Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC 9 SHUBHASH BHAWAN RAJENDAR MARG MOUNT ABU 307 501 | MOUNT ABU | SIROHI | RAJASTHAN | 307501 | L1 | Accepted-AOC Accepted being lowest rate qouted | |
| 2 | L2₹20.5 L+₹19,075.60 (0.94%)Rejected-AOC | L2 | Rejected-AOC Not accepted since higher rate qouted | |
| 3 | L3₹20.6 L+₹24,703.60 (1.22%)Rejected-AOC 106 AGARWAL AND COMPANY PROFESSOR COLONY OPP OF WALL FORT CITY RING ROAD NO 01 RAIPUR CHHATTISGARH 492001 | RAIPUR | CHHATTISGARH | 492001 | L3 | Rejected-AOC Not accepted since higher rate qouted | |
| 4 | L4₹20.8 L+₹46,634 (2.29%)Rejected-AOC | L4 | Rejected-AOC Not accepted since higher rate qouted | |
| 5 | Rejected-Technical | - | Rejected-Technical Not accepted |
Tender Value
₹19.8 L
EMD Value
₹39,500
Closing Date
23 Apr 2020, 6:00 pmClosed
GE ARMY GANDHINAGAR
GE GANDHINAGAR PO BSF CAMPUS GANDHINAGAR 382045
SPECIAL REPAIRS TO ROOF TREATMENT IN BLDG NOS. P 38 P 80 AND P 348 AT MIL STN GANDHINAGAR
2020_MES_336700_1
GE(A)/GNR/TOKEN/72 of 2019-20
Open Tender
Civil Works
Fixed-rate
180 days
MIL STN GANDHINAGAR
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
Yes
GE ARMY GANDHINAGAR
₹39,500
Yes
30 Jul 2020
28 Mar 2020
25 Apr 2020
28 Mar 2020
23 Apr 2020
10 Apr 2020
28 Mar 2020 - 9 Apr 2020
Amount
Removing rubbish to a distance exc. 1.5 Km but not exc. 5.0 KM out side MD land complete all as specified and directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate for padestal/coping around poles, including necessary form work, finishing even and smooth without using extra cement, all as specified and directed.
M&L for 35mm thick precast cement concrete (1:2:4) type B-0 using 12.5mm graded stone aggregate as in louvers or jallies (measured solid), including all mouldings and precast cement concrete 1:2:4 type B-0, pillars/supports to jallies, set in cmenet mortar (1:4) complete all as specified and directed.
M&L for cutting uneven surfaces of concrete & cutting reinforcement from drops of fins & facias (thickness not exceeding 50mm) using necessary scaffolding and making good the disturbed portion with 10mm thick rendering in CM 1:3 finished even and smooth without using extra cement etc. complete all as specifeid and directed.
Removing existing water proofing /black top treatment except concrete padding ruighing of concrete surface cleaning and washing down the surface with water and removing debrish/rubbish material to a distance exc. 1.5 Km but not exc. 5.0 Km out side Md land complete all as specified and directed.
M&L for screed bed 15mm thick on fair faces of concrete surface in cement mortar (1:3) mixed with using water proofing compound by weight of cement as per manufacturer instructions, finished even and smooth without using extra cement for laying APP membrane at non -accessible roof (mumty) complete all as specified and directed. Note:- Supply only liquid water proofing compound shall be measured and paid separately.
Preparation for water proofing treatment to roof slab by applying one coat of cold bituminous primer @ 0.30 litre/sqm and confirming to IS-3384, laying APP based polystr modified membrane reinforced non wooven polyster of 3.50 kg/sqm (minimum) 3mm thick with plain polythene finished and sealing all the overlap 75mm in length side and 100mm in width side of membrane by torching including applying one coat of bituminous aluminium paint over membrane all as specified and directed.
Supply only, liquid water proofing compound complete all as specified and directed.
M&L for Brick work with old size, sub class 'B' bricks, straight or curved on plan exc. 6m mean radius built in cement mortar 1:6 complete all as specified and directed.
S&F, 0.63mm thick plain galvanized mild steel sheeting in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as sp[ecified and directed.
M&L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3, all as specified and directed.
Taking down cement plaster on brick or stone wall etc. including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for rendering cement plaster 10mm thick in cement mortar (1:6) on brick work or concrete surfaces of walls, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering cement plaster 5mm thick in cement mortar 1:4 on fair faces of concrete in ceilings, chajjas, fins facia etc. finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of white cement as primer complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper over and including chalk whiting on walls complete all as specified and directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
Taking up or down steel tubing and connections for 15mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 20mm bore of pipe complete all as specified and directed.
Taking up or down steel tubing and connections for 25mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 15mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 20mm bore of pipe complete all as specified and directed.
S&F, steel water tubes, medium grade, galvanized, with all fittings and fixed to walls and ceilings or laid in floors for 25mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 15mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 20mm bore of pipe complete all as specified and directed.
Refixing old serviceable steel tubing and connections in new or old position (walls, ceilings, floors etc.) for 25mm bore of pipe complete all as specified and directed.
Hoisting, fixing in position and connecting, in repairs, 1000 litres capacity rotational moulded polyethylene water storage tank (cylindrical, vertical with closed top) including fixing arrangement for inlet/outlet/over flow and vent pipe of standard size all as specified in SSR Part-I complete all as specified and directed.
Disconnecting, setting aside (or lowering if required) and Cleaning & removing all scale and dirt etc from HDPE water tanks of 1000 litres capacity (Tanks placed on top of roof) and from mouths of circulating pipes etc including washing the tank with bleaching powder and hoisting, reconnecting and re-fixing in position including writing the date of cleaning of tank with synthetic enamel (black/white) paint of size not less than 10cm of each letter complete, all as specified and directed.
S&F, in repair, 20mm bore, ball valves high pressure of PTMT with epoxy coated aluminium rod & high-density plastic ball screwed for iron pipe and fixed complete all as specified and directed.(Minimum weight -210 Gms)
S&F, 75mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F, 110mm bore PVC (SWR) pipes, single socketed in any length with rubber ring joints fixed to walls including stack clamp complete all as specified and directed.
S&F, 75mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
S&F, 110mm bore PVC (SWR) bend, any radius with access door complete all as specified and directed.
Demolition of brick work or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars etc. complete all as specified and directed.
M&L for demolition of reinforced cement concrete of manhole cover/RCC roof tank etc complete all as specified and directed.
Dismantling of cast iron, PVC or reinforced concrete drain pipes jointed in cement mortar for 110mm and 75mm bore of pipe from wall/floors etc complete all as specified and directed.
Shree Builders
Agarwal and Company
Ramdev and Sons
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .