Replacing the existing DB and modification of UPS Connection at Health centre
2025_NITC_860710_1
Engg/EMU/AE-101/Health centre/2025
Open Tender
Electrical Works
Item Rate
30 days
NIT Calicut, NIT Calicut Campus PO, 673601
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹4,200
Yes
1 Jul 2025
19 May 2025
11 Jun 2025
19 May 2025
9 Jun 2025
19 May 2025
Amount
Supplying and drawing 3 x 2.5 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing 3 x 4 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Supplying and drawing 3 x 6 sq. mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Wiring for circuit/ submain wiring alongwith earth wire with the 4 x16 sq.mm + 2 x 6 sq.mmof FRLS PVC insulated copper conductor, single core cable in surface/ recesssed medium class PVC conduit as required.
Supplying and fixing of 20 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 25 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing of 32 mm of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular switch socket outlet and 15/16A modular switch , connections etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Double pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 4 pole MCB metal enclosure on surface / recess, complete with earth bar, din bar, detached gland plate, interconnection, phosphetized and powder painted including earthing etc. as required.
Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 63A rating, Four pole, (Three phase and neutral), 415 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing single pole blanking plate in the existing MCB SB complete etc.as required.)
Supplying of one number 3.5 C x 70 Sq.mm size Aluminium conductor XLPE insulated PVC sheathed power cable of 1.1 kV grade etc. as required.
Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of above 35 sq. mm Upto 95 sq. mm (clamped with 1mm thick saddle) size on wall surface/pipe as required.
Supply and laying of one number of 8 SWG good quality bare copper wire for loop earthing along with existing XLPE insulated aluminium cable as required.
Supply and making end termination with brass compression gland and aluminium legs for 3.5 C x 70sq.mm (32 mm) size of XLPE insulated PVC sheathed armoured aluminium cable as required.spacing not exeed 50 cm etc. as required.
Supplying and fixing 3 phase 8 way(4+24) , double door, vertical type three pole and neutral ,sheet steel,MCB distribution board,415 V on suface/recess mounting, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of four pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 12 way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Providing and fixing 125 A, 36 KA, FPMCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel,making connections ,etc.as required.
Supplying and fixing 63 A rating, 415 V, 10kA, "C" curve miniature circuit breaker suitable for inductive load of three pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Charges for removing the old wall mounted DB's, making good the damages of the wall/ floor including painting, dismantle the DB and other accessories without any damage and conveyance of the material to the godown etc, as required.
Supplying and making end termination of suitable size for the submain wiring with suitable lugs for 4 x 16 + 2 x 6 sqmm of PVC insulated copper conductor.
Supplying and fixing 20/25 A modular DP switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 3 pin 25 A modular socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
Supplying and fixing 1/2 module, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 3 phase 6 way , double door, suface/recess mounting, vertical type, 415 V, TPN distribution board with provision for fixing MCCB as incomer and TP MCB as out going, complete with 200 A tinned copper bus bar, common neutral link, earth link, din bar for mounting MCBs, detachable gland plate, interconnections, earthing, phosphatized and powder painted, fixing using bolt and nut, giving connections etc. as required. (But without MCCB, MCB etc)
Charges for cleaning and spray painting the existing Panel board of 180 x 95 x 40 or nearest size with two coats of suitable colour (Grey) paint, over a coat of primer in installed position and marking the identification of switches with white paint etc, as required
Fabrication & fixing of 123 x 93 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.
Fabrication & fixing of 94 x 42 cm panel board Sheet made from 2 mm thick MS sheet, powder coated in suitable colour over a coat of primer, providing rubber beadings and suitable size hinches, Nuts & Bolts for fixing on the existing panel board etc. as required.
Sivaprathapan KB (BID ID -3228814)
DIAMOND ENGINEERING WORKS (BID ID -3229040)
LAMOS TECHNOLOGY SOLUTIONS PVT LTD (BID ID -3227271)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .