Assistant Engineer,PWD ,HESD-I
Sarat Sarani Kodalia Hooghly 712123
SITC of AC machine in guest room of District Judges Bungalow in Chinsurah, Hooghly
2026_WBPWD_5018501_1
WBPWD/AE/HESD-I/ NIeT-02 of 2026-27
Open Tender
Air-Conditioner
Item Rate
15 days
Hooghly
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,415
O/O the A.E,HESD-I,PWD,
28 Aug 2026
12 Aug 2026
31 Aug 2026
12 Aug 2026
28 Aug 2026
12 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, Installation, Testing, and Commissioning of air-cooled Hi-Wall split type air conditioners of following capacities comprising Indoor and Outdoor Units with factory-charged Rotary/Scroll compressors (R-32/R-410A) including surface/concealed copper refrigerant piping insulated with closed-cell elastomeric nitrile rubber insulation and wrapping tape (up to 3 m), FRLS type copper power cable (up to 3.5 m) with suitable plug top, 3 meters of drain pipe, and wireless remote control with suitable battery. The system shall operate on 230V, 50Hz (±tolerance as per applicable standard), single-phase AC supply, providing cooling, dehumidification, and air circulation functions conforming to IS-1391 (Part-II ) with all amendments, and shall be capable of efficient performance at outdoor ambient temperatures up to 50°C, with a minimum 5-year OEM warranty on both the compressor and PCB. The system shall be installed with S&F appropriate fixing arrangements as per OEM recommendations, including wall openings, mending well the damages and making necessary connections including T&P & labour etc as required complete in all respect as per the direction of EIC. [Non Schedule Item No. AC MACHINE/ Item No. 2]
Cooling Capacity- 6.1 kW (Minimum) , Air Flow Rate : 800 CFM (Minimum), Minimum ISEER - 5.0, BEE level - 4-Star(min) (Make--Daikin/Hitachi/Carrier/Blue star/Voltas) [Non Schedule Item No. AC MACHINE/ Item No. 2.3] | - | Each | 1.25 | - |
| 1.1 | Supply & Laying Extra Add-on items- 5/8" (for gas line) & 1/4" (for liquid line) copper refrigerant pipe with 9 mm. thick nitrile rubber insulation, 4 core x 2.5 sq.mm. copper cable incl. fixing arrangement and wrapping insulation of aerotape complete in all respect for 1.5 / 2 /2.5 TR A.C. Machine. as per direction of E.I.C [NS] | - | Mtr | 100 | - |
| 2Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. [Non Schedule Item No. AC MACHINE/ Item No. 5] | |||||
| 2.1 | Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required
2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC [E-14/1(a) (iii)] | - | RM | 100 | - |
| 2.2 | Finishing of the PVC insulated wire ends by socketting with pin / ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm [F-5/9(i)] | - | set | - | - |
| 3 | 4 sq. mm. [F-5/9(ii)] | - | set | 100 | - |
| 4S & F 240V ,16A,3 pin Modular type plug socket 2 module (Legrand, Myrius cat. no. -673145/Crabtree) without switch & plug top on 2Module GI Modular type switch board with top cover plate fixed in wall including S&F switch board and cover plate and making necy. connections with PVC Cu wire and earthing continuity wire etc. [E-18/9(b)] | |||||
| 4.1 | Supply & Fixing 240 V, 25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [5(b)/E-17] | - | nos | 100 | - |
| 4.2 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (C Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu. wire and earth continuity wire etc. [E-19/17] | - | nos | - | - |
| 31TERMS AND CONDITION 1. THE AGENCY MUST PROCURE THE MATERIALS FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES. SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT OF THE MANUFACTURER / OEM BECOMES APPLICABLE TO THE PRODUCTS TO BE DELIVERED AND INSTALLED BY THEM. 2. DOCUMENTS THAT AUTHENTICATES SUCH PROCUREMENT FROM THE MANUFACTURER/OEM OR FROM THEIR AUTHORIZES SALES CHANNEL SO THAT THE STANDARD WARRANTY / SOPPORT SHOULD BE SENT FROM THE e-MALE OF THE MANUFACTURER/OEM / AUTHORIZES SALES CHANNEL TO THE e-MALE OF ENGINEER-IN-CHARGE AND HARD COPY OF IT TO BE SUBMITTED DURING EXECUTION OF WORK/ SUBMISSION OF BILL. 3. IF ANY REFURBISHED MATERIAL IS SIPPLIED ABD INSTALLED, PENAL ACTION WILL BE TAKEN AS PER EXISTING RULES. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.48 MB
Tendernotice_2.pdf
PDF • 0.51 MB
BOQ_5089568.xls
BOQ • 0.35 MB
item_corrigendum02.PDF
PDF • 0.12 MB
Timeextend02.pdf
PDF • 0.93 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].