Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H3₹4.5 L−₹2.0 L (31.0%)Accepted-AOC INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | H3 | Accepted-AOC Being L1 | |
| 2 | H1₹6.5 LRejected-Finance 203 NABIL APARTMENT ASHOK NAGAR OPP HATHIKHANA ANAJ MARKET TULSIWADI ROAD KARELIBAUG VADODARA 390018 GUJARAT | VADODARA | GUJARAT | 390018 | H1 | Rejected-Finance Being not L1 | |
| 3 | H2₹5.4 L−₹1.2 L (17.7%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | H2 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | jagdish machinery stores H3 | FAIZA ENTERPRISE H1 | Hirachand Sunderji and co H2 |
|---|---|---|---|---|---|---|
| 1.00 | M & L for Servicing, repairs & maint to package type A/C plant of capacity 11 / 16.5 TR comprises with out door/indoor unit of make BLUE STAR by frequent visit as directed by Engr-in-charge during contract period and attending the complaints as reported and relaplacing the unserviceable parts of the machine including labour only for charging of Refrigerant gas, leak testing, Brazing the suction / discharge tubes repalce V belt where required and cleaning of Condensing unit, all strainer, Checking/repairs to sensor unit, HP/LP cut off valve for proper functioning and replace where required/ordered all as directed and testing complete on completion.
Note :- (i) Parts of package type A/C Plant of Blue Star make as required for repair/replacement shall be measured and paid seperately as supply only rate as under.
(ii)Gas will be measured and paid seperatly.
Note :- Spare parts shall be measured and paid for separately under respective items of BOQ as supply only. | 5 | Each Job | 12,000 ₹60,000 | 10,000 ₹50,000 Lowest | 12,500 ₹62,500 |
| 1.01 | Supply only Sealed Compressor unit of capacity 5.5 TR three phase 415 Volt, 50Hz | 1 | Each | 50,000 ₹50,000 Lowest | 70,000 ₹70,000 | 60,000 ₹60,000 |
| 1.02 | Supply only PCB for 11/16.5 TR Package type as per existing board make and model or as per site requirement complete all as specified and directed | 3 | Each | 15,000 ₹45,000 Lowest | 35,000 ₹1,05,000 | 17,500 ₹52,500 |
| 1.03 | Supply only Contactors for blower motor and compressor | 5 | Each | 2,000 ₹10,000 | 1,000 ₹5,000 Lowest | 1,950 ₹9,750 |
| 1.04 | Supply only Expansion valve | 3 | Each | 3,000 ₹9,000 Lowest | 3,000 ₹9,000 Lowest | 3,500 ₹10,500 |
| 1.05 | Supply only Dryers | 5 | Each | 1,000 ₹5,000 Lowest | 2,000 ₹10,000 | 1,250 ₹6,250 |
| 1.06 | Supply only Fan motor for 11 TR plant outdoor unit | 2 | Each | 5,500 ₹11,000 Lowest | 8,000 ₹16,000 | 6,000 ₹12,000 |
| 1.07 | Supply only HP relay switch for compressor unit of 11 TR / 16.5 TR AC plant | 8 | Each | 1,000 ₹8,000 Lowest | 2,000 ₹16,000 | 1,250 ₹10,000 |
| 1.08 | Supply only LP relay switch for compressor unit of 11 TR / 16.5 TR AC plant | 8 | Each | 1,000 ₹8,000 Lowest | 2,000 ₹16,000 | 1,250 ₹10,000 |
| 1.09 | Supply only SPDT relay switch for 11 TR / 16.5 TR plant outdoor unit | 5 | Each | 650 ₹3,250 Lowest | 2,500 ₹12,500 | 850 ₹4,250 |
Tender Value
₹4.5 L
EMD Value
₹9,000
Closing Date
10 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Harikesh Meena EE
Opp Akashwani, Makarpura road PO-ONGC Baroda-390009
As per BOQ
2025_MES_731763_2
8901
Open Tender
Civil Works
Item Rate
270 days
GE ARMY BARODA
As per tender documents
9 documents required · 9 mandatory
₹300
Yes
GE ARMY BARODA
₹9,000
Yes
27 Dec 2025
27 Oct 2025
11 Nov 2025
27 Oct 2025
10 Nov 2025
4 Nov 2025
Amount
M & L for Servicing, repairs & maint to package type A/C plant of capacity 11 / 16.5 TR comprises with out door/indoor unit of make BLUE STAR by frequent visit as directed by Engr-in-charge during contract period and attending the complaints as reported and relaplacing the unserviceable parts of the machine including labour only for charging of Refrigerant gas, leak testing, Brazing the suction / discharge tubes repalce V belt where required and cleaning of Condensing unit, all strainer, Checking/repairs to sensor unit, HP/LP cut off valve for proper functioning and replace where required/ordered all as directed and testing complete on completion. Note :- (i) Parts of package type A/C Plant of Blue Star make as required for repair/replacement shall be measured and paid seperately as supply only rate as under. (ii)Gas will be measured and paid seperatly. Note :- Spare parts shall be measured and paid for separately under respective items of BOQ as supply only.
Supply only Sealed Compressor unit of capacity 5.5 TR three phase 415 Volt, 50Hz
Supply only PCB for 11/16.5 TR Package type as per existing board make and model or as per site requirement complete all as specified and directed
Supply only Contactors for blower motor and compressor
Supply only Expansion valve
Supply only Dryers
Supply only Fan motor for 11 TR plant outdoor unit
Supply only HP relay switch for compressor unit of 11 TR / 16.5 TR AC plant
Supply only LP relay switch for compressor unit of 11 TR / 16.5 TR AC plant
Supply only SPDT relay switch for 11 TR / 16.5 TR plant outdoor unit
Supply only Heating condensing coil for 11 TR / 16.5 TR plant Outdoor unit
Supply only Evaporator coil for 11 TR / 16.5 TR plant indoor unit
Supply only Temperature Sensor for 11 TR / 16.5 TR plant
Supply only MCCB 63 Amps 4 Pole 16 KA 415 Volt, 50Hz
Supply only MCCB 163 Amps 4 Pole 16 KA 415 Volt, 50Hz
Supply only Fan motor for 16.5 TR plant outdoor unit
Repair only PCB for 11/16.5 TR Package type as per existing make and model or site requirment PCB card for split AC for indoor unit.
Repair / Rewinding of Blower Motor of Capacity 3/4 HP by taking out burnt winding wires from core, cleaning thoroughly and rewinding the same with bar insulated copper winding wire of proper gauge and turn to achieve required r.p.m and install the motor at its existing position and connected with the system. Existing DE and NDE bearings to be replaced with new bearings (SKF/NBC) and cost is deemed to be included with unit rate.
Supply of Charging Refrigerant gas R-407
Comprehensive maintenance/Servicing of air conditioners of Split type AC 1.0/1.5 Ton capacity installed at various location, including oiling/greasing the blower motor, bearings etc, cleaning the air filter pad, evaporator, condensor coils filter externally to remove the dust, replacement of defective parts all as directed by Engr-In Charge (Comprehensive maintenance also includes dismantling of outer/inner unit of spilit AC/window AC of any capacity after repairing the AC will be re-installed properly to same place). Note:- Spare parts, gas charging shall be measured and paid separately. Note: (i) T&P & suitable ladder required at site is responsible to the contractor.
All as per item no 5 but Split type AC 2.0 Ton capacity
Supply and fixing in replacement of inverter/Non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Supply and fixing in replacement of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for outdoor unit.
Repair only of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Repair only of inverter/non inverter PCB of capacity 1.5 Ton for split AC as per existing make and model or site requirment PCB card for split AC for indoor unit.
Supply and fixing in replacement of Blower motor 1/5 HP single phase F.H.P. type 230 volts 50 Hz for window type AC including connecting, testing & commissioning(as per site model). Make : GE/Polar/Crompton
Supply and fixing in replacement of Starting capacitor suitable for window/split type AC capacity upto 2.0 Ton
Supply and fixing in replacement of Running capacitor suitable for window /split type AC capacity upto 2.0 Ton
S & F in replacement of Fan/Blower blade for split type AC upto 1.5 Ton capacity all as specified and directed by Engr-In-Charge
S & F in replacement of Blower motor for indoor unit of 1.5Ton capacity split type AC. Make : ISI marked
S & F in replacement of Blower motor for indoor unit of 2.0 Ton capacity split type AC. Make : ISI marked
S & F in replacement of Condensor fan motor for outdoor unit of split type AC 1.5 Ton capacity
S & F in replacement of Condensor fan motor for outdoor unit of split type AC 2.0 Ton capacity
S & F in replacement Split AC drain pipe of 12' complete for split AC of any make as site requirement of capacity upto 2.0 ton with all accessories all fitting and necessary connection all as specified and directed by Engr-in-Charge.
Note:For Item No 1 to 18:-(i) During DLP/contract running time, contractor shall be liable with manufacture to provide replacement/repair the unservicable items with any extra cost. (ii) If any above AC and package AC plant be come breakdown, the contractor shall locate the breakdown/fault at site within 12 hrs on intimation by JE/Engr-in-charge.And ensure that the fault and rectified within 12 hrs to 48 hrs failing which as amount of Rs 200 per Hrs will be recovered as panel recovery from any payment due to the contractor after expiry 70 Hrs.
Hirachand Sunderji and co (BID ID -3476629)
jagdish machinery stores (BID ID -3476556)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.19 MB
BOQ_825268.xls
BOQ • 0.31 MB
Tenderpages8901.pdf
Tender Documents • 0.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .