Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.4 LAccepted-AOC 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹46.9 L+₹3.3 L (7.49%)Rejected-Finance | L2 | Rejected-Finance Not the lowest bidder | |
| 3 | L3₹47.2 L+₹3.5 L (8.12%)Rejected-Finance | L3 | Rejected-Finance Not the lowest bidder | |
| 4 | L4₹48.6 L+₹4.9 L (11.3%)Rejected-Finance | L4 | Rejected-Finance Not the lowest bidder | |
| 5 | L5₹49.1 L+₹5.5 L (12.6%)Rejected-Finance | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
30 Aug 2021, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
SPECIAL REPAIR FOR BLDG NO P-7 AND PROVISION OF RAIN WATER PUMP AT BARRACKPORE UNDER GE BARRACKPORE
2021_MES_467006_1
8531/E8
Open Tender
Civil Works
Item Rate
180 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹83,000
Yes
13 Sept 2021
11 Aug 2021
1 Sept 2021
11 Aug 2021
30 Aug 2021
25 Aug 2021
Amount
Demolition of brick work or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillar etc but excluding ashlars facing dressed stonework & precast concrete articles complete all as specified and directed.
Demolition of cement concrete (unreinforced) as in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (reinforced) in ground floor not exceeding 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking down cement plaster of any description on brick or stone or concrete surface of wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Taking down chowkats or frame (without taking off shutter from the frames) not exceeding 1.50 Sqm each complete all as specified and directed.
Taking down chowkats or frame with shutters (without taking off shutter from the frames) not exceeding 1.50 Sqm each and refixing in the same opening after easing and adjusting complete all as specified and directed.
Taking down chowkats with shutters (without taking off shutter from the frames) exceeding 1.50 Sqm and not exceeding 4.00 Sqm each complete all as specified and directed.
Taking down of shutter of any description exceeding 1 Sqm and not exceeding 2.0 Sqm each complete all as specified and directed.
Taking out of existing un-serviceable tarfelt / bituminous membrane including demolition of existing cement concrete/screed bed on roof and parapet of any roof height carefully by cutting chiseling or by any mechanical way, cleaning the surface by scraping, brooming, brushing etc and removing the rubbish from site complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description etc complete all as specified and directed.
Excavating in post holes (or similar holes) in soft /loose soil each not exceeding 0.5 cum, getting out, returning filling in and ramming earth or broken rubble mixed with earth around, iln layers not exceeding 25cm, watering and removing surplus soil to a distance not exceeding 50m and making good the surface complete all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points in soft/loose soil complete all as specified and directed.
M&L for broken stone or boulders hardcore of gauge not exceeding 63mm, deposited spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in surface channel and drains etc complete all as specified and directed.
M&L for plain cement concrete (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate), as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork complete all as specified and directed.
M&L for cement concrete (1:2:4) type C-1 (using 20mm graded crushed stone aggregate) as in coping, bed plates, kerbs or mud stops, top of chajjas, basement for water tank etc rounded or chamfered on edges including necessary form work finishing the surface even and fair with using extra cement complete all as specified and directed.
M&L for RCC (nominal mix) (1:2:4) type B1 (using 20mm graded crushed stone aggregate) used as in shelves and like etc complete all as specified and directed.
M&L for cutting out cracks to V-Section existing roofs or terracing cleaning out, wetting, grouting with cement & sand slurry (1:3) complete all as specified and directed.
M&L for cutting chases, in brick wall, pinning in and making good to facing where required and pointing in cement mortar (1:3), to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing etc and making good the disturbed surface, cutting not exceeding 10cm girth complete all as specified and directed.
M&L for cutting holes into or through brick walls in cement mortar or stone walls built in cement lime mortar or cement mortar to a depth of embedded portion exceeding one brick but not exceeding two bricks for inserting holdfasts and making good dismantled portion in cement concrete (1:2:4) Type B-1 as required complete all as specified and directed.
M&L for brick work with sub class 'B' bricks straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar (1:4) complete all as specified and directed.
Supply only integral water proofing compound liquid, ISI marked complete all as specified and directed.
M&L for forming jambs, etc. to openings (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work in cement mortar (1:6) complete all as specified and directed.
M&L for formwork to the soffits of suspended slabs such as roof slabs, floor slabs, shelves and similar work, not exceeding 200 mm thick (horizontal or sloping ) and making flat, rough finished surfaces of concrete complete all as specified and directed
M&L for second class hard wood in fillets, square, rectangular or triangular in section, clean swan, fixed with nails or brads, sectional area exceeding 13 sqcm but not exceeding 25 Sqcm complete all as specified and directed.
S&F for second class hard wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered put together with glue pinned at joints of second class hard wood etc complete all as specified and directed.
S&F for 35mm thick (factory made) plain, second class hard wood, framed, panelled shutters (three panels) with lock rails and panel of 12 mm veneered particle board with commercial veneering on both faces (BWR type), the size of rail and stile as per IS-1003 (Part-I) (larger size to be provided) klin seasoned and chemically pressure treated fitted to chowkats complete all as specified and directed.
S&F for 30mm thick second class hard wood glazed/ gauge & skeleton shutters (factory made), open rebated & prepared to receive glass, gauge etc. (with sash bars) edges of framing plain, chamfered or rounded, fitted with cut & mitered beads for securing glass etc. sizes of members of shutters as specified in SSR part-I, section-8, clause 8.24 (a) (larger size to be provided) complete all as specified and directed.
M&L for 12 mm thick medium density fibre board, exterior grade, fixed with screw/beading to aluminium frame work complete all as specified and directed.
S&F for 18/19 mm thick veneered finish prelaminated particle board fix in cupboard shelves & shutter interior grade, prelaminated in one side with decorative choice lamination solid core medium density general purposes, and other side white lamination fixed with screw including teakwood lipping all round complete all as specified and directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm thick plain colour PVC sheet reinforced with MS square tube as per specification and drawing complete all as specified and directed.
S&F for factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame at site as per clause 8 B.2.1 of MES schedule Part-II (2004) complete all as specified and directed.
S&F for aluminium extuded body door closer hydraulically regulated designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 850 Kg fixed as in repair complete all as specified and directed.
S&F for double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel (heavy duty) complete all as specified and directed.
S&F for floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (overall length of cover plate 140mm) complete all as specified and directed.
S&F for ball catches with 8mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and directed.
S&F for auto closing hydraulic hinges fixing with particle board with approved size and design complete all as specified and directed.
S&F for 250 mm aluminum alloy, anodised , sliding door bolt with hasp and staple (bolt type ) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded section or cast aluminum alloy and fixed complete all as specified and directed.
S&F for 200 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium, anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S&F for 150 mm long aluminium anodised extruded alloy handle fabricated type complete all as specified and directed.
S&F for 75 mm long aluminium anodised extruded alloy handle fabricated type as in repair complete all as specified and directed.
S&F for 75 mm size extruded brass handle, fabricated type, polished complete all as specified and directed.
S&F for 100 mm long aluminium anodised hasp & staple safety type including hinge pin, bolt to hinge plate etc complete all as specified and directed.
S&F for 100 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for 75 mm long cold rolled mild steel butt hinges, medium weight complete all as specified and directed.
S&F for continuous piano type hinges mild steel bright finish or electro galvanised, size of flap (when open) 30mm as in repair complete all as specified and directed.
S&F for 25mm dia aluminium, powder coated (wood colour finished), single curtain rod (wall thickness not less than 1mm) including funnels etc as in repair complete all as specified and directed.
S&F for aluminium bracket (heavy duty), powder coated of best quality as approved suitable for fixing 25mm bore curtain rod fixed in wall complete all as specified and directed.
S&F for stainless steel wire cloth, 0.36 mm nominal dia of wire & average width of aperture 1.40mm & fixed with stainless steel wire staple complete all as specified and directed.
S&F for 75 mm mortice lock vertical type of brass with 4 lever completed all as specified and directed.
S&F for 100 mm mortice lock vertical type of brass with 4 lever as in repair completed all as specified and directed.
M&L for TMT bars 10 mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for TMT bars 6mm to 8mm dia and over cut to length bent to shape as required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F for mild steel hold fast made out of flat iron (25mm x 3mm or equivalent size) including tarring or coal tar black paint and with drilling necessary holes etc conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed.
M&L for mild steel framed work such as grills, gratings, etc. with ends of bars shouldered and/or forged into spikes; framed guard bars; barred iron doors; ladders, railings, framed brackets, walk ways, frame work of water tank and similar work conforming to Fe-290-0 Gde-E-165 complete all as specified and directed.
S&F for rolled mild steel roof trusses (framed) and purlins, rafters crane gantries, rails, heavy brackets etc including distance pieces, cleats, angle, tee etc including necessary cutting , welding etc complete Fe-410W (Gde E-250) quality 'A' complete all as specified and directed.
S&F for joist, channel, flat iron, angle or tee sections, fixed independently, without connecting plates etc (cut to ordinary lengths i.e. within 20mm of the length indicated) of Fe 410-W (Gde E-250) quality A complete all as specified and directed.
S&F for steel windows with side hung shutters (gauged) including projection type hinges with steel handle, frame, steel peg stay, complete without glazing bars, dovetailed or welded to receive wiremesh after and including taking down existing unserviceable steel window complete all as specified and directed.
S&F for steel ventilators with top hung double shutters (glazed & gauged) including box type hinges with steel handle, frame, steel peg stay, complete with glazing bars (weight not less than 44 Kg/Sqm), dovetailed or welded to receive wire mesh/glass after and including taking down existing unserviceable steel window complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminum frame (powder coated) for doors , windows, ventilators with one or more rebates (sliding & fixed type) including jointing cleat for fixing etc complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminium door shutters (powder coated), aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. including locking arrangement, roller complete all as specified and directed.
S&F for anodised (powder coating of minimum thickness 50 micron) aluminium window/ventilators shutters, side hung type without sash bar, aluminum section weighing 0.55 Kg/m, including necessary joining cleat, glazing clips, rubber neoprene packing, hinges type B-21 100 mm long (02 Nos), peg stay 150mm long (01 No), anodised aluminium snap beading, screws etc complete locking arrangement, roller complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws after and including dismantling of existing sheet complete all as specified and directed.
S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet of 0.50mm thick of any colour as approved by GE having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws after and including dismantling of existing sheet complete all as specified and directed.
M&L for applying evenly a coat of oil based bitumen primer confirming to IS-3384 on roof, canopy, chajja, parapet (vertical surface etc) @ 0.40 Litre / Per Sqm by the same membrane manufacturer of density 250C, 0.87 to 0.89 litre and viscosity 70-160 cps after proper cleaning the roof surfaces (horizontal/vertical) and providing APP based polymeric membrane minimum weighing 3.6 Kg/Sqm and minimum 3mm thick reinforced with polyester non wove fabric (weight not less than 150 gms / sqm) laid on primed surface with side over lap of 100 mm and end overlap of 150 mm, using bitumen torch or by LP gas torching and sealing all joints etc and ensuring complete thermo fusing and applying one coat of aluminum paint @100ml/Sqm over it all as per manufacturer's instructions complete all as specified and directed.
M&L for 100mm thick PCC (1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in subbase of floor complete all as specified and directed.
M&L for 75mm thick PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) as in plinth protection/floor including finishing the cement concrete surface even and smooth without using extra cement complete all as specified and directed.
M&L for 50 mm thick cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in floor/paving etc finished even and smooth without using extra cement complete all as specified and directed.
M&L for 18-20 mm thick granite slab (of any type) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the of granite stone including grinding and polishing over and including 15 mm thick screed bed of cement mortar (1:6) complete all as specified and directed.
M&L for non skid (joint free) ceramic coloured tiles of 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match with shed of tiles over and including 15mm thick screed bed or bedding layer of cement mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for vitrified light shade (shade as approved) ceramic tiles (ultra charge) 10mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 Sqm in floors etc set over and including 15mm screed bed in cement mortar (1:6) and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L for glazed ceramic coloured tiles in vertical surface of size 450 mmX 350 mmX7 mm thick or equivalent size set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering of cement mortar (1:4) complete all as specified and directed.
M&L for 20-22mm thick machine cut kota stone slab flooring (pre-mirror polished) over and including 20mm thick screed bed of cement mortar (1:6), laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for pre-polished coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy type), set, jointed and pointed in neat cement slurry in floors with grey cement and pigments over and including 20 mm thick cement screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size with grey cement and pigment confirming to IS 15658-2008 (M-35 grade) over in and including 40mm thick compacted sand cushioning complete all as specified and directed.
M&L for forming construction joint 30mm deep x 10mm wide filled with sealing compound Grade 'A' complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:3) on ceiling, chajja etc surface finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick in cement mortar (1:4) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick cement mortar (1:3) to sunken portion of slab with using water proofing compound as per manufacturer's instructions, finished even and smooth without using extra cement all as specified and directed. (NOTE: WPC shall be measured and paid separately)
M&L for rendering 15mm thick on fair face of brick works or concrete surfaces of walls cement mortar (1:4) mixing with WPC as per manufacturer's instructions, finished the surfaces even and smooth without using extra cement complete all as specified and directed. (Note : WPC will be measured and paid separately)
M&L for rendering 15mm thick in cement mortar (1:6) on brick work or concrete surfaces of wall, finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 20mm thick in cement mortar (1:4) as screed on concrete surfaces of roof as levelling course mixed with WPC as per manufacturer's instructions complete all as specified and directed. (Note : WPC shall be measured and paid separately)
M&L for applying three coats of white wash on wall surface including preparation of new plastered surface complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3mm thick wall care putty on old decorated plastered surface of wall after and including complete removal of existing treatment and preparation of surfaces complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on wall after preparation of newly plastered surfaces of walls complete all as specified and directed.
M&L for applying two coats of oil emulsion distemper over a coat of alkali resistant primer over and including applying 3 mm thick wall care putty on ceiling as per site condition after preparation of newly plastered surfaces complete all as specified and directed.
M&L for preparing surfaces of steel and iron work, new or old treating small articles such as strip, covers, gully gratings, hold fast ends of post, beads of chowkats etc area tarred not exceeding 0.1 sqm and treated with tar or coal tar black paint complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer after preparation of new steel surfaces of any description over 10cm width or girth complete all as specified and directed.
M&L for applying two coats of synthetic enamel paint over a coat of pink primer after preparation of new wooden surfaces of any description over 10 cm girth or width complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described complete all as specified and directed.
M&L for applying one coat of synthetic enamel paint after preparation of old painted wooden surfaces of any description, not otherwise described, over 10cm in width or girth complete all as specified and directed.
M&L for applying two coats of acrylic exterior emulsion paint over one coat of acrylic primer on old decorated surfaces after complete removal of existing treatment including preparation of surfaces of wall, cornices by wire brushing, rubbing down etc complete all as specified and directed .
M&L for writing letters or figures (block, roman, italic or Indian) not exceeding 30cm high after cleaning and preparation of existing surfaces complete all as specified and directed.
M&L for writing stops, commas, short lines dashes, hyphens, bracket etc after cleaning the existing surface complete all as specified and directed.
S&F for 3.0mm thick sheet glass ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm each pane after and including hacking out old borken glass (any thickness and size, quality or description from wooden/metal frame etc) complete all as specified and directed.
S&F for 3mm thick figured glass, pin head type and glazing with oil putty in square not exceeding 0.5 sqm each pane complete all as specified and directed.
S&F for 5.5mm thick sheet glass panes, ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F for 5.5mm thick sheet glass panes, ordinary quality and glazing with oil putty or fixed with bead/glazing pins in squares not exceeding 0.50 sqm in each pane complete all as specified and directed.
S&F for 15mm dia bib taps, fancy type, cast copper alloy with crutch or butterfly handles, screwed down, screwed for iron pipe or for brass ferule, chromium plated with long screw type fixed as in repair complete all as specified and directed.
S&F for 15 mm bore stop valve, fancy type chromium plated , cast copper alloy screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in repair complete all as specified and directed.
S&F for 15 mm bore angular stop valve , fancy type chromium plated with long shank and cup (concealed type) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions as in reapir complete all as specified and directed.
S&F for 15mm dia pillar taps, cast copper alloy with capstan heads, chromium plated, fancy type, screwed down high pressure, with letter 'HOT' or 'COLD' with long screwed shanks & fly nuts, screwed for iron pipes complete all as specified and directed.
S&F for brass chromium plated toilet paper holder fixed to walls with chromium plated brass screw as in repair complete all as specified and directed.
S&F for brass chromium plated tubular towel rail, 20mm dia, D-type, 60cm long between flanges as in repair complete all as specified and directed.
S&F for 20mm dia gun metal gate valves with iron wheel head screwed both ends for iron pipes or for unions pipes, fixed as in repair complete all as specified and directed.
S&F for 15mm bore wall mixer 3-in-1 system fancy type chromium plated cast copper ally with provision for hand shower and overhead shower complete with 115 mm long bend pipe, connecting legs & wall flange (without hand & over head shower) as in repair complete all as specified and directed.
S&F 15mm bore wall mixer L-bend (provision of OH shower) fancy type chromium plated cast copper alloy complete with 115mm long bend pipe on upperside connecting legs and wall flange as in repair complete all as specified and directed.
S&F for flexible tube 8mm dia and 1.5m long with nuts for hand shower fixed with wall mixer complete all as specified and directed.
S&F for CP wash basin mixer for mixing hot & cold water screw down for iron pipe including necessary connection pipe from stop cock as in repair complete all as specified and directed.
S&F for CP over head shower multi flow with out arm of 125mm dia with flange joints including fixing to steel pipe or union of 15mm dia as in repair complete all as specified and directed.
S&F for CP round double rain shower without arm with flange, joints including fixing to steel pipe or union of 15mm dia as in repair complete all as specified and directed.
S&F for CP shower arm 20mm dia and 225mm long for wall mounted shower with flange joints including fixing to steel pipe or union of 15mm dia as in repair complete all as specified and directed.
S&F for towel rack with lower hanger (stainless steel) with hook 600 mm long fixed with and including chromium plated brass screws and wooden/plastic cleat as in repair complete all as specified and directed.
S&F for corner glass shelf ( with bracket) of size 300mm as in repair complete all as specified and directed.
S&F for chromium plated towel ring fixed with and including brass screws and wooden/plastic cleats (Minimum weight 90gms) as in repair complete all as specified and directed.
S&F for 32mm dia waste fittings, brass chromium plated for glazed ware sinks, basins etc. with long screwed shanks & fly nuts, flanged end bedded in red lead cement & other end fixed as in repair complete all as specified and directed.
S&F for 15mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 20mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
S&F for 25mm dia tubes (medium grade) galvanised, with all fittings and fixed complete to walls and ceilings or laid in floors, wall etc (surface or concealed type) after and including taking up or down existing steel tubing complete all as specified and directed.
Refixing old steel tubings & connections in new or old position (wall, ceiling, floor, trench etc.) for 15 mm bore pipes with new fittings etc after and including taking up or down existing steel tubing and cleaning the same for reuse complete all as specified and directed.
S&F for 15 mm dia PVC connection pipe of length 450 mm with PTMT nuts complete all as specified and directed.
S&F for shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (minimum weight 300gms) complete all as specified and directed.
S&F for 20mm dia ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe & fixed (minimum weight 210 gms) as in repair complete all as specified and directed.
S&F for 10 Ltrs capacity, PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete with all internal accessories and fixed to wall and jam nuts on both sides, PVC flush pipe 32mm dia 90cm long fixed properly to inlet of WC and making good to disturbed surfaces of wall or floor as in repair complete all as specified and directed.
S&F for 1000 Ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) multi layer (three layer), ISI Marked hoisted and fixed in position with cover of tank with its locking arrangement, making hole for inlet, outlet and overflow connection including dismantling / taking down old PVC water tank, ball valve etc complete all as specified in SSR Part-I and directed.
S&F for vitreous china wash basin, white, flat back, size 630 X 450 mm, excluding taps, chain and plug and porcelain stopper but including waste pipe, brackets and cutting for and pinning in ends of brackets or erecting stand as in repair complete all as specified and directed.
S&F for vitreous china wash down water closet pan (pedestal pattern) white with P or S trap (excluding flushing cistern & flush pipe) including connection to trap & to flushing pipe, anti-syphonage pipe & seat cover etc. including making good to floor as in repair complete all as specified and directed.
S&F for vitreous china squatting pan 'Orissa' pattern, size 580x440mm white, with integral foot rests with P or S trap (excluding flushing cistern and flush pipe) including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete including making good to floors with PCC bedding (1:5:10) type E2 using 40mm nominal brick ballast and connection to trap with cement mortar, and making good to floor as in repair complete all as specified and directed.
S&F for chromium plated health faucet with 15mm dia CP tube of 1.2 mtr long as in repair complete all as specified and directed.
S&F for sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm as in repair complete all as specified and directed.
S&F for 125mm dia grating with waste hole , fancy type, chromium plated as in repair complete all as specified and directed.
S&F for stainless steel kitchen plate rack fancy type fixed with plug washer and or including fixing cantilever brackets and overall size 900X800 mm as in repair complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in trenches or in floor as in repair complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in floor as in repair complete all as specified and directed.
S&F for 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) bends any radius complete all as specified and directed.
S&F for 110mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
S&F for 75mm bore PVC(SWR) junction single, (single T) equal or unequal providing access door complete all as specified and directed.
M&L for PVC (SWR) 'P’ trap of 115/110mm bore complete complete all as specified and directed.
M&L for PVC (SWR) 'S’ trap of 115/110mm bore complete all as specified and directed.
S&F for 75mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal provided with access door complete all as specified and directed.
S&F for 110mm bore PVC (SWR) branch pieces, single (single Y) equal or unequal provided with access door complete all as specified and directed.
S&F for 110 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 75 mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F for 32 mm bore low density polyethylene pipes (LDPE) of pressure rating 6kgf/cm2 fixed complete to wall or in floors etc. as in outlet pipe for WHB, urinal etc. as in repair complete all as specified and directed.
M&L for cutting into existing manhole for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( 1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 smooth finished and reforming benching as required dia of pipe 150 mm complete all as specified and directed
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces by applying white/ colour wash/distemper after applying of putty for smooth finish surface complete all as specified and directed.
M&L for point wiring complete with 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC Conduit 20 mm dia medium grade (MMS) and including cutting, chasing work at any height and all accessories concealed in walls / roofs / floors / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for conduit entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of modular top cover , blanking plate as per numbers of switch modules, modular switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures modular accessories of suitable modules and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces by applying white/colour wash/distemper after applying of putty for smooth finish surface complete all as specified and directed for the following:- (Note:- All necessary accessories such as modular box, top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and cost of the same shall be deemed to be included in quoted rate only.)
One light point controlled by one switch .
One fan point controlled by one switch and one regulator.
One exhaust fan point controlled by one switch .
One 5 pin 6 amps socket point controlled by one 6 amps switch on independent board .
One 5 pin 6 amps socket point controlled by one 6 amps switch on same board .
One bell/buzzer point controlled by one bell push.
One light point controlled by two Nos two way switches .
All as per Item No.155.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.50 sqmm complete all as specified and directed for the following :-
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on independent board.
One 6 pin 6/16 amps socket outlet point controlled by one 16 amps switch on same board.
S&F for modular switch 16 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 10 Amps, single pole, 1 way, 1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular switch 10 Amps, 2way, single pole,1 module, 240V, AC, ISI Marked complete all as specified and directed.
S&F for modular socket 6 Amps, 2/3 pin combined 2 module, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular socket 6/16 Amps, 6 pin combined shutter socket, 2 module with light indication, 240 V, AC, ISI marked complete all as specified and directed.
S&F for modular bell push, 6Amps, 1 module, single pole, 1 way, 240V, ISI Marked complete all as specified and directed.
S&F for modular fan regulator, electronic, stepped type (01 to 4/5), 100 to 120 Watts, 2 module, 240Volts, AC, ISI marked complete all as specified and directed.
S&F for red colour lighting indication lamp 6 Amps, single pole, 240volts, AC, 50 Hz suitable for 1 module, ISI Marked complete all as specified and directed.
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed.
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 10 watts complete all as specified and directed. (Make: Philips/Havells/Crompton Greaves as approved)
S&F for ceiling rose, three terminal, PVC/polycarbonate body, ISI marked complete all as specified and directed.
S&F for decorative box type 20 -22watt LED fitting with and including LED T-8 tube light 20 watt of fire retardant engineering grade complete with all accessories internally pre-wired, connecting up with and including three core sheathed flexible copper conductor cable of required size and including mounted on PVC/Wooden round/square blocks-02 Nos complete all as specified and directed. (Make - Havells Cat No REGALBATTENT8UPTO1 x 22WDSBSWH/Crompton Greaves cat No : DMLN1LT8-16 for fittings and make - Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRAE2.01213T8SSTL20WLED865SPC as approved for LED lamp as approved)
S&F for 10 watt LED light fitting mirror type with high out put diffuser 2 feet, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. (Make: Havells/Bajaj/Crompton as approved)
S&F for decorative type surface mounted 1X6 watts LED light fitting with LED lamps including fixing arrangements at any height with nuts, screws and washers and connected to ceiling rose and connecting up with and including three core sheathed flexible copper conductor cable of required size complete all as specified and directed. (Make: Crompton cat No.LCDEP-06-CDL / Havells cat No EDGEPRORDDLR6WLED857S as approved)
S&F for 36 watt LED street light fittings IP-65/66 pressure die cast housing LED lamp aluminium compact high power LED street light with heat resistant toughened glass with LED lamp and necessary connection with suitable size copper cable complete all as specified and directed . (Make : Crompton Greaves Cat No LSTS-36-CDL-M/ Bajaj Cat No BRTFG 36W LED as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 40mm dia medium grade bent to shape of 1.2 mtr long as directed including clamps made out of 30 mm x 6 mm flat iron for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
S&F for powder coated sheet metal enclosure acrylic door 415 volts AC,TPN distribution board 8 way suitable for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB TPN/DP, and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete all as specified and as directed. (Make:- Legrand cat No. 5076 82 8 way / Hager Cat No.VYT08GH/ L&T Cat No. DBTPN008GD as approved)
S&F powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 200amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 200Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08D / L&T Cat No.DBSPN008GD as approved)
S&F for suitable for flush mounting sheet steel enclosure metal clad plug and socket including MCB SP 20 Amps, 10KA 'C' series, 240 Volts complete all as specified and directed. (Make : Legrand Cat No. 5078 11/Havells Cat No. DHDPUSN020/L&T Cat No. DBMPS220SD as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete all as specified and directed (Make: L&T /Havells/Legrand as approved)
S&F for MCB, SPN, 40 Amps to 63 Amps, 10 KA, 'C' series, AC, 240 volts, ISI marked complete all as specified and directed. (Make: L&T /Havells/Legrand as approved)
S&F for MCCB, 100 Amps, 4 pole, 25KA breaking capacity Icu at 415 Volt with thermal magnetic release, 50 Hz complete all as specified and directed. (Make - L&T Cat No. CM91712OOKOOG or equivalent of Legrand Cat No. 4200-55 /Hager Cat no. HHA101U as approved)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically (earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised iron wire of 4mm dia upto 7.5m including testing consider in this item).
S&F for heavy duty type exhaust fans AC single phase 230/240 V of size 300 mm sweep, 900 RPM with louver and necessary connection, testing including cutting the existing wall surfaces of brick/stone masonry and making the hole of any height for fixing the exhaust fan with nuts, bolts and washers after grouting in PCC including mild steel jalli and wooden frame for avoid insects after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make : Havells model No Turbo Force SP 300mm-900RPM or equivalent model of Crompton Greaves as approved)
S&F for ceiling fan of size 1400 mm sweep, high speed, single phase, 240Volts, AC, 50Hz, as approved colour and including hanging GI hook with necessary suitable MS clamps and connecting cable three core 0.75 sqmm round PVC sheathed from ceiling rose to fan connector and testing after and including taking down of existing exhaust fan and deposit to MES store yard complete all as specified and directed. (Make:- Havells model No. Samraat or equivalent model of Crompton Greaves/Usha/Bajaj as approved)
M&L for XLPE insulated, LT armoured electric cable with aluminium stranded conductor 1100 volts grade, cross-sectional area 50 sqmm, 3.5 core laid in trenches/pipes/ducts/wall/borings with necessary cable lugs and glands, nuts, bolts and washers etc and testing complete all as specified and directed. (NOTE: Excavation/earth work, sand cushioning, cable cover/brick shall be measured and paid separately if required)
Excavation in trenches for laying under ground cable, foundation and erection of poles and stays in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming in layers not exceeding 25cm soil all as specified and directed.
Removing surplus excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting points as in soft/loose soil all as specified and directed.
M&L for sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep including required watering and consolidation after laying and stretching the cable complete all as specified and directed.
M&L for brick covering with width equal to length of brick as protection to cable with well burnt sub class ‘B’ bricks of size 250mm x 125mm x 75mm laid dry flat complete all as specified and directed .
M&L for sub main wiring complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit shall be measured as one unit)
M&L for sub main wiring complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of required size medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including chease cutting and filling the same with cement mortar and finished with putty and making good the disturbed surfaces to match with existing surface as required for concealed work complete all as specified and directed . (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity, one run of PVC conduit shall be measured as one unit)
S&F for water storage heater (geyser) of 25 ltrs capacity, vertical type with copper inner tank, 240 volts, AC, 50Hz and fixing arrangement on wall including providing hole fastners-04 nos, hot & cold water PVC pipes 15 mm bore approximate 600 mm long -2 Nos, chromium plated brass stop cock 15 mm bore -01 No and including necessary plumbing work, tesing and taking down existing old unserviceable geyser and depositing in MES Store yard complete all as spcified and directed. (Make: Havells/Crompton Greaves /Recold as approved)
M&L for 40mm dia pipe (medium grade) made of galvanised iron in any length including embedded in wall both ends duly welded mild steel hold fast at both ends of GI pipe including providing PCC work (1:2:4) type B-0 (using 12.5 mm graded crushed stone aggregate) complete all as specified and directed.
Supply, installation, testing and commissioning of high pressure single cylinder, 4 stroke, 5HP diesel Engine pump set including with trolley mounted complete all as specified and directed. (Make: Kriloskar or equivalent as approved)
S&F for 100 mm dia PVC flexible pipes ISI marked (heavy duty) complete all as specified and directed. (Make:Supreme/Prince as approved)
S&F for strainer for suction 100mm dia complete all as specified and directed.
PUNAM ENTERPRISE
S S ENTERPRISE
NANDY ENTERPRISE
R N CHATTERJEE
BHASKAR SUPPLY AGENCY
SENCO
N S CONSTRUCTION
CHATTERJEE CONSTRUCTION AND SUPPLIERS
BEE ROMEN
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .