| Sl No | Description | Qty | Unit | Kalap Engineers and Builders L3 | NATHU RAM AND SONS L6 | M/S PARMOD KUMAR L5 | B S Ranbir & Co. L2 | J B ELECTRICALS L4 | ess are electricals and electronic L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply only XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down complete all as specified and directed by Engr-in-charge and directed as follows : | |||||||||
| 1.01 | 10 Sqmm x 2 Core | 100 | RM | 170 ₹17,000 | 300 ₹30,000 | 240 ₹24,000 | 180 ₹18,000 | 250 ₹25,000 | 135 ₹13,500 |
| 1.02 | 16 Sqmm x 4 Core | 200 | RM | 300 ₹60,000 | 500 ₹1,00,000 | 420 ₹84,000 | 280 ₹56,000 | 300 ₹60,000 | 215 ₹43,000 |
| 2.00 | Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved and tested Street Light TIme switch Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work ( made out of 40 mm X 40 mm X 6 mm thick ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035 embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm, Make of Panel Board:- Adlec/ Schneider / Universal Switch Gear Control/ Tricolite.The scope of work also comprising of the following:- | 1 | Each | 1,15,000 ₹1,15,000 | 1,80,000 ₹1,80,000 | 1,15,000 ₹1,15,000 | 55,000 ₹55,000 | 1,15,000 ₹1,15,000 | 1,31,250 ₹1,31,250 |
| 2.01INSTRUMENTS:- (i) Red, Yellow, Blue Phase indicating light LED type- 01 Set. (ii) Control MCB 6 A SP C Series - 1 Set. INCOMING:- (i) MCB 63 Amps, 4 Pole, 10 KA, 50 Hz, 415 Volts-01 No. Make: L&T/ Havells / Legrand (ii) Power Contactor 3 Pole, 32 Amps. 50 Hz, 220 Volts- 01 No. Make: L&T/ Havells/ ABB or equivalent. (iii) Automatic astronomical Timer Switch with battery backup of 100 hours, Programmable every 4 Hours current capacity 16 Amps 240/415 Volts, 50 Hz- 01 No. Make: L&T/ Havells or equivalent. (iv) Auto Manual Selector Switch 6 A SP- 01 No. Make: L&T/Schneider/Kaycee. (v) RED Phase indicating light LED type- 01 No.. Make: L&T/Vishnu/ Schneider/ C&S. (vi) Outgoing Terminal 4 Way - 1 Set. Make: Master/FTC/Connectwell. Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring 10 Sqmm flexible. Note: In Case of failure, manual system should also be provided. | |||||||||
| 2.02The panel manufacturer should have following Govt. Approved Certificates: 1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011) 2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011) 3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk 4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V 5. ISO 9001 CERTIFIED | |||||||||
| 2.03Note : Unit rate quoted by the contractor here-in-before also includes for installation of panel on suitable PCC foundation and PCC platform incl necessary earth and PCC work all as per manufacturer instructions and as directed by the Engr-in-Charge. | |||||||||
| 3.00 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sqmm complete all as specified and as directed by Engr-in-charge. | 220 | RM | 250 ₹55,000 | 300 ₹66,000 | 460 ₹1,01,200 | 425 ₹93,500 | 300 ₹66,000 | 450 ₹99,000 |
| 4.00Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required for following: | |||||||||
| 4.01 | 16 Sqmm x 2 Core | 2 | Each | 200 ₹400 | 1,500 ₹3,000 | 2,945 ₹5,890 | 1,500 ₹3,000 | 2,500 ₹5,000 | 6,000 ₹12,000 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
10 Jun 2026, 6:00 pmClosed
Sh K K Soni AE (Civ) AGE I R and D Manali
AGE I R AND D MANALI PIN 175103 PH 01902255014
REPAIR TO STREET PANEL AND MISC WORK OF AREA LIGHTINGS AT TRANSIT CAMP PALCHAN UNDER AGE(I) R AND D MANALI
2026_MES_765092_1
AGE(I)/MNL-17/2026-27
Open Tender
Electrical and Maintenance Works
180 days
Palchan
As per NIT and tender documents
5 documents required · 5 mandatory
₹500
AGE I R AND D MANALI
₹18,000
Yes
2 Jul 2026
13 May 2026
12 Jun 2026
13 May 2026
10 Jun 2026
27 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply only XLPE insulated armoured cable (heavy duty) electric cable with aluminium stranded conductor 1100 volts grade of following size after taking down complete all as specified and directed by Engr-in-charge and directed as follows : | |||||
| 1.01 | 10 Sqmm x 2 Core | 100 | RM | - | - |
| 1.02 | 16 Sqmm x 4 Core | 200 | RM | - | - |
| 2 | Supply, installing, testing and commissioning factory made LT ( 415 Volts, 50 Hz , 3-phase, 4 wire supply ) CPRI approved and tested Street Light TIme switch Outdoor type, platform mounted, suitable for 415 Volts 3 Phase and neutral, 4 wire, 50Hz AC supply system. The panel shall be dust and vermin proof, protection class ( IP-54 ) and made of 3.15 mm thick CRCA mild steel sheet and mild steel angle iron frame work ( made out of 40 mm X 40 mm X 6 mm thick ), front opening type with proper ferrule & cable gland, internal wiring with PVC insulated multistranded copper conductor FR cable of adequate size but not less than 1.5 sqmm complete. All steel metal works including frame shall be with anticorrosive coating with seven tank process and finally epoxy polyester powder coating of Siemens grey shade 7035 embedded in ground with and including bocks of PCC 1:2:4 type B1 of block size 30x30x30 cm, Make of Panel Board:- Adlec/ Schneider / Universal Switch Gear Control/ Tricolite.The scope of work also comprising of the following:- | 1 | Each | - | - |
| 2.01 | INSTRUMENTS:-
(i) Red, Yellow, Blue Phase indicating light LED type- 01 Set.
(ii) Control MCB 6 A SP C Series - 1 Set.
INCOMING:-
(i) MCB 63 Amps, 4 Pole, 10 KA, 50 Hz, 415 Volts-01 No. Make: L&T/ Havells / Legrand
(ii) Power Contactor 3 Pole, 32 Amps. 50 Hz, 220 Volts- 01 No. Make: L&T/ Havells/ ABB or equivalent.
(iii) Automatic astronomical Timer Switch with battery backup of 100 hours, Programmable every 4 Hours current capacity 16 Amps 240/415 Volts, 50 Hz- 01 No. Make: L&T/ Havells or equivalent.
(iv) Auto Manual Selector Switch 6 A SP- 01 No. Make: L&T/Schneider/Kaycee.
(v) RED Phase indicating light LED type- 01 No.. Make: L&T/Vishnu/ Schneider/ C&S.
(vi) Outgoing Terminal 4 Way - 1 Set. Make: Master/FTC/Connectwell.
Panel wiring for control circuit with copper flexible 1.5 Sq mm & power wiring 10 Sqmm flexible.
Note: In Case of failure, manual system should also be provided. | - | - | - | - |
| 2.02 | The panel manufacturer should have following Govt. Approved Certificates:
1. Panel should be according to IEC-61439. CPRI Certification Degree of Protection IP-54 (IS/IEC : 61439 (Part-1), 2011 & IS/IEC : 61439 (Part-2) 2011)
2. Tempreature Rise (IS/IEC : 61439-1, 2011 & IS/IEC : 61439-2 2011)
3. CPRI Short Circuit IEC-61439-1 & 2 withstand strenght should be 70kArms for 1.0 Sec with intial peak of 154kApk
4. CPRI Certification IEC-61439-1 & 2 Rated current for short circuit not less than 6300 A with rated insulation voltage 660V
5. ISO 9001 CERTIFIED | - | - | - | - |
| 3 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required upto 35 sqmm complete all as specified and as directed by Engr-in-charge. | 220 | RM | - | - |
| 4Supplying and making straight through joint with cast resin compound including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required for following: | |||||
| 4.01 | 16 Sqmm x 2 Core | 2 | Each | - | - |
| 4.02 | 16 Sqmm x 4 Core | 2 | Each | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.24 MB
TenderDocuments172627EM.pdf
Tender Documents • 0.95 MB
BOQ_856906.xls
BOQ • 9.32 MB
Download all tender documents and submit your bid