| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.3 LAccepted-AOC ABM HOUSE CHEMBUMUKKU THRIKAKKARA P O KOCHI 682021 | KOCHI | ERNAKULAM | KERALA | 682021 | L1 | Accepted-AOC aoc | |
| 2 | L2₹16.9 L+₹55,892 (3.42%)Rejected-Finance CHEMBISSERY PUTHIYAKAVU TRIPUNITHURA P O KOCHI 682301 | ERNAKULAM | KERALA | 682301 | L2 | Rejected-Finance NOT BEING L1 | |
| 3 | L3₹20.1 L+₹3.8 L (23.2%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L3 | Rejected-Finance NOT BEING L1 | |
| 4 | L4₹22.9 L+₹6.5 L (40.1%)Rejected-Finance 40 608A PULLOMPARAMBLI HOUSE MANDAKKARA ROAD KOCHI 682 018 | KOCHI | ERNAKULAM | KERALA | 682018 | L4 | Rejected-Finance NOT BEING L1 |
Tender Value
₹17.2 L
EMD Value
₹34,400
Closing Date
24 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R AND D KOCHI
AGE I R AND D KOCHI, THRIKKAKARA,KAKKANAD, KOCHI 682021
PROVISION OF ADDITIONAL 3 PHASE POWER SUPPLY TO INSTRUMENTATION ROOM AT MAIN TANK OF T COMPLEX, NPOL, KOCHI
2022_MES_548031_1
8148E8AGERDK
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KAKKANAD
As per tender doucments
6 documents required · 6 mandatory
₹500
Yes
AGE I R AND D KOCHI
₹34,400
Yes
15 May 2025
26 Aug 2022
26 Sept 2022
26 Aug 2022
24 Sept 2022
10 Sept 2022
Amount
Supply, install, test and commissioning of outdoor type double door LT Feeder pillar box made out of 3.0 mm thick CRCA sheet outdoor type totally enclosed weather dust and vermin proof as per IS, CPRI Approved with front opening suitable locking arrangement having copper bus bar of 750 Amp capacity for RYB and half for neutral and insulated with insulators, including connecting incoming and outgoing cables necessary PCC 1:3:6 C1 (using 20mm aggregate) foundation and made out of 50 mm x 50 mm x 6 mm angle iron grouted at ground above 30 cm from ground level comprising of the following complete all as specified and directed by Engineer-in-Charge. Note: Cost of necessary internal wiring from bus bar to MCCBs/MCBs/Enclosure connections etc shall be deemed to be included in the unit rate.
Incoming:
(a) MCCB 500 Amp 4P, 415 Volt 36 KA, Ics=100% of Icu with spreader & rom -01 No. Make: Legrand/L & T/Siemens/Havells. (b) Indicating Lamp Red/Yellow/Blue - 03 Nos (c) SP MCB 6A -03 Nos (d) MFM Meter with CT- 01 No
Outgoings.
(a) 160 Amp 4P MCCB, 415 Volt 36 KA, Ics=100% of Ics with spreader & rom -04 Nos. Make: Legrand/L & T/Siemens/Havells. (b) 125 Amp 4P MCCB, 415 Volt, 25 KA, Ics=100% of Ics with spreader & rom -01 No. Make: Legrand/L & T/Siemens/Havells. (c) 32 Amp 4P MCB 415 Volt, 10 KA, Ics=100% of Ics with spreader & rom -01 No. Make: Legrand/L & T/Siemens/Havells.
M&L for extending the existing LT panel board at LT substation above Central AC Plant of Main Lab with 2.0 mm thick CRCA sheet Factory made Indoor type totally enclosed weather dust and vermin proof as per IS, CPRI Approved, with front and rear opening suitable locking arrangement with necessary copper bus bar of capacity 1060 Amps with necessary supporting insulators so as to match with the existing LT panel board/ Distribution panel by connecting to existing bus bar by using rigid copper bus bar by opening the one side of existing panel /bus bar including necessary supporting frame /channel fix through existing cable trench from ground with comprising of the followings:-
(a) ACB 630 Amp 4P, 415 Volt, 50 KA with microprocessor based SR18G+D (LSING = Current Metering+ ZSI), Short-circuit breaking capacity Ics =100% of Icu with (Including necessary tools/kits as required at site. Make: Legrand/L & T/Siemens/Havells. (b) Provision for outgoing cable of size up to 400 Sqmm from the extended portion of LT distribution panel
Note for SI Item No 01& 02. Contractor has to submit the drawing for LT panel board before commencement of work and get it approval from Accepting officer.
The contractor has to take the shutdown from the MRS 11 KV Sub Station at technical area with prior permission for extending of Main LT Panel at Sub stations.
The contractor shall clean the existing LT Panel before the making connections from existing LT Panel to extending new LT Panel after the shut down.
S& F Industrial surface/wall mounting socket 125 Amp 4 pole with straight/angle plug 125 Amp 4 Pole + E400 V IP 67 protection and sockets enclosure as PLEXO3 cabinet IP 65 protection 8 MOD fixed on wall with including incomming MCB TPN 125 Amp FP all as specified and as directed Make: Legrand/L & T/Hensel/Siemens.
M&L for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 Volts grade, in trenches/fixed on wall of following cross-sectional area complete all as specified and as directed. Note (i) Rate include the cost of lug of proper size and cable gland
(ii) Necessary Excavation, PCC cover and sand cushioning shall be measured &paid separately
(a) Cable of size 400 sq mm 3.5 core
(b) Cable of size 95 sq mm 3.5 core
(c) Cable of size 70 sq mm 3.5 core
Excavation in trenches not exceeding 1.5 mtr deeep and 1.5 mtr width as in soft/loose soil complete all as specified
Returning filling incl leveling watering and well ramming in layer not exceeding 25cm thick complete all as specified& directed by Engineer-in-Charge.
Removal of surface soil to a distance n.exc 50m and deposited where directed at a level n.exc1.5 m above the starting point complete all as directed.
Supply & Laying sand for cushioning for cable protection in trenches 8 cm before laying cable and 15 cm deep over the cable (Note: Punned thickness shall be taken for measurement )
Supply and lay unreinforced precast cement concrete cable cover for protection of underground cable in trenches class LV flat size 250 mm x 150 mm x 40 mm complete all as specified
M&L for Earthing complete with using copper earth plate 600 x 600 x 3.15 mm thick electrode, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level connected to 20 mm x 3 mm copper strip as earth lead by means bolts, nuts, check nuts and washers all as shown in electrical plate No.3 connected to earthing test point all as specified or indicated including testing on completion necessary complete all as specified and as directed. Note: Quoted rate including necessary excavation, earth work, PCC, Pit, RCC cover, funnel with watering GI pipe 20 mm bore light grade, GI protection pipe 15mm bore light grade.
Supply and lay in trenches /fixed on wall GI tubing light grade with necessary fittings such as bend, tee, elbow etc complete for the following sizes
80 mm bore
50 mm bore
M&L for PCC 1:3:6 type C2 (using 40 mm graded aggregate) complete for making PCC protection for cable path /trench all as directed by Engineer-in-Charge.
Material and Labour for cross arms. Bracings, supports ,clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat , one under aluminium coat and one aluminium finishing coat of paint complete all as specified for supporting frame for fixing the single phase enclosure and as directed by Engineer -in-Charge
M/s.Rejoy Constructions
ELAN ENGINEERS
WELTRONENGINEERINGSERVICES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .