Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.2 LAdmitted-Finance | L1 | Admitted-Finance | ||
| 2 | L2₹1.2 L+₹2,757.47 (2.36%)Admitted-Finance VILL MOHISGOTE DHALIPARA P O KRISHNAPUR KOLKATA 700102 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700102 | L2 | Admitted-Finance | ||
| 3 | L3₹1.2 L+₹3,237.03 (2.77%)Admitted-Finance | L3 | Admitted-Finance | ||
| 4 | Rejected-Technical | - | Rejected-Technical Documents not satisfactory. | ||
| 5 | Rejected-Technical B GANGARAMPUR ULUBERIA HOWRAH 711316 | ULUBERIA | HOWRAH | WEST BENGAL | 711316 | - | Rejected-Technical Documents not satisfactory. |
Tender Value
₹1.2 L
EMD Value
₹2,398
Closing Date
28 Nov 2025, 12:00 pmClosed
Executive Engineer
BIDHANNAGAR MUNICIPAL CORPORATION
Supply and fixing of Steel tubular pole with LED fittings from Kochuri goli to Aminia Restaurant at Jhawtala within ward no-12 under BMC. (Booth no-68, Scheme ID- APAS/01/115/68/0002)
2025_MAD_940397_28
NIT NO. 1135/PWD(BMC), DTD. 06.11.2025
Open Tender
Miscellaneous Works
Percentage
30 days
Bidhannagar Municipal Corporation
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹2,398
30 Mar 2026
7 Nov 2025
1 Dec 2025
7 Nov 2025
28 Nov 2025
7 Nov 2025
Supplying swaged and welded steel tubular pole of following specifications as per IS 2317: 1980 7 Mtr. Length, 62Kg, 410-SP-01
S/F arm bracket of 50 mm bore tubular Pipe (M.S.) of 1.5 m (5’) length for fixing on 75/100 mm pole top including S/F 4 mm thick M.S. plate welded with bolts, nuts & clamps,etc. as required with fabrication work.
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling upthe excavated earth pit with shifted soil and ramming properly
Supply and fixing of special head type loop in box (3mm thick) with terminal block & gland plate and other accessories fixed on the top of the pole as required for 3 phase 4 wire connections.
Earthing the steel tubilar pole with 19 mm dia x2.5 mtr. Length G.I rod & 1no. 4 SWG G.I wire up to 4mtr. Length 15 mm dia x 65 long G.I bolt, double nuts & washer including supply of all meterials as per direction of E.I.C.
Supply and fixing of Green line V2 street light (115 Watt) complite with all accessories to be fixed / project from the wall of the building or on pole incl making hole / providing cka mping arrengement and necy GI reducer as required S & F 40 mm Dia GI pipe (ISI Medium ) quality 1.5 Mtr. Average length of 1.5 sqmm PVC insulated single core standerd annealed copper wire and making connection as required and mandling good damages to wall including paintings etc. make-Bajaj, Philips, Havells .
Wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 19 mm heavy gauge Polythene Pipe incl. necy fittings as required. a) 2 x 22/0.3 (1.5sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
Supply of 1.1 KV grade 4 core 10 sqmm XLPE insulated and PVC sheathed Al conductor unarmoured cable as per IS 7098 (Part-I) 1988 with upto date amendments. Make Gloster/Nicco/Havels/Polycab or equivalent.
S & F of 'D' iron clamp fabricated from 25 mm x 6 mm MS flat duly galvanized incl. necessary shackle insulator (3'x3') hexagonal galvanized bolts, nuts & washers incl. painting complete as per direction of the EIC.
S&D of 5/8 tene screw arrangement at pole clamp for fastening arrangement of catenary.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables 4 Core up to 10 Sq mm
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint. (a) Up to 9 Mtr. Long pole (i) 1st coat of aluminium paint over 1 coat of RO priming.
(ii) 2nd coat of aluminium paint over 1st coat.
Supplying & Erection of mini size feeder pillar box of Size (918 x 561 x 382 mm) made up of 2 mm thick MS Plate along with suitable M.S. Angle. The P.B. have double hinge door at the front & back with suitable locking arrangement. The box will be painted by 2 cores of aluminiam paint over 1 coat of red oxide paint. Suitable arrangement should be provided for fixing of Timer unit, fuse unit & other accessories. Leg of the pillar box will be 900 mm in length by made up of (35 x 35 x 3 mm MS Angle with suitable base Plate. Legs of the Pillar box will be erected at 300 mm below the ground level with cement concrete (6:3:1). Rest portion coverd by 5" Brick Wall with plastering & net cement & bottom portion filled with silver sand as drawing & direction of E.I.C
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below: (a) By ISI-Medium GI pipe.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.89 MB
Tendernotice_2.pdf
PDF • 17.41 MB
BOQ_2231191.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .