Tender Value
₹45.9 L
EMD Value
₹91,800
Closing Date
13 Aug 2022, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
DAY TO DAY MAINT OF INTERNAL ELECTRICAL AND WATER SUPPLY UNDER AGE E/M-I OF GE DEHRADUN.
2022_MES_539042_1
8509/A/E8
Open Tender
Civil Works
Item Rate
240 days
GE Dehradun
Class D cat b (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹91,800
Yes
17 Oct 2022
18 Jul 2022
15 Aug 2022
18 Jul 2022
13 Aug 2022
1 Aug 2022
Amount
M&L providing services for daily repair/ maintenance and attending all electrical fault/complaints of OTM and MD accn at Birpur - Ghanghora area including identifing the faults, making good the damaged electrical items and restoring the normal functioning of the electricity completefor continuity of essencial internal service to the satisfaction of User. And providing suitable size of lugs, nut - bolt with washers etc. PVC insulation tap andjointing materal.all as specifid and directed.
M&L providing services for daily repair/ maintenance and attending all electrical complaint like electrical Fixture & fittings refixing/ replacement of unservicebal items after removing unserviceable /burnt out items such as lamp holder, tube lights, Making connection of electrical circuit and similar work for continuity of essencial internal serviceto the satisfaction of Engineer in charge by using stores issued by the dept all as directed
M&L providing services for daily repair/ maintenance and attending all electrical complaints related to electric faults of ditribution system, like short circuite of sub main wiring or electri circuit, MCB distribution Board, repair/re-fixing after scraping, cleang of carbanised part/ carbon surface by using CRC solution and making tightening cable connection properly with new nut - bolts with washer PVC insulation tape etc. obtaining complaints from user including repair/ replacement of sub main wiring and making good repair to existing damaged plaster/ PCC floor. and similar work for continuity of essential internal services by emplloying a experienced electricine and helper to restore the existing / services to satisfactorily level of user/Engr in charge by using stores issued by the deppt all as direction.
Attending external water supply complaints in Zone 'A', 'B' and Zone 'C' for leakage/repair of water pipe line up to 40mm dia including replacement of unserviceable pipe fittings and arrest the water leakage in all respect and checking of water pressure in that area and tightening of all gate valve / pipe fittings/ pipe connections if found loose complete, all as specified and directed by Engr-in-Charge. Note :- (i) Complaints attended in one day shall deemed to be in one complaint. (ii) Minimum 01 technician and 01 helper to be provided by contractor to attend the complaints. (iii) All pipe fittings shall be measured separately under relavant item of sch 'A'. (iv) All T&P required at site shall be provided by contractor with out any extra cost. Note for Serial item No 1 to 4 :- (i) T & P including convence to reach door to door for attending the jobs will be provided by the contractor. (ii) Material will provided by department through maintenance cell and necessary salvage/ unused material deposit back to complaint cellincharge/ JE EM. (iii) The complaint slip will be collected from complaint cell incharge / EM by the contractor supervisor (iv) The area/ location of job will be all Md and OTM accn in ARO of AGE EM -I. (v) Scan coppy of EPF, ESIC will beprovided by the contractor at the time of bid at the time of bid submission otherwisebid will be rejected in tchnical bid. complaint not by contractor with in24 hours he will be liable for for penlalty / recovery of Rs per complaint. amount amount will be deducted from running payment / final bill
Supply only switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
Supply only switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
Supply only socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
Supply only socket outlet multipurpose 2 in 1, 3 pin, 5 and 15 flush Amps 250 V AC complete all as specified & directed.
Supply only Bell switch paino flush button type 5 Amp complete all as specified.
Supply only ding dong bell AC 230 V single pole complete all as specified and directed.
Supply only switch paino flush button type 5 Amp SP 2 way complete 250 V AC all as specified and directed.
Supply only step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Ampds 400 watts complete all as specified.
Supply only ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified.
Supply only lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
Supply only sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed Make Legrand/Schneider/ABB..
All as per item No 15 here-in-above but 12 way. Make Legrand, ABB & C&S
All as per item No 15 here-in-above but 6 way. Make Legrand, ABB & C&S
All as per item No 15 here-in-above but 4 way. Make Legrand, ABB & C&S
S&F in replacement sheet metal enclosures 240 volt, Single Door 2 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and out going complete all as specified and directed. Make Legrand/Schneider/ABB..
Supply only MCB DB sheet metal enclosure Single pole and neutral with a two pin and earth plug and socket complete with one Double pole MCB 20 amp, 240 volts complete all as specified. Make Legrand, ABB & C&S
Supply only sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed Make Legrand/Schneider/ABB.
Supply only MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed Make Legrand/Schneider/ABB...
Supply only MCB single pole and 240 volt 10 KA 5 - 32 Amp 'B' series conforming to ISI marked all as specified and directed.
Supply only MCCB thermal magnetic release 4 pole 125 Amp 50 Hz 415 volt with repturing capacity 35 KA complete all as specified.
Supply only MCCB thermal magnetic release 4 pole 63 Amp 50 Hz 415 volt with repturing capacity 16 KA complete all as specified.
Supply only plug top 3 pin 15 Amp in repair. ISI marked complete all as specified. Make Anchor/ Cona/ Plaza
Supply only modular switch 1 way 6A,1 module,230 volts complete all as specified and directed.
Supply only modular switch 1 way 16A,1 module, 230 volts complete all as specified and directed.
Supply only modular socket 6A-2/3 pin, 2 module, 230 volts all as specified and directed.
Supply only modular socket combination 16 A,6 pin,2 module ,230 volts all as specified and directed.
Supply only modular Fan step regulator, 120W,2 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame,1 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame,2 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame,3 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame,4 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame,6 module ,230 volts all as specified and directed.
Supply only modular white cover plate with frame, 8 module ,230 volts all as specified and directed.
Supply only Modular metal flush box 1/2 module
Supply only Modular metal flush box 3 module
Supply only Modular metal flush box 4 module
Supply only Modular metal flush box 6 module
Supply only Modular metal flush box 8 module
Supply only high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
Supply only Heavy duty PVC insulated multistrand Single Core copper conductor of Size 1.5 Sqmm. Make : Finolex/Ploycab/National.
Supply only Heavy duty PVC insulated multistrand Single Core copper conductor of Size 2.5 Sqmm. Make : Finolex/Ploycab/National.
Supply only Heavy duty PVC insulated multistrand Single Core copper conductor of Size 4 qmm. Make : Finolex/Ploycab/National.
Supply only service cable 10 sq mm twin core weather proof aluminium multistranded conductor cable PVC sheathed PVC insulated complete all as specified and directed.
All as per item No 47 here in above but 6 Sqmm 2 core complete all as specified.
Supply only copper flexible wire hoisted twin cord 23/0076 for connection of ceiling fan etc. complete all as specified. Make :- Finolex/Ploycab/Kalinga.
All as per item No 49 here-in-above but 40/0076 for tube light connection etc. Make :- Finolex/Ploycab/Kalinga.
Supply only PVC insulated copper cable of size 40/0.0076 multi standard 3 core. Make Plaza, National, RR Kabel, Shalimar.
Supply only Capacitor 2.5 mfd Make :- Epcos, Asain//Usha/Baja
Supply only Capacitor 3.5 mfd Make :- Epcos, Asain//Usha/Baja
Supply only Capacitor 4 mfd. Make :- Epcos, Asain//Usha/Baja
Supply only Plug Top 5 Amp 240 Volt AC. Make :- Anchor,Cona,
Supply only Split pins of galvanised iron 1/8" dia 2" long.
Supply only Body screw and blade screw of ceiling fan 1200 mm/1400 mm sweep.
Supply only Nut- bolts & washers,rubber reel with clamp complete set for hanging of ceiling fan.
Supply only heating element 1.5 KW 230 volts, ISI marked suitable for 25/50 ltrs geysers of instaiied at site (Make of Geyser :- Baja, Recold , Havells , Oriant, Crompton). as per sample/site requirement, Shape & size complete all as specified and directed by Engineer-in-Charge. Make :- Baja, Recold , Havells , Oriant, Crompton.
All as per item No 59 here-in-above but 2.0 KW complete all as specified.
Supply only Geyser assembly any type of hole (6/7/9) ISI marked suitable for 25/50 ltrs geysers of instaiied at site (Make of Geyser :- Baja, Recold , Havells , Oriant, Crompton). as per sample/site requirement, Shape & size complete all as specified and directed by Engineer-in-Charge. Make :- Baja, Recold , Havells , Oriant, Crompton, Theeta, Dashmesh, Indofors & Donfoss.
Supply only Indicator lamp for geyser complete all as specified. Make : - Theeta/Bajaj/Recold/ Dashmesh/Crompton.
Supply only Thermostat for geyser long type 11" in length ISI marked suitable for 25/50 ltrs geysers of instaiied at site (Make of Geyser :- Baja, Recold , Havells , Oriant, Crompton). as per sample/site requirement, Shape & size complete all as specified and directed by Engineer-in-Charge. Make :- Baja, Recold , Havells , Oriant, Crompton, Theeta, Dashmesh, Indofors & Donfoss.
Supply only Fusible plug made out of brass and lead complete all as specified. Make : Dashmesh/Theta/Newton
Supply only Geyser Pressure release valve spring loaded 15 mm dia complete ISI marked suitable for 25/50 ltrs geysers of instaiied at site (Make of Geyser :- Baja, Recold , Havells , Oriant, Crompton). as per sample/site requirement, Shape & size complete all as specified and directed by Engineer-in-Charge. . Make : Dashmesh/Theta/Newton
Supply only Rubber Gasket suitable size for 25/50 Ltr geyser.Make : - Theeta/Bajaj/Recold/ Dashmesh/Crompton.
Supply only Chromium plated copper connecting pipe 450 mm long with nuts and rubber washers suitable for 15 mm bore pipe. Make:- Polo/Havells/Prayag
Supply only PVC flexible connection Nylon braided with suitable threaded check nut with washer complete suitable for hot/ cold water 15mm dia alongwith threaded Brass nuts and washers 45 cm long. Make:- Polo/Havells/Prayag
S & F including grouting with nut & bolts sheet metal box of size 60cmx90cmx25 cm fabricated made out of 2 mm thick MS sheet and suitable of angle iron and M S flat and provn of 6 mm thick bakelite sheet for fixing of main switches and DBs with double locking arrangement incl one coat of red oxide primer and two coats of synthetic enamel paint incl making good disturbed surfaces and taking down the unserviceable of wooden boxes all aas specified and directed by Engineer-inp-Charge
Supply & Laying well burnt bricks, sub class 'B' brick laid breadth wise, along the cable in trenches after sand cautioning laid for UG cable protection complete all as specified and directed.
Supply and laying galvanised steel tubing 50 mm bore light grade laid in trenches or fixed to poles/walls etc for cable protection complete all as specified and directed.
Supply only rigid non-metallic PVC conduit 25 mm dia (External) exclusive of boxes (Junction /terminal) but inclusive of all tees, bends, elbows, reducers, ball mouths tubes ends and fixing for accessories such as couplers lock nuts, saddles pipe, hooks etc complete all as specified.
All as per item No 72 here-in-above but 20 mm dia.
All as per item No 72 here-in-above but 32 mm dia.
Supply only PVC junction box ( L to 4 way) 25 mm dia external.
All as per item No 75 here-in-above but 32 mm dia.
All as per item No 75 here-in-above but 20 mm dia.
Supply only for sun mica sheet 3 mm thick fixing size 250x200 mm directed by Engineer-in-Charge (Make Hylum/Cona/ISI marked).
All as per item No 78 here-in-above but 100x100mm size.
All as per item No 78 here-in-above but 300x250 mm size
All as per item No 78 here-in-above but 150 x 100 mm size
Supply only of 3 core 1.5 Sqmm copper conductor cable in existing pole incl making holes for cable entry and exist near to light fitting and junction box complete all as directed.
Supply only GI pipe fittings (ISI marked) of the following size :-
GI elbow 20 mm
GI elbow 25 mm
GI elbow 40 mm
GI nipple 20 mm x 2"
GI nipple 20 mm x 4"
GI nipple 20 mm x 6"
GI nipple 25 mm x 2"
GI nipple 25 mm x 4"
GI nipple 25 mm x 6"
GI socket 20 mm
GI socket 25 mm
GI socket 40 mm
GI reducing socket 15 x 20
GI reducing socket 20 x 25
GI reducing socket 25 x 15
GI reducing socket 40 x 25
GI reducing socket 40 x 20
GI union 15 mm
GI union 20 mm
GI union 25 mm
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts copper winding, double ball bearing with down rod , canopy, blades etc ncluding connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed. (Note: Old U/S fan shall be deposited to E/M store yard).
M&L for Cutting hole on the existing wall of round shape for fixing exhaust fan of 300mm sweep size complete with plastering the surface and matching with the existing surface complete all as specified and directed.
Supply and fix in replacement exhaust fan, steel body AC single Phase. 230V of size 300mm, 900 RPM, single phase, 230V AC with louver all as specified and directed 30 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR, or equivalent in Crompton/ Usha. (Note: Old U/S fan shall be deposited to E/M store yard).
Supply and fix in replacement exhaust fan, steel body AC single Phase. 230V of size 450 mm, 900 RPM, single phase, 230V AC with louver 3 mm sheet. including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent in Crompton /Usha. (Note: Old U/S fan shall be deposited to E/M store yard).
Supply, Fixing & Connecting in replacement wall mounted fan oscillating type 400 mm sweep single phase 230 Volt complete all as specified and directed.Make :- Havells/ Crompton/ Usha( Note: Old unserviceable Exhaust fan will be deposited in E/M store yard. )
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed. (Note: Old U/S geyser shall be deposited to E/M store yard).
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge for following:- Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two No two way switch
All as per item No 92 here-in-above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm complete all as specified.
All as per item No 92 here-in-above but Sheet metal enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm complete all as specified.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in existing PVC / Steel concealed conduit, and MS boxes/ cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge for following :- Note: The wiring to be done as per IE rule and maintain colour code accordingly
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two way switch
All as per item No 95 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm complete all as specified.
All as per item No 95 above but Sheet matel enclosure MCB DB with plug socket independent, with cable 4 Sq mm size, with earth continuity coductor of size 4 Sq mm complete all as specified.
M/L for point wiring with 2 single core FRLS/FR PVC insulated, unsheathed stranded copper conductor of size 1.5 sqmm in and including PVC casing & caping/conduit with teak wood boxes and 3mm thick plastic laminated sheet top cover for light/fan/socket controlled by one switch complete with 1.5 sqmm PVC insulated unsheathed multistranded copper conductor 1100 volts grade green colour for earth continuity all a specified and directed.
All as per item No 98 here-in-above but for one 5 Amp socket outlet independent complete all as specified & as directed by Engr -in-Charge.
All as per item No 98 here-in-above but for one 5 Amp socket outlet on the same board with other switches complete all as specified.
All as per item No 98 here-in- above but for one 15 Amp socket outlet independent with 2 run of cable of size 4 sq mm and one run of 2.5 sq mm cable as earth continuity complete all as specified and directed.
S&F in replacement modular switch 1 way 6A,1 module,230 volts complete all as specified and directed.
S&F in replacement modular switch 1 way 16A,1 module, 230 volts complete all as specified and directed.
S&F in replacement modular socket 6A-2/3 pin, 2 module, 230 volts complete all as specified and directed.
S&F in replacement modular socket combination 16 A,6 pin,2 module ,230 volts complete all as specified and directed.
S&F in replacement modular Fan step regulator, 120W,2 module ,230 volts complete all as specified and directed.
S&F in replacement Modular switch 2 way 6A1 module complete all as specified.
S&F in replacement Modular Bell push 6A 1 module complete all as specified.
S&F in replacement Bell Multi Music type complete all as specified.
S&F in replacement modular white cover plate with frame,1 module ,230 volts complete all as specified and directed.
S&F in replacement modular white cover plate with frame,2 module ,230 volts complete all as specified and directed.
S&F in replacement modular white cover plate with frame,3 module ,230 volts complete all as specified and directed.
S&F in replacement modular white cover plate with frame,4 module ,230 volts complete all as specified and directed.
S&F in replacement modular white cover plate with frame,6 module ,230 volts complete all as specified and directed.
S&F in replacement modular white cover plate with frame, 8 module ,230 volts complete all as specified and directed.
S&F in replacement modular metal flush box 1/2 module complete all as specified and directed.
S&F in replacement modular metal flush box 3 module complete all as specified and directed.
S&F in replacement modular metal flush box 4 module complete all as specified and directed.
S&F in replacement modular metal flush box 6 module complete all as specified and directed.
S&F in replacement modular metal flush box 8 module complete all as specified and directed.
S&F in replacement of sheet metal enclosure SPN with 3 pin earth metal plug and socket complete with one SPN MCB 20 Amps, 240 volts in repairs complete all as specified and directed by Engineer-in-Charge. Make L&T, ABB, Legrand, GE
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete al as specified.
S&F Bell switch paino flush button type 5 Amp complete all as specified.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F switch paino flush button type 5 Amp SP 2 way complete 250 V AC complete all as specified and directed.
S&F step type regulator socket type double module 5 step for ceiling fan 230 volts 6 Amp complete all as specified.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified.
M&L lamp holder insulated body with back plate suitable for angle and batten fitting complete all as specified.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. Make of PVC Wire: Havells/KEI/Finolex/L&T.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sqmm as earth wire upto common earth and connected to earth dolly complete all as specified & directed.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sqmm. (nominal area) drawing in existing PVC / Steel concealed conduit. and one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm. (nominal area) drawing in existing PVC / Steel concealed conduit. and one single core green colour PVC Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq mm. as earth wire upto common earth and connected to earth dolly complete incl taking out old unserviceable submain all as specified & directed.
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
S&F in replacement sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked all as specified and directed.
S&F in replacement MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed. Make: Legrand/Schneider/Simens/L&T
S&F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten)CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE) or equivalent in Crompton/ Eveready.
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make - Havells Cat No Edgelite or equilent in Philips/Wipro
S&F in replacement LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size Make:WIPRO CAT PART NO-LW07-141-XXX-57XXor equivelent , HAVELLS/CROMPTON/EVEREADY
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size.
Supply, Fixing and testing in replacement LED down lighter recessed mounted 2x2 feet 36W ultra modern designed LED luminaire which provide soft light and glair free symmetrical illumination suitable for grid ceiling and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on as per Havells Cat Part no: ENDURASLIMPROPLUS2x2PLR28/36WLED 840MOD or equivelent make of PHILIPs/ CROMPTON / EVEREADY all as directed by Engineer-in-Charge.
S & F high efficiency LED bulbs 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
S & F high efficiency LED bulbs 9 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
M&L in replacement GI bracket made out of 40 mm GI pipe medium grade bend for fabrication to shape as required length of pipe 1.2 mtr with necessary fixing arrangement by means of MS clamps 02 Nos not less than 50x6 mm MS flat duly painted, nuts, bolts and washer complete all as directed (Make TATA/JINDAL/Swastik).
Supply and Fixing Integral LED Bldg security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W or equivalent in EVEREADY including taking out old unserviceable street light fittings.
Supply and fixing of LED tube rod 18/20 Watts single or double sided connections polycarbonate complete incl making connection alteration in existing tube light fitting complete all as specified.
S&F in replacement of U/S Tamper Proof electronic single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 volt class 1.03 and class 2.05 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED indication of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type pvc box complete. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note: Old U/S Meter shall be deposited to E/M store yard). Make:- L&T/ Legrand/Secure/BHEL.
Supply and fixing in replacement LED Solar street light fitting 20 Watt including galvanized steel pole in built, lithium ion battery, solar panel, charge controller with dusk down sensor complete all as specified. (Excavation & earth work shall be measured separately
M&L for Cement concrete (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation and mass concrete for fixing poles etc complete all as specified and directed.
M&L for PCC (1:2:4) type B1 (using 20 mm graded crushed stone aggregate) for coping etc for pole including necessary Steel form work and finishing exposed faces of concrete smooth and even using extra cement all as specified and directed.
M & L in replacement for DK Thermoplastic cable junction boxes IP 65 with metric knockouts for cable entry, weather proof for outdoor installation and including glands and with 4 terminals for terminating one incoming and outgoing UG cable of size 6/10/16 sqmm 2/3.5/4 core and fixed to the Steel Poles by means of suitable size of clamps with nut and bolts and incl provn for fixing 01 nos of single pole MCBs 6-32 amps,10KA and MCB TPN 6-32 amps, 10 KA = 01 No inside the box and complete all as spcd and directed. Make :- Sintex / Hensel or as approved.
Material and labour in replacement of GI tubing medium grade, complete with all fittings for installation of post top Lantern fitting of 50 mm bore complete all as specified and directed.
Material and labour in replacement of GI tubing medium grade, complete with all fittings for installation of post top Lantern fitting of 40 mm bore complete all as specified and directed.
S&F LED decorative post top lantern for Garden light 40 watt IP 65 protection resistance to impact and corrosion glare, free and better uniformity milky version as per CG cat part No LPTO40CDL/ Bajaj model No. BGCTW4LEDWW or equivalent in Crompton/ Eveready including taking down old unserviceable post of lantern.
S&F factory fabricated bus bar chamber out door pedestal type made out of 2.0 mm thick CRCA sheet of size 750x500x400 mm duly painted with powder coating, simens grey/RAL fitted with four Nos aluminium bus bar of capacity 400 Amps duly mounted epoxy insulator , Cable connections of incoming and outgoing cables duly insulated PVC heat shrinkable sleeve 1.1 KV grade including one No MCCB, 200 Amps, 4 pole, 16 KA, with adjustable thermal setting Ics=100% Icu, including glands c/p lugs etc including 50x50x6mm angle iron frame 450mm height above ground level and 450mm below ground level, angle iron frame shall be embeded in PCC (1:2:4) type B 1 block of size 200x200x200mm complete all as specified and directed including taking out old unserviceable bus bar chamber.
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
All as per item No 160.00 here-in-above but using galvanised iron strip 32×6mm as earthing lead complete all as specified.
S&F in replacement aluminium strip 25x3mm fixed in ground,on wall, pole with epoxy based insulator for down conductor including drilling two Nos holes at each joint, one set of lead washers between strips two sets GI nut, bolt, washers one set of lead washers between strips two sets GI nut, bolts, washers gutties, screws etc
S&F air termination single pointed aluminium rod of 12mm dia 300mm long fixed to aluminium strip 25x3mm drilling nuts, bolts washers for resting/supporting of air terminals etc complete all as directed by Engineer-in-Charge.
Supply, laying, jointing and testing in replacement of underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size complete all as specified and directed.
All as per Item No 164 here-in-above but 16 Sq mm, 4 core complete all as specified
All as per Item No 164 here-in-above but 10 Sq mm, 2 core complete all as specified
All as per Item No 164 here-in-above but 6 Sq mm, 2 core complete all as specified
M&L for excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in any type of soil complete all as specified and directed.
M&L for returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for sand cushioning in trenches for protection of UG cable with riverbed sand laid dry in trenches before and after laying of cable, including well ramming and consolidation complete all as specified and directed.
Supply and fixing, grouting with nut & bolts sheet metal box of size 100cmx75cmx40 cm fabricated made out of 2 mm thick MS sheet and suitable of angle iron and M S flat and provn of 6 mm thick bakelite sheet for fixing of main switches and DBs with double locking arrangement incl one coat of red oxide primer and two coats of synthetic enamel paint incl making good disturbed surfaces and taking down the unserviceable of wooden boxes all aas specified and directed by Engineer-inp-Charge. Note- Materials taken as " supply only" in the BOQ shall be supplied and deposited to MES store yard of Engineer-in-charge and taken on ledger charge by him and shall be issued on proper issue voucher solely for the purpose of repair/ maintenance under this contract only.
Ansh Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .