Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 2 | Admitted-Fee/PreQual/Technical | Admitted-Fee/PreQual/Technical |
| 3 | Admitted-Fee/PreQual/Technical 111 YADAV ELECRIC MARKET GB MARG LUCKNOW LUCKNOW UTTAR PRADESH 226018 | LUCKNOW | UTTAR PRADESH | 226018 | Admitted-Fee/PreQual/Technical |
| 4 | Admitted-Fee/PreQual/Technical ALIGANJ LUCKNOW 2845 226024 INDIA | LUCKNOW | UTTAR PRADESH | 226024 | Admitted-Fee/PreQual/Technical |
Tender Value
₹36.7 L
EMD Value
₹73,450
Closing Date
12 Sept 2026, 6:00 pmClosed
CWE (AF) BAREILLY
HQ Commander Works Engineers (AF) Military Engineer Services Bareilly 243002
As described in BOQ
2026_MES_749393_2
81614/E8
Open Tender
Civil Works
Item Rate
180 days
AGE (I) (AF) BHOWALI
As per NIT
9 documents required · 9 mandatory
₹500
AGE (I) (AF) BHOWALI
₹73,450
21 Sept 2026
24 Aug 2026
21 Sept 2026
24 Aug 2026
12 Sept 2026
31 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Design , Manufacturing , Supply, Erecting , installation , testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 6 KW (i.e. 6000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit ,cables, including earthing , lightening protection etc, including transportation , insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rates.
Location : MT Hangar | 1 | Each Job | - | - |
| 2 | Design , Manufacturing , Supply,Erecting , installation , testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 5 KW (i.e. 5000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit ,cables, including earthing , lightening protection etc, including transportation, insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : Charging room | 1 | Each Job | - | - |
| 3 | Design, Manufacturing, Supply, Erecting, installation, testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 21 KW (i.e. 21000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit, cables, including earthing , lightening protection etc, including transportation, insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : MT Garage | 1 | Each Job | - | - |
| 4 | Design, Manufacturing, Supply, Erecting, installation, testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 13 KW (i.e. 13000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit, cables, including earthing, lightening protection etc. including transportation, insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : Shed in tech area | 1 | Each Job | - | - |
| 5 | Design , Manufacturing , Supply, Erecting , installation , testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 8 KW (i.e. 8000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit, cables, including earthing , lightening protection etc, including transportation , insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : MT Section | 1 | Each Job | - | - |
| 6 | Design , Manufacturing , Supply, Erecting , installation , testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 7 KW (i.e. 7000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit, cables, including earthing , lightening protection etc, including transportation , insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : Badminton Shed | 1 | Each Job | - | - |
| 7 | Design , Manufacturing , Supply, Erecting , installation , testing & commissioning of Grid connected roof Top Solar PV generation Plant of Capacity 14 KW (i.e. 14000 W) without battery, including components, module cost including all civil & general works, mounting structure, Power conditioning unit, cables, including earthing , lightening protection etc, including transportation , insurance complete all as specified and directed,
Note: The disturbed surface shall be made good on the Roof to avoid any leakage inside the building & the rates for the treatment of disturbed roof surface shall deemed to be included in the quoted rate.
Location : Community hall | 1 | Each Job | - | - |
stage.html
html • 0.02 MB
tech_bid_open.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.88 MB
81614AmendedNIT.pdf
Tender Documents • 0.83 MB
BOQ_880839.xls
BOQ • 0.50 MB
81614Tender24Aug26-.pdf
Tender Documents • 1.88 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .