EXECUTIVE ENGINEER, NADIAD O&M DIVISION
Erection, Dismantling and Maintenance of HT/LT Line and Transformer center at DAKOR/ anywhere under Nadiad O&M Division including cost of Bolt & Nuts
311629
NDR/Works/2026-27/12
Open
Power/Energy Projects/Products/Services
Kheda
₹1,180
MADHYA GUJARAT VIJ COMPANY LTD
₹30,000
5 Jun 2026
5 Jun 2026
5 Jun 2026
29 Jun 2026
5 Jun 2026
NO No. Nut & bolt
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,INSULATORS, ETC,
1. 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDINGERECTION OF GUY SET AND EARTHING
ERECTION OF LT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
2. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING
ERECTION OF HT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
3. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING
ERECTION STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS,
ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. COMPLETE AND
4. 9902010003 Number
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUT SET AND EARTHING.
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG/LINE FOR 0.400/11/22KV OVERHEAD LINE I.E. INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
5. 9902010004 FITTING CLAMPS, ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. Number
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS PSC POLE INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS,
6. 9902020001 INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF
CHANNELS, SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER
7. 9902020007 BOARDS, INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-VATION OF PITS
AND REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES
8. 9902020006 CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS, DO FUSES, Number
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
9. 9902020010 ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE Number
AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
10. 9902020019 ANTI-CLIMBING DEVICES , DANGER BOARDS INSULATORS, ETC COMPLETE AND Number
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF HG FUSES, 5 KVA
TRANSFORMERS, LIGHTENING ARRESTERS AND WITHOUT DISTRIBUTION BOX
ETC OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, CARTING OF TRANSFORMERS FROM STORE TO SITE,
11. 9902030021 FIXING OF CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS Number
ANTI-CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH, CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF
12. 9902030001 CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS ANTI- Number
CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO 9 &
11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF
13. 9902030024 CHANNELS, SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI Number
CLIMBING, DEVICES, DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF
14. 9902030012 CHANNELS, SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI Number
CLIMBING, DEVICES, DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF
EARTH, AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES,
ANCHOR ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK, ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF
CEMENT,AND Cubic
METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD Meter
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COIL,COAL SALT, ETC
BUT WITHOUT COST OF G I WIRE AS PER STANDARD SPECIFICATION 10 KG
17. 9902040002 Number
SOLT + 10KG COAL. FOR CONSUMER OR POLE AS PER TECHNICAL
SPECIFICATION PROVIDED WITH TENDER.
ERECTION OF GI PIPE / C I PLATE TYPE EARTHING INCLUDING COST COAL
18. 9902040003 SALT, ETC BUT WITHOUT COST OF GI PIPE / CI PLATE AS PER STANDARD Number
SPECIFICATION…20 KG SOLT + 20KG COAL.
SRTINGING OF 34MM2 ,55MM2,AAA CONDUCTOR, FOR 11 KV & L.T. LINE
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF Kilo
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN- Meter
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING Kilo
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP, Meter
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A : 1 X 35MM2 + 1 X 25MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN
AREA INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN
SUSPENSION / TENASION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN Kilo
INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC AS REQUIRED & Meter
DIRECTED BY ENGINEER-IN-CHARGE
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION /
TENASION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN Kilo
INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC AS REQUIRED & Meter
DIRECTED BY ENGINEER-IN-CHARGE
Supply and fixing Heat Shrinkable type cable joint kit suitable for 11KV 1core
X 95/70 sqmm AB cable for outoor termination application.
Supply and fixing Heat Shrinkable type straight joint kit suitable for 11KV
1core X 95/70 sqmm AB cable for outoor application.
27. 9906000002 PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING RMT
28. 9906000001 PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING RMT
29. 9901000002 LT LINE TAPPING SINGLE PHASE. Number
30. 9901000003 LT LINE TAPPING THREE PHASE. Number
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING HT LINE CROSSING
31. 9911000017 Meter
AND TELEPHONE LINE CROSSING ETC (PER SPAN)
Dismentalling of all size (8,9,11,13…mtrs.) of RSJ (girder) Poles including
32. 9907000006 dimentalling of relevant channels, cross arms insulators, jumpers, binding, Number
earthing etc. including crediting in store
Dismentalling of PSC Poles including dimentalling of relevant channels, cross
33. 9907000002 Number
arms insulators, jumpers, binding, earthing etc. including crediting in store
34. 9907000009 Dismentalling of conductor from line. including crediting in store cond
35. 9907000012 Dismentalling of PSC Pole D.P.Structure. including crediting in store Number
36. 9907000025 Dismentalling of 2 W A.B.Cable from line. including crediting in store
37. 9907000025 Dismentalling of 4 w A.B.Cable from line. including crediting in store
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
38. 9911000057 Number
ON TRANSFORMER
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC CABLE FROM
39. 9904010002 Number
TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
PROVIDING THREE PHASE FOUR WIRE SERVICE CONNECTION WITH PVC CABLE
40. 9904010001 Number
FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR
ERECTION OF POLE / GUY ETC. AS PER STANDARD SPECIFICATION OVER &
41. 9902040008 ABOVE NORMAL COST COVERED AGAINST EXCAVATION OF PIT UNDER NORMAL Number
SOIL FOR ERECTION OF POLE, GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT. ENGINEER
42. 9909000001 CARTING OF PSC POLE AT DESTINATION(ABOVE 5 KM) Number
43. 9909000006 CARTING OF RSJ POLE AT DESTINATION(ABOVE 5 KM) Number
REPLACEMENT OF FAIL TRANSFORMER & AUGMENTATION / DEAUGMENTATION
44. 9908000049 OF TRANSFORMER(ANY CAPACITY) INCLUDING TRANSPORTATION & CREDIT OF Number
OLD TRANSFORMER AT S/DN STORE
45. Unbundling & Fixing of 95 mm2/71mm2 HT ABC on existing Pole
46. 9907000031 Dismantling of HT ABC (Urban) Km
47. 9907000031 Dismantling of HT ABC (Rural) Km
48. 9907000032 Unbundling of HT ABC Km
49. Stringing of Unbundled HT ABC
50. 9911000226 Re Fixing of V cross arm Number
51. 9911000010 Re Fixing of Top fitting Number
52. Re jumpering of HT/LT Line for Shackle pole
53. 9908000166 Replacement of LT Pin/Shackle Insulator No
54. Fixing of Shackle Insulator with Hardware No
Under Ground Cable
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
EXCAVATION OF TRENCH 0.5 MTR. WIDE AND 1 MTR. DEEP FOR LAYING OF
HT/LT UNDERGROUND CABLE SIZE UPTO 300SQ. MM PILC OR XLPE (THE
CABLE SHOULD BE LAID ON BED OF SAND AND TO COVER CABLE WITH HALF
ROUND RCC PIPE 6'' INTERNAL DIA AND LENGTH OF ONE METER ALONG WITH
EACH BOTTAM AND TOP) THE ENTIRE TRENCH THERE AFTER SHOULD BE
REFILLED WITH EARTH DULLY RAMMED UP TO GROUND LEVEL AS PER DRG.
NO. MGVCL/TECH/UG CABLE/01/12-13
EXCAVATION OF TRENCH 0.75 MTR. WIDE AND 1 MTR. DEEP FOR LAYING OF
HT/LT UNDERGROUND CABLE SIZE UPTO 300SQ. MM PILC OR XLPE (THE
CABLE SHOULD BE LAID ON BED OF SAND AND TO COVER CABLE WITH HALF
56. 9913000037 ROUND RCC PIPE 6'' INTERNAL DIA AND LENGTH OF ONE METER ALONG WITH MTR
EACH BOTTAM AND TOP) THE ENTIRE TRENCH THERE AFTER SHOULD BE
REFILLED WITH EARTH DULLY RAMMED UP TO GROUND LEVEL AS PER DRG.
NO. MGVCL/TECH/UG CABLE/02/12-13
LAYING/RELAYING OF CABLE IN CABLE TRENCH AND FROM GROUND LEVEL
57. 9913000038 TO POLE STRUCTURE FOR PROVIDING OUTDOOR CABLE JOINTS MTR
Laying / Relaying XLPE/PILC cable by digging of pits,
58. 9913000039 removal of old cable and laying of new cable on sand bad as per item No.1 MTR
Widening & refilling with earth dully rammed the trench
59. 9913000016 for laying additional No. of cable. For item No.1 above. MTR
Add : Charges for digging of tar road for laying of cables
60. 9913000041 over and above digging of pit in normal soil as per Sr.No. 1. MTR
Laying of U/G 11KV XLPE cable by Push & Pull method (MANUAL / BY
Horizontal Directional MACHINE )thru with HDPE DWC pipe120mm OD &
103mm ID as per IS:14930(Part-2):2001 or 4" diameter GI Pipe without
61. 9913000042 damaging surface of the road by horizontal boring / drilling method MTR
(Excluding cost of HDPE pipe 4"GI Pipe) as per Drawing and specification
Preparig of Digital map of underground network by capturing Geographical
62. 9913000010 co-ordinates with GPS instrument(having accuracy within 1.0 mtr) and KM
superimposing the
Supply of HDPE pipe for lying 11KV XLPE cable 110mm nominal Diameter &
5.3 to 6 mm thickness as per IS:4984
SUPPLY OF HALF ROUND RCC HUME PIPE 6'' INTERNAL DIA AND LENGTH OF
SUPPLY OF MEDIUM GRADE GI PIPE OF SIZE 4'' DIA (INCLUDING CLAMPING
THE CABLE WITH POLE)
Supply of Sand 0.300X0.750X1.00 mtr (Lyer at bottom of cable trench
66. 991300050 approx.0.225cmt) as per Drg. No. MGVCL/Tech/UG Cable/02/12-13 RMTR
Only Supply Rates 11KV Indoor / outdoorvcable Box / Straight through Joints & 11KV
XLPE Alluminium, 3 Core
11KV Indoor Cable Box
67. 0411000015 185 mm2 (Rate Including Tax) NO
68. 0411000056 240 mm2 (Rate Including Tax) NO
11KV Outdoor Cable Box
69. 0411000006 185 mm2 (Rate Including Tax) NO
70. 0411000058 240 mm2 (Rate Including Tax) NO
11KV Straight through Joints
0413000020 185 mm2 (Rate Including Tax)
0411000060 240 mm2 (Rate Including Tax)
Moulding of cable joint(st.joint, indoor and outdoor) for XLPE cable-labour
charge for Urban Area
Moulding of cable joint(st.joint, indoor and outdoor) for XLPE cable-labour
charge for Rural Area
Rates For Emergency Work
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS,
CLAMPS ANTI-CLIMBING DEVICES, DANGER BOARD,INSULATORS, ETC,
75. 9901000001 COMPLETE AND PAINTING OF FABRICATED MATERIALS AND NUMBERING Number
COMPLETE WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDINGERECTION OF GUY SET AND EARTHING
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
ERECTION OF LT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
76. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING
ERECTION OF HT PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS
ANTI-CLIMBING DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF
77. 9902010001 Number
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDINGERECTION OF GUY
SET AND EARTHING
ERECTION STEEL POLES OF 8 TO 9 & 11 METERS INCLUDING EXCAVATION OF
PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS,
ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. COMPLETE AND
78. 9902010003 Number
PAINTING OF STEEL POLE, FABRICATED MATERIALS USED ON ON THE POLE
AND NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION
BUT EXCLUDING ERECTION OF GUT SET AND EARTHING.
ERECTION STEEL POLES OF 13 METERS FOR RAILWAY CROSSING ON
BG/MG/NG/LINE FOR 0.400/11/22KV OVERHEAD LINE I.E. INCLUDING
EXCAVATION OF PIT AND REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP
79. 9902010004 FITTING CLAMPS, ANTICLIMBING DEVICES DANGER BOARD, INSULATORS, ETC. Number
COMPLETE AND PAINTING OF STEEL POLES, FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS PSC POLE INCLUDING
EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARDS,
80. 9902020001 INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRUCTURE OF 8 TO 9 METERS STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH, FIXING OF
CHANNELS, SUPPORTING ANGLES , CLAMPS, ANTI-CLIMBING DEVICES DANGER
81. 9902020001 BOARDS, INSULATORS, ETC., COMPLETE AND PAINTING OF POLES FABRICATED Number
MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF PAINTS AS
PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND
EARTHING. ( W/O AB SWITCH ).
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES OF 8 METERS, 200 KG PSC POLES INCLUDING EXCA-VATION OF PITS
AND REFILLING OF EARTH, FIXING OF CHANNELS,SUPPORTING ANGLES
82. 9902020004 CLAMPS, ANTI-CLIMBING DEVICES DANGER BOARD, INSULATORS, DO FUSES, Number
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 9 & 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
83. 9902020010 ANTI-CLIMBING DEVICES , DANGER BOARDS, INSULATORS, ETC., COMPLETE Number
AND PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH /
HG FUSES, 13 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, FIXING OF CHANNELS, SUPPORTING ANGLE CLAMPS,
84. 9902020022 ANTI-CLIMBING DEVICES , DANGER BOARDS INSULATORS, ETC COMPLETE AND Number
PAINTING OF POLES FABRICATED MATERIALS USED ON THE POLES AND
NUMBERING WITH COST OF PAINTS AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF HG FUSES, 5 KVA
TRANSFORMERS, LIGHTENING ARRESTERS AND WITHOUT DISTRIBUTION BOX
ETC OF 8 METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND
REFILING OF EARTH, CARTING OF TRANSFORMERS FROM STORE TO SITE,
85. 9902020004 FIXING OF CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS Number
ANTI-CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC., COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRACTURE WITH MOUNTING OF HG FUSES,
TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX ETC. OF
86. 9902020004 Number
METERS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH, CARTING OF TRANSFORMERS, FROM STORE TO SITE FIXING OF
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
CHANNELS SUPPORTING ANGLES, BRACING CROSS ARMS, CLAMPS ANTI-
CLIMBING DEVICE DANGER BOARDS CONDUCTOR AND CABLE WIRING
ETC.,COMPLETE AND PAINTING OF FABRICATED MATERIALS USED ON THE
POLES AND NUMBERING WITH COST OF PAINTS AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF SINGLE POLE STRACTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO 9 &
11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILING OF
EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF
87. 9902030016 CHANNELS, SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI Number
CLIMBING, DEVICES, DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF A B SWITCH, HG
FUSE, TRANSFORMERS, LIGHTENING ARRESTERS, DISTRIBUTION BOX 8 TO
& 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING
OF EARTH,CARTING OF TRANSFORMERS FROM STORE TO SITE,FIXING OF
88. 9902020010 CHANNELS, SUPPORTING ANGLES, BRACING, CROSS ARMS,CLAMPS, ANTI Number
CLIMBING, DEVICES, DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF POLES FABRICATED MATERIALS USED ON
THE POLES AND NUMBERING AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF GUY SETS INCLUDING EXCAVATION OF PITS & REFILING OF
EARTH, AS PER STANDARD SPECIFICATION WITH STAY CLAMPS STAY WIRES,
ANCHOR ROD, TURN BUCKLE, EYE BOLT, GUY INSULATOR, CEMENT CONCRETE
BLOCK, ETC., BUT EXCLUDING CONCRETING.
CONCRETING/ MUFFING OF POLES GUY ETC., INCLUDING COST OF
CEMENT,AND Cubic
METAL (1:2:4) AND WATER ETC., AS PER C.C.M-20 GRADE STANDARD Meter
SPECIFICATION .
ERECTION COIL TYPE EARTHING INCLUDING COST OF COIL,COAL SALT, ETC
BUT WITHOUT COST OF G I WIRE AS PER STANDARD SPECIFICATION 10 KG
91. 9902040002 Number
SOLT + 10KG COAL. FOR CONSUMER OR POLE AS PER TECHNICAL
SPECIFICATION PROVIDED WITH TENDER.
ERECTION OF GI PIPE / C I PLATE TYPE EARTHING INCLUDING COST COAL
92. 9902040003 SALT, ETC BUT WITHOUT COST OF GI PIPE / CI PLATE AS PER STANDARD Number
SPECIFICATION…20 KG SOLT + 20KG COAL.
SRTINGING OF 34MM2 ,55MM2,AAA CONDUCTOR, FOR 11 KV & L.T. LINE
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
SRTINGING OF 100 MM2, ACSR/DOG CONDUCTOR, FOR 11 KV & L.T.LINES
INCLUDING FIXING OF INSULATORS, BINDING, JUMPERING, ETC.
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF Kilo
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN- Meter
CHARGE A: 3 X 50MM2+16MM2+1X
THE WORK OF STRINGING OF ABC OF FOLLOWING SIZES INCLUDING FITTING
OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION / TENASION CLAMP,
96. 9903000005 FIXING OF CROSS ARM, L.T. SHACKLE INSULATOR , ETC. FOR FIXING OF
MESSAGER WIRE COMPLETE, AS REQUIRED & DIRECTED BY ENGINEER-IN-
CHARGE A : 1 X 35MM2 + 1 X 25MM2
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN URBAN
AREA INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN
SUSPENSION / TENASION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN Kilo
INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC AS REQUIRED & Meter
DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X
THE WORK OF STRINGING OF 11 KV ABC OF FOLLOWING SIZES IN RURAL AREA
INCLUDING FITTING OF ALL ACCESSRIES I.E. SPECIAL DESIGN SUSPENSION /
TENASION CLAMP, FIXING OF CROSS ARM, BINDING TO PIN Kilo
INSULATOR,PREPARING SHCKLE POINT JUMPERS ETC AS REQUIRED & Meter
DIRECTED BY ENGINEER-IN-CHARGE A: 3 X95MM21X
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR
ERECTION OF POLE / GUY ETC. AS PER STANDARD SPECIFICATION OVER &
99. 9902040008 ABOVE NORMAL COST COVERED AGAINST EXCAVATION OF PIT UNDER NORMAL Number
SOIL FOR ERECTION OF POLE, GUY, DOUBLE POLE STRUCTURE EARTHING
WITH THE APPROVAL OF SUPDT. ENGINEER
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
100. 9906000002 PROVIDING GUARDING TO HT LINE ON ROAD/RAIL CROSSING RMT
101. 9906000001 PROVIDING GUARDING OF LT LINE ON ROAD/RAIL CROSSING RMT
102. 9901000002 LT LINE TAPPING SINGLE PHASE. Number
103. 9901000003 LT LINE TAPPING THREE PHASE. Number
LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC (PER SPAN)
INSTALLATION OF ENERGY METER & MMB/SMC BOX WITH ELECTRICAL WIRING
105. 9911000057 Number
ON TRANSFORMER
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC CABLE FROM
106. 9904010002 Number
TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
PROVIDING THREE PHASE FOUR WIRE SERVICE CONNECTION WITH PVC CABLE
107. 9904010001 Number
FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
N.B.: The above rates mentioned at cl. No.6 (20% higher Rates) are applicable to carry out miscellaneous emergency
work such as Cyclone, Flood, Earthquake, & Accidental damaged by vehicle, in time bound programme. It is inclusive of
dismantling & refitting line materials etc. and dismantling of damaged structure.
Rates For Maintenance Work
108. 4001000176 Patrolling of HT /LT ine per pole & submission of summary report
109. 9911000189 Cutting of tree branches obstructing HT / LT line on one tree
110. 9911000189 Cutting of bigger size of tree branches / whole tree obstructing HT / LT line Per Day
111. 9902010006 ERECTION OF SUPPORT POLE - PSC Number
112. 9902010007 ERECTION OF SUPPORT POLE - RSJ Number
REPLACEMENT OF POLE MOUNTED 1PH SERVICE CONNECTION BOX INCLUDING
113. 9911000221 Number
RECONNECTING ALL CONNECTIONS
114. 9911000229 PIN BINDING OF 11KV PIN INSULATOR
115. 9911000230 PIN BINDING OF LT LINE PIN OR SHACKLE INSULATOR
116. 9908000003 REPLACEMENT OF 11 KV DISC INSULATOR Number
117. 9908000001 REPLACEMENT OF V CROSS - ARMS Set
118. 9908000051 REPLACEMENT OF TOP FITTING Number
119. 9908000007 REPLACEMENT OF LT CROSS - ARMS Number
PROVIDING DO FUSE OR AB SWITCH ON DO (FOR ONE SET) WITH FABRICATION
120. 9908000169 & COLOUR CODE JUMPER,INCLUDING PROPER ALIGNMENT OF AB SWITCH Number
NUMBERING THE POLE WITH PAINT BY PREPARING BACK GROUND OF
REQUIRED HEIGHT SURFACE OF ONE COLOUR AND HAVE LETTERING ( 2" & 3"
121. 9911000001 HT ) AS DIRECTED BY IN CHARGE ENGINEER .THE TWO COLOUR SHOULD HAVE Number
BEEN SLECTED AS TO HAVE CONTRAST FOR PROPER READABILITY.(REQUIRED
COLOUR TO BE PROVIDED BY CONTRACTER)
FIXING OF SMC (1-Phase) AT CONSUMER INSTALLATION ( INCLUDING COST OF
122. 9911000222 Number
FIXING OF SMC (3-Phase) AT CONSUMER INSTALLATION ( INCLUDING COST OF
123. 9911000223 Number
124. 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Urban Number
125. 9908000023 REPLACEMENT OF METER (1 PH) WITH WIRING - Rural Number
126. 9911000227 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Rural Number
127. 9911000228 PROVIDING (PAINTING ) CONSUMER No ON SMC/MMB - Urban Number
REPLACEMENT OF SINGLE PHASE OLD SERVICE BY NEW SERVICE INCL
128. 9908000016 .SHORTFALL REEL INSULATORS, EGG INSULATORS, NAILS, FIXING FASTNERS Number
129. 9902040007 ERECTION/PROVIDING LIGHTENING ARRESTOR Number
REPAIRING/ADJUSTING TENSION OF EXISTING GUY/STAY SET INCLUDING
130. 9911000007 Number
PROVIDING/REPLACEMENT OF STAY INSULATOR
131. 9908000050 Refitting LA Number
132. 9911000072 Burning of Thread of LT/ HT Line including cost of Oil bamboo etc Span
Replacement of old jumpers by new jumper/binding/lugs etc. from L.A. to per
D.O fuse or D.O. fuse to T/C jumper
REPLACEMENT OF OLD DISTRIBUTION BOX 200 KVA & ABOVE WITH MAKING
134. 9908000010 Number
ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
REPLACEMENT OF OLD DISTRIBUTION BOX UP TO 100 KVA & ABOVE WITH
135. 9908000011 Number
MAKING ALL CONNECTIONS CRIMPING OF LUGS,NEUTRAL ETC
RESTRINGING OF HT/LT LINE (55/34 MM2 ) CONDUCTORS / COATED
CONDUCTOR WITH NEW DOUBLE PIN BINDING PER SPAN
Re-Stringing of 11kv Aerial Bunch Cable (All Size) per Span with accessory
138. 9911000225 Re-Stringing of Dog Conductor with new double pin binding per Span Span
139. 9911000054 Providing spacer between LT line conductor with binding etc. Number
140. 9908000460 REPLACEMENT OF 11 KV PIN INSULATOR BY NEW PIN INSULATOR Number
141. 9908000452 STRAIGHTENING OF PSC/RSJ POLE AT PIN POINT Number
SR. Item Code Rate with
Description of Work Unit
NO No. Nut & bolt
142. 9908000453 STRAIGHTENING OF PSC/RSJ POLE AT TENSION POINT Number
STRAIGHTENING OF TILTED DP SET PSC/RSJ POLE ETC WITH REFILLING OF
143. 9908000454 Number
STONE, MUROUM ETC
Estimate value
TOTAL ESTIMATE AMT. WITH GST@ 18% 29,99,193.37*
The rates are asked above only on percentage basis against estimated amount i.e. item wise
rates stated in the Schedule-B. The tender offer must be specifying the percentage either above
or, below to the estimated amount and it should be clearly specified both in figures and words.
Above quantity are approximate and may vary as per requirement.
1 Above all Rates are inclusive of Bolt and Nut. Contractor to provide Bolt Nut as per company's
specification.
2 Schedule quantity may be increase or decrease but total order value will not increase. Rates as per
Labour cost data 2024-25 considered.
3 Contractor have to carry out maintenance work of 20 % of total order value issued.
4 Note: As far as possible there should not be a situation where re carting is required for more than
Kms. Poles should be carted from Pole factory nearer to the pole requirement, However in
exceptional circumstances if re-carting is required for more than 5 Kms up to 10 Kms then the carting
rates specified may be paid with specific justification of requirement of carting for more than 5 Kms
and with prior approval of EE of division”.
5 On receipt of Sub work Order, immediately contact Engineer In charge of Concern S/dn for line
marking of erection work.
6 Work should be carried out under supervision of authorized MGVCL staff or its authorized agency
(PMA) only.
MGVCL either self or through any third-party agency including PMA whom it deems fit would
be responsible to monitor the QAM measures including verifications and inspections
mentioned above.
7 T.S wise / Work wise material account of sub works order must be given separately.
8 The materials requisition (M.R) should be collected from Concern Sub Division office.
9 "If work is delay for non-availability of any material or objection of line erection work, must be
inform to Concern S/dn office in writing."
10 For extension of time limit of work order, you have to submit written request letter with valid
genuine reason before one month.
11 On completion of work, you have to credit all balance materials to RSO-Nadiad.
12 "You have to prepare & submit works bill for Above work within 07 days with material inventory
sheet & Material account sheet & MR/CR/Gate pass copy & HT/LT/TC erected network sketch"
13 "In case of any excess work required while actual execution of work you have to give written
intimation to this office &No excess work should be carried out without prior written permission /
approval from competent authority."
14 For non -painting of RSJ Pole Rs. 1352/- charge deducted from bill amount.
15 "For non -painting of PSC Pole fabrication Rs. 166/- per pole & for PSC DODP Rs. 353/- and for
PSC TC DP fabrication Rs 721/- per DP will be deducted from bill."
16 For non-painting of Pole numbering Rs. 60/- will be deducted per pole.
17 For live electric line crossing work, work should be carried out after Power cut-off and earthing of
Seal & Sign of Executive Engineer
Contractor with Rubber Stamp MGVCL, Nadiad O&M Division