniform in colour. It shall be without any soft veins, cracks of flows.
All angles and edges of the slabs shall be true square and free form chippings and giving plain surface. The thickness
shall be 10 mm to 15 mm. as specified in the item but not less than 10 mm. at any place.
Claddding for the ceramic tiles shall be cement mortar 1:3 (1 cement : 3 coarse sand) as given in the description of the
item. Sub grade shall be cleaned, wetted and mopped. Mortar of the specified mix and 10 mm thickness shall be
then be spread. Top surface of the mortar shall then be corrected by adding fresh mortar at hollows or
depressions. The mortar shall then be allowed to harden bit. Over this surface, cement slurry of honey like
consistency shall be applied. The slab shall then be gently place in position and tapped with wooden mallet till it is
properly pedded in level with and close to the adjoining slab. The joint shall be as fine as possible. The tiles fixed
in the floor adjoining the wall shall enter not less then 10 mm. under the plaster skirting or dado. The junction
between the wall floor shall be finished neatly. The finished surface shall be true to levels and slopes as directed.
The cladding shall be kept wet for a minimum period of 7 days. So that joints set properly.
The floor shall then be washed clean with water. The holes required for Nahni traps, pipes any other fittings shall be
made without any extra cost.
Mode of measurements & payment :
The risers of steps, skirting or dado shall be measured in sq. metre. Length shall be measured along the finished faces
of risers, skirting or dado. Height shall be measured from finished level of treads or floor to top. Lining of pillar shall
be measured under this item.
The rate shall be for a unit of sq. metre
Providing & Fixing 2mm Aluminium / 4mmACP sheeting fixed with Type-11 Class-C High Intensity Grade
Sheeting as per IRC 67 : 2012 reflective sheeting of size including lettering and signs as
Providing and laying Vitrified tiles 8 to 10 mm thick, 36''x36'' in flooring treads of steps and landing laid on a
bed of 12 mm thick cement mortar 1:3 (1-cement:3-coarses and) finishing with flush pointing in white cement.
Providing and Laying 36" x 36" vitrified 8 mm th.anti skid tiles of "RAK","Bell" or equivalent make as approved by
consultants flooring/skirting over 20 mm thick cement mortar 1:6 (1 cement : 6 coarse sand) on new surface & jointed
with colour cement slurry incl.with flush pointing & cleaning the surface etc.comp
Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11. vetrified tiles of
24" x 24" , 8 mm th.anti skid tiles. "RAK","Bell" or equivalent make
Bedding : Bedding of granite slabs shall be lime mortar 1:1.5 (1 Lime putty : 1.5 coarse sand) or cement mortar 1:6 (1
cement : 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at any
place shall not be less than 10 mm.
Laying : The surface of sub grade shall be cleared wetted and mopped. Mortar of specified mix and thickness shall
then be spread on an are sufficient to receive one granite slab, The slab shall be washed clean before laying. It shall
be laid on top pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and laid a side. The
top surface of the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The mortar shall
then be allowed to harden it over this surface cement slurry of honey like consistency at 4.4 Kg. Of cement per sq.
metre. The edges of slabs already paved shall be buttered with grey cement. The slab shall then be gently placed in
position and tapped with wooden mallet till it is properly bedded in level with and close to the adjoining slab. The joints
shall be as fine as possible : Surplus cement on the surface of the slabs shall be removed. The slab fixed in the floor
adjoining the walls shall enter not less 10 mm. under the plaster skirting or dado. The junction between the walls and
floors shall be finished neatly. The finished surface shall be true to level and slopes as directed.
Curing : The floor shall be cured for minimum period of seven days.
Mode measurements & payment :
flooring with various kinds of floors shall measured in sq. metre. The length and breadth shall be measured between
the finished face of skirting or dado or wall plaster. No deduction shall be made not extra shall be paid for any
openings in the floor or area upto 0.05 sq. mt. Nothing extra shall be paid for laying stone at different levels in the
same room. Treads and steps of stairs paved with granite stone slabs shall also be measured under flooring.
The rate shall be for a unit of one sq. metre
Providing and laying Vitrified tiles 8 to 10 mm thick, 24''x24'' in flooring treads of steps and landing laid on a
bed of 12 mm thick cement mortar 1:3 (1-cement:3-coarses and) finishing with flush pointing in white cement.
Providing and Laying 24" x 24" vitrified 8 mm th.anti skid tiles of "RAK","Bell" or equivalent make as approved by
consultants flooring/skirting over 20 mm thick cement mortar 1:6 (1 cement : 6 coarse sand) on new surface & jointed
with colour cement slurry incl.with flush pointing & cleaning the surface etc.comp
Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11. vetrified tiles of
24" x 24" , 8 mm th.anti skid tiles. "RAK","Bell" or equivalent make
Bedding : Bedding of granite slabs shall be lime mortar 1:1.5 (1 Lime putty : 1.5 coarse sand) or cement mortar 1:6 (1
cement : 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at any
place shall not be less than 10 mm.
Laying : The surface of sub grade shall be cleared wetted and mopped. Mortar of specified mix and thickness shall
then be spread on an are sufficient to receive one granite slab, The slab shall be washed clean before laying. It shall
be laid on top pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and laid a side. The
top surface of the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The mortar shall
then be allowed to harden it over this surface cement slurry of honey like consistency at 4.4 Kg. Of cement per sq.
metre. The edges of slabs already paved shall be buttered with grey cement. The slab shall then be gently placed in
position and tapped with wooden mallet till it is properly bedded in level with and close to the adjoining slab. The joints
shall be as fine as possible : Surplus cement on the surface of the slabs shall be removed. The slab fixed in the floor
adjoining the walls shall enter not less 10 mm. under the plaster skirting or dado. The junction between the walls and
floors shall be finished neatly. The finished surface shall be true to level and slopes as directed.
Curing : The floor shall be cured for minimum period of seven days.
Mode measurements & payment :
flooring with various kinds of floors shall measured in sq. metre. The length and breadth shall be measured between
the finished face of skirting or dado or wall plaster. No deduction shall be made not extra shall be paid for any
openings in the floor or area upto 0.05 sq. mt. Nothing extra shall be paid for laying stone at different levels in the
same room. Treads and steps of stairs paved with granite stone slabs shall also be measured under flooring.
The rate shall be for a unit of one sq. metre
Providing and laying Vitrified tiles 8 to 10 mm thick, in skrting risers of steps and dedo on 10 mm thick cement
plaster 1:3 (1-cement:3-coarse sand) and jointed with white cement slurry (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm thick, in skrting risers of steps and dedo on 10 mm thick cement
plaster 1:3 (1-cement:3-coarse sand) and jointed with white cement slurry (upto 10 ton)
Mode of measurements & payment : The rate shall be for a unit of one Sq. meter.
Providing and laying Vitrified tiles 8 to 10 mm thick, 24''x24'' in skrting risers of steps and dedo on 10 mm
thick cement plaster 1:3 (1-cement: 3-coarse sand) and jointed with white cement slurry (upto 10 ton)
Providing and laying Vitrified tiles 8 to 10 mm thick, 24''x24'' in skrting risers of steps and dedo on 10 mm thick
cement plaster 1:3 (1-cement: 3-coarse sand) and jointed with white cement slurry (upto 10 ton)
Mode of measurements & payment : The rate shall be for a unit of one Sq. mete
Providing and laying 24" x 24" vitrified 8 to 10 mm th.Double Charged Gloosy / Matt tiles of
Approved make as Approved by Adl.C.E. / Consultants for upto 10 cm high skirting as approved by
Engineer in charge over 10 mm thick cement mortar 1:6 (1 cement : 6 coarse sand)on new surface&
jointed with colour cement slurry incl with flush pointing & cleaning the surface etc. comp.
Mode of measurements & payment : The rate shall be for a unit of one Sq. mete
Providing and laying polished Kota stone slab flooring over 20 mm (Average) thick base of cement mortar 1:6
(1-cement:6-coarses and) or L.M.1.1.5 (1-Lime putty:1.5-coarses and) laid over and jointed with grey cement
slurry mixed with pigment to match the shade of slab including rubbing and polishing etc. complete. (A)
mm thick (upto 10 ton)
Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11. Marble stone
slab 20 mm. thick.
Dressing of slab : Every stone shall be cur to required size and fine chisel dressed to give a smooth and even surface
on all sides to the full depth. A straight edge laid along the sides of the stone shall be fully in contact with it. Chisel
dressing shall also be done on top surface to remove any waviness. The sides and top surface to granite slabs shall
be machine polished and molding etc. complete before using. All angles and edges of slabs shall be true square and
free form chippings.
The thickness of stone shall be 18 mm. The allowable tolerance shall be 1 mm. allowable. The tolerance shall be
mm. in length and breath.
Bedding : Bedding of granite slabs shall be lime mortar 1:1.5 (1 Lime putty : 1.5 coarse sand) or cement mortar 1:6 (1
cement : 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at any
place shall not be less than 10 mm.
Laying : The surface of sub grade shall be cleared wetted and mopped. Mortar of specified mix and thickness shall
then be spread on an are sufficient to receive one granite slab, The slab shall be washed clean before laying. It shall
be laid on top pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and laid a side. The
top surface of the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The mortar shall
then be allowed to harden it over this surface cement slurry of honey like consistency at 4.4 Kg. Of cement per sq.
metre. The edges of slabs already paved shall be buttered with grey cement. The slab shall then be gently placed in
position and tapped with wooden mallet till it is properly bedded in level with and close to the adjoining slab. The joints
shall be as fine as possible : Surplus cement on the surface of the slabs shall be removed. The slab fixed in the floor
adjoining the walls shall enter not less 10 mm. under the plaster skirting or dado. The junction between the walls and
floors shall be finished neatly. The finished surface shall be true to level and slopes as directed.
Curing : The floor shall be cured for minimum period of seven days.
Mode measurements & payment :
marble stone flooring with various kinds of marble shall measured in sq. metre. The length and breadth shall be
measured between the finished face of skirting or dado or wall plaster. No deduction shall be made not extra shall be
paid for any openings in the floor or area upto 0.05 sq. mt. Nothing extra shall be paid for laying stone at different
levels in the same room. Treads and steps of stairs paved with granite stone slabs shall also be measured under
The rate shall be for a unit of one sq. metre.
ITEM NO -68,69 ( Consider Marble Stone Instead of Kota stone for Item No. 67)
Providing and laying polished Kota stone slab flooring over 20 mm (Average) thick base of cement mortar 1:6
(1-cement:6-coarses and) or L.M.1.1.5 laid over and jointed with grey cement slurry including rubbing and
polishing etc.complete. (B) 30 mm thick (upto 10 ton)
Water shall conform to M-1. Lime mortar shall conform to M-10. Cement mortar shall conform to M-11. Marble stone
slab 20 mm. thick.
Dressing of slab : Every stone shall be cur to required size and fine chisel dressed to give a smooth and even surface
on all sides to the full depth. A straight edge laid along the sides of the stone shall be fully in contact with it. Chisel
dressing shall also be done on top surface to remove any waviness. The sides and top surface to granite slabs shall
be machine polished and molding etc. complete before using. All angles and edges of slabs shall be true square and
free form chippings.
The thickness of stone shall be 18 mm. The allowable tolerance shall be 1 mm. allowable. The tolerance shall be
mm. in length and breath.
Bedding : Bedding of granite slabs shall be lime mortar 1:1.5 (1 Lime putty : 1.5 coarse sand) or cement mortar 1:6 (1
cement : 6 coarse sand) of average thickness 20 mm. thick as given in description of item. Minimum thickness at any
place shall not be less than 10 mm.
Laying : The surface of sub grade shall be cleared wetted and mopped. Mortar of specified mix and thickness shall
then be spread on an are sufficient to receive one granite slab, The slab shall be washed clean before laying. It shall
be laid on top pressed and tapped gently to bring it in level with other slabs. It shall then be lifted and laid a side. The
top surface of the mortar shall then be corrected by adding fresh mortar at hollows, or depressions. The mortar shall
then be allowed to harden it over this surface cement slurry of honey like consistency at 4.4 Kg. Of cement per sq.
metre. The edges of slabs already paved shall be buttered with grey cement. The slab shall then be gently placed in
position and tapped with wooden mallet till it is properly bedded in level with and close to the adjoining slab. The joints
shall be as fine as possible : Surplus cement on the surface of the slabs shall be removed. The slab fixed in the floor
adjoining the walls shall enter not less 10 mm. under the plaster skirting or dado. The junction between the walls and
floors shall be finished neatly. The finished surface shall be true to level and slopes as directed.
Curing : The floor shall be cured for minimum period of seven days.
Mode measurements & payment :
marble stone flooring with various kinds of marble shall measured in sq. metre. The length and breadth shall be
measured between the finished face of skirting or dado or wall plaster. No deduction shall be made not extra shall be
paid for any openings in the floor or area upto 0.05 sq. mt. Nothing extra shall be paid for laying stone at different
levels in the same room. Treads and steps of stairs paved with granite stone slabs shall also be measured under
The rate shall be for a unit of one sq. metre.
Providing and laying polished kota stone slab 25 mm thick in risers of steps, skirting Dedo and pillars laid on
10 mm thick cement mortar 1:3 (1-Cement :3 coarses and) and jointed with gray cement slury mixed with
pigment to match the shade of slab including rubbing and polishing etc.complete. (upto 10 ton)
The relevant specifications of item no. 59 shall be followed except shall that the kota stone shall be fixed for risers
of steps, skirting or dado in C.M. 1:3 and the polishing shall be manually instead of machine polishing.
Mode of measurement & payment :
The risers of steps, skirting or dado shall be measured in sq. metre. Length shall be measured along the finished
faces of risers, skirting or dado. Height shall be measured from finished level of treads or floor to top. Lining of
pillar shall be measured under this item.
The rate shall be for a unit of 1 sq. metre.
Providing and laying cement concrete flooring 1:2:4 (1-cement: 2-coarses and:4-graded stone aggregate
20mm nominal size) laid in one layer and finished with a floating coat of neat cement. (A) 40mm thick.
Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6. Stone aggregate 20 mm.
nominal size shall conform to M-12.Cement concrete 1:2:4 proportion measured by volume shall conform to
relevant specification or ordinary grade 1:2:4 concrete.
The cement concrete flooring of 40 mm. thick (average) is to be laid as per the site condition. The concrete shall be
mixed in a mechanical mixer at the work. Hand mixer may however be allowed for smaller quantities of work and
in case of failure of machines or as permitted by the engineer-in-charge. It shall carried out on a water tight
platform and care shall be taken to ensure that mixing is continued until the mass is uniform in colour and
consistency. However in such cases 10% more cement than otherwise required shall have to be used without any
cost. The mechanical mixing shall be done for a period of /2 to 2 minutes. The quantity of water shall be thus
sufficient of produce a dense concrete required workability for the purpose. Flooring of specified thickness shall be
laid in accordance with approved pattern or as directed. Finishing operation shall start shortly after the cessation of
beating and shall be spread over a period of one to six hours depending upon the temperature and atmospheric
conditions. The surface shall be left for some time till moisture disappears from it. Fresh quantity of cement shall
be mixed with water to form a thick slurry and spread over the surface while the concrete is still green. Use of dry
cement or cement and sand mixture sprinkled on this surface to stiffen the concrete or absorb excessive moisture
shall not be permitted. The cement slurry shall than be properly paste twice by means of iron flats, once, when the
slurry is applied and the second time when cement starts setting and finished smooth. The surface shall be
marked with string or B.R.C. fabric jali to make the surface non slippery as and when directed. The junction of
floors with wall plaster dado or skirting shall be rounded where so required upto 25 mm. radius. Flooring in
lavatories and bath rooms shall be laid after fixing of water closet and squatting pans and floor traps, which shall
be plugged while laying the floors and opened after the floors, are completed. Any damage, done to water supply
sanitary fittings during the execution of work shall be mage good.
After the final set, the concrete shall be kept continuously wet, if required ponding for a period of not less than 7 days
from the date of placement.
The form work shall be provided if necessary as directed by the engineer in charge. Concreting shall be done as per
alternate bay method with necessary centering wither by mastic or cement mortar as directed.
Mode of measurement & payment :
The rate shall include the cost of all material and labour involved in all the operations described above. No deduction
shall be made or extra paid for any opening upto 0.1 sq. meter in area in the floor, nothing extra shall be paid for
laying the floor at different levels in the same room or the court yard.
The rate shall be for unit of one sq. meter.
Providing and laying cement concrete flooring 1:2:4 (1-cement: 2-coarse sand:4-graded stone aggregate 20mm
nominal size) laid in one layer and finished with a floating coat of neat cement. (B) 50mm thick. (upto 10 ton)
Water shall conform to M-1. Cement shall conform to M-3. Sand shall conform to M-6. Stone aggregate 20 mm.
nominal size shall conform to M-12.Cement concrete 1:2:4 proportion measured by volume shall conform to
relevant specification or ordinary grade 1:2:4 concrete.
The cement concrete flooring of 50 mm. thick (average) is to be laid as per the site condition. The concrete shall be
mixed in a mechanical mixer at the work. Hand mixer may however be allowed for smaller quantities of work and
in case of failure of machines or as permitted by the engineer-in-charge. It shall carried out on a water tight
platform and care shall be taken to ensure that mixing is continued until the mass is uniform in colour and
consistency. However in such cases 10% more cement than otherwise required shall have to be used without any
cost. The mechanical mixing shall be done for a period of /2 to 2 minutes. The quantity of water shall be thus
sufficient of produce a dense concrete required workability for the purpose. Flooring of specified thickness shall be
laid in accordance with approved pattern or as directed. Finishing operation shall start shortly after the cessation of
beating and shall be spread over a period of one to six hours depending upon the temperature and atmospheric
conditions. The surface shall be left for some time till moisture disappears from it. Fresh quantity of cement shall
be mixed with water to form a thick slurry and spread over the surface while the concrete is still green. Use of dry
cement or cement and sand mixture sprinkled on this surface to stiffen the concrete or absorb excessive moisture
shall not be permitted. The cement slurry shall than be properly paste twice by means of iron flats, once, when the
slurry is applied and the second time when cement starts setting and finished smooth. The surface shall be
marked with string or B.R.C. fabric jali to make the surface non slippery as and when directed. The junction of
floors with wall plaster dado or skirting shall be rounded where so required upto 25 mm. radius. Flooring in
lavatories and bath rooms shall be laid after fixing of water closet and squatting pans and floor traps, which shall
be plugged while laying the floors and opened after the floors, are completed. Any damage, done to water supply
sanitary fittings during the execution of work shall be mage good.
After the final set, the concrete shall be kept continuously wet, if required ponding for a period of not less than 7 days
from the date of placement.
The form work shall be provided if necessary as directed by the engineer in charge. Concreting shall be done as per
alternate bay method with necessary centering wither by mastic or cement mortar as directed.
Mode of measurement & payment :
The rate shall include the cost of all material and labour involved in all the operations described above. No deduction
shall be made or extra paid for any opening upto 0.1 sq. meter in area in the floor, nothing extra shall be paid for
laying the floor at different levels in the same room or the court yard.
The rate shall be for unit of one sq. meter.
Providing and fixing pre-cast concrete kerb stone of gray cement based concrete block
30 cm length, 30 cm height and 15 cm thick of M250 grade concret as per approved design and
including excavation for fixing in proper line and level, filling the joint with C:M 1:3 (1 cement :3 fine
sand) etc complete. (upto 10 ton)
Trenches of specified width and depth shall first be made along the edges of the wearing course of the road
or along the line of pave block flooring to receive the restraint blocks. The bed of the trenches shall be
compacted manually with steel rammers to a firm and even surface and then stones shall be set in P.C.C.
The edge restraint blocks shall be laid with their length running parallet to the paving edge, true
in line and gradient. The joints of blocks shall be not more than 10 mm and filled with the CM 1:3 (
cement : 3 fine sand ) which shall be cured for 7 days.
Finishing The edges shall be restored and all surplus earth including rubbish etc. disposed off as directed
by the Engineer-in Charge.
Measurements Length of the finished work shall be measured in running metre along the edge of the
paving correct to a cm.
Rate The rate shall include the cost of the materials and labour including stone of specified material
involved in all the operation described above. The rate shall be for a unit of one meter basis.
Providing and fixing pre-cast Rubber Dye / steel Dye inter locking concrete block 60mm thick with grade
of concrete M300 pneumatic compressed / vibrated mechanically and as per approved design Confirming
to IS 15658 : 2006 including 35 mm Sand layer for levelling and filling the joint with sand in proper line
and level as per guidlines of IRC : SP 63-2018 etc.
Scope of work :
Excavation and compaction up to 30 cm in height . for footpath paving in all sorts of soil murrum including
sorting outs and stacking of useful materials stuff up to 50 mt. lead from excavated place
and same well be carting. Up to 5 km.
The scope of work includes manufacturing, supplying and laying of precast paver blocks at various Retail
outlets. The work includes :
1.1 Verification of the existing site condition and advising our project in charge to lay suitable base
course if required. Contractors are required to satisfy themselves with quality of sub grade, sub-
base course before the paver blocks are laid and suggest strengthening if required.
1.2 Clearing the site by removing all obstacles such as stones, debris etc. for laying of paver blocks.
1.3 Manufacturing of paver blocks in your plant as per requirements in technical specification
1.4 Supplying of paver blocks at site, including handling at both ends.
1.5 Laying of paver blocks at site as per requirement in technical specification, within shortest possible
time. The site being existing operating Retail Outlets, care should be taken to ensure that the
operation is not closed. The job of laying may required to be carried out during night also.
1.6 Testing of paver blocks through reputed Govt./Non Govt. Test house and submission of test results
as per requirements in Technical Specifications. HPCL reserves the right to carryout test at
random. Cost for such tests to be borne by party.
1.7 The contractor shall guarantee that all material and components designed, fabricated, supplied and
laid by him shall be free from any type of defect due to faulty material and/or
workmanship/erection for a period of One year from the date of completion of work at individual
sites. However, the contractor fro two years shall render free maintenance.
TECHNICAL SPECIFICATIONS :
I) Paver Block Manufacturing Facilities :
The Paver Block shall be made in factory with following minimum facilities :
1.1 Concrete Block making Machines :
The machine should be capable of producing high quality Paver Blocks by obtaining high
level of compaction by application of hydraulic compaction and also by high intensity vibration to
the moulds. The machine should have automatic control panel for uniformity in strength.
1.2 Concrete Batching & Mixing Plant : (Not essential)
The concrete Mix Design should be followed for each batch of materials. The concrete
ingredient should be mixed in concrete Batching & Mixing plant with minimum capacity of
cum/hour. The plant should equipped with automatic control panel for maintaining water cement
ratio from batch to batch to obtain concrete of uniform quality and strength. The plant should be
equipped with adequate mechanism for mechanized loading of raw materials into mixer and
conveyor belt for transportation of concrete from mixer to concrete block making machine to
maintain quality of wet cement.
The factory should have well designed curing area to ensure adequate curing of paver blocks.
For the Rubber mould paver block specification has to followed as per specification of Gray and coloured paver
block specification. But at the production level the mould for producting rubber moulded paver block
the mould is of rubber materials and the prodection of rubber moulded paver block is even shaded,
finishing and even colour shaded and using Rubber mould should be producing on vibratory mechine by
obtaing high level of compaction by application of vibration to the moulds. The machine should have
automatic control pannel for uniformity in strength. Or as per direction of engineering incharge.
1.5 Laboratory (Desirable but not essential) :
The factory should have the following:
(i) Compression testing machine of adequate capacity.
(ii) Other tools and equipment for testing raw materials and paver blocks.
(iii) (1).Systematic record of test results of various paver blocks manufactured in the factory.
(2).Concrete Mix Design for various grade of concrete used for making of paver blocks.
II) SPECIFICATIONS FOR COLOURED PAVER BLOCKS :
Coloured concrete paver blocks shall be manufactured as per attached specifications using approved colour
Pigment of “BAYER” Make “BAYFERROX IRONOXIDE PIGMENTS” with minimum colour pigment of
3% by weight of cement. The colour shade shall be “RED” as selected by HPCL before commencement of
the work. White cement shall be used for colored pavers to obtain the desired colour shade. The job also
includes providing 50 mm thick sand bedding to match the shade of the paver block.
The colour of the paver block shall be guaranteed against fading of colour for period of 12 months from the
date of laying of the same at site.
All other technical specifications & Procedure for testing, laying & sampling of coloured pavers will be as
per attachment.
III) PAVERS BLOCK CHARACTERISTICS :
The concrete pavers should have perpendicularities after release from the mould and the same should be
retained until the laying.
The surface should be reasonably smoothe and of anti skid and anti glare type.
The paver should have uniform chamfers to facilitate easy drainage surface run off.
The pavers should have uniform interlocking space of 2mm to 3mm to ensure compacted sand filling after
vibration on the paver Surface.
The concrete mix design should be followed for each batch of materials separately and automatic batching
plant is to be used to achieve uniformity in strength and quality.
The pavers shall be manufactured in single layer only.
Skilled labour should be employed for laying blocks to ensure line and level of laying, desired shape of the
surface and adequate compaction of the sand in the joints.
The pavers shall be of cement gray colour without any pigment & for coloured pavers refer “specifications
for coloured pavers.”
The pavers are to be skirted all round with kerbing using solid concrete blocks of size 150mm X 250mm X
380mm. The kerbing should be embedded for 100mm depth. The concrete used for kerbing shall be cured
properly for 7 days minimum.
IV) Paver Block Dimensions :
Thickness 60mm or 80mm
Shape Uniregular (Uniform Shape with no Hollow
Chamfer 4mm to 6mm along top edges
Colour a. Natural cement grey colour without
use of any pigment.
b. For coloured pavers refer
“specifications for coloured pavers”
Dimensional Tolerance (+/-) 2mm for length & width,
(+/-) 3mm for Height (Thickness)
V) Testing of Paver Blocks :
SR. Average Values
NO. (Average of Minimum
Five Samples/Site)
1. Compressive Strength Min. 45 N/Sqmm for 80mm
thick OR Min. 30 N/Sqmm for
2. Flexural Strength Minimum 4.5 N/Sqmm
3. Abrasion Resistance Maximum
4. Water Absorption Maximum 5.80%
5. Minimum Cement Contact 380 Kg/Cum (Not Essential)
* Sampling and Testing procedure as per enclosed specifications
SAMPLING AND TESTING PROCEDURES FOR PAVER BLOCKS.
INTERNAL – Average of minimum 3 samples per 5000 Blocks.
Essential – Minimum 2 Blocks per 10000 bocks. Average of minimum 8 blocks per site.
1. Sampling For Testing
Sampling for testing of paver blocks shall be done in accordance with Appendix-A.
2. Compressive Strength
Testing for compressive strength shall be undertaken in accordance with Appendix-B.
The average compressive strength of the bocks tested shall be 40 N/Sqmm.
3. Abrasion Resistance
Testing for abrasion shall be in accordance with IS 1237 (Specifications for Cement Concrete Floor Tiles) –
4. Flexural Strength
Testing for flexural shall be n accordance with IS 1237 (Specifications for Cement Concrete Floor Tiles) –
5. Water Absorption
Testing for water absorption shall be in accordance with IS 2185:1979 : Part I (Specifications for Concrete
Masonry Units) – Appendix E.
Sampling of Paver blocks.
1. Method of sampling :
Before laying paver blocks, each designated section comprising not more than 50000 blocks, shall be divided
into ten approximately equal groups. Three blocks shall be drawn from each group.
2. Marking and identification :
All samples shall be clearly marked at the time of sampling in such a way that the designated section of part
thereof, and the consignment represented by the sample, are clearly defined.
The sample shall be dispatched to the approved test laboratory taking precaution to avoid
damage to the paving in transit. Protect the paving from damage and contamination until they have been
tested. The testing shall be carried as soon as possible, after the sample has been taken. As soon as
practicable after sampling. The samples shall be stored in water at 20 degree C 5 degree C for 24 hours
prior to testing.
The rate shall be for a unit of one square meter.
Providing and laying broken china mosaic flooring for terrace using 12 mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or slope and to be tempered to bring mortar creme out upto
surface using white cement including rounding off junctions and extending them up to15 cm along the wall,
clearing with water and oxalic acid etc.asdirected.
Providing and laying China Mosaic finishing over flat or curved surface, including laying to approved patterns, with
precies leveling and setting curvatures with necessary tools and templates, using white/coloured broken ceramic tile
chips, set in pigmented cement mortar 1:4, as directed, finishing in line, level and to required slope, flushing with
appropriate pigimented cement grout, curing and finishing with mild acid wash etc. complete.
(1) China Chips in required colours specially broken from full tiles in required size
(2) Cement (3) Sand (4) White Cement (5) Steiner
Before laying a final layer of China Chips prepare the surface to the required slope and level with a backing
coat in C.M (1:3). While laying a backing coat, spread a layer of thick cement slurry and scrub the same vigorously to
seal all pores in concrete below.
For the required designs prepare templates for different patterns from steel flats or plywood and mark out total design
on the designated area. Estimate the quantity of Chips of different colous and ensure its uninterrupted supply before
starting the work. Lay the chips flat on the bedding coat and fix tightly be light hammering. Remove grey cement from
the joints by scrapping before final set of cement.
Finish the joints neatly with white cement and harmonious colour Steiner. All design and pattern shall be finished with
first class workmanship. The surface should finally cleaned, given a mild acid wash for gain the luster of China Chips.
Cost of China Chips, White cement, OPC, Sand, Steiner and all labour for leveling, laying by specialist artisan,
preparing templates, testing etc are included.
MODE OF MEASUREMENT :
Dimensions of total finished area as laid are recorded and area is computed in sq.m., rounded to two places of
Providing and laying coloured glazed tiles of the size 300 mmx200 mmx8 mm/300 mmx450 mmx8 mm in
skirting, risers of steps and dedo on 10 mm. thick cement plaster 1:3 (1cement: 3 coarse sand) & jointed with
white cement slurry.
Workmanship : The work shall be carried out for skirting as dedo. Before fixing glazed tiles of shade and size as specified,
the surface shall be prepared by heavy scarping, making joints etc. to the required line, level and plumb. The surface shall be
thoroughly wetted before commencing the laying work. Thereafter about 10 mm. thick backing of cement mortar in specified
proportion shall be applied on the surface in true like and level generally as per specifications of plaster item.
Fixing : The black of each tile to be fixed shall be smeared with cement paste of matching colour and the glazed tiles shall then
be gently tapped against the surface, with a wooden mallet. The skirting shall be done only after the flooring is competed. Any
pipes coming out of the wall through the dedo or skirting shall only beat at the intersections of the horizontal and vertical joints.
The tiles shall not have staggered joints. The joints shall be true to entire line both ways and vertical joints shall be in line with
joints of flooring. Tiles shall be fixed as close as possible to the adjoining tiles and any difference in the thickness of the glazed
tiles shall be evened out in the cement paste so that all the tiles faces are set in conformly with one another. The skirting shall
project uniformly and not more than 6 mm. thickness beyond the finished surface above. Top of skirting of dedo shall be truly
horizontal. The rises of steps, skirting or dedo shall rest on top of treads of flooring wherever required. The tiles shall be cut
(sawn) and thin edges smoothened before use.
Curing : Curing shall be done for 7 days continuously.
Finishing : Skirting and dedo shall be hand polished to have an even smooth and shining surface. In case of skirting only 10 mm.
x 10 mm. grove shall be provided at the junction of cement plaster and cement tilesThe white glazed tiles shall be laid on cement
mortar bedding of 12 mm thick in C.M. 1 :3 . The mortar shall have sufficient plasticity for laying and there shall be no hard
lumps that would interfere with the evenness of bedding the base shall be cleared with well wetted. The mortar shall then be
spread in thickness not less than 10 mm at any place and average 12 mm thickness. The proportion of the cement mortar shall
be as specified in the item.
The tiles before laying shall be soaked in water for atleast two hours Neat Gracie cement grout at 3.3 Kg/Cement /Sq. mt. Of
honey like consistency shall be separated over the mortar bedding as directed. The edges of the tiles be smeared with neat
cement slurry. The tiles shall be well pressed and gently tapped with a wooden mallet till they are properly bedded and in level
with the adjoining tiles. There shall be no hollows in bed or joints. The joints between the tiles shall be as thin as possible in
straight line or as per pattern.
The tiles shall not have staggered joints. The joints shall be true to centre line both ways. The Nehni trap coming in the flooring
shall be so positioned that its grating shall replace only one tile as far as possible. Where full size tiles cannot be fixed, they shall
be cut (swan0 to be required size and the edges rubbed smooth to ensure straight and true joints. The joints shall be filled with
grey cement grout with wire brush of trowel to a depth of 5 mm. and loose material removed. White cement shall be used for
pointing the joints., After fixing the tile finally in an even the flooring shall be kept wet and allowed to nature undisturbed for
The surplus cement grout that may have come out of the joints shall be cleared off before it sets. Once the floor has set, it shall
be carefully washed, cleared by dilute acid and dried. Proper precaution and measures shall be taken to ensure that the tiles are
not damaged inany way till the completion of the construction.
Mode of measurement & payment
The work done shall be measured in sq. mt. For visible area of work done, The length and width of the flooring shall be
measured not between the faces of skirting or dedos or plastered face of wall as the case may be. The paving under dedo or
skirting shall not be measured. No deduction shall be made not extra paid for any opening in the floor of area upto 0.1 sq. mt.
Nothing extra shall be paid for laying the floors at different levels in the same rooms.
The rate shall be for a unit of one sq. metre.
Providing corrugated G.I. sheet of class-3 roofing fixed with glavanished iron J or L Hooks, Bolts and nuts
mm diameter with bitumen and G.I. limpet washer or G.I. limpet washer. filled with white lead complete
excluding the cost of purlins, Rafters and Trusses. (1) 0.80 mm thick sheet.(up to10 ton)
Mode of payment shall be in Sqm and the work shall be done as specified in Above Item.
Providing ridges or hips 600 mm over allin plain G.I. sheet class-3 fixed with G.I. J or L Hooks
and nuts 8 mm dia G.I. Limpet and bitumen washer complete. (1)
Mode of payment shall be in Sqm and the work shall be done as specified in Above Item.
Providing and fixing 150 mm wide 450 mm over all semi circular plain G.I.sheet class-3 gutter with
Iron brackets 40 mmx3 mm size Bolts, Nuts, washers etc. including making necessary connection
with rain water pipes. (i) 0.80 mm thick
Mode of payment shall be in Sqm and the work shall be done as specified in Above Item.
Providing and fixing five courses water profing treatment with bitumen felt consisting of
second and fourth course of blown/ bitumen or/and residual bitumen applied hot at
kg.per Sq.M.of area for each course and first course with fibre base bitunen saturated under
lay type land third course with fibre base self finished felt type 2 grade 1 and fifth and final course of
stone grit 6 mm and down size or pea sizes gravel spread at
Cu.Metre/Sq.metre preparation of surface excluding grading complete. (upto 10 ton) including
Mode of payment shall be in Sqm and the work shall be done as specified in Above Item.
FORM OF GUARANTEE BOND
"I/We……………………………(Contractor)hereby guarantee that work will remain
unaffected and will not be in any way damaged by termite or any other germs of similar type
for period of 05 years after completion of the work of anti0termite as per the terms and
condition of the contractor and contractor hereby indemnifies and agrees to save harmless the
Government of Gujarat from any loss and or damage that might be caused account of termite
and or other similar type of germs and hereby Guarantee to make good any loss or damages
suffered by the Government of Gujarat and further guarantee to redo the effective work
without claiming any extra cost"
This guarantee shall remain force for the period of 05 year from the completion of the work
under the contract and it shall remain binding to the contractor for period of 05years.
The deposit at the rate of 50% of the cost of this item from the running and final bills shall
be recovered and retained for the fist one year after the completion of the completion of the
guarantee period.
Mode of Measurement :
The length and breadth shall be measured correct to cm as per the dimensions of sanctioned
plans NO deduction shall be made not extra paid for and opening for pipe etc. upto 0.1 sq mt
The rate shall include the cost of all labour materials required for the operation involved for
satisfactory completion of this item The saids of the trenches 30cms each side and bottom
shall be measured under this item.
The rate shall be for a unit of one sq. meter.
Providing and fixing on wall face C.I. Rain water pipe including filling the joints with spun yarn soaked in neat
cement slurry and cement mortar 1:2(1- Cement : 2-fine sand) (A) 75 mm dia.
Mode of payment shall be in Rmt
Providing 15 mm thick cement plaster in single coat on Rough (Similar) side of single or half brick walls for
interior plastering up to floor two level and finished even and smooth in (i) Cement mortar 1:3 (1-cement :3-
Mode of payment shall be in Sqm
Providing 20mm thick sand faced cement plaster on walls upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M. 1:3 (1-cement : 3-sand) and 8mm thick finishing coat of C.M.
1:1 (1-cement : 1-sand) etc. complete.
The specification is as per above Item except thickness of the plaster is 20 mm sand faced and 12 mm th. Backing coat in
C.M. (1:3) and 8 mm thick finishing coat no machine paster will be allowed for spray od sand for plastering etc comp as directed
by Engg i charge.
Mode of measurements & payment : The rate shall be for a unit of one Square Meter.
Water M-1. The Cement mortar of proportion 1:3 shall conform to M-13.
Scaffolding : Wooden ballies, bamboos, planks, treatles and other scaffolding shall be sound. These shall be properly
examined before erection and use Stage scaffolding shall be provided for ceiling plaster, which shall be independent of
Preparation of back-ground :
The surface shall be cleaned of all dust, loose mortar droppings, traces of algae, afflorescence and other foreign matter by
water or by brushing. Smooth surface shall be roughened by wire brushing if it is not hard and by racking if it is hard. In
case of concrete surface, if a chemical retarder has been applied to the form work, the surface shall be roughened by
wire brushing and all the resulting dust and loose particles cleaned off and care shall be taken that none of the retarder
is left on the surface. Trimming of projections on brick/concrete surface where necessary shall be carried out to get an
Raking of joints in case of masonry where necessary shall be allowed to dry out for sufficient period before carrying out the
The work shall not be soaked but only damped evenly before applying the plaster. If the surface becomes dry such area
shall be moistened again.
For external plaster, the plastering operation shall be started from top floor and carried downwards. For internal plaster, the
plastering operations may be started wherever the building frame and cladding work are ready and the temporary
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.