Executive Engineer, Electrical Division, HP.PWD Ma
Executive Engineer, Electrical Division, HP.PWD Mandi
Construction of Sanskriti Sadan at Motipur, District Mandi H.P SH Providing Fire alarm system and addressable system therein
2019_PWD_31615_1
PW/MED/TA/NIT/ e-notice/19-20-4141-47 dt 05.09.19
Open Tender
Electrical Works
Item Rate
365 days
Mandi
Plz refer to bid document
10 documents required · 10 mandatory
₹500
Executive Engineer, Electrical Division, HP.PWD Ma
₹43,850
1 Sept 2020
20 Sept 2019
30 Sept 2019
20 Sept 2019
30 Sept 2019
20 Sept 2019
Amount
Supply, installation, testing & commissioning of UL listed, 9th edition 32 bit Fire alarm control panel having microprocessor based 2 loop cards expandable upto 5 loops with 252 intelligent points per loop cards in any flexible combination (detectors or devices ). The panel shall have the capacity of storing upto 5000 events. Further, the panel must be able to automatically switch ON /OFF respective control module when ever any alarm is triggered. The panel have 6 inch long LCD touch screen and LED's for displaying system status. In addition to the digital screen, the user can view a graphics map which can show a simple building floor plan. The panel shall provide the user with 40 programmable macro or function buttons, which can be programmed for a variety of usages like controlling AHU's, Pressurisation fans, fire pumps, monitoring of flow switches in fire pipe line etc. The panel shall have a built in power supply of 170 Watts and battery charger. Battery charger shall be able to charge the system batteries upto 100 AH. The panel shall have 240 V AC power supply, 24 V SMF batteries sufficient for 24 hour in standby and 30 minutes in alarm complet as per specification. The Panel shall have the capacity of connecting additional 15 panels or Network terminals using network card. The panel shall have the capacity of connecting maximum 8 Remote terminals or 8 remote displays using RS 485 card. Bacnet/Modbus interface card for BMS integration. complete in all respect. Makes: Gamewell/ Bosch/Siemens
Supply,Installation,Testing and Commissioning of UL listed and FM approved repeater panel with minimum 160 characters backlit LCD display & with event and audiable status LED's, scroll buttons to view additional events, local sounder and provided in its own enclosure. complete in all respect. Makes: Gamewell/Bosch/Siemens
Supply,Installation,Testing and Commissioning of UL listed and FM approved Intelligent Addressable Multi-criteria detector with Fire Print Technology having responsivness of photoelectric, thermal,and false alarm resistance along with standard base. Multi-criteria detector shall be an intelligent digital photoelectric detector with a programmable heat detector. The detector shall have 11 sensitivity level and with tri color LED, Green for Normal, Amber /yellow for trouble and Red for alarm. Shall be Polarity Insensitive and fecility to mount in different comprehensive environment like Hostile environment, Parking Garage,HVAC Ducts, Precious storage,Transformer rooms, Ware house, Dormitory and normal working environments. complete in all respect. Makes: Gamewell/Bosch/Siemens
Supply,Installation,Testing and Commissioning of UL listed and FM approved addressable Single/ Double action Manual Pull Station. Shock and Vibration Resistant, Pull Down Lever Remains Down Until Reset. Shall be Polarity Insensitive. complete in all respect. Makes: Gamewell/Bosch/Siemens
Supply,Installation,Testing and Commissioning of UL Listed Conventional Sounder with strobe having multi tone settings with range of 78 dbA to 87 db. complete in all respect. Makes: Gamewell/ Bosch/Siemens
Supply,Installation,Testing and Commissioning of UL listed and FM approved Intelligent addressable control module. complete in all respect. Makes: Gamewell/Bosch/Siemens
Supply, installation, testing and commissioning of Response Indicator. complete in all respect. Make: Custom
Supply, installation, testing and commissioning of LED type fire exit sign board of size 300mm x 250mm x 1.5 mm. complete in all respect. Make: Falcon
Supply and erection of PVC insulated two core FR copper conductor cable ISI marked in PVC pipe recess/surface complete in all respect. Make - Finolex / Polycab /Hawells
Supply, installation, testing and commissioning of Universal power supply 24 V/ 5 A shall be operated at 100-240VAC, output voltage 26V to 29V DC. complete in all respect.
Supply and erection of PVC pipe 25mm dia ISI marked (Medium) recessed in wall / ceiling etc. including the cost of PVC bends , inspection boxes , iron hooks and cement concrete etc. complete in all respect upto the entire satisfaction of Engineer-in-charge of work. Make: BEC/Diplast /Polyplast
Supply, Installation, Testing and Commissioning of Beam detector incuding mounting base along with Interface module to direct connnect to the loop , having a coverage area with a distance of min. 10 m and max. 100 m with extra width of up to 14 m ,Operating temperature range: -20 C to +55 C. complete in all respect. Makes: Gamewell / Bosch / Siemens
Supply, Installation, Testing and Commissioning of Voice Alarm Controller 8-zone system controller: 8 Zone Paging system with pre-recorded messages for voice evacuation, Adopts LCD screen for easy operation, Simple integration with Fire Alarm Panels to activate EVAC/ALERT pre-recorded messages. Built-in MP3 (USB) and FM/AM functions, Built-in loudspeaker for performing broadcast monitoring, with special monitoring volume control,1 line input, 1 microphone input, provides mix and emergency paging output modes, Provides 8 broadcast zone output function, the peak power of each zone is 400W, and the total power of the all 8 zones is 1000W, 1 alarm activation input. complete in all respect. Make: Honeywell / JBL/ Marten Audio
Supply, Installation, Testing and Commissioning of 480Watts Power Amplifier : 100V,70V and 4-16 Ohms transformer isolated, Combination XLR /RCA Line In and Line OUT, LED status indicators, Speaker output short circuit protection, Frequency response-60 Hz~15 kHz ( ± 3 dB ), S/N >80dB. complete in all respect. Make: Honeywell / JBL/ Marten Audio
Supply, Installation, Testing and Commissioning of wall mount speaker with 6 watt operation. complete in all respect. Make: Honeywell / JBL/ Marten Audio
Supply, Installation, Testing and Commissioning of 3KVA online UPS, Double conversion, Microprosser controlled with LCD with 60 min. backup. complete in all respect. Make: APC/Emerson/Numeric
Supply, Installation, Testing & commissioning of 2 core 1.5 sq.mm speaker cable complete in all respect. Make : Finolex/Polycab/havel's
Supply, installation, testing and commissioning of 12 U Standard rack to place all equipment. complete in all respect. Make: Valrack, Comrack,HCL
Shanti Infotech
TARUN FIRE SYSTEM
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .