AE,LID AND EW, PERUMANNA GP, KOZHIKODE
AE,LID AND EW, PERUMANNA GP, KOZHIKODE
Chenapparakunnu Drinking Water Scheme Change of Motor under Perumanna Panchayath-Change of Motor - Electrical
2024_LSGD_646643_15
AE/LSGD/PMN/23-24/T13
Open Tender
Civil Works - Roads
Item Rate
120 days
PERUMANNA GP
Please refer Tender documents.
9 documents required · 9 mandatory
₹555
Yes
₹6,054
Yes
16 Mar 2024
20 Jan 2024
31 Jan 2024
20 Jan 2024
30 Jan 2024
20 Jan 2024
Amount
Electrical
90.6.6.4:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.6 sq mm
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.24.6:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.6 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Cylinderical Type Capacitor suitable for direct connection to motors.
90.14.28.5:S & F Motor starters of the following ratingsSemiautomatic star delta starter for 15 to 20HP motor
90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.1.4:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required4.00 mm copper conductor ( 8 SWG)
90.16.5.2:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.65 mm (12 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
90.16.5.4:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.00 mm (8 SWG)
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.17.1:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1 x 1.5 sq. mm
1.17.31:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 6 sq. mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
5.9:Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required.(Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm)
OD186351/2023-2024:Removing the Star/Delta starter from the existing panel board and fixing the same in the newly fabricated panel board
OD186352/2023-2024:Supplying and fixing 12W LED bub GM or equivalent make, Lumens greater than 1200Lm
OD186354/2023-2024: Supply and fixing of 50mm PVC bend
OD186356/2023-2024:Cutting the existing 63mm supply line and jointing the new line using bend and coupler
OD186357/2023-2024:Supplying and fixing 50 mm dia medium class GI pipe for supporting the delivery pipe on the top of the well
OD186358/2023-2024:Dismantling and removing the existing old, damaged and rusted Meter Board including Main Switch. Handing over the same to Municipal/ Panchayath authorities. Make good the wall including plastering and painting
OD186359/2023-2024:Supply and fixing 50mm Full way wheel valve(GM)-Zoloto
OD186360/2023-2024:Supply and providing 50mm NRV -Zoloto
OD186361/2023-2024:Supply and installation of 40amps DP isolator
OD186362/2023-2024:Supply and fixing Red, Yellow, blue LED indicator, AC/DC as required.
OD186363/2023-2024:Supply and fixing of 63mm to 51mm PVC reducer
OD186364/2023-2024:Supply and fixing 100A,HRC fuse with 100A fuse link with connections, in the existing meter board
OD186365/2023-2024:Supply and installation of dust and vermin proof , 3 phase Syntax Meter Board(GS-MB-6535) 650x350x250 size and to fix KSEB meters, fuse units CTs etc as required invludig fixing on wall,making good the damages Color painting etr... as required
OD186366/2023-2024:Supply and fixing 10mm size stainless steel rope
OD186367/2023-2024:Supply and fixing 12mm size nylon rope
OD186368/2023-2024:Supply and providing 50mm ASTM flange set
OD186369/2023-2024:Supply, treading,laying and joining of 50mm size 80sedulous ASTM pipe approved make with required specials as delivery pipe using required leak proofing materials etc as required
OD186370/2023-2024:Supply and providing 25 x 3 Brass bolt and nut with washer
OD186371/2023-2024:Supply and providing 25 x 6 Brass bolt and nut with washer
OD186372/2023-2024:Providing and fixing 2 x 25 x 3mm GI strip test joint for earthing system
OD186374/2023-2024:Supply and fixing single phase and dry run preventer
OD186375/2023-2024:Supply and fixing Digital multi functional meter
OD186376/2023-2024:Supply and fixing suitable Neutral Link on Meter Board or any other convenient location
OD186533/2023-2024:Supply installation testing and commissioning of 20 HP vertical open well submersible pump set at rated voltage 3 phase 415V 50 Hz AC supply with a maximum head of 175m , discharge 500 LPM at 118m head in the existing open well using suitable tools and plants. Deccan make 20DG/8 model Deccan or equivalent make.
OD188129/2023-2024:Supplying and fixing flat iron clamps made of 40x6mm flat iron clamp of 40cm with suitable size bolt and nut for fixing delivery pipe on the top of the well as required
OD188130/2023-2024:Supplying and fixing 100A , 2 way neutral links mounted on DMC/SmMC base with connections, in the existing meter board
OD281934/2023-2024:Dismantling and removing the existing old damaged pump up to 20 HP including foundation bolts . Handing over the same to Municipal/ Panchayath authorities. Make good the surface including plastering and painting as required
sihesh k
Bidder Name
NISARI SOUNDS AND ELECTRICALS
sihesh k
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .