Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.9 LAccepted-AOC MANNIKKUNNAN HOUSE VELLIYANCHERI POST MALAPPURAM DIST | KANNUR | KERALA | 670612 | L1 | Accepted-AOC LI | |
| 2 | Rejected-Technical | - | Rejected-Technical L2 |
Tender Value
₹2.9 L
EMD Value
₹7,256
Closing Date
22 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Secretary
Alanallur Grama Panchayat Office, Alanallur Post Palakkad
Annual Plan-Alanallur Grama Panchayath 2023 24 Project No 400/24 Renovation of Electrical work in Old Panchayat Office and president Capin- Eleterification Work
2024_DP_670394_1
ALR/400/2023-24
Open Tender
Electrical Works
Item Rate
120 days
Alanallur Grama Panchayat
Please refer Tender documents.
9 documents required · 9 mandatory
₹645
Yes
₹7,256
Yes
30 Dec 2024
15 Mar 2024
25 Mar 2024
15 Mar 2024
22 Mar 2024
15 Mar 2024
Amount
Electrification of old grama panchayath office and cabin of president
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
90.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
90.2.1.6:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
90.2.1.7:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Independent plug - Short point
OD422962/2023-2024:Supply and fixing LAN patch chord length 2 mtr crimped properly at both ends using connectors including all charges. Digisol/Equivalent
OD422963/2023-2024:Supply and fixing of standard graded CAT 6 information Outlet (I/O) box in recess/surface with single port and RJ45 face plate having following minimum specifications :86 type standard, front access with spring shutter, easy identification labels or RJ45 port etc. and OEM surface Box having rigid plastic body and giving connection properly with the incoming CAT 6 UTP cable ,testing the connection, making good the damages, colour washings etc. (Recommended: MOLEX/ COMMSCOPE/ LEGRAND)
OD422964/2023-2024:Supply,conveyance installation testing and commissioning of pre-wired square type 18w LED fitting (10" x 10") complete with all accessories and drives etc. Lumen out put not less than 1800 efficiency not less than 100lumen/watt duly fixed on false ceiling and giving connection etc. as required. (for fitting in false ceiling) make Philips/Crompton/Bajaj/Wipro or equivalent make.
OD422965/2023-2024:Supply, conveyance, installation, testing of PA Microphone Stands with following minimum specifications. Floor Stand, Height - 920-1500 mm, Base Dia - 230mm, Weight - 5.6 Kg. Recommended: DGN-AHUJA.
OD422966/2023-2024:Supply, conveyance, installation, testing of dynamic microphone having 50Hz16,000Hz frequency response,with XLR connectors & 6.5M low noise cable.It should be ideal for speech, vocal and dynamic instrument miking. (Recommended: ASM?580 XLR Ahuja or Equivalent)
OD422967/2023-2024:Supply, conveyance, installation, testing of Handheld PA Wireless Microphone with dual channel non diversity wireless receiver having following minimum specifications. Frequency response 50 -15,000Hz (Recommended: AWM - 700UH Ahuja or Equivalent)
OD422968/2023-2024:Supply, conveyance, installation, testing and giving connection of wall mounting Speaker Box of 60 Watts rms, 6" Woofer & 1" Tweeter speakers, Power taps of 60W/30W/15W/7.5W, 8 Ω on 100V, frequency response 90Hz ‐20KHz. including wall mount bracket.(Recommended: ARC 60 Studiomaster or Equivalent)
OD422969/2023-2024:Supply, conveyance, installation, testing and giving connections of two zone PA Amplifier 250W RMS operating on AC 220‐ 240V, 50Hz/DC, and having 50‐ 15,000 Hz ±3dB frequency response, Bass, Treble and Master Control, 6 mic input channel, 2 Auxiliary inputs, 4, 8 Ohms, 70V & 100V speaker outputs in each zone. Recommended: SSA - 250 DP AHUJA or Equivalent.
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
1.17.2:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 1.5 sq. mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.13:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 2.5 sq. mm
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
1.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.5:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
1.53.1:Supplying and drawn of UTP 4 pair CAT 6 LAN cable in the existing surface/recessed steel/PVC conduit as required1 run of Cable
90.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
90.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
Sanju Rajan
Bidder Name
YAHKOOB M K
Sanju Rajan
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1043254.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .