Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.3 LAccepted-AOC HOSUE NO 202 NEW RAM VIHAR COLONY PINTO PARK MORAR GWALIOR 474005 MP | GWALIOR | MADHYA PRADESH | 474005 | L1 | Accepted-AOC Lowest quoted bidder. | |
| 2 | L2₹38.5 L+₹19,645 (0.51%)Rejected-Finance 24 824 GOVERDHAN COLONY MAIN BHIND ROAD GOLE KA MANDIR | L2 | Rejected-Finance Higher quoted bidder. | |
| 3 | L3₹38.9 L+₹64,141 (1.68%)Rejected-Finance C 40 BHAGAT SINGH NAGAR BHIND ROAD GWALIOR MP 474005 | NA | NA | 474005 | L3 | Rejected-Finance Higher quoted bidder. | |
| 4 | L4₹39.2 L+₹95,330 (2.49%)Rejected-Finance 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L4 | Rejected-Finance Higher quoted bidder. | |
| 5 | L5₹39.4 L+₹1.1 L (2.87%)Rejected-Finance | L5 | Rejected-Finance Higher quoted bidder. |
| Sl No | Description | Qty | Unit | anand enterprises L2 | NOORI ELECTRIC ENGINEERING WORKS L7 | SK Traders Sons L6 | SHRI HARI CONSTRUCTION L3 | KP ELECTRICAL AND AUTOMATION L1 | TIRUMALA CONSTRUCTION L5 | SHAHJEE FRIDGE SERVICE L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| .05DESCRIPTION OF ITEMS | ||||||||||
| 1.00 | Taking down carefully storage water heater of capacity 25 to 50 ltr, dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound, overhauling complete to ensure free & consistent flow of water through pipe outlet, bronze welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at existing/new place, testing/commissioning after re-installation at site complete all as specified & directed.
Note:-The defective parts shell be mesured and paid in relevant items saperately. | 170 | Each Job | 220 ₹37,400 Lowest | 280 ₹47,600 | 250 ₹42,500 | 225 ₹38,250 | 250 ₹42,500 | 230 ₹39,100 | 300 ₹51,000 |
| 2.00 | M&L for painting on external surface with one coat of white synthetic enamel paint after filling cavities with filler, incl writing MES No in front side of outer surface of geyser in sign writing with black colour to storage water heater (Geyser) complete all as specified and directed. | 40 | Each Job | 180 ₹7,200 Lowest | 220 ₹8,800 | 210 ₹8,400 | 185 ₹7,400 | 220 ₹8,800 | 190 ₹7,600 | 224 ₹8,960 |
| 3.00Supply only the following parts for geysers 50/25/35 Ltrs capacity of make Bajaj / Racold / Power pack/ Venus or equivalent ISI marked (Make of parts shall be as per make of Geysers) :- | ||||||||||
| 4.00 | Supply only Heating element 2 KW suitable for operation on 230V AC 50Hz | 65 | Each | 320 ₹20,800 | 580 ₹37,700 | 380 ₹24,700 | 325 ₹21,125 | 300 ₹19,500 Lowest | 330 ₹21,450 | 311 ₹20,215 |
| 5.00 | Supply only Heating element 1.5KW suitable for operation on 230V AC 50Hz | 50 | Each | 210 ₹10,500 Lowest | 520 ₹26,000 | 270 ₹13,500 | 220 ₹11,000 | 250 ₹12,500 | 230 ₹11,500 | 252 ₹12,600 |
| 6.00 | Supply only Thermostat fitting fitment varying capactiy for 25/35/50 Ltrs capacity Geyser. | 120 | Each | 130 ₹15,600 Lowest | 180 ₹21,600 | 145 ₹17,400 | 140 ₹16,800 | 160 ₹19,200 | 145 ₹17,400 | 162 ₹19,440 |
| 7.00 | Welding / brazing of copper tank for arresting leakages etc for 25/35/50 Ltrs capacity geysers | 20 | Job | 440 ₹8,800 | 200 ₹4,000 Lowest | 470 ₹9,400 | 450 ₹9,000 | 400 ₹8,000 | 455 ₹9,100 | 410 ₹8,200 |
| 8.00 | Supply only release valve Make : Ditz/Venus/Usha /Recold/Bajaj. | 10 | Each | 210 ₹2,100 | 200 ₹2,000 Lowest | 230 ₹2,300 | 220 ₹2,200 | 230 ₹2,300 | 225 ₹2,250 | 232 ₹2,320 |
| 9.00 | Supply only PVC connection hot and cold type of 15 mm size with brass nut coppling in both end of length 300 mm for geyser | 80 | Each | 140 ₹11,200 | 120 ₹9,600 Lowest | 180 ₹14,400 | 145 ₹11,600 | 180 ₹14,400 | 145 ₹11,600 | 183 ₹14,640 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
24 Jun 2025, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
REPAIR / REP / OVERHAULING OF HOT / COLD WEATHER APPLIANCES AND CONNECTED WORKS AT MIL STN CHAMPAWAT AND OTHER AREA UNDER GE MES PITHORAGARH.
2025_MES_710545_1
8672/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Pithoragarh
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹80,000
Yes
12 Aug 2025
27 May 2025
27 Jun 2025
27 May 2025
24 Jun 2025
10 Jun 2025
28 May 2025 - 5 Jun 2025
Amount
DESCRIPTION OF ITEMS
Taking down carefully storage water heater of capacity 25 to 50 ltr, dismantling inner tank & outer tank, pipe assembly, cleaning thoroughly with descaling liquid compound, overhauling complete to ensure free & consistent flow of water through pipe outlet, bronze welding of inner tank if required at site, rethreading of inlet/outlet pipe 15mm dia, reassembling the same at existing/new place, testing/commissioning after re-installation at site complete all as specified & directed. Note:-The defective parts shell be mesured and paid in relevant items saperately.
M&L for painting on external surface with one coat of white synthetic enamel paint after filling cavities with filler, incl writing MES No in front side of outer surface of geyser in sign writing with black colour to storage water heater (Geyser) complete all as specified and directed.
Supply only the following parts for geysers 50/25/35 Ltrs capacity of make Bajaj / Racold / Power pack/ Venus or equivalent ISI marked (Make of parts shall be as per make of Geysers) :-
Supply only Heating element 2 KW suitable for operation on 230V AC 50Hz
Supply only Heating element 1.5KW suitable for operation on 230V AC 50Hz
Supply only Thermostat fitting fitment varying capactiy for 25/35/50 Ltrs capacity Geyser.
Welding / brazing of copper tank for arresting leakages etc for 25/35/50 Ltrs capacity geysers
Supply only release valve Make : Ditz/Venus/Usha /Recold/Bajaj.
Supply only PVC connection hot and cold type of 15 mm size with brass nut coppling in both end of length 300 mm for geyser
Supply only PVC connection hot and cold type of 15 mm size with brass nut coppling in both end of length 450 mm for geyser
Supply only new appratus plate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 25/35 ltr capacity and all as specified and directed.
Supply only new appratus plate complete with nuts, bolts, washers, rubber gasket so as to make it leak proof complete 50 ltr capacity and all as specified and directed.
Supply only insulating material of glass wool for storage type water heater (geyser) any make and size 25 to 50 ltr capacity
Supply only neon lamp indicator square/round type for storage type water heater of any capacity all as specified.
Supply only rubber gasket of appratus plate assy of storage water heater and S&F new rubber gasket suitable for 25/35/50 ltrs capacity storage water heater, complete all as specified and directed.
S&F in repair stop cock 15mm dia chromium plated screwed down screwed for iron pipe or for brass ferrule all as specified.
S&F in replacement industrial plug top, 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts all as specified.
S&F in repair socket 3 pin industrial type 3 pin (2 pin & earth) suitable for sheet metal plug & socket 16/20 Amps, 240 volts all as specified.
Taking down existing unserviceable MCB single pole of any capacity from sheet metal enclosure and S&F new MCB single pole, 6-32 Amp, complete all as specified and directed.
Taking down burnt finned strip heater from winter heating plant of MH & S&F new finned strip heater of capacity 3.0 KW complete all as specified. Make-DASPASS
All as per item No. 20 above but 2.0 KW.
Disconnecting, dismantling winter heating plant of capacity 38 KW (AHU capacity 4600 CFM) installed in OT/ICU of 161 MH for complete overhauling / servicing and refitting in same position after reassembling including replacement of minor repairsComplete all as specified and directed by Engineer-in- Charge
All as per item No. 22 above but winter heating plant of 10KW (AHU capacity 1400 CFM) installed in labor room of family ward, complete all as specified and directed by Engineer-in- Charge
Taking out worn out ‘V’ shape fan belt from blower assembly of winter heating plant of OT & labour room and S&F new fan belt of same size, complete all as specified and directed.
Taking down unserviceable heating element of any capacity from winter heating plant and replacing the same with new heating rod including commissioning and testing complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 32 Amp 415 V with 230 V coil complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 40 Amp 415 V with 230 V coil complete all as specified and directed.
S&F in repairs and connect 3 Phase contactor 63 Amp 415 V with 230 V coil complete all as specified and directed.
Taking out existing unserviceable voltmeter from winter heating plant control board and S&F new volt meter 0-500 volts of size 96mm x96mm including connecting and testing complete all as specified and directed.
Taking down unserviceable ball bearing from blower fan assembly of winter heating plant of 10KW & S&F new ball bearing of existing size complete all as specified and directed.
S & F in repair ball bearing of blower fan in existing winter heating plant of capacity 38 W all as specified and directed.
Repair of EPU of shadow less light fitting, checking & replacing defective parts in electronic printed circuit board, checking & repairing of auto control circuit complete including & testing & replacement of burnt damaged relay etc complete all as directed.
S&F in repair voltage stabilizer with input voltage 110 volts to 290 volts and output 230 voltage with 50 Hz,of capacity 4 KVA suitable for refrigerator / AC incl taking down old voltage stabilizer complete all as specified.
Repair of voltage stabilizer 0.5 /1.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed.
Repair of voltage stabilizer 3.0/4.0 KVA automatic boost & buck type, checking & replacing burnt parts in electronic printed circuit board, checking & repairing of auto control circuit complete including calibration & testing & replacement of burnt damaged relay etc complete all as directed.
Repair to voltage stabilizer 5.0 KVA by replacing worn out / burnt parts in electronic printed circuit, board, checking and repairing of automatic control circuit, replacement of damaged / burnt relay/transformer etc & calibrating the same complete all as specified and directed.
S&F time delay relay for voltage stabilizer 5 KVA (As per sample) including taking down old defective relay all as directed.
S&F time delay relay for voltage stabilizer 3 KVA / 4 KVA (As per sample) including taking down old defective relay all as directed.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA complete all as specified and directed. Note: Old US Appliances will be deposited to AGE EM Store yard
Checking of fault in Electric wiring of New accn area by deputing adequate number of qualified electrician and helper with necessary T&P and safety tools etc and ensure that to restore electricity after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill), replacement of electrical accessories, if reqd are measured and paid separetely in relevant items: Note:- (a) The electrical items reqd to repair fault are measured and paid separately in relevant items. (b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaints per day. (c) Electrician will take the complaint slip from JE EM and the same will be deposited to JE EM duly signed by Users after completing the job for making payments.
Checking of fault in Solar water Heater of New accn area by deputing adequate number of qualified Solar technician/Plumber and helper with necessary T&P and safety tools etc and ensure that to restore water heater in working condition after rectifying the fault with using minor items of cost not more than Rs. 10/- shall be included in the unit rate complete all as specified (complaint shall be part of the bill), replacement of connected accessories if reqd are measured and paid separetely in relevant items: Note:- (a) The Solar water heater items reqd to repair fault are measured and paid separetely in relevant items. (b)The fault shall be attended within one day, otherwise recovery will be charged Rs. 50/- per complaints per day. (c) Solar technician/Plumber will take the complaint slip from JE EM and the same will be depositing to JE EM duly signed by Users after completing the job for making payments.
Supply only Flat plate collector of rectangular type as per exixting at site
Supply only Hot water tank SS 304 ex model cap100 Ltr with heat exchanger
Supply only Hot water tank SS 304 ex model cap 200 Ltr with heat exchanger
Supply only Hose pipe including clamp as per existing at site 2 KW
Supply only Heating element 2 KW,ISI Marked
Supply only Heating element 3 KW,ISI Marked
Supply only Thermostat for solar water heater 100/200 Ltr ,ISI Marked
Supply only EIS-DA (descaling chemical for all type metal) as complete
Supply only Toughened Glass for solar plate of solar water heater of capacity 100/200 Ltr
Supply only Makeup tank for solar water heater 100/200 Ltr
Supply only NRV of makeup tank for solar water heater 100/200 Ltr
Supply only Elbow 15mm GI, ISI Marked.
Supply only Elbow 20mm GI, ISI Marked.
Supply only Elbow 25mm GI, ISI Marked.
Supply only Tee 15mm GI, ISI Marked.
Supply only Tee 20mm GI, ISI Marked.
Supply only Tee 25mm GI, ISI Marked.
Supply only Socket 15 mm GI, ISI Marked.
Supply only Socket 20 mm GI, ISI Marked.
Supply only Socket 25 mm GI, ISI Marked.
Supply only Union 15 mm GI, ISI Marked.
Supply only Union 20 mm GI, ISI Marked.
Supply only Union 25 mm GI, ISI Marked.
Supply only Reducer elbow 20 mm GI, ISI Marked.
Supply only Reducer elbow 25 mm GI, ISI Marked.
Supply only Reducer Tee 20 mm GI, ISI Marked.
Supply only Reducer Tee 25 mm GI, ISI Marked.
Supply only Reducer Socket 20 mm GI, ISI Marked.
Supply only Reducer Socket 25 mm GI, ISI Marked.
Supply only Hex nipple 15 mm GI, ISI Marked.
Supply only Hex nipple 20 mm GI, ISI Marked.
Supply only Hex nipple 25 mm GI, ISI Marked.
Supply only Tank nipple 15 mm GI, ISI Marked.
Supply only Tank nipple 20 mm GI, ISI Marked.
Supply only Tank nipple 25 mm GI, ISI Marked.
Supply only Plug 15 mm GI, ISI Marked.
Supply only Plug 20 mm GI, ISI Marked.
Supply only Plug 25 mm GI, ISI Marked.
Supply only Nipple 15 mm GI,ISI Marked.
Supply only Nipple 20 mm GI,ISI Marked.
Supply only Nipple 25 mm GI, ISI Marked.
Supply only Ball valve 15 mm GI, ISI Marked.
Supply only Ball valve 20 mm GI, ISI Marked.
Supply only Ball valve 25 mm GI, ISI Marked.
Supply only Gate valve 20 mm, ISI marked all as speficied and directed
Supply only Gate valve grade 25 mm, ISI marked all as speficied and directed
Supply only GI pipe medium grade 25 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thickness all as speficied and directed.
Supply only GI pipe medium grade 15 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thickness all as speficied and directed.
Supply only GI pipe medium grade 20 mm, ISI marked wrapping of glass wool insulation incl aluminium cladding of 1 mm thickness all as speficied and directed.
Supply only flexible hose pipe 20 mm as per sample
Supply only clamps as per sample
Supply only gasket as per sample
Supply only of M-Seal
Supply only float valve 20 mm
Supply only Tank lid 200 ltrs
Supply only Tank lid 500 ltrs
M&L for opening of solar plate & repairing of leakage copper pipe with complete gas welding/soldering as required on complete copper tubing in solar water heater and after completion of job reassembling the same complete all as specified and directed
Dismantling exisiting solar water heater 100/200Ltr and descaling the pipe by means of descaling agent the same reassembling after comletion the work Note : Descaling agent shall be paid and measured separately
M&L for painting of solar water heater of old MS stand with monkey cage of tank duly painted of one coat of Black enemaled paint complete all as specified and directed.
Cleaning of overhead tank 200 Ltr by cleaning brush complete draining of old water and checking no float valve broken or no leakage found after cleaning of OH tank
S&F in replacement of Rotational moulded polyethylene water storage three layers tanks (cylindrical vertical with closed top) hoisted and fixed in position of capacity 200 Ltrs all as specified and directed by Engr-in-Charge
M&L for opening of MS stand/cage of services tank welding of stand with replacement of hinge at required position complete all as specified and directed.
Dismantling of existing solar water heater 100/200 Ltr and welding /brazing of leakage tank at any position complete all as specified and directed.
M & L Flushing the complete condensing unit of AC refrigirator and dep freezer, evaportar jointing and the compressor suction and delivery and search out leakage and rectify by means of breazing. and delivery tubes and replacement the charging lines. Strainers capillary tube etc rectification of the leakage from the system vaccumising dehydrating oil including testing and commissioning of system complete all as specified and directed.
S&F in repair of condensing unit and housing the unit of any make of the window type AC.
Supply & charging refrigerant gas R-134(a) suitable for envirement friendly charging line on sealed unit of compressor of window type room AC 1.5/2.0 ton including crimping and resoldring to charging line, complete all as specified and directed.
Removing the unserviceable compressor unit from the window/split type room AC 1.5 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 1.5 ton and all as specified and all as directed by Engineer-in-Charge.
Removing the unserviceable compressor unit from the window/split type room AC 2.0 ton and supply and fix new hermetically sealed compressor unit, Make : Kirloskar/Shriram suitable to operate in AC single phase 50 HZ 230 Volts suitable for window type AC 2.0 ton and all as specified and all as directed by Engineer-in-Charge.
Supply and fix repair PCB for the 1.5 to 2.0 ton capacity A/C as directed by Engineer-in-Charge.
Supply and fix repair Evaporator coil for the 1.5 to 2.0 ton capacity A/C as directed by Engineer-in-Charge.
Supply and fix repair Front grill for the 1.5 to 2.0 ton capacity A/C conditioners as directed by Engineer-in-Charge.
Supply and fix in repair Starting relay for the 1.5 to 2.0 ton capacity A/C conditioners as directed by Engineer-in-Charge.
Supply and fix repair Starting capacitor 80-100 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC. Make:Keltron
Supply and fix Running capacitor 36 mfd for the 1.5 to 2.0 ton capacity A/C conditioners of any make of AC. Make:Keltron
Supply only Compressor mounting rubber bush (set of 3 Nos counted as one unit)
S&F repair blower fan motor for split unit AC 1.5 ton to 2.0 ton (As per sample) incl taking down fan motor complete all as specified.
S&F repair condenser Fan blade rings 1.5 to 2.0 ton (As per sample) incl taking down old blower complete all as specified.
Taking down unserviceable copper tube from window type AC 1.5 ton to 2.0 ton supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed.
S&F repair thermostat unit including electronic relay eqpt and electronic plate for air conditioner incl taking down old thermostat complete all as specified and directed.
Disconnecting of unserviceable three core flexible cord from window type AC/Refrigerator/storage water heater / voltage stabilizers of any size, supply and S & F connect three core flexible cored of size 2.5 sq complete all as specified and directed
Cutting suction and discharge gas pipe line and taking out unsv compressor unit from refrigerator of 165/180 ltrs capacity and S&F new sealed compressor unit of same model or approved model of same capacity complete incl commissioning and testing after installation at site complete all as specified and directed.
All as item No. 122 above but refrigerator of capacity 210/310/320 ltrs
S&F in repair of cooling coil and housing of the refrigirater unit of any make.( 280 ltr to 310 ltr)
S&F relay for refrigerator including taking down old relay complete all as specified.
S&F thermostat unit for refrigerator including taking down old thermostat complete all as specified.
S&F pigmy lamp pin/thread type 15 watts 230 volts suitable for refrigerator incl removing old bulb/lamp, complete all as specified and directed.
S&F door gasket for refrigerator (as per sample) incl taking down old door gasket & aligning door after opening from body incl inserting packing, welding, threading etc which so ever required to leave no air gap between door & body and top edge of refrigerator flushing with top surface of refrigerator of capacity 165/175 ltrs.
All as item No. 128 above but for refrigerator of capacity 280/286/310 or 320 ltrs capacity.
Taking out unserviceable lock from the refrigerator and S&F new lock with keys, complete all as specified and directed.
Dismantling unserviceble freezer defrosting fan from double door refrigerator and replaced with new freezer defrosting fan of same model/capacity 200 to 300ltr, complete all as specified and directed
M & L for replacement of unserviceble/damage freezer cooling coil assembly complete of existing model of refrigerator 165/175 ltrs capacity all as directed
All as item No 132 above but refrigerator of 280/310/320 ltrs
Taking down unserviceable copper tube from any capacity of Refrigerator, supply & joint new copper tube for charging refrigerant gas in machine complete all as specified and directed.
Supply & charging refrigerant gas R-134(a) charging line on sealed unit of compressor of refrigerator 165/175 LTRS16including crimping and resoldring to charging line, complete all as specified and directed.
All as per item No. 135 above but 280/310/320 ltrs R-134(a) non CFC refrigerant gas complete all as specified and directed
Taking down unserviceable capillary from any capacity of Refrigerator, supply & joint new capillary for charging refrigerant gas in machine complete all as specified and directed.
Taking down old unserviceable liquid filter/drier from all capacity of Refrigerator, Supply & joint new liquid filter/drier for charging refrigerant gas in machine complete all as specified and directed.
Disconnecting / taking down carefully ceiling fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable of size 23/.0076 complete testing & specified all as directed.
Disconnecting / taking down carefully exhaust fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable of exhaust fan 450 mm sweep complete all as directed.
Ditto all as per item No. 140 above but exhaust fan 380/300 mm sweep
Ditto all as per item No. 140 above but exhaust fan 250/225 mm sweep
Rewinding of ceiling/exhaust/wall mounted/cabin/table fan with super enameled copper winding wire of suitable size and providing with suitable insulation to fan including replacement of wornout nut, bolt, washers, split pin etc., re assembling and testing on completion complete all as specified and directed for the following type of fans.
Ditto all as per item No 143 Exhaust fan of any Make 300/250 mm sweep
Ditto all as per item No 143 Exhaust fan of any Make 450/380 mm sweep
Ditto all as per item No 143 Cabin fan/wall fan/table fan/pedestal fan 400 mm sweep.
Supply only following components of fan in replacement of unserviceable item as per item no-140 & 143 all as directed by Engineer-in-Charge
Ball bearing of suitable size for Exhaust fan of any size and sweep.
capacitor 2.5 mfd , ± 5%, 440V, AC, 50 Hz after removing old/defective condenser complete all as specified an directed.
MS Clamps with nut bolts and washers for hanging of ceiling fan of any size.
bush for ceiling fan after taking out old dry/damaged bush complete all as specified & directed.
ball bearing for ceiling fan (As per sample) after removing old damaged ball bearing complete all as specified and directed.
S&F blade in repair assembly suitable for exhaust fan 300 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
S&F blade in repair assembly suitable for exhaust fan 250/225 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
S&F blade in repair assembly suitable for exhaust fan 450 mm sweep including taking down old unserviceable blade assembly from exhaust fan, complete all as specified and directed.
M&L for painting with one coat of paint with grey enameled paint on external surface of exhaust fan of any size, including frame and louvers and writing MES NO. on outer surface of motor with black enamel synthetic paint complete all as specified and directed
Disconnecting / taking down carefully BLDC ceiling fan from existing position, dismantling, overhauling & cleaning thoroughly, oiling greasing and rehanging after replacing, split pins, check nuts, rubber reel etc and reassembling duly connected with new PVC 3 core flexible copper conductor cable of size 23/.0076 complete testing & specified all as directed. Make :-Orient or its equivalent. Note:-The Ceiling fan items reqd to repair fault are measured and paid separately in relevant items.
(a) copper coil with shaft
(b) bearing as per existing
(a) BLDC PCB Board
(a) PCB Board plastic box
Supply install and tesing water heater storage type (Geyser) single phase 230 V, 50 Hz, 5 star energy saving high density PUF insulation tank made of heavy duty mangesium anode rod with steel core to protect enamelled tank from rust & corrosion, vertical installation type 25 Ltr Cap 2000 Watt rated power, incoloy 800 glass coated heating element, inner tank coating of feroglas powder, tank made of ultra thick super cold rolled steel plates, rated pressure 0.8 MPa, IPX4 protection consist of safety valves, thermal cut off, thermostat including connecting up and fixing arrangement on wall including providing hole fastners-04 Nos hot and cold water metallic flexible pipes 15 mm bore of adequate length as provided by OEM or required at site - 02 Nos non return valve 01 No and including necessary plumbing work, complete with intergated shock safe plug with all protection features as per OEM design and standard all as specified and directed.
S & F Exhaust Fan PVC body, 250mm(10") sweep, single phase, 230 volts 50 Hz AC,1400 RPM, energy saving, heavy duty totally enclosed, heavy duty motor with die-cast aluminiun rotor mounted on two ball bearings complete with louvers and shutters including cutting hole for fixing exhaust fan to wall and making good the disturbed surfaces (including making holes in wall,plastering, necessary brickwork and distempering) to match with the existing specification, connecting electrically using 3 core 0.75 Sq mm PVC insulated flexible copper conductor cable over all sheathed all as required at site and as directed.
Material & Labour in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x4 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 4 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.
Material & Labour in repair for sub main wiring with 1100 volts grade PVC insulated and unsheathed cable with stranded copper conductor 2x6 Sqmm, of code Red for Phase,Black For Neutral & Green For Earth concealed in wall and drawn including PVC conduit along with 6 Sqmm single core copper conductor multi stranded cable as earth continuity conductor complete all as specified and as directed.
S&F in repair Electronic fan regulator flush type,switch size Step type, 230 volts ISI marked complete all as specified and directed.
S&F in replacement of LED Bulb 9 watt,6500K complete all as specified and directed.
Ditto as per item 167 above but of capacity 12 watt,
Ditto as per item 167 above but of capacity 15 watt,
S&F in replacement of inverter LED Bulb 9 watt, complete all as specified and directed.
Ditto as per item 170 above but of capacity 12 watt,
Ditto as per item 170 above but of capacity 15 watt,
Supply and Fix in repair of 1x20 watt LED security light fitting , pressure die-cast aluminium including fixing the same of GI pipe 25 mm dia bore light grade bracket, 1.5 mtr long including necessary cutting / bending /welding and fixed the same with two Nos FI clamps of 40x 4mm duly painted and suitable size of nut & bolts etc. and making electric connection with two core copper flexible wire of 0.50 Sqmm complete and including taking down old fitting all as specified and directed.
Ditto as per item 173 above but of capacity 35 watt,
Ditto as per item 173 above but of capacity 45 watt,
Ditto as per item 173 above but of capacity 60 watt,
S&F in replacement of New generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Clear Cover offers bright illumination for different applications of 45 watt,6500K LED fittings, prewired with fixing arrangement complete all as specified and directed.
Ditto as per item 177 above but of capacity 45 watt,4000K.
S&F in repair round surcace mounting LED panel with luminaire 3W, 6500K with aluminum housing plastic diffuser complete including taking down old fitting all as specified and directed.
S&F in repair round surcace mounting LED panel with luminaire 6/8 W, 6500K with aluminum housing plastic diffuser complete including taking down old fitting all as specified and directed.
Supply and Fixing in repair Decorative wall Light fixture made up of polycarbonate, suitable for retrofit LED 9 W (spiral B-22 Base) complete all as specified and directed.
S&F in repair recess mounting LED 2x2 luminaire 36W, slim ceiling light with extruded aluminium housing and milky diffuser complete and including taking down old fitting all as specified and directed.
Supply and fix in repair of LED Integrated Batten T5 box type surface mouted, 18/20 W prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
Supply and fix in repair of LED Integrated Batten T5 box type surface mouted, 9/10 W prewired including electric electrical connection with PVC insulated twin twisted copper wire of size 0.75 Sqmm from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.50 m deep below normal ground level, connected to galvanized earth lead wire 4.0mm dia by means of bolts, nuts and washers of galvanised iron or steel all as shown in earth plate No 5 of MES schedule 1991 part – I connected to earthing test point including earth continuity conductor and loop earthing etc. as required 4 mm dia galvanized iron or steel wire including necessary excavation and earth work, concrete pit & chamber in PCC 1:2:4 type B1 & pit cover 75mm thck in RCC 1:2:4 type B1 dully reinforced with 6mm dia bar @ 150 c/c both ways including with lifting handle and Earth lead and GI protection pipe light grade 15 mm dia beyond 7.5 mtr from electrode to earth terminal point /main switch board and 20mm bore GI watering pipe medium grade etc. complete all as specified and directed.
M&L in replacement of Vertical type TPN DB, 4 Way, as per IS-8623, IP-42 protection, universal mounting with 100A copper bus bar with neutral bar, earth bar and cable ties for cable management, top and bottom removable gland plate suitable for MCCB 125 Amps TPN as incomer and MCB TP as outgoing, with and including providing following MCCB/MCBs & making necessary electrical connection for incoming & outgoing cables, with copper lugs, crimped with crimping tool :-a) Incoming:- MCCB, TPN, 415 Volts,125 Amp ultimate breaking capacity (lcu)-25 KA, confirm to IEC-60947-2-01 No (b) Out going MCBs:- MCB TP 415 volts 63 Amps having repturing capacity 10 kA, 'C' curve type-4 Nos
Supply and fix in repair Single pole and neutral enclosure with a two pin and earth plug and socket complete with onesingle pole MCB of 20 amp including taking down all as specified and directed.
Supply and Fix in repair MCCB, 4 pole, 415 volts, 100 amps, of 16 KA complete all as specified and directed.
Supply and Fix in repair MCCB, 4 pole, 415 volts, 125 amps, of 16 KA complete all as specified and directed.
Supply and Fix in repair MCCB, 4 pole, 415 volts, 200 amps, of 16 KA complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 93,725.40 will be deducted from the total amount arrived, at the time of Acceptance of contract.
anand enterprises (BID ID -3326046)
SHRI HARI CONSTRUCTION (BID ID -3326417)
SHAHJEE FRIDGE SERVICE (BID ID -3326384)
TIRUMALA CONSTRUCTION (BID ID -3326454)
SK Traders Sons (BID ID -3326333)
NOORI ELECTRIC ENGINEERING WORKS (BID ID -3326265)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .