Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.9 L+₹1.0 L (20.8%)Rejected-Finance | L2 | Rejected-Finance L2 |
Tender Value
₹5.5 L
EMD Value
₹8,250
Closing Date
20 Dec 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Executive Engineer
Office of the Assistant Executive Engineer subdivision Kariavattom
electricalwork
2021_KU_460026_1
AEE II/SDB/ (e-GP)/E4./2021-2022
Open Tender
Electrical Works
Item Rate
30 days
kariavattom
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,150
₹8,250
7 Feb 2022
10 Dec 2021
23 Dec 2021
10 Dec 2021
20 Dec 2021
10 Dec 2021
10 Dec 2021 - 20 Dec 2021
120 days
Amount
Point Wiring
1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
Street Light Fittings
od147834/2021_2022 : Supply of SMD 70 W LED Streetlight fixture with System efficacy of 110 lm/W (7700 lumens). Luminaire shall be made up of die cast Aluminium housing with IP PC lens . Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 86% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.(Wipro LR13-781-XXX-57-XX /Crompton/Havells/Philips)
od147835/2021_2022 : Supply,Conveyance,Installation,Testing and Commissioning of SMD 45W LED Streetlight fixture with System efficacy of 120 lm/W (5400 lumens). Luminaire shall be made up of die cast Aluminium housing with IP PC lens . Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 86% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.(Make : Wipro Item Code:LR06-311-XXX-57-XX /Crompton/Havells/Philips)
od147836/2021_2022 : Supply Conveyance, installation, testing and commissioning of SMD 25W LED Streetlight fixture with System efficacy of 110 lm/W (2750 lumens). Luminaire shall be made up of die cast Aluminium housing with IP PC lens. Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection.IK08 for impact resistance. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 85% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the Luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.( Make : Wipro Make LR06-311-XXX-57-XX SKYLINE PLUS LED STREETLIGHT 25W / Crompton/Philips/Havells)
od147862/2021_2022 : Supply Conveyance, installation, testing and commissioning of 100 W LED Street light fixture with System efficacy of 120 lm/W (12000 lumens). Luminaire shall be made up of die cast Aluminium housing with IP PC lens . Luminaire shall be designed with street optic LENS for uniform light distribution. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. Luminaire shall be with IP66 protection. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 70. LED Driver shall be potted, Integrated type, Multistage, Isolated, APFC Constant Current-Constant Voltage operated driver with range 150-300V AC and Safety Extra Low Voltage < 60V DC as per IEC standard., Driver Efficiency > 86% & 4 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Compliance to Indian Standards of IS10322 Part 5 / Sect 1:1967; 16105 : 2012; IS 16106 : 2012; IS 15885 (Part2/Sec13) : 2012; IS 16108 : 2012.(Wipro Item Code:LR06-112-XXX-57-XX /Havells/Crompton/Philips)
Flood Light Fittings
od147828/2021_2022 : Supply Conveyance, installation, testing and commissioning of 100W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (Make Havells JETAIRISFLS100WLED757SYMLTG /Wipro/Crompton/Philips)
od147829/2021_2022 : Supply Conveyance, installation, testing and commissioning of 60W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance.(Make: Havells Jeta Quanto Plus/Crompton/Wipro/Philips)
od147830/2021_2022 : Supply Conveyance, installation, testing and commissioning of 30W LED Flood light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing, acrylic cover complete with THD less than10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance .(Make : Havells Jeta Quanto Plus/Crompton/Wipro)
Tube Light Fittings
od147831/2021_2022 : Supply of the light fittings made of CRCA sheet with 0.50 mm thickness complete with all accessories suitable for single T8 20/22 W LED tube (Make- Philips TMC 501 P 1XT-LED 22W P3241 or as per the Approved brands/ instruction by Engineer-in-charge)
od147832/2021_2022 : Supply of 20 W linear LED T8 tube (RoHS compliant) with extruded aluminium body, PC diffuser and inbuilt driver with double sided connection suitable for continuous operation on 230 V, 50 Hz AC supply and having THD <10%, power factor >0.98 etc as required. (Make- Crompton-LTT8-20, Philips or Havells)
1.41 : Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Wiring
1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
90.6.5.11 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 crore 1.50sqmm
90.6.4.1 : Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00sqmm1 run
LED Bulb
od147837/2021_2022 : Supply of BEE rated 30W LED bulb (B22 / E27) (Orient/Philips/Havels)
Bend to shape
90.3.18.3 : Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required..40mm dia with clamps made from 20x3mm MS flat
S K Electrics and Infrastructures
Bidder Name
S K Electrics and Infrastructures
SYNERGY POWER TECH
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_658400.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .