| 1 | L1₹11.4 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC Lowest Bidder, hence accepted | |
| 2 | L2₹11.8 L+₹1,633 (0.14%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance Higher Quoted Bidder | |
| 3 | L3₹11.9 L+₹10,515 (0.89%)Rejected-Finance | L3 | Rejected-Finance Higher Quoted Bidder | |
| 4 | L4₹12.0 L+₹14,720 (1.25%)Rejected-Finance | L4 | Rejected-Finance Higher Quoted Bidder | |
| 5 | L5₹13.3 L+₹1.5 L (12.8%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L5 | Rejected-Finance Higher Quoted Bidder |
Tender Value
₹25.0 L
EMD Value
₹50,000
Closing Date
20 Oct 2021, 6:00 pmClosed
GE (AF) Phalodi
Military Engineer Services Garrison Engineer (AF) Near Kundal Village, Phalodi (Rajasthan)-342 301
REPAIR/REPLACEMENT OF UNSERVICEABLE INTERNAL ELECTRIFICATION AT AF STN PHALODI
2021_MES_477193_1
8358/A/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Phalodi
Class E Cat a(i)
7 documents required · 7 mandatory
₹500
GE (AF) PHALODI
₹50,000
Yes
14 Dec 2021
23 Sept 2021
26 Oct 2021
23 Sept 2021
20 Oct 2021
7 Oct 2021
Amount
Taking down carefully old unserviceable existing copper/aluminium point wiring (light, fan, socket or power) complete including teak wood battens or from existing conduits with all fittings, such as switches, ceiling rose, pendants, sockets, lamp holder, fan regulators, sketch/brackets, light fittings (except tube light fittings) but excluding ceiling fan and removal of old material from site and making good disturbed surfaces of walls, floors ceiling etc to match with existing surfaces complete all as specified and directed.
Note for Srl Item Nos. 1 to 76 :- (i) Contractor will depute One Electrician and One helper per day for daily basis for attending the complaints all as directed by Engineer-in-charge. The quoted rate of items shall be deemed to be inclusive of this aspect. (ii) Contractor/Supervisor will collect electrical complaints from concern JE on daily basis and will complete on same day and submit the performance silip duly signed by user's/complaintant. (iii) Contractor will provide suitable transportation for attending daily basis complaints on site like cycle/Motorcycle etc to each electrician/helper with proper driving licence/Helmet etc and keep permission of vehicle for inside premises by competent authority. (iv) Contractor will responsible for safety of the tradesmens employed by them. (iv) Contractor will provide equipments like Tester, Test lamp, Multi meter, cutting plier, screw driver, plier, electric hammer, drill machine, electrical wall cutting machine, wiring steel wire etc on his own arrangement for rectifying the complaint and also screws, nut, bolt, insulation tape, as per site requirement and no other payment will be made for the same.
M&L point wiring for one light point / bell point /ceiling fan point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LS in and including PVC conduit 20 mm dia, medium duty, ISI marked for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FR-LS connected to common earth dolly for fixing of modular switch,sockets etc complete all as specified and directed. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per srl item No. 2.00 above but for one 3 pin socket out let 5 Amp on same board.
All as per srl item No. 2.00 above but for one 3 pin socket out let 5 Amp on independent board.
All as per srl item No. 2.00 above but for 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FR-LS multi strand on independent board including provn of 1.5 Sqmm unsheathed, multi stranded copper conductor cable FR-LS continues as earth wire connected to earth dolly etc complete all as specified and directed.
All as per srl item No. 2.00 above but for call bell point.
All as per item No 2.00 above but for but one light point controlled by two switches two way.
S& F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) one way etc complete all as specified and directed.
S& F modular type switch piano type, 6 Amp 240 Volt, AC (ISI Marked) two way etc complete all as specified and directed.
S&F modular one socket outlet 5 Pin 5 Amp 230 volts AC complete all as specified and directed.
S&F modular one socket outlet multipurpose 3 Pin 5 Amp and 6 Pin 15 Amp 230 volts AC complete all as specified and directed.
S&F modular Ceiling fan regulator electronic step type 230V complete all as specified and directed.
M&L point wiring for one light point /ceiling fan point /bell point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LS in existing concealed PVC conduit including new steel terminal sunken boxes suitable for modular switch/socket flush to surface (including modular frame and cover plate) for one light point, fan point , controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm multi stranded copper conductor cable FR-LS connected to common earth dolly complete all as specified and directed by Engineer-in-charge. Note :- Switches, sockets etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per item No 13 above but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 13 above but for 3 pin 15 Amp socket out let by using 2.5 Sqmm PVC insulated sheathed copper conductor cable FR-LS multi strand on independent board including provn of 2.5 Sqmm sheathed, multi stranded copper conductor cable FR-LS continues as earth wire connected to earth dolly etc complete all as specified and directed.
All as per item No 13.00 above but for but one light point controlled by two switches two way.
M & L for point wiring for one light / fan point controlled by one switch with 1.5 Sqmm PVC insulated, sheathed multi strand copper conductor cable FR-LS in Casing Caping , flush to surface for one light point/fan point, controlled by one switch on the same board with other switch or independent including PVC insulated sheathed 1.5 Sqmm copper conductor cable FR-LS connected to common earth dolly complete all as specified and directed. Note :- Switches, sockets,Gang Boxex etc shall be measured and paid for separately under appropriate items of Sch 'A'.
All as per item No 17.0 above but for socket 5 Pin, 5 Amp 230 Volt on same board.
All as per item No 17.0 above but for one socket point outlet 3 Pin, 5 Amp 230 Volt on independent board.
All as per srl item No. 17.0 above but for 3 pin 15 Amp socket out let by using 4 Sqmm PVC insulated sheathed copper conductor cable FR-LS multi strand on independent board including provn of 4 Sqmm unsheathed, multi stranded copper conductor cable FR-LS continues as earth wire connected to earth dolly etc complete all as specified and directed.
All as per srl item No.17.0 above but for call bell point.
All as per item No 17.0 above but for but one light point controlled by two switches two way.
Supply anf Fixing switch piano flush type, 6 Amp 240 Volt, AC one way etc complete all as specified and directed.
Supply and Fixing switch piano flush type, 15 Amp 240 Volt, two way etc complete all as specified and directed.
S&F one flush type socket outlet 5 Pin 5 Amp, 230 volts AC complete all as specified and directed.
S&F one switch socket combination 2 in 1, 5 Amp, flush type complete all as specified and directed.
S&F one socket outlet flush type 3pin 15 Amp, 230 volts AC complete all as specified and directed.
S&F one switch socket combination 3 pin 16 Amp, flush type complete all as specified and directed.
S&F Ceiling fan regulator flush type electronic step type , 230V complete all as specified and directed.
S&F bell push, flush type 5 Amp, 230 V complete all as specified and directed.
S&F ceiling rose surface polycarbonate 65mm x 50mm, 3 terminals with back plate etc complete all as specified and directed.
S&F Lamp holder of PVC / Polycarbonate type for batten fittings surface all as specified and directed.
S&F call bell ding dong type, AC, 230 V etc complete all as specified and directed.
Supply and fixing in repair of Single pole and neutral sheet metal enclosure with a two pin and earth plug and socket, one single pole 20 Amps, 240V MCB complaints complete all as specified and directed.
Supply and fixing in repair of Single door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 2 way, 240 Volt, suitable for fixing MCBs, isolators etc complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 4 way, 240 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 8 way, 240 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting SPN, 12 way, 240 Volt, with 200 Amp rated bus bar suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
Supply and fixing double door sheet metal enclosure made out of CRCA mild steel sheet concealed surface mounting TPN, 4 way, 415 Volt, suitable for fixing MCBs, isolators etc including taking down old complete all as specified and directed.
S&F in renewal Isolator FP 125 Amps C curve MCB repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal Isolator FP 100 Amps C curve MCB, 415 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB TPN 63 Amps C curves MCB, 415 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SPN 63 amp C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB SPN 40 amp C curve MCB, 240 V repturing capacity 10 KA etc complete all as specified and directed.
S&F in renewal MCB 6 Amp to 32 Amp SP capacities 'C' series, 240 V, 10KA rupturing capacaity complete all as specified and directed.
Supply and Fixing in repair modular white cover plate with frame, 2module complete all as specified and directed.
Supply and Fixing in repair modular white cover plate with frame, 3module complete all as specified and directed.
Supply and Fixing in repair modular white cover plate with frame, 4module complete all as specified and directed.
Supply and Fixing in repair modular white cover plate with frame, 6 module complete all as specified and directed.
Supply and Fixing in repair of unserviceable/broken Bakelite hylem sheet of size (8"X10") with suitable screw etc complete all as specified and directed.
Supply and Fixing in repair of unserviceable/broken Bakelite hylem sheet of size (7"X4"). with suitable screwetc complete all as specified and directed.
Supply and Fixing in repair of unserviceable/broken Bakelite hylem sheet of size (10"X12") with suitable screw etc complete all as specified and directed.
Supply and Fixing in repair of unserviceable/broken Bakelite hylem sheet of size (4"X4") with suitable screw etc complete all as specified and directed.
Supply and fixing in repair of unserviceable 25 mm width heavy duty double lock press type casing & caping ISI marked fixed to wall /ceiling using screws of suitable size including removing the existing for replacement complete all as specified and as directed.
All as per item No 54 above but 40 mm width.
Supply and fixing in repair 3 pin 15 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
Supply and fixing in repair 3 pin 5 Amps Plug Top 250 Volts heavy duty complete all as specified and as directed.
Sub main wiring with 4 X 6sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn through PVC conduit 32mm dia medium duty and including PVC insulated 1X4 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note:- 4 lengths of 6 Sqmm and 1 length of 4 sqmm cable, PVC Conduit will be measured as one unit or running metre.
Sub main wiring with 4 X 6sqmm single core cable PVC insulated unsheathed of copper multi strandard conductor cable , 1100 votls grade drawn through existing surface/ recessed steel/ PVC conduit medium duty and including PVC insulated 1X4 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring including taking down old sub main wiring complete all as specified and directed. Note:- 4 lengths of 6 Sqmm and 1 length of 4 sqmm cable will be measured as one unit or running metre.
Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 6 sqmm, 1100 votls grade drawn through PVC Casing & Caping 40mm width medium duty and including PVC insulated 4.00 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note:- Two lengths of 6 Sqmm & 1 length of 4 sqmm cable, & PVC Casing caping will be measured as one unit or running metre.
Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 6 sqmm, 1100 votls grade drawn through existing surface/ recessed steel/ PVC conduit and including PVC insulated 4.00 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly complete all as specified and directed. Note:- Two lengths of 6 Sqmm and 1 length of 4 sqmm cable will be measured as one unit or running metre.
Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 4 sqmm, 1100 votls grade drawn through PVC conduit 20 mm dia medium duty and including PVC insulated 2.5 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note:- Two lengths of 4 Sqmm and 1 length of 2.5 sqmm cable, 20mm PVC Conduit will be measured as one length.
Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 4 sqmm, 1100 votls grade drawn through PVC Casing & Caping 20mm width medium duty and including PVC insulated 2.5 sqmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note:- Two lengths of 4 Sqmm and 1 length of 2.5 sqmm cable, 20mm PVC Casing caping will be measured as one unit or running metre.
Sub main wiring with two single core cable PVC insulated unsheathed of copper multi strandard conductor cable of size 4 sqmm, 1100 votls grade drawn through existing surface/ recessed steel/ PVC conduit and including PVC insulated 2.5qmm unsheathed multistranded FR-LS copper conductor cable for earth continuity and connected to common earth dolly including taking down old sub main wiring complete all as specified and directed. Note:- Two lengths of 4 Sqmm and 1 length of 2.5 sqmm cable will be measured as one unit or running metre.
S&F in renewal for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burred in ground vertically earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick each connected to and including GI earth wire 4 mm dia by means of GI nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 15 mm dia GI pipe light grade for protection of earth lead from earth plate upto 5 mtr and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 using 20mm stone aggregates for earthing pit, 10mm thick cast iron cover with angle iron frame and shown in electrical plate No 3 of SSR Part-I and testing on complete all as specified and directed.
Supply & fixing in repair LED batton fitting 1 x16 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
Supply & fixing in repair LED batton fitting 1 x20 Watt, 220 V decorative box type with driver 4" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed.
S&F in repair LED light fitting 10 Watt 2 feet mirror light luminarire with poly carbonate cover complete with all acessories and driver including connections with with 3 core copper wire of suitable size complete all as specified and directed.
S&F in repair LED light fitting, 1X25 watt, complete with tuff net glass protection IP:66, fixed to walls with GI bracket made out of suitable size of light grade pipe 32 mm dia tubing upto 1.2 mtr length bent to shape with 02 sets of MS clamps made out of 25x3 mm MS flat iron with suitable bolt and nuts and testing etc complete all as specified and directed.
S&F in repair LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 core copper conductor cable etc complete all as specified and directed.
S&F in repair LED Ceiling light circular recessed mounted/ Surface mounted LED flat panel complete, 230 volts 12 Watt LED light fixing on wall/ceiling and connecting with twin core copper conductor FR-LSH cable etc complete all as specified and directed.
Supply and Fixing in repair LED flameproof light in replacement Flame proof 1X16 Watt, 4' long with die cast alluminium housing with heat resistance toughten glass with LED tube light fixture driver, holder, connector etc prewired including connecting up with 3 core copper cable in steel flexible pipe complete all as specified and directed.
S&F in repair PVC Rectangular box with 5A flush type 2 in 1 switch socket combination complete all as specified and directed.
S&F in repair PVC Rectangular box with 15A flush type 2 in 1 switch socket combination 240 V complete all as specified and directed.
Supply and Fixing in place of unserviceable aviation obstruction light with light dependent sensor, IP-65 protected steel pipe, aluminium alloy housing,red coloured polycarbonate dome and accessories complte all as specified and directed.
Dismantling and disconnecting all electrical and mechanical connection of existing siren system for taking out unserviceable/burnt motor of capacity upto 7.5 HP,3 phase,415 Volt ,50 Hz for rewinding, servicing, testing and refixing the same complete all as specified and directed.
Beenu Co. Company
star electricals
L C ASSOCIATES
M/S SOLANKI GENERAL SUPPLIERS
BHARAT CONSTRUCTION AND SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .