Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC AT PO PS NEAR INDIAN OIL PETROL PUMP WARD NO 03 CHANDRASEKHARPUR BHUBANESWAR MCD DIST KHURDA ODISHA | BHUBANESWAR | KHURDA | ODISHA | ₹1.1 Cr Quoted ₹1.2 Cr | L1 | Accepted-AOC Lowest Bid Accepted |
| 2 | L2₹1.2 Cr+₹5.9 L (5.09%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹1.2 Cr+₹5.9 L (5.09%) | L2 | Rejected-Finance Not Being Lowest Bidder |
| 3 | L3₹1.5 Cr+₹35.4 L (30.5%)Rejected-Finance MIG 2B 83 H NO 65 5 466 GULLAPALEM SRIHARIPURAM MALKAPURAM POST VISAKHAPATNAM 530 011 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530011 | ₹1.5 Cr+₹35.4 L (30.5%) | L3 | Rejected-Finance Not Being Lowest Bidder |
Tender Value
₹1.3 Cr
EMD Value
₹2 L
Closing Date
12 Aug 2022, 6:00 pmClosed
Shri VK Tiwari, IDSE, Commander Works Engineer
Commander Works Engineers, Station Road, Visakhapatnam - 530 004
SPECIAL REPAIRS TO FIRE ALARM SYSTEMS IN 25 HIGH RISED BUILDINGS AT NAVAL PARK, NORA AND IN 17 HIGH RAISED BUILDINGS AT NEW NAUSENA BAUGH AND PROVISION OF WALK-IN-COOLER IN BLDG No. 108 AT INHS KALYANI UNDER GE NB, VISAKHAPATNAM
2022_MES_536548_1
82263 / E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Visakhapatnam
Class B
Category c vi
9 documents required · 9 mandatory
₹1,000
Garrison Engineer Naval Base
₹2 L
Yes
3 Oct 2022
8 Jul 2022
19 Aug 2022
8 Jul 2022
12 Aug 2022
29 Jul 2022
8 Jul 2022 - 15 Jul 2022
Amount
Supplying, installing, testing and commissioning of Analogue Addressable type Fire Alarm Control Panel with single loop and loop formats expandable upto 8-9 loops, Up to 1000 fire detection zones per network and 200 per panel, with UL/ULC/ LPCB/ FM listed and complying with BS EN 54 Parts 2 and 4 including provision of maintenance free Batteries 12v 18/07Ah- 02 Nos. for 08 Hours backup for normal operation and 15 minutes backup for alarm operation and battery charger complete all as specified and as directed and consisting of the following features:-
Supplying, installing, testing and commissioning of remote microprocessor based GSM- GPRS module as in transmitters/ receiver to transmit/ receive the field data (Fire/Fault/System healthy/Location) to a centralized location i.e., server with a remote wireless GSM/ GPRS enabled SIM card duly inserted in the GSM/ GPRS data logger for sending the field data to a central server for live monitoring and control and storing the data for report generation and analysis at server end including power supply with battery (12 VDC 7AH) alongwith battery charger and Autodialer from server for SMS and Call Alert including supplying and installing of the required SCADA software for GSM - GPRS system all as specified and as directed. Make: Compatible with Honeywell/ Notifier/ Apollo/ Cooper
Supplying, installating, testing and commissioning of the following CPU/Server at centralized locations all as specified and as directed. (a) MINI TOWER SERVER: Mini tower server Sever shall be with the following configuration:- (i) Processor: Intel® Xeon® E3-1225 v5 (3.3GHz/ 8MB/80W) (ii) Memory :- 8GB DDR4 (iii) Total DIMM Slots:- 4 DIMM Slots (iii) Hard Disk Drive:- 1x 1 TB SATA (3.5 inch)7.2k RPM Enterprise Hard Drive & Scalable upto 4 drives (3.5 inch) SATA (iv) On-board Raid (v) ODD:- DVD Writer (vi) Power Supply:- 1 x In-built 290W
(b) DISPLAY: Display shall consist of the following : (i) Monitor : Monitor Pixel Pitch 0.275 mm x 0.275 mm Optimal Resolution 1920 x 1080 at 60Hz Response Time 6ms (grey to grey) Color Support Color Gamut (typical) Contrast Ratio 1000: 1 (typical) 8 Million: 1 (Dynamic) Backlight Technology LED Brightness 250 cd/m2 (typical) (ii) Connectivity : 1 x DP (ver 1.2). 1 x HDMI (ver 1.4). 1 x VGA. 1 x USB 3.0 port - Upstream. 2 x USB 3.0 ports - Side (including 1 x USB3.0 BC1.2 charging port). 2 x USB 2.0 Ports - Bottom. 1 x Analog 2.0 audio line out (3.5 mm jack). (iii) Viewing Angle 178° vertical / 178° horizontal. Height 323.2 mm (iv) Features Security: Security lock slot (cable lock sold separately). Anti-theft stand lock slot (to panel). (v) Flat Panel Mount Interface: VESA (100 mm). (vi) Built-in Devices. USB3.0 super-speed Hub (with 1 x USB upstream port, 2 x USB3.0 and 2 x USB 2.0 downstream ports, including 1x USB 3.0 BC1.2 charging port). (vii) Aspect Ratio 16:9 Display Diagonally Viewable Size: 60.4cm (23.8) Touch resolution 4096 x 4096 Preset Display Area (H X V) 527.04 mm x 296.46 mm (viii) Remote Asset Management (ix) Monitor Panel Type - Surface In-Plane switching Technology color depth 16.7 Million colors Touch Input Bare finger Display Screen Coating Antiglare with 3H hardness touch type Projected Capacitive System Pixel Per Inch (PPI)93 Depth 234.8mm Width 537.8mm Touch point 10 touch-points Touch response time 35 ms (x) Operating system supported Windows 10, 8.1. 7 (xi) Display Manager Compatibility Yes, Easy Arrange and other key features. Make: Dell/HP/Acer
Supplying, installing and testing of Multisensory Detector Heat Cum Smoke detector with base with 5 response modes, drift compensation, user programmable with self built intelligence complying with and type certified to EN 54 and conforming to IS – 11360 comprising of optical smoke and thermistor temperature sensors, to give both combined signal as well as a separate heat signal for improved false alongwith isolator module as required, provided as per area requirement below or above the false ceiling including testing the Detectors using Test fire (Heat & Smoke) as per NFPA 72. complete all as specified and as directed and with following specifications:-
Communications protocol: 5-9V peak to peak Operating voltage: 17-28V DC Quiescent current: 500μA average 750μA peak Power-up surge current: 1mA Maximum power-up time: 10s Alarm LED current: 3.5mA Remote LED current: 4mA at 5V (measured across remote load) Clean air analogue value: 23 +4/-0 Alarm level analogue value: 55 Alarm indicator: 2 colourless Light Emitting Diodes (LEDs); illuminated red in alarm Optional remote LED Dimensions:100mm diameter 50mm height 58mm (height in base) Weight: Detector: 105g Detector in base: 160g Materials: Housing: White polycarbonate V-0 rated to UL94 Terminals: Nickel plated stainless steel Smoke element only: Chamber configuration: Horizontal optical bench housing infra-red emitter and sensor, arranged radially to detect forward scattered light Sensor: Silicon PIN photo-diode. Make: Honeywell/ Notifier/ Appollo/ Cooper
Supplying, fixing and testing of Addressable manual call point, resettable type, having integrally mounted addressable module to monitor and report contact status, type certified to EN 54, with in-built Isolator and LED indicator, IP 44 grade of protection, operated in [-] 10°C to [+] 55°C temperature, complying with allessential requirements of EMC directives including provision of barriers, junction box, mounting accessories, etc. complete all as specified and as directed. Make: Honeywell/ Notifier/ Apollo/ Cooper
Supplying, installing and testing of Addressable electronic loop open area sounder with Visual Indicator to make full use of the protocol, with sound output upto 100 dB, wall mounted stand-alone, and designed for use in indoor and open areas, complete all as specified and as directed. Make: Honeywell/ Notifier/ Apollo/ Cooper
Supplying and fixing of Rigid non-metallic heavy duty PVC Conduit of 25/32mm dia or PVC casing and caping of size 25/ 32mm including all accessories, fixed to walls/ ceilings complete all as specified and as directed.
Supplying, laying, testing and commissioning of 2 Core x 1.50 Sq.mm, Flexible PVC insulated, pair twisted and screened, high conductivity electrolytic copper conductor cable , ISI marked, 1100 Volts, FRLS Grade, both inner and outer PVC sheathed with proper pair identification, conforming to IS 1554 Part -1 & IS 5831, drawn through pipes/ sleeving through pipe in duct including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
Cutting chases, pinning in Brick Walls, making good to facings where required and pointing in Cement Mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed conduiting etc and making good, girth exceeding 10cm but not exceeding 20 cm complete all as specified and as directed.
Dismantling and taking down existing unserviceable Fire alarm control panel of any description and type including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
Dismantling and taking down existing unserviceable Fire alarm repeater panel/ central monitoring system of any description and type including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
Dismantling and taking down existing unserviceable flame/ smoke detectors of any description and type including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
Dismantling and taking down existing unserviceable wall mounted Addressable type horn/ strobe/ Sounder of any description and type including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
Dismantling and taking down existing unserviceable Manual Call points of any description and type including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
Dismantling and taking down existing unserviceable PVC insulated copper conductor cables 2 core x 1.5 sq.mm. size alongwith conduits of any description and size including disconnecting of all connections and making good disturbed surfaces to match with existing all as specified and as directed.
M & L for Powder Coated Aluminium Sections [Minimum 50 Micron thick] of approved colour as in Door, Window, Ventilator Frames, Partitions with one or more rebates and Door, windows shutters sliding/ openable type/ ventilator shutter Aluminium section including necessary Joining Cleats, Glazing Clips, Neoprene Rubber Packing, Powder Coated Aluminium Snap Beading, Screws, Powder Coated Aluminium Fittings such as Locking Arrangement [1 No], Suitable Handle [1 No], Stainless Steel Friction Hinges [1 No] per Window Shutter and 150mm Dia Handles on both sides, Tower bolts, 200 mm Long [2 Nos], Double Action Floor Spring Hydraulically Regulated made of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty etc. per Door Shutter complete all as specified and as directed. Note: [a] The size of aluminium sections shall be all as specified in relevant IS code and MES Schedule Part - I. [b] Supply only panel inserts of Glass / Particleboard / Gauze / Grills will be measured and paid separately. [c] Unit rate quoted shall be deemed to include for cost of rubber beading, glazing clips, neoprene packing, fittings such as Handles, Butt hinges, Tower Bolts, Stainless Steel Friction Hinges and fixing only of panel inserts of Glass / Particleboard / Gauze / Grills etc.
Supply only 5mm thick tinted Glass ordinary quality in squares not exceeding 0.5 Sq.m in each pane complete all as specified and as directed.
Supply only 12mm thick, Prelaminated Particle Board, Decorative Choice Lamination on Both Sides, Medium Density, Exterior Grade complete all as specified and as directed.
Dismantling of Floor, Hearth or Wall Tiling of any description including Cement Mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris to a distance not exceeding 1.5 KM complete all as specified and as directed.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
M & L for Non Skid Ceramic Tiles, Joint Free, Coloured, Premium Quality of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in Vertical Surfaces such as Skirting, Dado etc, set and jointed in neat cement slurry and pointed flush using polymer based cementitious tiling joint filler to match the shade of the tile over backing coat of 10mm thick in Cement Mortar 1:3 complete all as specified and as directed. Note: The colour / shade / design of tiles shall be as approved by GE.
Taking down Chowkats or frame with shutters [without taking off shutter from the frame] exceeding 1.5 Sq.m but not exceeding 4.00 Sq.m each and removing to store complete all as specified and as directed.
Demolition of Brick / Stone Masonry built in Cement Mortar including all quoins arches pillars etc and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for brick work with Fly Ash bricks, straight or curved on plan exceeding 6 m mean radius built in Cement Mortar 1:6 complete all as specified and as directed.
Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key scrubbing down with water etc and removing rubbish to a distance exceeding 1.5 KM but not exceeding 5 KM complete all as specified and as directed.
M & L for rendering to brick / concrete surfaces, 10 mm thick in Cement Mortar 1:6, surfaces finished even and smooth without using extra cement complete all as specified and as directed.
M & L for preparing newly plastered Wall surfaces and applying two coats of Acrylic Washable Distemper over a coat of alkali resistant primer over two or more coats of Cement based Wall Care Putty on walls including rubbing with sand paper to obtain a smooth surface and making good any undulations on the Wall surfaces complete all as specified and as directed.
S & F Stainless Steel Railing made with Stainless Steel Pipes of wall thickness not less than 1.6mm, of Grade AISI 304, standard quality, bright polish finish, using 50mm dia pipes for hand rail, 25mm dia pipes for vertical supports / balusters and 25mm dia pipes as in tie bars in three layers, SS tubes shall be welded at the turnings and junctions, welded portions shall be completely grinded and brought to bright and smooth finish including all bends, elbows, making holes in the floor / steps, grouting with epoxy to achieve full strength of railing complete all as specified and as directed.
Supply, Installing, testing and commissioning of Split type DX type Air cooled Walk-in Cooling unit of capacity 01 Ton for medial storage along with indoor and outdoor units for maintaining desired Temperature of (+)2°C to (+) 8°C with first charge of R-404A refrigerant alongwith refrigerant controllers, suitable for nominal Room of size 10.5'x5.5'x9' [LxBxH] with 8 Nos ( 4 Nos on each side along the length) of Stainless Steel shelves of width 18 inches, with a spacing of 2 feet between shelves including provision of Self-standing Pre fabricated PUF panels for walls & ceiling, PUF slab flooring, SS door swing type with 1mm thick SS sheet of grade 304 on both sides with PUF inuslation alongwith accessories, suitable lock system, Vapour Proof LED Lights, Hooter alarm, Digital Type Temperature Display with Sensor operation, Copper piping for liquid and suction lines with necessary valves, PVC drain piping, inter-connection cables, comprising and including of all the works as specified under Particular Specifications Clause 7 and as per manufacturers instructions.
Supplying, laying and testing XLPE insulated and PVC sheathed, FRLS, armoured heavy duty underground cable, ISI marked with aluminium stranded conductor 1100 Volt grade of size 3.5 Core, 25 Sq.mm cross section suitable for earthed system, laying in trenches/duct/fixed to poles/drawn through pipes/sleeving through pipe in duct, including suitable size Double compression copper stainless steel cable gland, crimping type cable lugs, sockets etc. complete all as specified and as directed.
S & F MCCB DB, VTPN, 8 Way, 415 Volts with DIN Channel, N3 Frame, Double Door with 250 Amps rated bus bar suitable for mounting MCCBs complete all as specified and as directed.
S & F MCCB, TP, 63 Amps, 16 KA, 415 Volts, 50 Hz, suitable for fixing on N3 Frame complete all as specified and as directed.
S & F MCB, TPN, 40 to 63 Amps, 10 KA, B Curve, AC, 230 Volts, 50 Hz complete all as specified and as directed.
Earthing complete with Galvanised Steel Earth Plate Electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of Plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the Plate by means of GI Bolts & Nuts complete all as per Electrical Plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and as directed.
S & F Earth continuity conductor or main earthing lead made of 4 mm GI Wire [Earth Lead] , fixed to wall on batten or recess or chases or burried in ground or fixed to poles or any other indicated situation including drawing through GI Pipe for earthing etc. complete all as specified and as directed.
SAI KRISHNA ASSOCIATES
SRI SURYA PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .