Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 CrAccepted-AOC EBENEZER C C33 1185A CHALIKAVATTOM VENNALA P O KOCHI KERALA 682 028 | ERNAKULAM | KERALA | 682028 | ₹1.3 Cr | L1 | Accepted-AOC Accepted |
| 2 | L2₹1.3 Cr+₹83,220.05 (0.64%)Rejected-AOC | ₹1.3 Cr+₹83,220.05 (0.64%) | L2 | Rejected-AOC Rejected |
| 3 | L4₹1.3 Cr+₹3.7 L (2.88%)Rejected-AOC | ₹1.3 Cr+₹3.7 L (2.88%) | L4 | Rejected-AOC Rejected |
| 4 | L5₹1.4 Cr+₹13.8 L (10.6%)Rejected-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹1.4 Cr+₹13.8 L (10.6%) | L5 | Rejected-AOC Rejected |
| 5 | L6₹1.5 Cr+₹23.3 L (17.9%)Rejected-AOC THOTTAPPALLY HOUSE EMILY KALPETTA P O KERALA 673121 | WAYANAD | KERALA | 673121 | ₹1.5 Cr+₹23.3 L (17.9%) | L6 | Rejected-AOC Rejected |
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
13 May 2024, 6:00 pmClosed
CWE (NW) KOCHI
CWE (NW) KOCHI
SPECIAL REPAIRS TO WEST WING OF 340 MEN BLOCK (BLDG NO. P-166) AT NB (K)
2024_MES_649654_1
CWE(NW)KOCHI/81438
Open Tender
Civil Works
Item Rate
270 days
KOCHI
AS PER NIT
7 documents required · 7 mandatory
₹1,000
GE (NW) KOCHI
₹2.2 L
Yes
6 Sept 2024
8 Apr 2024
15 May 2024
8 Apr 2024
13 May 2024
29 Apr 2024
Amount
Taking down chowkhats or frames with shutters (without taking off shutter from the frame) of size n.exc 1.50 Sqm and removing from site complete all as specified and directed.
Same as item No.1 above but exc 1.50 Sqm and n.exc 4.00 Sqm each.
S&F IInd class hardwood plain solid straight chowkhat and frame wrought framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed.
S&F MS work as in hold fast and similar small articles conforming to Fe-290, Gde E-165 complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (Using 20mm graded stone aggregate) as in cills, copings, bed blocks for hold fasts and the like complete all as specified and directed.
S & F 35mm thick IInd Class hard wood rail and stail Plain framed, factory made panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply. The size of rail and stile as per IS : 1003(Part I), kiln seasoned and chemically pressure treated as completed as specified.
M&L 30mm thick IInd class hardwood glazed and skeleton shutters , open rebated and prepared to receive glass gauge etc, edges of framing plain chamfered or rounded, fitted with cut and mitered beads for securing glass etc, size of members of shutter as specified in SSR (Part-I)- 2009 complete all as specified and directed.
S & F Collapsible steel gates, top hung, consisting of channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and directed.
S&F mild steel framed work as in door,chowkat,grills, gratings etc with ends of bars shouldered and riveted or forged into spikes, framed guard bars, barred iron doors etc, conforming to Fe-290, Gde-E-165 all as specified and directed.
S&F Solid PVC door frame of size 50mm x 47mm made out of 5mm ivory colour PVC sheet reinforced with M.S. square tube, S&F in opening as per specification and drawing complete all as specified and directed.
S&F factory made Solid PVC Moulded Door Shutters 28 to 30 mm thick (stile) with wood free EPS, with 2,4 or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front Face & 2mm Plain colour PVC sheet on back face, S&F in frame at site as per specification & drawing all as specified.
S&F powder coated aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed.
S&F powder coated aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm each pane complete all as specified and directed.
S & F Stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
S & F 100 mm long stainless steel butt hinges complete all as specified and directed.
S&F aluminum anodized barrel tower bolt 200mm long of extruded section complete all as specified and directed.
S&F aluminum anodized sliding door bolt 300mm long with hasp and staples (bolt type) and fixing clips of sheet cast of extruded section and fixing bolts and sliding bolts of extruded section complete all as specified and directed.
S&F aluminum bow handle "D" type anodized 150mm long complete all as specified and directed.
S&F in repair MS helical door spring 300mm long including roller and roller plate complete all as specified and directed.
S & F 4mm thick white colour aluminium composite panel complete all as specified and directed.
S& F 20mm dia stainless steel curtain rod complete all as specified and directed.
S & F 20 mm dia Stainless steel curtain rod bracket with knobs complete all as specified.
Taking down of existing roof treatment consisting of screed bed tar felts etc and removal of dismantled materials complete all as specified and directed by Engr in Charge.
M&L for Cement concrete type B- 1, 1:2:4 (20mm graded aggregate) for coping or chamfered on edges and. levelling course of concrete in roof slab all as specified and as directed.
M&L for providing and applying pitch free polyethene water proof coating using Fosroc Nitoproof 600 PF or equivalent in given in list of make complete in following steps:- (a) RCC surface shall be made dry, clean, even and checked for soundness. Removal all oil, dirt, laintance and other contaminants manually and surface shall be made fairly smooth finish. (b) Injection grouting of construction joints and honey combs if any shall be done by cementtious pressure grouting with 40 psi pump using Cebex 100 or equiavlent make from approved list of manufactures @ 225 gms mixed to 50 kg bag of cement including joints packing using polymer modified mortar. (c) Apply pitch free polyurethane water proof coatiing using Fosroc Nitoproof 600 PF or equivalent make from the approved manufacture list, over dry surface at 1.5 mm thick in 2 coats at an interval of 6 hours over a substrate @ 2kg/sqm using spray/ squeegee/ roller/ brush. The second coat should be applied in perpendicular direction to the first coat. (d) Laying 200gsm non woven geo textile membrane over Nitoproof 600 PF coating with overlap sealed before providing screed all as per manufactures instruction. (e) Plastering in CM 1:3, 25mm average thickness (maintaining required slope) Note:- (i) The work shall be executed through specialized agency/ authorised applicator of approved manufacturer and name of manufacturer shall be got approved before commencement of water proofing work. (ii) Waterproofing coating shall have the elongation of 500-700% (ASTMD412-90, tear resistance of >21 KN/m (ASTM D 624-00), and tensile strength of >1.9 N/mm2 (ASTM D412-90) and it should have a solid content of 80-85%.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed by Engr-in-Charge.
M&L RCC (1:2:4) type B-1 (Using 20mm graded crushed stone aggregate) as in slabs, shelves supported on walls, beams and columns in floor or roof including balconies, canopies, deck slabs or in Chajja/facia projection and the like complete all as specified and directed by Engr-in-Charge.
M & L RCC Nominal mix type B1, 1:2:4 (20mm graded aggregate) as in chajja complete all as specified and directed.
M&L mild steel CRS bars 10mm dia and over, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed by Engr-in-Charge.
Same as item No.31 but 6mm to 8mm dia complete all as specified and directed.
Formwork to chullah hoods, chajjas, troughs & similar items including edges,rough finished flat surface.
M&L for use and waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick for fair finished flat surfaces (Horizontal or sloping) complete all as specified and directed.
Demolition of brick work or stone masonry built in cement mortar including all quoins, arches, jambs etc complete all as specified and directed.
M&L for precast cement concrete block masonry in type C1, 1:3:6 (20 mm graded aggregate) with solid blocks exc 10 cm in width and setting in cement mortar 1:6 in foundation load bearing wall and wall complete all as specified and directed.
Taking down cement plaster of any description on brick work or stone masonry walls including rackingout joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge.
M&L 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces, finished even and fair without using extra cement complete all as specified and directed by Engr-in-Charge.
M&l for rendering 8mm thick in CM 1:4 using liquid WPC over 12mm thick rendering in CM 1:6 on fair faces of brick work or concrete surfaces finished even & smooth without using extra cement complete all as directed. Note: Supply only water proofing compound shall be paid separately.
M&L for 10mm thick plaster on fair faces of roof, chajja and roof parapet of CM (1:3) finished even and smooth without using extra cement etc complete all as specified and directed.
M&L 5mm thick rendering in ceiling of cement mortar (1:3) on fair faces of brick work or concrete surfaces, finished the surfaces even and smooth without using extra cement complete all as specified and directed.
Supply only liquid water proofing compound complete all as specified and directed by Engr-in-Charge.
Demolition of cement concrete (Un-reinforced) in ground floors and pavings n.exc 15cm thick (above or below GL) complete all as specified and directed by Engr-in-Charge.
M&L 75mm thick PCC (1:3:6) type C-2 (Using 20mm graded crushed stone aggregate) as in plinth protection /hardstanding , laid in panels, finished the top surfaces even and fair without using extra cement complete all as specified and directed.
Dismaintaing wall/floor tiling/ terrazo tile/ mosaic tiles/ pcc tiles incl. cement mortar bedding removing serviceable tiles to store and rubbish off the premises complete all as specified and directed..
M&L for Non-skid ceramic coloured tiles 7-8mm thick (square/rectangular), area of each tile not exc 0.18 Sqm but not exceeding 0.38 sqm, over and including 10mm thick screed bed in CM (1:4) in flooring, set and jointed in neat cement slurry and pointed in epoxy joint filling minimum 5mm depth and 2mm thick spacer width complete all as specified and directed by Engr-in-Charge. Note: Epoxy joint filling shall be measured and paid speperately
M&L for Glazed ceramic coloured joint free tiles 450x300X7mm/600x300x7mm in vertical surfaces over and including 10mm thick rendering in Cement mortar (1:3), set and jointed in neat cement slurry and pointed in coloured cement to match complete all as specified and directed by Engr-in-Charge
M&L for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 15mm thick screed bed of CM 1:6 all as specified and directed.
M&L for joint free coloured Non Skid ceramic tiles 7 to 8mm thick (square/ rectangular) area of each tile exceeding 0.18 but not exceeding 0.38 sqm, in vertical surface etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match, over 10mm thick rendering of CM 1:3 all as specified and directed.
M&L for Machine cut Kota stone slab 18-20mm thick as in floor/ treads of steps (single piece with anti-slip groves (3 Nos in each tread) laid over and including 15mm thick screed in CM 1:4, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing complete all as specified and directed by Engr-in-Charge.
M&L for machine cut Kota stone slab 18-20 mm thick (single piece) as in risers to steps, skiting/dado, pillars, window cills and the like, laid over and including 10mm thick rendering in cement mortar 1:3, set & jointed with grey cement slurry and pointed in white cement mixed with pigment to match the shade of the slab including cutting, rubbing and polishing complete all as specified and directed by Engr-in-Charge.
M & L for epoxy tile joint filling for floor and walls. All complete as per the manufactures instructions complete all as specified and directed.
Mirror polishing on marble/ granite/Kota stone/ stone work where ever required to give high gloss finish complete all as specified and directed.
M&L for 18-20mm thick granite (of any type) work (table rubbed and polished) stone slab as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust to match with marble shade over and including cement screed bed 15mm thick in CM (1:6) complete all as specified and directed by Engr-in-Charge.
M&L for 25mm thick PCC (1:2:4) type B-0 (using 12.50mm graded crushed stone aggregate) as in sub base of floor for levelling of floor as required portion complete all as specified and directed by Engr-in-Charge.
M&L for three coats of white wash to newly plastered surfaces of ceiling including preparation of surfaces, complete all as specified and directed by Engr-in-Charge.
M&L for two coats of oil bound distemper over a coat of 1.5mm thick wall care putty and one coat of alkali resistant primer to newly plastered surface including preparation of surfaces complete all as specified and directed by Engr-in-Charge.
M&L for preparation new plastered External surfaces for preparation of surface and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed
M&L for preparation of old ceiling surface and One coat of white wash on ceiling complete all as specified and directed.
Complete removal of existing surface finishes of external wall, preparation of surface and Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L for preparation and complete removal of existing treatment and applying two coats of Oil bound distemper over a coat of 1.5 mm thick wall care putty and one coat of alkali resistant primer complete all as specified and directed. Note:- Application of paint, primer and wall care putty shall be as per manufacturer's instruction.
M&L for preparation of new surfaces of wood and wood based materials of any descriptions not otherwise described over 10Cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation and apply two coat of synthetic enamel paint over a coat of red oxide primer on new steel surfaces complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor or fixed to wall including necessary clamps complete all as specified and directed.
S&F PVC (SWR) bend any radius 110mm bore complete all as specified and directed.
S&F in repair PVC flushing cistern low level 8 to 10 Ltr capacity of approved make including fixing of brackets connection to WC with CI brackets and making good disturbed area complete all as specified and directed.
S&F in repair vitreous china WHB white with flat back of size 550x400mm with bracket including waste coupling and 32mm PVC waste pipe complete all as specified and directed.
S&F in repair vitreous china wash down water closet pan pedestal pattern white including fixing with trap including PVC matching seat cover complete all as specified and directed.
S&F in repair brass CP towel Rail 600mm long "D" type complete all as specified and directed.
S&F in repair Stainless steel soap dish fixed to wall with screw complete all as specified and directed.
S&F in repairSheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long incl aluminium alloy bracket and guard rail complete all as specified and directed.
S & F in repair Vitreous China urinals, half stall type complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; with PTMT Urinal spreader, grating and Union for discharge pipe complete all as specified and directed.
Demolition of cement concrete (unreinforced) above ground floors and paving exc. 15cm thickness complete all as specified and directed.
M & L for plain cement concrete Nominal mix (1:5:10) type E2(using 40 mm graded brick aggregate) as in sunken floor complete all as specified and directed.
M&L 50mm thick PCC (1:2:4) type B1 (Using 20mm graded stone aggregate) for sub base of sunken portion complete all as specified
M & L 10mm thick rendering in CM ( 1 : 3 ) mixed with water proofing compound on fair faces of brick walls or conc surfaces and finished even & fair complete all as specified.(Note : Supply only water proofing compound paid separately)
S & F 0.56mm Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed complete all as specified and directed. )
M&L for preparing old painted steel and Iron surfaces of any description over 10 cm Width /Girth and applying one coats of synthetic enamel paint of any tint complete all as specified and directed.
Destruction of growth of weed plants with roots from on the roof of bldgs and on the wall of bldgs (any height) with 2.40 oil mixed veedicides or mixed with veedol chemical solution and sprayed on and around roots and at places of possible growth of weeds and making good damaged surfaces by plastering, pointing etc complete all as specified and as directed by Engr-in-charge.
M&L Forming Contruction (Dummy) joints 65mm deep x 10mm wide,filled with sealing compound grade A complete all as specified and directed.
Dismantling plain or corrugated steel sheeting any gauge, thickness complete in roofing complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description complete all as specified
S&F for pre-painted galvalume zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified.
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St-240 complete all as specified and directed.
Cutting openings, through brick walls (in cement mortar) for door, window and other openings or enlarging existing openings converting window into door openings, etc. or cutting out defective brick work for under-pinning, including providing, fixing and removing shoring, cleaning and stacking bricks,removing surplus serviceable bricks, hard-core, etc.. to store and rubbish not exc. 50m
M & L 4mm thick galvansied steel wire as in drying line for cloth complete all as specifed
M & L 10mm dia and 150mm length Mild steel hanger bolt for fixing of galvanised steel wire complete all as specified
Providing and injecting anti-termite chemical emulsion for Post Constructional Antitermite Treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron complete all as specified and dircted by Engr-in-Charge
M & L for Anti termite post construction Treatment of soil under existing floors using anti- termite emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified
M & L for Anti termite post construction treatment at points of contact of wood work by Anti-termite chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same complete all as specified
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc) or insulation boards/blankets, any thickness including cover fillets complete all as specified and directed.
M& L 20mm thick bitumen expansion joint filler board for building construction joint filling complete all as specified.
Supply and fix 15mm bore Pillar taps,cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
M&L for Hardcore of broken stone of gauge n.exc 63mm deposited spread and levelled in layers n.exc 15cm thick watered and rammed to a true surface all as specified
M&L 75mm thick PCC 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base of floor complete all as specified and directed.
M & L for chequered colour cement concrete tiles 30x30cmx 25mm thick set jointed grey and pigment and pointed in neat cement slurry in floors/steps including screed bed or bedding layer of morter 15mm thick in cm 1:4 complete all as specified and directed
Excavation in trenches n.exc 1.5m and n.exc 1.5m in depth for foundation and getting out in soft/ loose soil complete all as specified and directed.
Excavation over areas, n exc 1.5m deep and getting out soft/loose soil complete all as specified and directed.
Excavation over areas, exc 1.5m deep and getting out in hard dense soil complete all as specified and directed.
Removing excavated soil exc.250m but n.exc 500m and depositing where directed by Engr-in -charge.
Returning filling in soft/loose soil including spreading leveling watering and wall ramming in layers n.exc 25 cm thick all as spd and directed
M & L for Cement concrete in surface channels and drains in PCC 1:2:4 type B2 (40mm graded aggregate) complete all as specified and directed
M&L Cement concrete in foundations, filling and mass concrete type C2 1:3:6 ( 40mm graded aggregate)
M&L for cement concrete type C1 1:2:4 using 20 mm graded aggregate as in coping including use waste of formwork etc complete all as specified and directed
M&L 15 mm thick plaster on fair faces of brick or concrete surfaces in cement and sand mortar 1:4 finished even and smooth without using extra cement.
M & L for precast cement concrete type B1, 1:2:4 (20mm graded stone aggrigate) in landings, cover slabs (for man holes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces set in cement mortar 1:4 complete all as specified
M&L for RCC (Nominal mix) 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilaster and buttresses complete all as specified and directed.
M & L for Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical for flat fair finished surface complete all as specified and directed.
M&L brick work with sub class "B" old size bricks, in one brick thick honey comb walling built in Cement mortar (1:4) complete all as specified and directed
S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floor complete all as specified and directed by Engr-in-Charge.
M&L cement concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in PCC 1:3:6 type C2 with 40mm graded aggregate, dia of pipe 110mm complete all as specified and directed
S&F 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches/floorcomplete all as specified and directed
S&F 110mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints, fixed to wall complete all as specified and directed.
S&F 75mm dia PVC (SWR) pipe single socketed, in any length with rubber ring joints,fixed to wall complete all as specified and directed.
S & F Stack clamps for 75mm dia PVC pipe out of 50 mm by 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S & F Stack clamps for 110mm dia PVC pipe out of 50 mm, 5 mm flat iron and 16mm dia round iron stays, including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
S&F PVC (SWR) bend any radius 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
Taking down carefully existig copper / aluminium point wiring for light / fan / bell / socket 5/15 Amp points complete with fitting and fixtures such as switches, sockets, c/ rosess, holders and bracket fittings with battens / conduits / wires,T/L fittings and making good the disturbed surfaces of walls and roofs etc.and to match with existing colour complete all as specified and directed.
Taking down carefully unserviceable main switches and distribution boards with fuses/ MCB's (single phase or three phase) of any capacity complete all as specified and directed.
Taking down carefully old unserviceable sub main wiring and making good disturbed surfaces and matching with existing complete all as specified and directed.
S&F point wiring with 1.5 Sqmm PVC insulated unsheathed FRLSH multistranded single core copper conductor cable in PVC concealed conduit rigid non metalic (ISI marked) fixed concealed on wall/ roof except beam, column and RCC roof including chases cutting incl suitable size/ module of sunken box for modular switch and socket and modular white cover plate, flush metal box etc inxl 1.5 Sqmm PVC insulated copper conductor as earth continuity wire for One light point controlled by one switch and making good disturbed surfaces of walls, floors etc complete all as specified and directed.
Same as per Item No. 124 above but one 3 pin 5 Amp socket outlet point controlled by one switch on Independent board complete all as specified and directed by Engineer-in-Charge.
Same as per Item No. 124 above but one 3 pin 5 Amp socket outlet point controlled by one switch on same board complete all as specified and directed by Engineer-in-Charge.
Same as per Item No. 124 here-in-before but one 15 Amps socket outlet point controlled by one single pole switch one way and wiring with 2.5 Sqmm PVC insulated, stranded, unsheated copper conductor on independednt board with continuous earth wire of size 2.5 Sqmm green colours PVC insulated, unsheathed, stranded copper conductor cable complete all as specified and directed.
M&L Switch modular type 6 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
M&L Switch modular type 16 amps, 1 module single pole one way duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 6A - 2 in 1,without shutter, 2 module, duly ISI marked, complete all as specified and directed.
S&F Socket outlet modular type 16A, 3 pin combined, 2 module, duly ISI marked, complete all as specified and directed.
S&F Ceiling rose surface type, 240 volts, 50 Hz, 6A, Pilot 3 plate, white in colour, bakelite 65 x 50mm, 3 terminals duly ISI marked complete all as specified and directed.
S&F batten holder (with metal ring), 240 volts, 50 Hz, 6A, white in colour, duly ISI marked complete all as specified and directed by Engineer-in-Charge.
S&F modular fan step type electronic fan regulator for ceiling fan 1200/1400mm size, 240 volts, 6 Amps, 2 module, 120W, white in colour, duly ISI marked complete all as specified and directed.
Supply and fixing LED light fitting 1 x 20 Watt, 120 Lumen/ Watt, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S&F LED bulb of 9 watt, 110 Lumen/Watt, B22, 6500K complete all as specified and directed by Engineer-in-Charge. Make- KCSAD, Cat Part No.KDB09 or any other equivalent make in the approved manufactures list.
Supply and fixing LED street light fitting 35 Watt, 120 Lumen/ Watt, 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/ 66 protection complete all as specified and directed.
S&F Factory made three phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 6 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming MCCB and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail suitable for use on 240/415V, 50Hz supply, VTPN DB, IP-43 protection, partly immersed in wall, without MCCB and MCB's including making good distrubbed surfaces with matching colour, complete all as specified and directed by Engineer-in-Charge. Make- Indoasian, Model No- Optium F1+18, Cat Part No. 811889 or any other equivalent make in the approved manufactures list.
S&F MCCB thermal based release adjustable type 4 pole 125 Amps 50 Hz 415 Volts with rupturing capacity 16 KA including testing, complete all as specified and directed.
S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 12 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F Factory made single phase and neutral Sheet Steel made out of CRCA 1.2 mm thick, powder coated double door vertical distribution board 8 way, dust and vermin proof, fitted with two cover, one screwed cover for incoming and outgoing MCBs and the second for protection of MCBs fitted with colour bus bar of capacity 200 Amps, neutral link, earth bar and din rail. suitable for use on 240V, 50Hz supply, partly immersed in wall and making good distrubbed surfaces with matching colour, complete all as specified and directed.
S&F MCB SPN, 40A - 63Amps, 240 volts, "B" series, 10KA duly ISI marked, in MCB DB, complete with connection testing and commissioning complete all as specified and directed.
S&F MCB SP, 6A-32 Amps, 240 volts, "B" series, 10KA duly ISI marked, in the MCB DB, complete with connection testing and commissioning complete all as specified and directed.
M&L for Sub main wiring with two single core 25 Sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 16 Sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length)
M&L for Sub main wiring with two single core 16 Sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 10 Sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length)
M&L for Sub main wiring with two single core 10 Sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 10 Sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length)
M&L for Sub main wiring with two single core 6 sqmm FRLS insulated and unsheathed stranded copper conductor alongwith earth wire 6.0 sqmm drawn in FRLS rigid conduit connected to main board complete all as specified and directed (Two runs cable and one number earth wire and suitable FRLS conduit shall measured together as unit length)
S&F exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, single phase, Copper winding of sweep 300MM including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
S&F exhaust fan heavy duty with louvers complete of sweep size 300mm, single phase, with bolts, nuts and washers, size of the bolt 15 cm long 12mm dia embedded in the wall including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed.
S&F ceiling fans, complete with blades, down rods, accessories 230V, 1200mm sweep, with min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current (BLDC) including provision of PVC flexible copper cable of size 23/00.0076 three core from ceiling rose to exhaust fan max 1.5 mtr for giving connection complete all as specified and directed by Engineer-in-Charge. Note : Old Ceiling fans to be deposite at AGE E/M (NW) store yard.
Earthing complete with galvanized steel plate elecrode of size 60 cm x 60cm x 6.0 mm thick burried directly in ground vertically to a depth not less than 2.5 mtr below the ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level. Earth plate surrounded by 15mm thick packed alternative layers of charcoal dust and comman salt, earth lead GI wire of 4mm dia (8 SWG) by means of bolts, nuts, check nuts and washers of galvanised iron with thimbles. The other end of GI earth wire is connected to main switch board and protected by light grade GI pipe of 15 mm bore. Provision of 20mm bore light grade GI pipe for watering including GI funnel and wire mesh. Pipe shall be provided vertically upto top level of earth pit and then taken horrizontally to the earth pit. Cement concrete chamber of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate.The chamber shall be constructed one metre away from edge of earth pit. 50 mm thick pre cast cover of cement conrete (1:2:4) type B-1 using 20 mm graded stone aggregate and MS angle iron 50 x 50 x 6 mm frame including two coats of painting over a red oxide to exposed steel surfaces. Excavation in soft/ loose soil, returning filling and removal of surplus soil to a distance of 50 mm as directed and shown in Electrical Plate No- 3 of SSR Part-1 (2009) complete all as specified and directed by Engineer-in-Charge.
S&F XLPE insulated, armoured, 1100 volts grade, heavy duty cable of size 70 Sqmm nominal cross section, 3.5 core, aluminium conductor, served with inner sheathing of galvanized steel wire or tape and over-all PVC sheathed in service connections, laid in trenches, duct, through pipe, in floor, on pole including jointing with double compression copper stain less steel gland at DBs and testing, complete all as specified and directed.
M&L Dry and clean riddle sand for cable cushioning to underground cable protection, complete all as specified and directed. Note- Punned down thickness shall be measured.
S&F Cover to underground cable with one layer of bricks using sub class ‘B’ bricks (old size) laid flat across the cable complete all as specified and directed.
Removal of surplus soil to a distance not exc. 50 metre and depositing where directed at a level not exc. 1.5 metre above the starting point complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of cable, fixed to poles/walls, laid under floor/road crossings, complete with and including clamps socket & elbow etc complete all as specified and directed.
Supply & fixing air termination vertical type Single pointed aluminium rod made of 12 mm dia and 300 mm long with base plate welded at bottom complete all as specified and directed.
Supply & fixing aluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
Supply & fixing GI strip 32x6mm buried directly in ground or fixed to walls complete all as specified and directed.
Supply and fixing test point terminal block made of gun metal or phosphorus bronze of size 75mm x 75mm x 25mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw for fixing the same on wall, including suitable size of coverd MS box of 1.5mm thick complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm thick, buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers all around top and bottom and electrode connection by using galvanised iron earth lead strip of size 32 x 6mm flat iron by means of bolts, nuts, check nut and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe 40mm bore protection pipe light grade for protection strip upto 3m above ground level (Up to the test points) PCC chambeer in cement concrete (1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:- (a) The unit rate shall include for protection pipe, GI water pipe, funnel, wire mesh excavation, RCC pit cover, test point, 32x6mm galvanised strip from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m, no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction, elbow etc. shall be deemed to be included in the unit rate. (c) If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account. (d) Earthing work will be carried out in presence of MES representative complete all as specified and directed by Engineer-in-Charge.
Supply and fixing 40mm dia GI pipe medium grade with all fittings fixed to walls and ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Rotational moulded polyethylene three layered structure PVC water storage tanks (cylinderical vertical with closed top) hoisted & fixed in position of capacity 2000 liters incl taking out u/s old one complete all as specified and directed.
S&F in replacement on wall/ concealed on wall high pressure CPVC pipes SDR-13.5 & plain CPVC SDR 11 fittings including all necessay fittings, solvents of size 25 mm dia including taking down old one complete all as specified and directed.
All as per item No. 163 here-in-before but of size 20 mm dia complete all as specified and directed.
S&F in replacement CPVC Ball Valve of size 25 mm dia suitable for CPVC pipe incl necessary fittings and taking down old one complete all as specified and directed.
S&F in replacement CPVC Ball Valve of size 20 mm dia suitable for CPVC pipe incl necessary fittings and taking down old one complete all as specified and directed.
S&F in replacement of bib tap Chromium plated (CP), half turn with flange and areator, fancy type long body cast copper alloy with crutch or butterfly handle screwed for GI/ CPVC pipe of size 15mm and taking down old, complete all as specified and as directed. Make- Cera Cat Part No. F2008152 or any other equivalent make in the approved manufactures list.
S&F in replacement concealed stop cock regular body, half turn with flange chromium plated CP cup fancy type of size 20mm and taking down old one, complete all as specified and as directed. Make- Cera Model No. F1015361 & F4050101 or any other equivalent make in the approved manufactures list.
S&F 15mm angle valve, half turn with flange, with flange type chromium plated for fixing with CPVC pipe and taking down old one, complete specified and as directed. Make- Cera Model No. F2008201 or any other equivalent make in the approved manufactures list.
S&F in replacement of swivel overhead shower (minimum weight 40grams) of PTMT any colour with shower arm (minimum weight 40 grams) 15mm size, 195mm long with bend of 45 degree with flange for fixing with CPVC pipe and taking down old one, complete and all as specified and as directed.
S&F PVC connection pipe 16mm dia (outer 450mm long cold water and taking down old one complete with brass union on both sides to suit 15mm GI pipe and taking down old one, complete all as specified and directed.
S&F in replacement health faucet ABS body with wall hook and 1 metre chrome plated PVC hose pipe, including taking out old one complete all as specified and directed. Make- Cera Model No. F8030107AB or any other equivalent make in the approved manufactures list.
Padmaja Specialities
M.J.JOY AND COMPANY
Bell Builders
WELTRONENGINEERINGSERVICES
SHAIJAL T M
Kurian And Varghese
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .