EE-I,WKED,PWDte.
New Secretariat Building, C Block, 4th floor 1, K.S Roy Road, Kolkata-700001
Air Conditioning arrangement and allied Electrical Installation work in the different Sections located in Main Building and Annex Building of the Honble High Court, Calcutta..
2026_WBPWD_5079319_1
WBPWD/EE-WKED/NIQ-94/2026-27
Open Tender
A/C ORG
Item Rate
30 days
High Court, Calcutta
Please refer Tender documents.
6 documents required · 6 mandatory
₹1.1 L
Office of the EE, WKED, PWDte.
12 Oct 2026
12 Oct 2026
30 Oct 2026
12 Oct 2026
28 Oct 2026
14 Oct 2026
14 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr (IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180v - 260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotary compressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS /International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329, capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 50 0C (out door ambient temperature). Inverter Type - Cooling only (Make-Mitshubishi Heavy Industries/O-General /Mitsubishi Electric//Daikin/Hitachi/ Voltas/ Blue Star/ Carrier). | |||||
| 1.1 | 1.5 TR with 5 Star BEE Rating [32.2.3 Page 242] | 10 | No | - | - |
| 1.2 | 2.0 TR with 5 Star BEE Rating [32.2.4 page 242] | 6 | No | - | - |
| 3 | Supply of Microprocessor based air-cooled ceiling Concealed type split Air Conditioner comprising of indoor unit,outdoor unit having both condensing and cooling unit made of Cu tubes having cooling capacity not less than 14000W, ISEER ratio:- 2.7 to 3.4, Noise level not more than 57db with scroll/rotary Compressor suitable for R-410A/R-32 Refrigerant & operation on 415V - 50 Hz - 3 Ph AC supply. (Make - Mitshubishi Heavy Industries/ O-General /Mitsubishi Electric / Daikin/ Hitachi(BOSCH) as per approved by EIC/authority).
(In Old Records Room, Correspondance, FMA section appellate side, G&E section & Dy.Registrar (Administartion) | 15 | Nos. | - | - |
| 4 | Supply of Microprocessor based air-cooled ceiling Concealed type split Air Conditioner comprising of indoor unit,outdoor unit having both condensing and cooling unit made of Cu tubes having cooling capacity not less than 10000W, ISEER ratio:- 3.1 to 3.9, Noise level not more than 55db with scroll/rotary Compressor suitable for R-410A/R-32 Refrigerant & operation on 415V - 50 Hz - 3 Ph AC supply. (Make - Mitshubishi Heavy Industries/ O-General /Mitsubishi Electric/ Daikin/ Hitachi (BOSCH) as per approved by EIC/authority).
(In Punching and appeal section, Decree department, Dy. Registrar Admin's office, Establishment, Cash and Pension main hall Paper book copying and examination) | 18 | Nos. | - | - |
| 5 | Installation, testing & commissioning of the above-said Ceiling Concealed split AC outdoor unit on existing Iron Structure and Indoor unit to be suspended below the celling after fastening the full threaded 8mm dia MS rod in the ceiling incl. all fixing accesories as per requirement of the site & mending good the damages as per direction of E.I.C. | 33 | Nos. | - | - |
| 6 | Supplying, Installation, testing and commissioning including
vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing / brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of 19 mm thick insulation as given below for Suction and Liquid lines, all accessories as per specifications etc. as required :[31.14 Page:-240] | 190 | Mtr | - | - |
| 6.1 | 15.86 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm. [31.14.4 Page:-240] | 762 | Mtr | - | - |
| 6.2 | 6.4 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [31.14.1 Page:-240] | 190 | Mtr | - | - |
| 6.3 | 9.5 mm dia (OD) (Soft drawn) with tube thickness 1.2 mm [31.14.2 Page:-240] | 572 | Mtr | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.63 MB
BOQ_5182038.xls
BOQ • 0.29 MB
WBF-2911.pdf
Tender Documents • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .