Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.1 CrAdmitted-Finance | ₹18.1 Cr | L1 | Admitted-Finance |
| 2 | L2₹18.3 Cr+₹23.4 L (1.29%)Admitted-Finance 26 340 4 D1 M S NAGAR NANDYAL KURNOOL 518502 | ₹18.3 Cr+₹23.4 L (1.29%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NJR CONSTRUCTIONS PRIVATE LIMITED L2 | Powersol Infra Services Pvt Ltd L1 |
|---|---|---|---|---|---|
| 1.00Architectural and Structural design activities: | |||||
| 1.10 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) Working Drawings, all floor Plans, all Elevations, Sections through both the directions (X&Y), Door & Window Drawings including window grill drawings, detailed toilet drawings, Staircase drawings with railing details, Reflective ceiling plans/ false ceiling plans, Flooring pattern drawings, signages. c) detailed 3D Views indicating elevational details from all sides of buildings including colour schemes, walk through videos. d) Generation of drawings for all connected building elements & services such as structural, Civil finishes, plumbing, sanitary, Electrical installations, and HVAC e) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction drawings.
For Fire Station (RCC framed structure with only Ground floor) & Drill tower (RCC framed structure with Ground+3 floors). | 1,200 | sqm | 500 ₹6,00,000 Lowest | 750 ₹9,00,000 |
| 1.20 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) Working Drawings. c) Generation of drawings for all connected elements & services such as structural, Civil finishes (if any), Electrical installations. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction drawings.
For Tank farm areas (Chemical Storage area with foundations for tanks and underground sumps. ) | 1,740 | sqm | 500 ₹8,70,000 Lowest | 750 ₹13,05,000 |
| 1.30 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) working Drawings, all Elevations, Sections c) Generation of drawings for all connected elements & services such as structural, Civil finishes (if any), Electrical installations. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less thanA-1) of all Good for Construction drawings.
Vehicle Parking sheds (≈8 no’s of vehicles & 1 no of fire tender) | 480 | sqm | 125 ₹60,000 Lowest | 750 ₹3,60,000 |
| 1.40 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
For Fire Station (RCC framed structure with only Ground floor) & Drill tower (RCC framed structure with Ground+3 floors). | 1,200 | sqm | 500 ₹6,00,000 Lowest | 750 ₹9,00,000 |
| 1.50 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
For Tank farm areas (chemical storage area with foundations for tanks and underground sumps. ) | 1,740 | sqm | 250 ₹4,35,000 Lowest | 750 ₹13,05,000 |
| 1.60 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
Vehicle Parking sheds (≈8 no’s of vehicles & 1 no of fire tender) | 480 | sqm | 125 ₹60,000 Lowest | 750 ₹3,60,000 |
| 1.70Note for Item No.1: Tender drawings are enclosed. Please refer to the Technical Specifications for details regarding inputs to be provided by BARC, support for statutory clearances required, timeline for completion of design activities, duration for issuance of clearances/comments by statutory authorities, mode of measurement, and payment terms, etc. | |||||
| 2.00 | Mobilisation of suitable boring and drilling plant and all other allied equipment like boring rigs and all in-situ tests, equipment necessary to do the work under scope of this contract etc. including all skilled and unskilled personnel required for the work etc. complete and demobilisation of same on completion and removal from site as per the instruction of the Engineer-in-Charge.
Note:
(i) Contractor to mobilise sufficient equipment to the site in order to complete the work within the stipulated time frame. Drilling rigs must be capable of vertical drilling through all kinds of soils and all kinds of soft to basaltic /granite rock etc. all complete as per drawing and as directed by the Engineer-in-Charge.
(ii) Prospective bidders shall visit the work site before quoting the for tender. | 1 | L.S. | 3,00,000 ₹3,00,000 | 1,00,000 ₹1,00,000 Lowest |
| 3.00 | Setting up boring rigs at each location for each borehole location including moves between borehole positions, locating and marking the location on the ground by actual survey, setting up of all field test equipment and bringing all personnel to the location to facilitate geotechnical investigation.
Note:
(i) Any criss-cross or back and forth movement of the rig can take place all as per directions and as directed by the Engineer-in-Charge.
(ii) Location of borehole shall be furnished by the Engineer-in-Charge. | 6 | Nos. | 10,000 ₹60,000 Lowest | 18,000 ₹1,08,000 |
Tender Value
₹15.5 Cr
EMD Value
₹28.3 L
Closing Date
23 Jan 2026, 3:00 pmClosed
Chief Engineer,BARC,Mysuru
Chief Engineer,BARC,P.B NO.1,Yelwal,Mysuru-571130
Design and Construction of Fire Station, Drill Tower, Boiler house, Tank farm areas including internal electrical, HVAC and other associated works at SMFC, BARC, Challakere, Karnataka.
2025_BARC_890411_1
BARC/SMFC/CS/02/2024-25/NIT
Open Tender
Construction Works
Item Rate
730 days
Special Material Facility, BARC, Doddullarthikaval
Please refer NIT and Tender Document
7 documents required · 7 mandatory
₹0
₹28.3 L
BARC, DoddUllarthi Kaval, Challakere, Karnataka
18 Aug 2026
19 Dec 2025
29 Jan 2026
19 Dec 2025
23 Jan 2026
6 Jan 2026
19 Dec 2025 - 1 Jan 2026
2 Jan 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Architectural and Structural design activities: | |||||
| 1.1 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) Working Drawings, all floor Plans, all Elevations, Sections through both the directions (X&Y), Door & Window Drawings including window grill drawings, detailed toilet drawings, Staircase drawings with railing details, Reflective ceiling plans/ false ceiling plans, Flooring pattern drawings, signages. c) detailed 3D Views indicating elevational details from all sides of buildings including colour schemes, walk through videos. d) Generation of drawings for all connected building elements & services such as structural, Civil finishes, plumbing, sanitary, Electrical installations, and HVAC e) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction drawings.
For Fire Station (RCC framed structure with only Ground floor) & Drill tower (RCC framed structure with Ground+3 floors). | 1,200 | sqm | - | - |
| 1.2 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) Working Drawings. c) Generation of drawings for all connected elements & services such as structural, Civil finishes (if any), Electrical installations. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction drawings.
For Tank farm areas (Chemical Storage area with foundations for tanks and underground sumps. ) | 1,740 | sqm | - | - |
| 1.3 | Architectural designs and development of detailed drawings consisting of the following: a) development of detailed Architectural drawings, b) working Drawings, all Elevations, Sections c) Generation of drawings for all connected elements & services such as structural, Civil finishes (if any), Electrical installations. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to architectural aspects, along with documentation work and the supply of six sets (sizes not less thanA-1) of all Good for Construction drawings.
Vehicle Parking sheds (≈8 no’s of vehicles & 1 no of fire tender) | 480 | sqm | - | - |
| 1.4 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
For Fire Station (RCC framed structure with only Ground floor) & Drill tower (RCC framed structure with Ground+3 floors). | 1,200 | sqm | - | - |
| 1.5 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
For Tank farm areas (chemical storage area with foundations for tanks and underground sumps. ) | 1,740 | sqm | - | - |
| 1.6 | Structural Analysis & Design consisting of the following: a) Detailed Structural Analysis & Design including seismic analysis b) Preparation of detailed structural & Fabrication drawings. c) Obtaining approval for all the analysis & designs documents, drawings from any IIT/ NIT/ IISC/Approved Govt. Engg. College. All the documents/ drawing shall be signed by a person not below the rank of a professor. d) Support in obtaining all necessary statutory clearances from BARC authorities for construction clearance related to structural aspects, along with documentation work and the supply of six sets (sizes not less than A-1) of all Good for Construction structural drawings.
Vehicle Parking sheds (≈8 no’s of vehicles & 1 no of fire tender) | 480 | sqm | - | - |
| 2 | Mobilisation of suitable boring and drilling plant and all other allied equipment like boring rigs and all in-situ tests, equipment necessary to do the work under scope of this contract etc. including all skilled and unskilled personnel required for the work etc. complete and demobilisation of same on completion and removal from site as per the instruction of the Engineer-in-Charge.
Note:
(i) Contractor to mobilise sufficient equipment to the site in order to complete the work within the stipulated time frame. Drilling rigs must be capable of vertical drilling through all kinds of soils and all kinds of soft to basaltic /granite rock etc. all complete as per drawing and as directed by the Engineer-in-Charge.
(ii) Prospective bidders shall visit the work site before quoting the for tender. | 1 | L.S. | - | - |
| 3 | Setting up boring rigs at each location for each borehole location including moves between borehole positions, locating and marking the location on the ground by actual survey, setting up of all field test equipment and bringing all personnel to the location to facilitate geotechnical investigation.
Note:
(i) Any criss-cross or back and forth movement of the rig can take place all as per directions and as directed by the Engineer-in-Charge.
(ii) Location of borehole shall be furnished by the Engineer-in-Charge. | 6 | Nos. | - | - |
| 4Boring vertically through all kinds of soils for the following depths, weathered rock and soft rock, boulders met during drilling with suitable and adequate equipment of diameter 150 mm or more as required for depths as measured below existing ground level at rig location inclusive of casing pipes, wherever necessary, conducting Standard Penetration Test (SPT) including collection and logging of samples, placing them in approved wooden core boxes coated with a coat of anti-termite chemical in a proper sequence, numbering each sample, noting the lithology and transporting the boxes to core store etc., all complete as per direction of the Engineer-in-Charge. Note: (i) Rate of this item shall include conducting SPT at regular interval of 1.0m to 1.5m & where there is change in sub-surface profile and collecting, packaging and labelling disturbed samples therefrom. (ii) Rate also includes the cost of wooden core boxes. (iii) Depth will be measured below existing ground level (EGL) at rig location. (iv) Rock Quality Designation (RQD) of 25% and less shall be considered under this item. | |||||
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
cancelled_1.pdf
pdf • 0.27 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.96 MB
TSR.pdf
Tender Documents • 6.26 MB
TENDER_DRAWING.pdf
Tender Documents • 5.32 MB
TECHNICAL_BID.xls
Tender Documents • 0.14 MB
SCHEDULE.pdf
Tender Documents • 0.43 MB
BOQ_935927.xls
BOQ • 0.64 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .