Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAdmitted-Finance MURSHIDABAD DIVISION M E DIRECTORATE | L1 | Admitted-Finance | |
| 2 | L2₹5.4 L+₹20,600 (3.99%)Admitted-Finance CHALITIA BERHAMPORE MURSHIDABAD | BERHAMPORE | MURSHIDABAD | WEST BENGAL | L2 | Admitted-Finance | |
| 3 | L3₹5.4 L+₹25,990 (5.03%)Admitted-Finance 159B M G ROAD HARIDEVPUR KOLKATA WEST BENGAL 700082 UDYAM WB 10 0018308 | KOLKATA | WEST BENGAL | 700082 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S MONDAL ASSOCIATES L1 | MONDAL ENTERPRISE L3 | G.M.N. ENGINEERING L2 |
|---|---|---|---|---|---|---|
| 1.00 | Electrical different distribution box and electrical appliances
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (8way), Make: LEGRAND,L&T , ABB, SIEMENS, , schneider. (for Gound Floor) | 1 | Nos | 5,248.68 ₹5,248.68 Lowest | 6,348.68 ₹6,348.68 | 6,248.68 ₹6,248.68 |
| 2.00 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+12 Way), Make: LEGRAND,L&T ,ABB, SIEMENS, schneider. (for Gound floor) | 1 | Nos | 2,298.87 ₹2,298.87 Lowest | 3,398.87 ₹3,398.87 | 3,298.87 ₹3,298.87 |
| 3.00Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionMake:Legrand,L&T ,Schneider,ABB,Crabtree | ||||||
| 3.01 | TP(63A) | 1 | Nos | 1,792.46 ₹1,792.46 Lowest | 2,892.46 ₹2,892.46 | 2,792.46 ₹2,792.46 |
| 3.02 | SP(6-32A) For Outgoing for DBs and Exiting DBs | 24 | Nos | 238.26 ₹5,718.24 Lowest | 348.26 ₹8,358.24 | 338.26 ₹8,118.24 |
| 4.00Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. | ||||||
| 4.01 | FP(63A) four pole HTPN Incoming | 1 | Nos | 1,057.12 ₹1,057.12 Lowest | 1,157.12 ₹1,157.12 | 1,057.12 ₹1,057.12 Lowest |
| 4.02 | DP(40A) For Incoming | 1 | Nos | 436.19 ₹436.19 Lowest | 446.19 ₹446.19 | 436.19 ₹436.19 Lowest |
| 5.00Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC | ||||||
| 5.01 | Average run 12 mtr | 4 | Point | 1,784.12 ₹7,136.48 Lowest | 1,884.12 ₹7,536.48 | 1,784.12 ₹7,136.48 Lowest |
Tender Value
Refer Docs
EMD Value
₹10,405
Closing Date
28 Feb 2026, 12:00 pmClosed
Executive Engineer,PWD
O/o The Executive Engineer Murshidabad Electrical Division P.W.Dte. 184, C.R.Das Road, Berhampore, Murshidabad, PIN -742101
Electrical work at Digital X ray room at Kandi Hospital at Murshidabad.
2026_WBPWD_1010099_1
WBPWD/EE/MsdED/62/e-Q of 25-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
20 days
Murshidabad
Please refer Tender documents.
5 documents required · 5 mandatory
₹10,405
11 Aug 2026
18 Feb 2026
2 Mar 2026
18 Feb 2026
28 Feb 2026
20 Feb 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Electrical different distribution box and electrical appliances
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (8way), Make: LEGRAND,L&T , ABB, SIEMENS, , schneider. (for Gound Floor) | 1 | Nos | - | - |
| 2 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, on wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment (2+12 Way), Make: LEGRAND,L&T ,ABB, SIEMENS, schneider. (for Gound floor) | 1 | Nos | - | - |
| 3Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionMake:Legrand,L&T ,Schneider,ABB,Crabtree | |||||
| 3.01 | TP(63A) | 1 | Nos | - | - |
| 3.02 | SP(6-32A) For Outgoing for DBs and Exiting DBs | 24 | Nos | - | - |
| 4Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection. | |||||
| 4.01 | FP(63A) four pole HTPN Incoming | 1 | Nos | - | - |
| 4.02 | DP(40A) For Incoming | 1 | Nos | - | - |
| 5Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe (for horizontal & vertical run in wall and celing portion through prelaid polythen pipe) complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board with top cover plate flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC | |||||
| 5.01 | Average run 12 mtr | 4 | Point | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.43 MB
Tendernotice_2.pdf
PDF • 0.55 MB
BOQ_2480038.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .