Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC | L1 | Accepted-AOC L1 accepted | |
| 2 | L2₹7.3 L+₹1.0 L (16.3%)Rejected-Finance | L2 | Rejected-Finance Other than L1 after deducting Sch of credit for Rs 95175.00 |
Tender Value
Refer Docs
EMD Value
₹16,000
Closing Date
10 May 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE North Akhnoor
GE North Akhnoor C/O 56 APO
REPAIR MAINT OF SUMMER AND COOLING APPLIANCES AND RELATED WORKS AT SUNDERBANI UNDER GE N AKHNOOR
2021_MES_436026_1
GE(N)/AKH- /2021-22
Open Tender
Civil Works
Item Rate
180 days
Sunderbani
Class E cat b i
8 documents required · 8 mandatory
₹500
Yes
GE North Akhnoor
₹16,000
Yes
31 Jul 2021
13 Apr 2021
12 May 2021
13 Apr 2021
10 May 2021
27 Apr 2021
60 days
Amount
Overhauling & servicing of window /Split type AirConditioners up to 2 Ton capacity of any make and carry out of following tasks at different location of different establishment including taking down the AC (if required) from existing location, refixing / commissioning and testing the same after overhauling complete including the following :- (a) Inspection taking down, opening (dismantling) ,washing the condensor and cooling coil complete with acid/water as required and cleaning with air blower and testing complete (b) Checking / examine operation of condensor, blower motor, cooling coil and checking the air circulation to ensure complete movement of working part trouble free (c) Inspection of leakage in system and removal obstruction if any (d) Checking and correction earth continuity of electric items (e) Checking servicing thermostat and over load and other spares and test its functioning (f) Inspecting all electrical connection and remove if any defects (g) Checking servicing and greasing oiling of blower motor.(h) Top up Refrigerent gas if required. Note: Replacement of new parts/worn out parts in lieu of unserviceable/burn out part shall be measured and paid separately as supply only items of sch A.
Supply only the following spare parts for up to1.5/ 2 ton capacity of Tower/cassate/window/ Split type AC any make & model complete.
(i) Air Filter Make and model-as per existing
(ii) Starting relay Make-ANCHO/Epcos/CLASSIC/Whirlpool
(iii) Starting capacitor 120-150 mfd Make- Tesla / Epcos / DVM/Whirlpool
(iv) Starting capacitor 100-120 mfd. Make- Tesla / Epcos //DVM/Whirlpool
(v) Running capacitor 40-60 mfd. Make- Tesla / Epcos/ DVM/Whirlpool
(vi) Running capacitor 30-36 mfd. Make- Tesla / Epcos /DVM/Whirlpool
(vii) Running capacitor 4-6 mfd. Make- Tesla / Epcos/Whirlpool
(viii) Thermostate switch Make-Renutrol or equivilent
(ix) Propeller fan suitable for window/split type AC Make- As per existing
(x) Cooling Coil Make- as per existing
(xi) Condensor coil Make- as per existing
(xii) Outer cover duly painted for Window/split AC
(xiii) MCB SP 20-32 Amps ‘C’ Series ,10KA, 240 volts SP Make : Havells/HPL/Legrand
(xiv) PVC flexible insulated cable multi-strand copper conductor 3 core of size 4 sq mm Make- Kalinga / Plaza / Gloster/Polycab
S & F in replacement of Sheet metal enclosure in/on wall with socket plug top and MCB single pole neutral enclsoure with 2 pin + earth plug and socket complete with one single pole MCB of 32 amps 230 volts of repturing capacity of 10 KA and making good the disturbed surface with existing colour matching complete. Make- Legrand / Havells / Schnider/HPL
Removing the burnt/defective sealed compressor unit of any type and any make from Air Conditioner window type up to 2.0 ton capacity by cutting of suction and discharge lines, unscrewing the foundation nuts & bolts etc, supply and fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with filling of refrigerant gas (in quated rate), welding/brazing work and tightening foundation with nuts & bolts etc all as specified and directed. Note :- (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only.
All as per Srl item No. 4 above but for 1.5 ton Split Air conditioner.
All as per Srl item No. 4 above but for air conditioner split type 2.0 ton capacity.
M&L in replacement of damaged copper tubing of dia 5/8 inch in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L in replacement of damaged copper tubing of dia 3/8 inch in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L in replacement of damaged copper tubing of dia 1/2 inch in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L in replacement of damaged copper tubing of dia 1/4 inch in Split Air conditioners for discharge and suction of gas betweem indoor and outdoor unit complete of sizes as per requirement and specified.
M&L in replacement of damaged insulation for copper tubing of split air conditioners complete all as directed
Repair to Air conditioner window type/Split type up to 2.0 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas (M410a/R134a/R22/R32) as existing and testing etc complete all as specified & directed. Note : (a) Drier capillary and copper tubing are inclusive in quoted rate.(b) Contractor shall be responsible if leakage of refrigerent gas after repair within one year of completing job and done same job without extra payment.
Supply and Fix in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type upto 2.0 ton capacity as per existing model complete all as directed and specified.
Supply and Fix in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type of capacity 1.5 ton/2.0 ton/3.0 ton/4.0 ton as per existing model complete as directed and specified.
Supply and Fix in replacement of Printed Circuit Board as per existing model to repair to split type/window type Air Conditioners of any make and type of any capacity any complete all as directed Make- Voltas/Carrier/toshiba.
Supply and Fix in replacement of wireless remote control unit for split/window type airconditioner as per existing model complete all as directed. Make Carrier (Duracool)/Carrier (X power gold)/LG/VOLTAS
M&L for opening of the automatic voltage stabilizer of capacity upto 8 KVA for repair, detection of fault and its repair, cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts, soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M " all as directed of any make for the following:- Note : (a) Replacement of new parts/worn out parts in lieu of unserviceable/ burn out part shall be measured and paid separately as supply only. (b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM shall be deemed to be included in quoted unit rate.
Supply only the spare parts suitable for automatic voltage stabilizer of any make and capacity complete.
(a) Volt meter (0-300 volts)
(b) Control relay
(c) IC controlled circuit for 5KVA
(d) IC controlled circuit for 8 KVA
(e) Control transformer
(f) Main transformer for 5 KVA
(g) Main transformer for 8 KVA
M&L for Shifting and refixing of split type AC (Indoor and Outdoor units) of any make and any type after servicing and charging of gas (M410a/R134a/R-22/r32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacumming the system as per existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of split AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas,Insulation and LDPE pipe are inclusive in quoted rate.(c) making hole and filling the hole on wall with PCC (1:2:4) type BO (Using 12.5mm graded stone aggregade, 15mm thick rendereing in cement mortar (1:3) good the disturbed surface with existing colour matching are inclusive in quoted rate.
M&L for Shifting and refixing of window AC of any make and any type after servicing and charging of gas (M410a/R134a/R-22/R32) by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system as existing and testing etc complete all as specified & directed. Note :(a) Dismantling and refixing of window AC are including in quoted rate. (b)Drier capillary,copper tubing,refrigernt gas and LDPE pipe are inclusive in quoted rate.(c) Making hole on wall and good the disturbed surface with existing colour matching are inclusive in quoted rate.
Servicing of complete desert cooler comprising oiling, greasing of all rotatry, moveable parts, taking down unserviceable parts for necessary repairs/replacement, assembling of desert cooler with old serviceable parts and replacement of unserviceable parts with new serviceable parts all as directed by Engr-in-Charge. Note :- i) Parts required to be replaced shall be replaced and paid separately as " supply only 'against relevant item (s) of this schedule. However, labour element involved in replacement is included in unit rate quoted against this item. ii) Any minor parts, PVC ellbows, connectors, distributor caps, PVC flexible pipe, wire mesh, rubber pasds/ repairs involved to make the desert cooler completely functional even if not notified by Engr-in-Charge shall be carried out by the contractor without any extra cost to the department.
Supply only the followting items to incorporate against item 21 here-in-before. (a) Grass wool pads (set of three)
(b) Switch piano single pole one way 6 Amps.
(c) Indicator lamp 6 Amps.
(e) Submersible switch for speed controller of motor (three steps).
(f) Front grill for desert cooler Make- Khaitan, Crompton Greaves, Bajaj, Havells/ As per site.
(h) Desert cooler fan motor with fan complete Make- Khaitan, Crompton Greaves, Bajaj, Havells.
Taking down sealed compressor of 165ltr/175 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
Taking down sealed compressor of 286ltr/310/300 ltr capacity of refrigerator of any make and type and replacement of hermetically sealed unit of compressor of same size and type and capacity, connecting sealed unit and discharge pipe with gas welding and soldering rod complete all as specified and as directed.
M&L in repairs thermostat switch for refrigerator of any capacity complete all as specified and directed.
M&L for charging of refrigerator suitable gas after vacuming/pressure and leaking including flushing the system in the refrigerator of any make and 165 ltr capacity
M&L for charging of refrigerator suitable gas after vacuming/pressure and leaking including flushing the system in the refrigerator of any make and 230/286/300/310ltr capacity
Taking down sealed compressor of water cooler any make of capacity 40/80 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccuming and charging the refrigerant gas , testing , commissioning complete all as specified
Taking down sealed compressor of water cooler any make of capacity 60/120 Ltrs and supply and fixing in replacement sealed compressor and connecting up suction and discharge copper pipe with gas welding pressure testing of leakage rectification, vaccuming and charging the refrigerant gas , testing , commissioning complete all as specified
M&L in replacement condensor fan motor 1/35 HP 230 Volt AC single phase suitable for water cooler all as specified and directed.
M&L in replacement condensor fan motor 1/83 HP 230 Volt AC single phase suitable for water cooler all as specified and directed.
Detecting the gas leakage , rectifying the defects, vacumising and charging fresh refrigerant gas and commissioning and testing the water cooler 40/80 and 60/120 ltrs complete all as specified and as directed.
M&L for preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 40/80 ltrs capacity all as specified and directed.
M&L for preparation of old painted steel surface of water cooler by complete scraping and applying one coat of synthetic enamel paint by spraying on outer surface as per existing colour and black on bottom portion such as compressor, bottom frame etc of 60/120 ltrs capacity all as specified and directed.
Submain wiring with two single core (FLRS) PVC insulated flexible copper conductor cable of size 6 Sqmm (multistranded) drawn into and including PVC conduit, 2 mm thickness with fitting and accessories fixed on walls/ceiings including cutting chasses in brick walls and making good the chased walls with CM 1:3 and finishing the surfaces to match with existing surfaces including 4.0 Sqmm PVC insulated copper conductor cable as earth wire drawn into conduit and connecting to common earth or earth dolly, including fixing hooks, clamps etc, including taking down unserviceable materials from site for carring to store all as directed by Engr-in-Charge. (Note : Two runs of copper cable, one run of earth wire, one run of PVC conduit shall be measured as one unit.) Make Havells, polycab , Gloster
Submain wiring with two single core (FLRS) PVC insulated flexible copper conductor cable of size 10 Sqmm (multistranded) drawn into and including PVC conduit, 2 mm thickness with fitting and accessories fixed on walls/ceiings including cutting chasses in brick walls and making good the chased walls with CM 1:3 and finishing the surfaces to match with existing surfaces including 6.0 Sqmm PVC insulated copper conductor cable as earth wire drawn into conduit and connecting to common earth or earth dolly, including fixing hooks, clamps etc, including taking down unserviceable materials from site for carring to store all as directed by Engr-in-Charge. (Note : Two runs of copper cable, one run of earth wire, one run of PVC conduit shall be measured as one unit.)Make Havells, polycab , Gloster
Preparation of old painted surfaces of desert cooler body complete and spray painting with one coat of red oxide from inside and one coat of synthetic enameal paint as approved by Engr-in-Charge and writing MES No as directed on Desert Cooler Body.
M&L for casing capping ISI marked 40mm size all as specified and directed Make Anchor
M&L for casing capping ISI marked 25mm size all as specified and directed Make Anchor
Taking down unsv Panel and accessories like burnt MCCB, bus bars and Supply, Installation, commissioning and testing LT panel outdoor cubical floor mounted channel type of size not less than (L=2 m x b=0.4mxh=1.2m) openable to front and back both side made out of 2 mm thick CRCA sheet duly powder coated complete with bus bar size not less than 40x5mm rating made of Aluminium strip duly drillled holes for connections and mounted on epoxy based post insulators for 3 phase 4 wire 415 volts 50Hz power supply system suitable for and including the following. Make of panel Legrand, ABB , L&T Note:- Panel shall be as per IEC -61439 part I & II and TTA approved
(A) INCOMER
i) MCCB DU 250 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 KA. -01 Nos as incomer Make L&T Cat part No CM90634OOPO Conforms to IS/IEC 60947-2 & IEC 60947-2 l Adjustable Overload Setting: 0.8 - 1.0 x In
(B) OUTGOING
(ii) MCCB DU 200 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25KA. -02 Nos as outgoing Make L&T Cat part No CM90634OONO Conforms to IS/IEC 60947-2 & IEC 60947-2 l Adjustable Overload Setting: 0.8 - 1.0 x In
iii) MCCB DU 125 Amp 4 Pole 50 Hz 415 V with rupturing capacity 25 KA. -02 Nos as outgoing Make L&T Cat part No CM90634OOMO Conforms to IS/IEC 60947-2 & IEC 60947-2 l Adjustable Overload Setting: 0.8 - 1.0 x In
(iv) On load changeover 200 Amp 4 pole Make L&T -01 No
iv) Indicator set RYB 01 set of 3 pcs,
All accessories prewired with suitable size copper conductor cable/strip and suitable foundation as per manufactrur's recomendation.
Note:-(i) Drawing of the panel will be approved by the Engr-in-charge (ii) Factory testing will be carried by the manufactrer in the presence of Engr-in-charge, Any changes in the design will be incorporated.
M/s Mool Raj Romesh Chander
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .