Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.0 LAccepted-AOC 96 SECTOR 16 A CHANDIGARH 160015 | CHANDIGARH | CHANDIGARH | 160015 | 1 | Accepted-AOC LOWEST BIDDER | |
| 2 | 2₹49.7 L+₹1.6 L (3.24%)Rejected-AOC PO PS BANARHAT DIST JALPAIGURI PIN 735202 W B | JALPAIGURI | WEST BENGAL | 735202 | 2 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 3 | 3₹51.2 L+₹3.1 L (6.41%)Rejected-AOC NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | 3 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 4 | 4₹51.9 L+₹3.8 L (7.88%)Rejected-AOC NIL | 4 | Rejected-AOC OTHER THEN LOWEST BIDDER | |
| 5 | 5₹52.8 L+₹4.7 L (9.73%)Rejected-AOC DS COLONY BINNAGURI TG ROAD OPP MILAN SANGH CLUB POST BINNAGURI DISTT JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | 5 | Rejected-AOC OTHER THEN LOWEST BIDDER |
| Sl No | Description | Qty | Unit | SHRI PRADEEP PARIK L4 | ANIL KUMAR GUPTA L1 | M/s Om Prakash Agarwala L2 | M/s AHMED ENGINEERING L6 | N K Construction L3 | M/S SHIVNATH SINGH L8 | M/s. RAMPHAL GARG L7 | M/S RATNESH KUMAR SINGH L5 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches n exc 1.5 mtr wide and n.exc 1.5 mtr deep for laying of cable or pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified | 90.75 | Cum | 425 ₹38,568.75 | 390 ₹35,392.5 | 280 ₹25,410 Lowest | 450 ₹40,837.5 | 403 ₹36,572.25 | 375 ₹34,031.25 | 380 ₹34,485 | 430 ₹39,022.5 |
| 2.00 | Excavation in trenches exc 1.5 mtr wide and n.exc 3.0 mtr deep for laying of cable or pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified | 10 | Cum | 600 ₹6,000 | 540 ₹5,400 | 320 ₹3,200 Lowest | 535 ₹5,350 | 555 ₹5,550 | 395 ₹3,950 | 390 ₹3,900 | 530 ₹5,300 |
| 3.00 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified | 28.71 | Cum | 350 ₹10,048.5 | 140 ₹4,019.4 Lowest | 160 ₹4,593.6 | 250 ₹7,177.5 | 164 ₹4,708.44 | 320 ₹9,187.2 | 310 ₹8,900.1 | 200 ₹5,742 |
| 4.00 | Removing excavated material from site to a distance not exc 50 mtr away and depositing where as directed not exc 1.5 mtr from the starting point all as specified | 72.04 | Cum | 351 ₹25,286.04 | 320 ₹23,052.8 Lowest | 320 ₹23,052.8 Lowest | 400 ₹28,816 | 345 ₹24,853.8 | 462 ₹33,282.48 | 460 ₹33,138.4 | 380 ₹27,375.2 |
| 5.00 | Supply and laying common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenches for protection of cables (LT) complete including taking down old one all as specified | 2.4 | PER 1000 Nos. | 7,067 ₹16,960.8 | 7,000 ₹16,800 | 9,500 ₹22,800 | 7,010 ₹16,824 | 7,015 ₹16,836 | 6,999 ₹16,797.6 | 7,000 ₹16,800 | 6,990 ₹16,776 Lowest |
| 6.00 | M&L for sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punning thickness up to 18 cm and consolidation, complete all as specified
Note: Punned down thickness upto 18cm shall only be measured and paid. | 24.3 | Cum | 2,200 ₹53,460 | 2,100 ₹51,030 | 1,800 ₹43,740 Lowest | 2,250 ₹54,675 | 2,160 ₹52,488 | 2,130 ₹51,759 | 2,150 ₹52,245 | 2,200 ₹53,460 |
| 7.00 | Supply and fixing in replacement of Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos LED all as specified | 20 | Each | 7,495 ₹1,49,900 | 7,500 ₹1,50,000 | 12,000 ₹2,40,000 | 7,450 ₹1,49,000 Lowest | 7,540 ₹1,50,800 | 7,553 ₹1,51,060 | 7,550 ₹1,51,000 | 7,485 ₹1,49,700 |
| 8.00 | Supply and fixing in replacement of GI tubes 25 mm bore, medium grade, galvanised for fixing of aviation light on RCC/Steel OHT by grouting in PCC/ saddling/ welding all as specified | 120 | RM | 305 ₹36,600 | 200 ₹24,000 Lowest | 280 ₹33,600 | 365 ₹43,800 | 279 ₹33,480 | 505 ₹60,600 | 500 ₹60,000 | 350 ₹42,000 |
| 9.00 | M&L for PCC in foundation, for construction of coping for GI pipe 25/40 mm dia on RCC OHT for fixing of air termination rod/ aviation light pipe etc in PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) complete all as specified | 3.2 | Cum | 10,600 ₹33,920 | 10,500 ₹33,600 | 9,500 ₹30,400 Lowest | 20,505 ₹65,616 | 10,570 ₹33,824 | 20,405 ₹65,296 | 20,400 ₹65,280 | 20,490 ₹65,568 |
| 10.00 | Supply, laying in trenches or saddling on RCC/steel piller/beam/ wall of OHT and testing cable XLPE Insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Voits grade with stranded aluminium conductor of size 6 Sqmm 2 core complete including taking down old one all as specified | 600 | RM | 185 ₹1,11,000 | 150 ₹90,000 Lowest | 180 ₹1,08,000 | 215 ₹1,29,000 | 200 ₹1,20,000 | 230 ₹1,38,000 | 225 ₹1,35,000 | 222 ₹1,33,200 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Oct 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (S) Binnaguri
GE (SOUTH) BINNAGURI, PO - BINNAGURI, DISTT - JALPAIGURI, PIN - 735232
As per tender docus
2025_MES_730797_1
8824/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (S) Binnaguri
Class D and Category b(i)
7 documents required · 7 mandatory
₹500
GE (S) Binnaguri
₹90,000
Yes
9 Dec 2025
25 Sept 2025
23 Oct 2025
25 Sept 2025
16 Oct 2025
9 Oct 2025
25 Sept 2025 - 9 Oct 2025
Amount
Excavation in trenches n exc 1.5 mtr wide and n.exc 1.5 mtr deep for laying of cable or pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified
Excavation in trenches exc 1.5 mtr wide and n.exc 3.0 mtr deep for laying of cable or pipe line in any type of soil, getting out and leveling of bottom surface to required level all as specified
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick all as specified
Removing excavated material from site to a distance not exc 50 mtr away and depositing where as directed not exc 1.5 mtr from the starting point all as specified
Supply and laying common burnt, clay building bricks, sub class 'B' designation over the sand cushioning in cable trenches for protection of cables (LT) complete including taking down old one all as specified
M&L for sand cushioning to UG cables (8 cm deep before laying of cable and 15 cm deep over the cable) in trenches including punning thickness up to 18 cm and consolidation, complete all as specified Note: Punned down thickness upto 18cm shall only be measured and paid.
Supply and fixing in replacement of Integral LED aviation light comprising of aluminium housing with polycarbonate enclosure, 302 Nos LED all as specified
Supply and fixing in replacement of GI tubes 25 mm bore, medium grade, galvanised for fixing of aviation light on RCC/Steel OHT by grouting in PCC/ saddling/ welding all as specified
M&L for PCC in foundation, for construction of coping for GI pipe 25/40 mm dia on RCC OHT for fixing of air termination rod/ aviation light pipe etc in PCC (1:3:6) type C-1 (using 20 mm graded stone aggregate) complete all as specified
Supply, laying in trenches or saddling on RCC/steel piller/beam/ wall of OHT and testing cable XLPE Insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Voits grade with stranded aluminium conductor of size 6 Sqmm 2 core complete including taking down old one all as specified
Supply, laying in trenches and testing cable XLPE Insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Voits grade with stranded aluminium conductor of size 95 Sqmm 3.5 core complete including taking down old one all as specified
Supply, laying in trenches and testing cable XLPE Insulated screened, PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Voits grade with stranded aluminium conductor of size 185 Sqmm 3.5 core complete including taking down old one all as specified
S&F pole junction box made out of polycarbonate with IP-65 protection of suitable size (approx 205 x 255 x 112 mm) including, pole mounting MS clamps, 04 Nos cable terminal, 02 Nos polycarbonate cable gland, 01 Nos DIN rail and 01 Nos MCB SP, 10KA 6 Amps complete including taking down old one all as specified
S&F aluminium strip 25 x 3.15 mm on top of RCC OHT with saddles & fixing screws etc, for earth continuity conductor main earthing lead, down conductors above ground suitably fixed to wall or and connected to test point including porcelain insulators, GI bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints including making good the disturbed surfaces including all necessary fixing arrangement for lightning protection complete including taking down old one all as specified
S&F air termination single pointed aluminium rod 12mm dia and 300 mm long on top of RCC OHT complete including taking down old one all as specified
S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 Nos 8 mm dia, 25 mm long hexagonal head screw complete including taking down old one all as specified
M&L for GI Pipe light grade, 40 mm dia for fixing of air termination single pointed aluminum rod of 12mm dia, 300mm long on the roof of RCC/Steel OHT for effective lightning protection system complete including taking down old one all as specified
Materials and labour for Earthing complete with MS galvanized Earth Plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 25x4 mm galvanized iron strip by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point including providing funnel and watering pipe 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (using 20mm graded stone aggregate), 50mm thick precast RCC (1:2:4) type B1 (using 20mm graded stone aggregate) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work, excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I (2009) complete including test point and testing on completion including taking down old one all as specified
M&L for fabrication for errecting/ fixing mild steel Stairs (framed) including stringers, treades, landing, balusters, hand rails etc. including cleats, brackets etc for RCC OHT ladder supportings, ladder railing, RCC OHT manhole covers on roof along with locking arrangement by using MS flats/ plates/ angles/ nut bolts conforming to Fe 410 W (Gde E-250) Quality A including taking down old one complete all as specified
M&L for preparation of old painted steel/ iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying a coat of synthetic enamel paint complete all as specified
M&L for preparation of new or previously untreated steel/ iron surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified
M&L for PCC (1:4:8), type D2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete including demolition of existing concrete complete all as specified
M&L for RCC M-25 (design mix) (using 20 mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete including demolition of existing concrete complete all as specified
M&L for RCC M-25 (design mix) (using 20 mm graded stone aggregate) as in columns, pillars, piers, posts and struts complete all as specified
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified
M&L for TMT bar 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified
Use and waste of formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work vertical or to rough finished flat surfaces
Use & waste of formwork to sides of pillars, posts, struts, piers, columns and stanchions square, rectangular or polygonal in shape having rough finished surface of concrete complete all as specified
M&L for rendering 20mm thick in two layers (10mm + 10mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with WPC in outer layer on wall surface and finishing even and fair complete all as specified Note:- WPC shall be measured and paid sparately.
Supply only liquid water proofing compound.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting plates conforming to Fe-410W (Gde-E-250) quality-A also fastening and fixing complete including dismantling old mild steel complete all as specified
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5/ 4 core XLPE, armoured, aluminium conductor cable of size 25-50 sqmm complete including taking down old one all as specified
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 70-95 sqmm complete including taking down old one all as specified
S&F cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material heat shrink type and accessories suitable for 3.5 core XLPE, armoured, aluminium conductor cable of size 120-185 sqmm complete including taking down old one all as specified
Material & labour for replacement of rusted/corroted security light bracket made out of GI pipe of light grade 1.6 Rm x32 mm dia for inserting of light fitting, properly shaped, bended & fixed on the pole through MS flat by nut, bolt & washer of suitable sizes incl dismantling the old unsv existing one complete all as specified
S&F LED street light epoxy powder coated pressure die-cast aluminium housing with weather proof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 6000 lumen, system wattage 60 Watt, Ingress protection IP-66 with all acessories complete including taking down old one all as specified
S&F LED flood light epoxy powder coated pressure die-cast aluminium housing with weather proof gasket for LEDs with lens and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-270 Volts, delivering lumen equal to/greater than 10000 lumen, system wattage 100 Watt, Ingress protection IP-66 with all acessories complete including taking down old one all as specified
S&F Flexible PVC insulated multicore FRLS PVC sheathed multistranded copper conductor cable of 1.5 Sqmm x 3 core for voltage grade up to 1100 V conforming to IS 694 : 2010 for connection of light fitting from junction box or from over head conductors to fitting complete including taking down old one all as specified
Supply, install, comissioning and testing of wall mounted LT Indoor type weather proof dust/vermin proof Powder Coated electrical panel made out of 2 mm CRCA sheet and factory made fabricated duly powder coated, front openable with locking arrangements with the following acessories including taking down the old unsv panel disconnecting existing cables and reconnecting the cables to new panels vertical Copper bus bar 200 Amps min for 3 phase and Neutral incl current transformer & danger notice plate complete all as specified Main incoming : a) MCCB FP 160 Amps, 415 Volts, 36 KA - 01 No Outgoing: a) MCCB TP 100 Amps, 415 Volt, 25 KA - 01 No b) MCCB TP 63 Amps, 415 Volt, 16 KA - 01 No c) MCB SPN 32 Amps, 415 Volt, 10 KA - 01 No d) Digital Ammeter e) Digital Voltmeter f) RYB Indicators - 1 Set
Material & labour for retermination of burnt/brittle cable end of size 25 to 95 Sqmm 3.5/4 core LT XLPE cable in any position by excavating the loop of cable or de-saddling from wall after cutting the damaged portion of cable and provide suitable size of aluminium lugs 04 Nos, one Nos SS cable gland, SS nut bolts, washers and spider links of MCCB where as required at site by using proper crimping tools complete including making good disturbed surface and taking down old one all as specified
Material & labour for retermination of burnt/brittle cable end of size 120 to 185 Sqmm 3.5 core LT XLPE cable in any position by excavating the loop of cable or de saddling from wall after cutting the damaged portion of cable and provide suitable size of aluminium lugs 04 Nos, one Nos SS cable gland, SS nut bolts, washers and spider links of MCCB where as required at site by using proper crimping tools complete including making good disturbed surface and taking down old one all as specified
Material & labour for refixing the existing starter 20 to 50 HP capacity on wall or panel after removing from existing position, disconnection of cables and reterminating the cable ends by using proper size of copper lugs/thimbles by using proper crimping tools complete including making good disturbed surface all as specified
M/s Om Prakash Agarwala (BID ID -3449234)
N K Construction (BID ID -3450635)
SHRI PRADEEP PARIK (BID ID -3448071)
M/S RATNESH KUMAR SINGH (BID ID -3448173)
M/s AHMED ENGINEERING (BID ID -3449262)
M/s. RAMPHAL GARG (BID ID -3451154)
M/S SHIVNATH SINGH (BID ID -3450811)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
8824-Date_1.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .