| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹42.7 L+₹5.3 L (14.1%)Rejected-Finance | L2 | Rejected-Finance Not being Lowest. | |
| 3 | L3₹44.0 L+₹6.5 L (17.4%)Rejected-Finance | L3 | Rejected-Finance Not being Lowest. |
| Sl No | Description | Qty | Unit | S J REDDY L3 | Venkat Ramaiah L1 | GUTHIKONDA BROTHERS L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed. | 74.8 | Cum | 449.57 ₹33,627.84 | 400 ₹29,920 Lowest | 500 ₹37,400 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 51.6 | Cum | 112.39 ₹5,799.32 | 125 ₹6,450 | 100 ₹5,160 Lowest |
| 3.00 | Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | 16 | Cum | 184.64 ₹2,954.24 Lowest | 200 ₹3,200 | 250 ₹4,000 |
| 4.00 | M& L for Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed. | 4.5 | Cum | 5,619.6 ₹25,288.2 | 5,000 ₹22,500 | 4,500 ₹20,250 Lowest |
| 5.00 | M&L for RCC M-25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed. | 13 | Cum | 6,422.4 ₹83,491.2 Lowest | 6,650 ₹86,450 | 7,000 ₹91,000 |
| 6.00 | M&L for RCC M-25 Columns, pillars, piers, posts and struts complete all as specified and as directed. | 4 | Cum | 6,422.4 ₹25,689.6 Lowest | 7,000 ₹28,000 | 7,000 ₹28,000 |
| 7.00 | M&L for RCC M-25 Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed. | 5 | Cum | 6,422.4 ₹32,112 Lowest | 7,000 ₹35,000 | 7,000 ₹35,000 |
| 8.00 | M&L for RCC M-25 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. | 12 | Cum | 6,422.4 ₹77,068.8 Lowest | 7,000 ₹84,000 | 7,000 ₹84,000 |
| 9.00 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surfaces complete all as specified and as directed. | 49 | Sqm | 642.24 ₹31,469.76 | 450 ₹22,050 Lowest | 500 ₹24,500 |
| 10.00 | M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed. | 55 | Sqm | 642.24 ₹35,323.2 | 450 ₹24,750 Lowest | 500 ₹27,500 |
Tender Value
₹47.4 L
EMD Value
₹94,867
Closing Date
4 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AFA) Hyderabad
GE (AFA) Hyderabad, Dundigal, Hyderabad
PROVISION OF CERTAIN REVENUE MAJOR WORKS AT AFA HYDERABAD
2025_MES_735145_1
8611/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE (AFA) HYDERABAD
₹94,867
Yes
31 Dec 2025
14 Oct 2025
6 Nov 2025
14 Oct 2025
4 Nov 2025
28 Oct 2025
14 Oct 2025 - 27 Oct 2025
Amount
M&L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/Dense Soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
M& L for Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M&L for RCC M-25 Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
M&L for RCC M-25 Columns, pillars, piers, posts and struts complete all as specified and as directed.
M&L for RCC M-25 Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC M-25 Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surfaces complete all as specified and as directed.
M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and as directed.
M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and as directed.
M& L for Pre-cast cement concrete block masonry with type C1 (1:3:6) using 20 mm graded stone aggregate solid blocks, exc. 10 cm in width and setting in cement mortar 1:6, complete all as specified and as directed.
M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed.
M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia all as specified and directed
Ditto but as in stirrups, spacer etc
M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 surface finished even & smooth without using extra cement complete all as specified.
M & L for Rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished even & smooth without using extra cement complete all as specified.
M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement with using WPC complete all as specified. (WPC shall be measured and paid separately).
M & L for Rendering 10 mm thick on concrete surfaces of roof in CM 1:3 surface finished even & smooth without using extra cement with using WPC complete all as specified. (WPC shall be measured and paid separately)
Supply only of liquid waterproofing compound of approved makes.
M&L for applying three coats of white wash on walls including reparation of new plastered surfaces all as specified and as directed.
M&L for applying three coats of white wash on ceilings including preparation of new plastered surfaces complete all as specified and as directed.
Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in sub base flooring complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over and including 20 mm thick cement screed base in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete
M&L20 mm thick Granite stone (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, platforms, shelves and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite compleet all as specified and directed.
M&L Rolled Mild steel as in framed work Fe- 290 (Gde E-165) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete
M&L for 1.00mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, welded to frames all as specified and directed.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for Preparation of new Steel and Iron surfaces Surfaces of any description, over 10cm in width or girth,not otherwise described and painting with two coats of Synthetic enamel paint over a coat of red oxide primer all as specified and directed.
M& L for Plain Cement concrete 75 mm thick Type C1 1:3:6 (20 mm graded Aggregate) as in plinth protection laid in alternate bays not exceeding 2 Sqm each and finished fair on top without using extra cement. 6mm wide joints shall be provided throughout the thickness of plinth protection in concrete bays. All joints in bays of concrete, shall be filled with mastic filling comprising of one part of heated bitumen Vg-30 grade and 3 parts of sand (all by weight). all as specified and directed.
M&L for Roof treatment for in-accessible roof as under: - (i) Preparation of surfaces by sweeping cleaning and washing down with water to remove dust and loose particles over RCC slab for providing roof treatment. (ii) Apply polyurethane waterproofing coating on prepared concrete surface of roof slab & up to 300 mm of parapets and crumple joint including junction of roof and parapet whereever applicable. Any minor cracks in the screed should be sealed with grouting and crack filling material or epoxy sealant filler. This stage shall be passed by the GE. Roof surface shall be left without any further treatment. (iii) Method: Cleaning the surface and applying FOSROC Nitoproof 725 (min 0.8mm dft) over a priming coat of Nitoproof WB Primer or equivalent product of Asian paints , M/s M C Bauchemic / CIPY/ SIKA / Pidilite / Dr Fixit / Thermax / STP as approved by GE, applied as per manufacturer’s instructions. (iv) The work shall be carried out complete as per manufacturer’s specifications and application methodology. Execution to be done with authorised trained / skilled applicator of manufacturer as per technical guidance laid by manufacturer. Company guarantee to be given by contractor after completion of water proofing work before payment. (v) Ponding test for 72 hrs to be carried out and no leakage / seepage shall be ensured. Any rectification to be done at the cost of contractor repeating above steps of application to the entire satisfaction of Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm or removing the earth in hard/dence soil all as specified and directed.
M&L for Plain cement concrete 1:3:6, Type C2 using 40mm graded stone aggregate as in foundation, filling and mass concrete etc., complete all as specified and directed.
S&F of Structural Steel work as columns, posts, stanchions etc using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
S&F of Structural Steel work as in main and cross beams, hip and jack rafters, purlins where connected to common rafters , vertical posts, etc fixed with angle cleats or other connecting plates, cleats etc. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
S&F of Structural Steel work in tubular trusses including special shaped washer etc.. using ERW or induction butt welded tubes conforming to IS-1161-1998 grade St.-240 or with holow structural steel sections conforming to IS 4923-1997 Grade St-240 all as specified and directed.
M&L for Rolled mild steel in Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome primer on Surfaces of any description,over 10cm in width or girth, not otherwise described complete all as specified and as directed.
Removing excavated material (soils) exceeding 1.50 km but not exceeding 5 km and depositing where directed all as specified and directed.
M&L for rendering 15 mm in Cement Mortar 1:4 on fair faces of brick work or concrete surface walls finished fair and even complete all as specified and as directed.
M&L for preparation of new surfaces plastered or unplastered walls and applying two coats of cement base paint over a priming coat all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil.
M&L for PCC 1:4:8 type D2 (using 40mm graded stone agg) 75mm thick as in floor sub base etc as specified directed.
M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
M & L for providing cement concrete PCC 1:2:4 type B-1 mix using 20 mm graded stone aggregate as in kerbs, stoppers, edge stones etc including use of necessary formwork, straight or curved, finishing exposed surfaces etc complete all as specified and directed..
Taking down Steel windows / Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each but with shutters (without taking off shutters from the frames)
Taking down of cement or cement lime plaster of any description any thickness on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc complete all as specified and directed.
M&L for applying one coat of Oil bound distemper of any colour / shade on walls including reparation of old plastered surfaces over a coat of primer complete all as specified and as directed.
M&L for applying two coats of Oil bound distemper on walls including reparation of new plastered surfaces over a coat of primer over 3mm thick wall care putty complete all as specified and as directed.
S&F of Structural Steel work Fe 410-W (Gde E- 250) qualit for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) all as specified and directed.
S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
M&L for preparation of new steel surfaces and applying two coats of synthetic enamel paint over a coat of red oxide zinc crome primer on Surfaces of any description,over 10cm in width or girth, not otherwise described complete all as specified and as directed.
M&L for water proofing treament to walls and on Chajjas / Sunshades as under:- (i) Preparation of surfaces of walls and on chajjas / sunshades over walls above chajja up to 900 mm and up to 600 mm on either side of chajja width, picking, sweeping, cleaning and washing down with water to remove all loose particles, dust etc complete all as directed by Engineer-in-charge. Surface shall be moist by sprinkling water. (ii) Applying FOSROC Brushbond Wall guard / roofguard minimum 3 layers or equivalent product of Asian Paints, / M/s MC Bauchemie / CIPY/ SIKA / Pidilite Dr Fixit/ Thermax / STP as per the manufacturer’s instructions.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided all as specified and directed by Engr-in-Charge.
M&L for 75mm thick PCC (1:2:4) type B-1 using 20mm graded aggregate as in floors for pavings, hardstaning and plinth protection etc finished fair and even etc including joint cutting and filling the joint shall be filled with mastic filling compraising of 01 part of heated bitumen blown grade any penetration and 3 parts of sand (all by Weight) complete all as specified and directed.
Surface excavation n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out in hard / dense soil.
M&L for hardcore of gauge n exc. 63 mm of broken stone boulders, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface.
M&L for Chequered cementconcrete tiles 30cm x30cm x 25mm thick, with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors laid over 20 mm thick scrred in cement mortar 1:6 including demolition of old tiles all as specified and directed by Engr-in-Charge.
M&L Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering all as specified and as directed.
M& L for 100 mm thick Plain Cement concrete Type 1:2:4B1 using (20 mm graded Aggregate) as in floor and pavings etc surface finished even and smooth without using extra cement complete all as specified and as directed.
M& L for 100 mm thick Plain Cement concrete Type D2 1:4:8 (40 mm graded Aggregate) as in sub base flooring complete all as specified and as directed.
M&L Aluminium dividing strips, 1.5mm thick, inserted in position, conform to design 38 mm strip complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises to a distance exceeding 1.5 K but not exceeding 5 Km complete all as specified and directed..
Demolition of cement concrete of any description and in any position not otherwise specifically provided for.
Taking down cement plaster from walls /ceilings built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster.
M&L for 25 mm thick PCC 1 : 2 : 4 type B-0 using 12.5 mm graded stone aggregate as in screed bed in floors all as specified and directed.
M&L for Screed bed or bedding layer of 15mm thick in CM 1:6 for laying floor finishes complete all as specified and as directed.
S&F 5mm thick Rubber tiles with fabric backing or insert, plain coloured or marbled topping, matt or glossy, laid in floors including Approved adhesive for setting rubber tiles or sheeting complete all as directed
M & L for rendering 10 mm thick in cement mortar 1 : 4 on brick or concrete surfaces as in screed bed all as specified and as directed.
S & F Vitrified Ceramic coloured tiles 10 mm thick Light shade, polished area of each tile not exc 0.36 sqm, set and jointed in neat cement slurry and pointed in white or coloured cement to match in skirting/ dado
M & L for rounding to edges of stone slabs one edge, such as in steps, cooking platforms, and other similar situations
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM (1:6) finished even and smooth without using extra cement.
M&L for preparation for new surface on ceilings and applying two coats of oil bound distemper over a primer over 3mm thick wall care putty on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for Powder Coating (minimum thickness of powder coating 50 micron) aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
M&L for powder coating of any colour (Thickness or powder coating not less than 50 micron) aluminium window shutters, top hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified
S&F 3 mm thick Figured glass, pin head type and glazing with aluminium beading in squares n.exc 0.5 sq. m in each pane all as specified and directed.
Providing & fixing 12mm thick micro tegular false ceiling at all heights with GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2% humidity resistance of 99%, NRC0 .50 to 0.75 as per IS 8225 :1987, Noncombustible as per BS 4 76 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) comprising of main T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm , suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1OOOmm length and L- shape level adjuster of size 85x25x2mm . Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications , drawing and as per directions of the Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description including rolling shutters etc not otherwise provided for
M&L for RCC M-25 (design mix) as in Chajjas complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat all as specified and directed.
M&L for RCC M-25 (design mix) as in Chajjas complete all as specified and as directed.
Formwork to chullah hoods, chajjas, troughs and similar items including edges for rough finished surfaces of concrete flat all as specified and directed.
Providing precast cement concrete with 1:3:6 type C1- using 20 mm graded stone aggregate solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) set in mortar 1:4 in walls complete all as specified and directed.
S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 50 x 100 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum comp ressive strength of 58 N/mm2, modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made
S&F 100mm stainless steel butt hinges, cold rolled medium weight
M & L for Brass handles, cast type, polished bright 150 mm long all as specified and directed
S&F of 100mm Aluminum anodised barrel tower bolts of extruded section complete all as specified.
S&F 250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloy complete all as specified.
S&F 4mm thick Figured glass, pin head type and glazing fixed in aluminium frames with rubber beading/gasket in squares n exc 0.5 sq. m in each pane complete all as specified.
Anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer in-charge
M&L 25 mm thick plain Cement concrete 1:2:4 mix type B-0 using 20mm graded aggregate as in screed concrete complete all as specified and as directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing laid over and including screed bed or bedding layer of mortar 20mm thick complete all as specified
M&L for Machine cut kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado and pillar laid over and including 10mm cement screed in 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M & L for flame proof point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including stove enamelled steel conduit, ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes, Modular White Cover Plates with frames etc. of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases (if any) for conduits & sinkings for modular boxes, necessary fixing arrangements & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI. (a) One Light/E/Fan point controlled by one switch 5/6 Amps. NOTE : 1) Stove Enamelled Steel Conduit etc. is deemed to be included in the unit quoted rates. 2) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates.
M & L for sub-main wiring alongwith earth wire of size (2 x 1.5) sq. mm + (1 x 1.5) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. NOTE : 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S&F ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite three terminal complete all as specified and directed. Make: Havells/Legrand/Anchor
S & F Switch, Flame Proof Rotary type with termination box in LM6, 16A, Single Pole, 250 V. Make : Sudhir/Crompron/Philips.
S&F LED light fitting 1 x 16W flame proof, CMRI certified recommended for gas/vapour group of IIA & IIIB, Zone 1 & 2 & IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixtures driver, holders, connectors etc. complete with all accessories prewired & including connecting up with three core flexible copper conductor cable with suitable size. Make : Sudhir/Crompron/Philips.
S&F Exhaust Fan 305 mm (12") flame proof, 1440 RPM, 1120 CFM, 0.25 HP, recommended for gas/vapour group of IIA, IIB, IIC, Zone 1 & 2 & IP 65 protection with die cast aluminium housing, epoxy powder coated, Class F Insulation, CIMFR/BIS/PESO Certified, T6 temperature class etc. complete with all accessories prewired & including connecting up with three core flexible copper conductor cable with suitable size. Make : Sudhir/Crompron/Philips.
Supply and fix energy saving high power LED building security light of 30W made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection, IK-09 and making electric connections in flexible conduit with & incl GI Pipe bracket of appropriate dia & necessary fixing arrangements like clamps, nuts, bolts, washers etc. incl taking down old unsv one complete all as specified & as directed by Engr-In-Charge/GE. Make : LUKER, Cat No LSTE030S or techno-commercially Equivalent in Havells/Jaguar/Philips. Note : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis (if any) to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items before placing final order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates. 3) Original Purchase Vouchers, Manufacturer's Warrantee/Guarantee Certificates & Test Certificates to be submitted to Engr-In-Charge for checking & record.
S & F SPN DB, 8 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. NOTE for Item above : Make of MCBs shall be same as the make of MCB DBs.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv one complete. Make of GI Pipe : TATA/Jindal/Prakash
Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for laying of pipe and getting out in hard dense soil complete. NOTE for Item No 12 : 1) The requirement of JCB (if any) for cutting the hard standing/PCC/WBM road surface or during earthwork is deemed to be included in the unit quoted rates. 2) If any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. 3) Quoted rate is also deemed to be inclusive of clearing/removing/cutting of vegetation/tree branches/small to medium plantings/bushes etc. (if any) so as to facilitate successful completion of the work. No extra/addl payment shall be allowed to the Contr in this regard. 4) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 63 mm & Min ID 50 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 incl necessary clamping arrangements for fixing on wall or other surfaces etc. complete all as specified & as directed by the Engr-In-Charge. Make : Telerix/Supreme/Finolex.
Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc complete all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/Gloster
M & L for point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallin PVC rigid conduit, ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes, Modular White Cover Plates with frames of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases (if any) for conduits & sinkings for modular boxes, necessary fixing arrangements & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI, Make of Conduit : Precision/Finolex/Polycab/Modi (a) One Light point controlled by one switch 5/6 Amps.
(b) One C/Fan Point controlled by one switch 5/6 Amps.
(c) One switch socket outlet point 5/6 Amps on independent board.
Description all as per Item above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. NOTE for Item above: 1) Modular metal flush boxes, Modular White Cover Plates with frames is deemed to be included in the unit quoted rates. 2) Cutting chases (if any) & making good the disturbed surfaces is deemed to be included in the unit quoted rates. 3) The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets.
S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab Note for Item above : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned.
S&F ceiling rose surface PVC/ Polycarbonate, Isolated body with face Bakelite three terminal complete all as specified and directed. Make: Havells/Legrand/Anchor
S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing provided for efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT520P or techno-commercially equiv in Havells/Jaguar/Philips. Note : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
S & F SPN DB, 8 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB. NOTE for Item Nos 8 to 10 : Make of MCBs shall be same as the make of MCB DBs.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6.3 mm thick buried directly in ground (in vertical position) earth pit not less than 2.25 mtr below normal ground level with the top edge of the earth plate not less than 1.5 mtr (B.G.L.) and connected to galvanized iron wire 4 mm dia by means of bolts, nuts, check nuts, and washers of galvanized iron including PCC pit & cover with suitable handle including necessary excavation and earth work in any type of soil, 20 mm dia med grade galvanized steel tube for watering with one end fixed with funnel and wire mesh, 15 mm bore medium grade galvanized steel tubing for drawing earth lead GI strip protection & common salt, charcoal in alternate layers etc. complete all as shown in EP No 3 of SSR Part 1 and testing on completion incl taking down old unsv one complete. Make of GI Pipe : TATA/Jindal/Prakash
M&L for HDPE DWC (Double Wall Corrugated) Pipe of rating 450 N, ISI marked with Min OD 63 mm & Min ID 50 mm, Orange colour for LT UG Cable protection with & including Couplers with rubber rings & RR & NFP properties/features confirming to IS 16205 Part 24:2018 & IEC 61386 Part 24:2007 incl necessary clamping arrangements for fixing on wall or other surfaces etc. complete all as specified & as directed by the Engr-In-Charge. Make : Telerix/Supreme/Finolex.
M & L for surface sub-main wiring alongwith earth wire of size (2 x 4.0) sq. mm + (1 x 4.0) sq. mm earth wire, ISI marked, FRLS, PVC insulated, multi stranded, copper conductor, single core cable drawn through and including non-metallic PVC conduit (medium grade) with all fittings and accessories ISI marked for conduits & sinkings for modular boxes & making good to walls, floors etc. complete all as specified & as directed. Make of cable : Havells/Polycab/Finolex. Make of Conduit : Polycab/Finolex/Modi/Precision.
Description all as per Item here in before but of size (2 x 2.5) sq. mm + (1 x 2.5) sq. mm earth wire complete all as specified & as directed. NOTE for Item Above: 1) Two runs of PVC wire, one run of earth wire & one run of PVC rigid conduit (medium grade) will be measured as one length. 2) Modular metal flush boxes (if req) shall be measured & paid separately. 3) Cutting chases & making good the disturbed surfaces (if any) is deemed to be included in the unit quoted rates. 4) Cost of PVC clamps with fixing screws for fixing on walls &/or PVC cable ties etc. for fixing on steel support members (if any) is deemed to be included in the unit quoted rates. 5) The wiring shall be done with proper colour coding using Red, Yellow & Blue Coloured wires only for Phase, Black for Neutral & Green for Earth Wire.
S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab Note for Item Nos above : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned.
S&F Ceiling Fans complete with blades, down rods, electronic regulator (compatible for BLDC Fans) & accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with BLDC mtor complete all as specified & as directed. Make : HAVELLS/BAJAJ/USHA/KHAITAN. Note : (i) Installed C/Fans Warranty card duly signed by the user should be submitted to the Engr-in-Charge (ii) The cost of making good the disturbed surface & fixing arrangements required is deemed to be included in the quoted rate.
S & F LED square shape (2' x 2') Dimmable slim ceiling RECESS Panel 40 W or next higher rating, CRI > 80, CT>5700 K (White), integrated type, with high efficiency electronic driver, surge suppressor/protection & high brightness LEDs, with suitable fixing arrangement complete with all accessories internally prewired and including connecting up with and including twin/three core twisted flexible copper conductor cable of suitable size with & including 0-10 V DC O/P Touch Panel Dimmer, 50 mA O/P complete all as specified and as directed. Make of LED Ftg : Cat No : LPSD40 of make Luker or techno-commercially equiv in Havells/Jaguar/Philips & Make of Dimmer : Cat No LLDIM110V of make Luker or techno-commercially equiv in Havells/Jaguar/Philips Note : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
S & F TPN DB, 4 Way, IP43, IK09, Metal double door type 415 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, TPN, C-Series 415 Volts of capacity 40-100 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. (1W+1S) Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F single pole & neutral sheet metal enclosure with a two pin & earth plug & socket complete with one single pole MCB, "C" Curve, 10 KA, 20A all as specified & as directed to the entire satisfaction of the Engr-In-Charge. NOTE for Item above : Make of MCBs shall be same as the make of MCB DBs.
Supply, install, commissioning & testing of hi wall, split-type Air Conditioner Unit of capacity 2.0 TR or higher rating based on Inverter Technology comprising of variable speed copper compressor suitable for adjusting power depending on heat load incl indl indoor & outdoor units complete with cordless remote control unit & with in-built stabilizer free operation, PM 2.5 Filter, Anti-dust Filter, Audjustable Mode, 4-way swing with & including the feature of "SUPER DRY" mode to facilitate humidity control etc. for better indoor air quality with 5 star rating incl electric connection complete all as specified and as directed. Make : BLUESTAR/DAIKIN/HITACHI/VOLTAS/CARRIER.
(i) Technical Specifications/particulars etc. of the Split ACs is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer. (ii) The Air Conditioner shall be initial filled / charged with refrigerant of specified quantity & the refrigerant to be used shall be Non-CFC type & as per the latest technology. (iii) Unit Quoted rates shall be deemed to be inclusive of the following connected items/job/work etc. : (a) Cost of copper refrigerant pipes for suction and discharge lines for connection of indoor to outdoor units of 1.5 ton split AC of standard size as per OEM recommendation with proper insulation including fixing arrangement with appropriate size MS clamps and jointing of pipe with brazing etc including all necessary items required complete all as specified and directed by Engr-in-Charge. (b) Cost of 3 core weather proof copper cable (size as recommended by OEM), multistranded for electrical connection of Indoor & Outdoor Units. (c) Cost of PVC pipe 25mm dia high grade for ACs drain water suitable for outdoor mounting including connecting tees, bends, reducers etc. for leakage free jointing etc, including appropriate size PVC clamps and other required material for fixing on wall/cemented surfaces at heights as specified here in above complete all as specified and directed by Engineer-in-Charge. (d) Cost of making of holes to existing wall/wooden panelling etc. using core cutting machine of suitable dia for the run of copper refrigerant tubings, connecting cables etc. and making good the distrubed surfaces/false ceilings etc. complete all as directed by Engr-in-Charge. (e) Cost of MS angle iron frames of minimum size 50 mm x 50 mm x 6 mm suitable for fixing of Outdoor Units of Split AC's 1.5 Ton including fixing on wall/other surfaces etc. with necessary fixing arrangements like nuts, bolts, washers etc. as required on ground inclusive of one primer coat, one under coat and one finishing coat of synthetic enamel paint complete all as specified and directed by Engr-in-charge. (f) Cost of PCC 1:2:4, type B1 using 20 mm graded stone aggregate as in platform/plinth for embedding/holding of MS angle iron frames as cited here in above for fixing of Outdoor Units of Split AC's 1.5 Ton incl necessary formwork & applying two coats of white wash to exposed surfaces complete all as specified and directed by Engr-in-charge. (g) Cost of making good the disturbed surfaces incl matching to the existing/old surfaces.
(h) Cost of neatly writing/marking MES Number on the body of Split AC Indoor Unit using stencil of size/dimensions complete all specified & as directed by the Engr-In-Charge. (j) Cost of 01 x Air Conditioning Changeover Timer, suitable for 2 x AC loads of 16 A i.e. AC1-16A & AC2-16A, with Auto & Manual mode with interval/gap time of 30 Mins, 1 Hr, 2 Hr, 3 Hr, 4 Hr, DIN Channel mounting for easy operation incl electric connection with suitable sized single core copper wires/cables & testing complete all as specified & as directed to the entire satisfaction of the Engr-In-Charge. (iv) All the necessary OEM/Auth Supplier Test Certificates as per relevant IS/IEC incl the Guarantee/Warranty Certificates is to be submitted in Original to the Engr-In-Charge. (v) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates. (vi) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.
Supply, install, commissioning & testing of wall-mounted copper wound voltage stabilizer, ISI marked for automatic operation, single phase, naturally air cooled, indoor type & designed for I/P variation between 175 V to 250 V with Digital Voltmeter & O/P voltage stabilization at 230 V with accuracy of +/- 2.5%, with high & low voltage cut off & time delay & of capacity 5.0 KVA suitable for 1.5 TR Inverter AC incl electric connection complete all as specified and as directed. Make : APLAB/VENER-7/SINETRAC or Techno-commercially equivalent makes as approved by HQ CE Commands. Important Notes for Item Nos above: (i) Technical Specifications/particulars etc. of the Items is to be obtained from OEM / Auth Supplier & is to be got approved from the GE & Engr-In-Charge before placing final order to the manufacturer. (ii) Anything missed out in the technical specifications but technically required for efficient working of the AC is deemed to be included in the unit quoted rates. (iii) All the necessary OEM/Auth Supplier Test Certificates as per relevant IS/IEC incl the Guarantee/Warranty Certificates is to be submitted in Original to the Engr-In-Charge. (iv) The contractor/firm is required to visit the site prior to quoting of the subject items/ work so as to ascertain the actual ground requirements. Any further query at a later date shall not be entertained & responsibility of the same shall rest on the contractor/ firm.
M & L for concealed point wiring with two single core 1.5 sqmm PVC insulated, unsheathed, FRLS cable, 1100 volts grade, ISI marked with multi stranded copper conductor drawn through and including non-metallic PVC rigid conduit (medium grade), ISI marked with all fittings and accessories ISI marked incl provision of 1.5 sqmm PVC insulated, multistranded, unsheathed, copper conductor cable, FRLS, ISI marked as earth continuity conductor (green in colour) & incl fixing of modular metal flush boxes of appropriate size & thickness fixed flush to wall for mounting switch, sockets etc. with including cutting chases for conduits & sinkings for modular boxes & making good the disturbed surfaces, matching to the existing one etc. complete all as specified & as directed for the following : Make of cable : Havells/Polycab/Finolex/KEI (a) One Light/fan etc. point controlled by one switch 5/6 Amps.
(b) One switch socket outlet point 5/6 Amps on independent board.
Description all as per above but with FRLS PVC insulated copper conductor cable of size 2.5 Sqmm and 2.5 Sqmm for earth continuity conductor green in colour for 16A switch socket complete. NOTE for Item Nos above : 1) Modular metal flush boxes shall be measured & paid separately. 2) Cutting chases & making good the disturbed surfaces is deemed to be included in the unit quoted rates.
S & F Modular switch, one way, 6 Amp, 1 Module, 240 volt complete all as specified and as directed. Cat No : ACVSXXW061, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular switch, one way, 16 Amp, 1 Module, 240 volt with Indicator complete all as specified and as directed. Cat No : ACVSXXW161, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular shuttered socket outlet 3 Pin, 6 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKSWW063, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
S & F Modular shuttered socket outlet 3 Pin, 6/16 Amp, 2 Module, 240 volts, ISI marked complete all as specified and as directed. Cat No : ACVKCWW163, Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab Note for Item Nos above : Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned.
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 1/2 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 3 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
Supply & Fixing and concealing modular metal flush box suitable for fixing switches/sockets of 6 modules all as directed. Make : VERONA (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 1/2 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 3 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab
Supply & Fixing modular cover plate suitable for fixing switches/sockets of 6 modules all as directed. Model - Verona of make CRABTREE (Havells) or techno-commercially equiv In Legrand/Anchor Roma/Polycab NOTE for Item Nos above : The make/model of modular metal flush boxes & modular cover plates shall be same as that of modular switches & sockets.
S&F Surface and wall mounted LED batten 20 watts 4 feet long, extruded aluminium housing provided for efficient heat dissipation & integrated electronic driver including connecting up with and including twin/three core twisted flexible cable of suitable size in flexible conduit all as specified and as directed. Make : LUKER, Cat No LT520P or techno-commercially equiv in Havells/Jaguar/Philips.
Supply and fix energy saving high power LED building security light of 30W made up of pressure die cast aluminum housing with embedded PC cover having top opening, seperate driver compartment with IP66 protection, IK-09 and making electric connections in flexible conduit with & incl GI Pipe bracket of appropriate dia & necessary fixing arrangements like clamps, nuts, bolts, washers etc. complete all as specified & as directed. Make : LUKER, Cat No LSTE030S or techno-commercially Equivalent in Havells/Jaguar/Philips.
S & F SPN DB, 8 Way, IP43, IK09, Metal double door type 240 volts fitted with busbar and blanking plates, neutral link and making good making good the disturbed surfaces with all other accessories including necessary connection all as specified and directed by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SPN, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA all as specified and dircted by Engr-in-Charge. Make-L&T/LEGRAND/SIEMENS/ABB.
S&F MCB, SP, C-Series 240 Volts of capacity 6-32 Amps with breaking capacity 10 KA. Make-L&T/LEGRAND/SIEMENS/ABB. Imp Note for Item Nos above : 1) Design/Drawing/Technical catalogue/specifications along with comparative Rate Analysis to be submitted to the Engr-In-Charge/GE for Make/Sample approval of items whereever equivalency of Item(s) is concerned other than specified Make/Model/Cat/Part Ref concerned before placing order to the Manufacturer/Supplier. 2) Anything missed out in the technical specifications but technically required for efficient working is deemed to be included in the quoted rates.
Supply and laying light grade GI Pipe (ISI Marked) of 40mm dia for cable protection to be fixed on wall with necessary clamps or in road crossing,complete all as directed. Make: TATA/Jindal/Prakash Note : Rate qouted shall include MS clamps of required size wherever GI pipes are to be fixed on wall,poles etc
M & L for cutting the existing hard standing/PCC/WBM road at a depth not less than 45 cm and 25 cm in width for passing of cable through GI pipe, returning filling in, complete including finishing the surfaces by providing top 30 cm thick cement concrete type B-1 (1:2:4) using 20 mm grade aggregate, bottom filled with excavated earth and remain finishing to a uniform smooth surface complete all as specified and directed. NOTE : If the event of any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates. NOTE : If the event of any damage to any Cable of Air Force/BSNL/MES etc. or to any Pipe lines develops/occurs during execution of the works then the same shall be made good by the Contr to the entire satisfaction of the concerned Dept/Section & the costs of the same is deemed to be included in the unit quoted rates.
Supply and laying in trenches/through pipes or bare in road crossings/ paths /drains /ducts /floors /along poles/ walls/ ceilings/ equipments etc. Cable Under ground, armoured, XLPE insulated with stranded aluminium conductor, 1100 Volts grade of cross sectional area, 4.0 Core 10 Sqmm incl connecting with suitable glands, lugs etc all as specified and directed by the Engr-in-Charge. Make: Havells/Finolex/Polycab/Gloster. Note : Rate qouted shall include MS clamps of required size wherever cable will be passing through GI pipes to be fixed on wall,poles etc.
S&F Ceiling Fans complete with blades, down rods, electronic regulator (compatible for BLDC Fans) & accessories, 230 V, 1200 mm sweep, min air delivery 210 CFM with service value 6.00 BEE, 5 Star rated with BLDC mtor complete all as specified & as directed. Make : HAVELLS/BAJAJ/USHA/KHAITAN
M&L for air termination, single pointed aluminium rod 12 mm dia and 300 mm long including fixing arrangement with porcelain saddles/insulators, fixing screws etc. complete all as specified and as directed.
M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x40 mm, drilled and screwed including 3 Nos 8 mm dia 25 mm long hex head screw all as specified and directed.
M&L Aluminium strip 25x3.15 mm with DMC/FRP insulators of size not less than 50 mm and fixing screws etc. for roof conductors @ 1.0 Mtr spacing and down conductors @ 1.2 Mtr spacing above ground complete all as specified and as directed.
M&L GI Strip 32x6 mm with DMC/FRP insulators of size not less than 50 mm and fixing screws etc. for down conductors above/below ground @ 1.2 Mtr spacing above groundcomplete all as specified and as directed.
M&L for PCC (1:2:4) Type B-1 (using 20 mm graded stone aggregate) for mounting base of DMC/FRP insulators etc. & finishing the surface even and smooth without using extra cement incl necessary framework complete all as specified and directed. Note : In horizontal run the space between saddles/porcelain insulators/PCC blocks shall not be more than 1.0 mtr & for vertical/above ground run the spacing shall not be more than 1.20 mtr.
M&L for GI pipe light grade with all running fittings (ISI Marked), laid in trenches, under road or fixing on wall/pole/crossing drain/nallah etc. of bore 40 mm complete all as specified and directed. Make : TATA/JINDAL/PRAKASH. IMP NOTES FOR ITEM above : 1) Design / drawing / Layout of the complete Lightning Protection System is to be to be got approved from Engr-in-charge & GE before placing final order. 2) Any item/work etc. missed out in the technical specifications but technically required for efficient working of the complete system is deemed to be included in the quoted rates. 3) On completion of the complete work/job the Contr is to perform earth resistance tests for each earthing job in the presence of the Engr-In-Charge or his rep & submit test certificates duly signed & certified. If the test results are not satisfactory or not within the permissible limits of relevant Standards/IS then the job is to be redone without any extra cost to the Dept till the results are satisfactory. 4) The size of PCC Blocks shall be 150 x 150 x 150 mm.
GUTHIKONDA BROTHERS (BID ID -3471699)
S J REDDY (BID ID -3471765)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.11 MB
8611TENDERPAGES.pdf
Tender Documents • 0.57 MB
BOQ_823191.xls
BOQ • 0.62 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .