Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹9.1 L+₹14,000 (1.57%)Rejected-Finance 1 128 A SECOND FLOOR MOHAMMADPUR NEAR BHIKAJCAMA PLACE NEW DELHI 110066 | NEW DELHI | NEW DELHI | DELHI | 110066 | L2 | Rejected-Finance Other than lowest | |
| 3 | Rejected-Technical | - | Rejected-Technical Not enlisted in appropriate Category |
| Sl No | Description | Qty | Unit | M/s Dhapola Elevator and Engineering L2 | trinity construction L1 |
|---|---|---|---|---|---|
| 1.00 | Comprehensive, preventive and periodical maintenance of 01 Nos electrically operated OTIS make passenger lift of capacity 2000 kgs, suitable for serving G+3 Floors (total 03 landings) 1 No Lift FOR ONE YEAR with electric power operated doors, auto electric levelling device complete with ARD facility installed at NHO to be maintained round the clock as described here-in-after in reliable,Contractor/ OEM will use trained and appropriately skilled personnel which it directly employs and/or supervises. They will be qualified to keep the equipment properly adjusted and they will use all reasonable care to maintain the equipment in efficient, reliable and safe operating condition. contractor / OEM will in accordance with the terms hereof, regularly examine, lubricate and adjust the equipment and generally carry out planned maintenance in a systematic and controlled manner using OEM developed techniques and expertise. The frequency of examination will depend on the type of equipment and its location. . Repair or Replace Parts: OEM will at its option, repair or replace any parts detailed in the following section 1.02 which, in its opinion are defective. Parts will be furnished by contractor / OEM on an exchange basis under which the replaced parts become the property of contractor / OEM. However contractor / OEM will not make any replacements, renewals, or repairs necessitated by any obsolete or discontinued part of the Unit(s) or by reason of any cause beyond our control (except ordinary wear and tear) including, but not limited to, fire, explosion, theft, floods, water, weather, earthquake, vandalism, misuse, Civil works, improper earthing, improper or temporary power supply, or repairs by others complete all as specified. | 1 | Each Job | 2,15,000 ₹2,15,000 | 1,50,000 ₹1,50,000 Lowest |
| 1.01Notes for ser item Nos 1 (i) The tenderer shall have to replace the U/s materials within the OEM materials only. Necessary paid vouchers shall be submitted from OEM for the materials like ARD, drive, etc. | |||||
| 1.02(i). Renew all wire ropes and chains (where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cables and hoist way and machine room elevator wiring. ii. Systematically examine and adjust the following components: Machine & its subassemblies, Motor & Windings, encoder, Worm Gears & shaft, Bearings, Main & deflector, secondary Sheaves, Brake coils, liners and related assembly Ropes or Coated Steel Belts (CSB) & associated parts including spring /rubber/thimble Controller parts-Circuit breakers, fuses, Connectors, switches, Relays & Contactors, PCBs, Resistors, Line reactor, Line filter, Capacitors, Rectifiers, Transformers, Contacts, VF Drive & braking unit. Automatic Rescue device parts like printed circuit board, transformers, circuit breakers, contactor relays Selector system subassemblies like Levelling Devices, Cams, Relays, Rectifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mechanical and Electrical Driving Equipment Governor, Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws; Governor Tension Sheave Assembly Car and Hall push Buttons, Car and Hall Position Indicators, 7 or 16 Segment displays or TFT & Small Monochrome displays Hall Lanterns bulbs or PCB's, Car Direction Indicators and all other Car and Landing Signal Fixtures, as installed by Otis Otis Intercom, emergency light and alarm unit including battery, Emergency & Inspection control panel parts like PCB's, circuit breakers, Fireman switch excluding the glass Car and Counterweight - Sheaves, Bearings, Car and Counterweight Guide Rails and Buffers, brackets, Car and Counterweight Guide shoes including Roller or Liner, Top and Bottom Limit Switches, Stop switches, Compensating Sheave, compensation ropes/chains, Position reference system door zone sensors/ Magnets/vanes, Load Weighing sensors Cabin Safety Mechanism and Cabin bottom Platform Interlocks on Landing Door, Car & Landing Door Hangers, Guides, Automatic Power Operated Door Operator including VF drive, Car Door Contact, Mechanical Safety Shoe, 2D electronic door sensor iii. Furnish lubricants compounded to Otis' specifications. iv. Examine periodically all safety devices and governors and make all customary safety tests | |||||
| 1.03Contractor / OEM will during the term of this contract maintain, a reasonable supply of frequently used replacement parts and lubricants selected by OEM to meet the specific requirements of the units. Contractor /OEM further agrees to maintain a supply of major components in its National Service Centre available for express delivery in case of emergencies. Availability and delivery of spare parts inventory is subject to the market conditions and availability | |||||
| 1.04Contractor / OEM will perform an annual survey of the equipment to verify that it conforms to Otis requirements. OEM will also conduct periodic field audits of its personnel to maintain quality standards. Otis field engineers will provide technical assistance, technical information, and code consultation to support its maintenance organization. | |||||
| 1.05Contractor / OEM will periodically examine safety devices and governor of the equipment to ensure user safety. in addition, Otis will conduct an annual no load safety test on the equipment. Otis will endeavor in its service, repair and manufacturing facilities to restore the Equipment to normal services. | |||||
| 1.06contractor / OEM will maintain current Otis engineering wiring diagram for the term of this Agreement and the same will be used exclusively by examiners or authorised OEM representatives | |||||
| 1.07Chargeable Call Backs: contractor / OEM also reserves the right to charge the Customer for Call Backs when such Call Backs are the result of negligence or misuse of the Equipment or by reason of any cause which is beyond Otis' control, such as, Power failure, false calls, vandalism, misuse, Civil works, improper earthing/ temporary power supply, Customer security access system or repairs by others. | |||||
| 2.00 | S&F VVVF drive of capacity 15 KW for lift 2 Ton Cap complete all as specified & directed. | 1 | Nos | 1,65,000 ₹1,65,000 Lowest | 4,05,000 ₹4,05,000 |
| 3.00 | Comprehensive, preventive and periodical maintenance of 02 Nos electrically operated OTIS make passenger lift of two numbers capacity 884 kgs carrying, 13 passengers suitable for serving G+5 Floors (total 05 landings) 2 Nos Lift FOR ONE YEAR with electric power operated doors, auto electric levelling device complete with ARD facility installed at Mandakini complex to be maintained round the clock as described here-in-after in reliable, Cotractor OEM will use trained and appropriately skilled personnel which it directly employs and /or supervises. They will be qualified to keep the Equipment properly adjusted and they will use all reasonable care to maintain the Equipment in efficient, reliable and safe operating condition. .Planned Maintenance: contractor / OEM will in accordance with the terms hereof, regularly examine, lubricate and adjust the Equipment and generally carry out planned maintenance in a systematic and controlled manner using OEM developed techniques and expertise. The frequency of examination will depend on the type of equipment and its location. OEM will at its option, repair or replace any parts detailed in the following section 4.02 which, in its opinion are defective. Parts will be furnished by contractor / OEM on an exchange basis under which the replaced parts become the property of contractor / OEM. However contractor / OEM will not make any replacements, renewals, or repairs necessitated by any obsolete or discontinued part of the Unit(s) or by reason of any cause beyond our control (except ordinary wear and tear) including, but not limited to, fire, explosion, theft, floods, water, weather, earthquake, vandalism, misuse, Civil works, improper earthing, improper or temporary power supply, or repairs by others complete all as specified and directed. | 2 | Each Job | 2,15,000 ₹4,30,000 | 1,50,000 ₹3,00,000 Lowest |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
22 Jun 2026, 6:00 pmClosed
CWE Hills Dehradun
HQ CWE Hills Mall Road Dehradun Cantt 248003
COMPREHENSIVE MAINTENANCE OF 2000 KG GOODS LIFT AND 2 NOS PASSENGER LIFT AT MANDAKINI COMPLEX AND NHO UNDER GE CLEMENT TOWN
2026_MES_768554_1
85462/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
GE Clement Town
Class E Cat C (ii)
6 documents required · 6 mandatory
₹500
Yes
GE Clement Town Dehradun
₹20,000
Yes
23 Jul 2026
29 May 2026
30 Jun 2026
29 May 2026
22 Jun 2026
16 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Comprehensive, preventive and periodical maintenance of 01 Nos electrically operated OTIS make passenger lift of capacity 2000 kgs, suitable for serving G+3 Floors (total 03 landings) 1 No Lift FOR ONE YEAR with electric power operated doors, auto electric levelling device complete with ARD facility installed at NHO to be maintained round the clock as described here-in-after in reliable,Contractor/ OEM will use trained and appropriately skilled personnel which it directly employs and/or supervises. They will be qualified to keep the equipment properly adjusted and they will use all reasonable care to maintain the equipment in efficient, reliable and safe operating condition. contractor / OEM will in accordance with the terms hereof, regularly examine, lubricate and adjust the equipment and generally carry out planned maintenance in a systematic and controlled manner using OEM developed techniques and expertise. The frequency of examination will depend on the type of equipment and its location. . Repair or Replace Parts: OEM will at its option, repair or replace any parts detailed in the following section 1.02 which, in its opinion are defective. Parts will be furnished by contractor / OEM on an exchange basis under which the replaced parts become the property of contractor / OEM. However contractor / OEM will not make any replacements, renewals, or repairs necessitated by any obsolete or discontinued part of the Unit(s) or by reason of any cause beyond our control (except ordinary wear and tear) including, but not limited to, fire, explosion, theft, floods, water, weather, earthquake, vandalism, misuse, Civil works, improper earthing, improper or temporary power supply, or repairs by others complete all as specified. | 1 | Each Job | 33.5 | ₹33.5 |
| 1.02 | (i). Renew all wire ropes and chains (where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cables and hoist way and machine room elevator wiring. ii. Systematically examine and adjust the following components: Machine & its subassemblies, Motor & Windings, encoder, Worm Gears & shaft, Bearings, Main & deflector, secondary Sheaves, Brake coils, liners and related assembly Ropes or Coated Steel Belts (CSB) & associated parts including spring /rubber/thimble Controller parts-Circuit breakers, fuses, Connectors, switches, Relays & Contactors, PCBs, Resistors, Line reactor, Line filter, Capacitors, Rectifiers, Transformers, Contacts, VF Drive & braking unit. Automatic Rescue device parts like printed circuit board, transformers, circuit breakers, contactor relays Selector system subassemblies like Levelling Devices, Cams, Relays, Rectifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mechanical and Electrical Driving Equipment Governor, Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws; Governor Tension Sheave Assembly Car and Hall push Buttons, Car and Hall Position Indicators, 7 or 16 Segment displays or TFT & Small Monochrome displays Hall Lanterns bulbs or PCB's, Car Direction Indicators and all other Car and Landing Signal Fixtures, as installed by Otis Otis Intercom, emergency light and alarm unit including battery, Emergency & Inspection control panel parts like PCB's, circuit breakers, Fireman switch excluding the glass Car and Counterweight - Sheaves, Bearings, Car and Counterweight Guide Rails and Buffers, brackets, Car and Counterweight Guide shoes including Roller or Liner, Top and Bottom Limit Switches, Stop switches, Compensating Sheave, compensation ropes/chains, Position reference system door zone sensors/ Magnets/vanes, Load Weighing sensors Cabin Safety Mechanism and Cabin bottom Platform Interlocks on Landing Door, Car & Landing Door Hangers, Guides, Automatic Power Operated Door Operator including VF drive, Car Door Contact, Mechanical Safety Shoe, 2D electronic door sensor iii. Furnish lubricants compounded to Otis' specifications. iv. Examine periodically all safety devices and governors and make all customary safety tests | - | - | - | - |
| 1.03 | Contractor / OEM will during the term of this contract maintain, a reasonable supply of frequently used replacement parts and lubricants selected by OEM to meet the specific requirements of the units. Contractor /OEM further agrees to maintain a supply of major components in its National Service Centre available for express delivery in case of emergencies. Availability and delivery of spare parts inventory is subject to the market conditions and availability | - | - | - | - |
| 1.04 | Contractor / OEM will perform an annual survey of the equipment to verify that it conforms to Otis requirements. OEM will also conduct
periodic field audits of its personnel to maintain quality standards. Otis field engineers will provide technical assistance, technical information, and code consultation to support its maintenance organization. | - | - | - | - |
| 1.05 | Contractor / OEM will periodically examine safety devices and governor of the equipment to ensure user safety. in addition, Otis will
conduct an annual no load safety test on the equipment. Otis will endeavor in its service, repair and manufacturing facilities to restore the Equipment to normal services. | - | - | - | - |
| 1.06 | contractor / OEM will maintain current Otis engineering wiring diagram for the term of this Agreement and the same will be
used exclusively by examiners or authorised OEM representatives | - | - | - | - |
| 1.07 | Chargeable Call Backs: contractor / OEM also reserves the right to charge the Customer for Call Backs when such Call Backs are the result of negligence or misuse of the Equipment or by reason of any cause which is beyond Otis' control, such as, Power failure, false calls, vandalism, misuse, Civil works, improper earthing/ temporary power supply, Customer security access system or repairs by others. | - | - | - | - |
| 2 | S&F VVVF drive of capacity 15 KW for lift 2 Ton Cap complete all as specified & directed. | 1 | Nos | - | - |
| 3 | Comprehensive, preventive and periodical maintenance of 02 Nos electrically operated OTIS make passenger lift of two numbers capacity 884 kgs carrying, 13 passengers suitable for serving G+5 Floors (total 05 landings) 2 Nos Lift FOR ONE YEAR with electric power operated doors, auto electric levelling device complete with ARD facility installed at Mandakini complex to be maintained round the clock as described here-in-after in reliable, Cotractor OEM will use trained and appropriately skilled personnel which it directly employs and /or supervises. They will be qualified to keep the Equipment properly adjusted and they will use all reasonable care to maintain the Equipment in efficient, reliable and safe operating condition. .Planned Maintenance: contractor / OEM will in accordance with the terms hereof, regularly examine, lubricate and adjust the Equipment and generally carry out planned maintenance in a systematic and controlled manner using OEM developed techniques and expertise. The frequency of examination will depend on the type of equipment and its location. OEM will at its option, repair or replace any parts detailed in the following section 4.02 which, in its opinion are defective. Parts will be furnished by contractor / OEM on an exchange basis under which the replaced parts become the property of contractor / OEM. However contractor / OEM will not make any replacements, renewals, or repairs necessitated by any obsolete or discontinued part of the Unit(s) or by reason of any cause beyond our control (except ordinary wear and tear) including, but not limited to, fire, explosion, theft, floods, water, weather, earthquake, vandalism, misuse, Civil works, improper earthing, improper or temporary power supply, or repairs by others complete all as specified and directed. | 2 | Each Job | - | - |
| 3.02 | (i) . Renew all wire ropes and chains (where fitted) as often as required to maintain an adequate factor of safety, to equalize the tension on all hoisting ropes, repair or replace conductor cables and hoist way and machine room elevator wiring. ii. Systematically examine and adjust the following components: Machine & its subassemblies, Motor & Windings, encoder, Worm Gears & shaft, Bearings, Main & deflector, secondary Sheaves, Brake coils, liners and related assembly Ropes or Coated Steel Belts (CSB) & associated parts including spring /rubber/thimble Controller parts-Circuit breakers, fuses, Connectors, switches, Relays & Contactors, PCBs, Resistors, Line reactor, Line filter, Capacitors, Rectifiers, Transformers, Contacts, VF Drive & braking unit. Automatic Rescue device parts like printed circuit board, transformers, circuit breakers, contactor relays Selector system subassemblies like Levelling Devices, Cams, Relays, Rectifiers, Transformers, Contacts, Leads, Dashpots, Timing Devices, Steel Selector Tapes and Mechanical and Electrical Driving Equipment Governor,Governor Sheave, Shaft Assembly, Bearings, Contacts and Governor Jaws; Governor Tension Sheave Assembly Car and Hall push Buttons, Car and Hall Position Indicators, 7 or 16 Segment displays or TFT & Small Monochrome displays Hall Lanterns bulbs or PCB's, Car Direction Indicators and all other Car and Landing Signal Fixtures, as installed by Otis Otis Intercom, emergency light and alarm unit including battery, Emergency & Inspection control panel parts like PCB's, circuit breakers, Fireman switch excluding the glass Car and Counterweight - Sheaves, Bearings, Car and Counterweight Guide Rails and Buffers, brackets, Car and Counterweight Guide shoes including Roller or Liner, Top and Bottom Limit Switches, Stop switches, Compensating Sheave, compensation ropes/chains, Position reference system door zone sensors/ Magnets/vanes, Load Weighing sensors Cabin Safety Mechanism and Cabin bottom Platform Interlocks on Landing Door, Car & Landing Door Hangers, Guides, Automatic Power Operated Door Operator including VF drive, Car Door Contact, Mechanical Safety Shoe, 2D electronic door sensor iii. Furnish lubricants compounded to Otis' specifications. iv. Examine periodically all safety devices and governors and make all customary safety tests | - | - | - | - |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.33 MB
Tender85462.pdf
Tender Documents • 1.10 MB
BOQ_860689.xls
BOQ • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .