Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹23.6 L+₹4.8 L (25.8%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹24.2 L+₹5.4 L (28.7%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance BEING L3 | |
| 4 | L4₹27.5 L+₹8.7 L (46.4%)Rejected-Finance SHAMAL BECHAR S CHAWL SIDHANATH ROAD B H KHANDERAO MARKET VADODARA 390 001 GUJARAT | VADODARA | VADODARA | GUJARAT | 390001 | L4 | Rejected-Finance BEING L4 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
29 Sept 2021, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIRS TO ROOF, FALSE CEILING AND MISC WORKS AT MAKARPURA AFS BARODA
2021_MES_472410_1
8640/E8
Open Tender
Civil Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
3 documents required · 3 mandatory
₹500
GE AF BARODA
₹50,000
Yes
25 Nov 2021
2 Sept 2021
1 Oct 2021
2 Sept 2021
29 Sept 2021
17 Sept 2021
3 Sept 2021 - 8 Sept 2021
Amount
M&L for taking down existing water proofing treatment (WPT) of any description from roof surfaces alongwith tiles if any incl desmantling of existing PCC/plaster surfaces and roughening of concrete surfaces cleaning and wahsing down the surfaces with water and removing rubbish to out side MD land as directed by Engr-in-Charge. Note :- Felts and cement plaster/tiles etc shall be measured as one layer only.
M&L for 15 mm thick screed bed or bedding layer in CM 1:4 over roof surfaces without using extra cement with using water proofing compound (WPC) as directed Note:- WPC shall be measured and paid seperately under respective item.
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm confirming to IS-3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick weight not less than 3.5kg/sqm (modified bituminous water proofing membrane ) with plain finish with polystere base reinforcement, sealing all over with lap of 75mm in length side and 100mm on width side of membrane by torching the same and including applying a coat of bituminous aluminium paint @ 100 gms/sqm all as per manufacturer instructions complete all as specified and directed .
Note:- (a) Rate quoted deemed to be inclusive of cleaning of surface to be treated properly to receve the primer and all as directed by the Engr-in-Charge. (b) Necessary guarantee certificate shall be given by contractor for 10 years from the date of completion of work. (c) APP membrane treatment shall be done firstly at corners and junction of parapet wall 30cm on verticle position and 30cm on horizontal position shall be done with proper attention and work carried out by authorised applicator only. Main portion of roof treatment shall be commenced only on completion of corners/ edges/ junctions. (d) APP membrane shall be taken upto outside of the parapet wall to an extent of 150mm minimum. (e) Ensure while laying the treatment no bulging on surface/voids shall be found and proper care/attention be given for the treatment. (f) If any work executed at site without any authorised applicator, the same shall be rejected and no payment shall be made. (g) Contractor shall produce the certificate from the manufacturer for the authorised applicator before commencement of work.
M&L for cement concrete type B-0 1:2:4 (using 12.5mm graded stone aggregate) (in roof slabs) laid to slope 1:30 in padding for WPT over roof slab complete all as specifed and as directed.
M&L for providing cement concrete type B-0 1:2:4 (using 12.5mm graded stone aggregate) in cover fillets at junction of roof slabs and parapets wall, RCC chajja coping and similar work as directed by Engr-in-charge with using WPC complete. Note : WPC will be measured and paid separatly
Disconnecting existing water tanks (PVC/RCC) exc 250 ltr & n.exc 500 ltr capacity, setting aside (or lowring if required ) for repairs, cleaning etc and hoisting if required , reconnected including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc complete all as specified and directed.
Disconnecting existing water tanks (PC/RCC) exc 500 ltr & n.exc 1000 ltr capacity, setting aside (or lowring if required ) for repairs, cleaning etc and hoisting if required , reconnected including cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc. complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 1000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position including taking down the existing one complete all as specified and directed.
M&L for brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections, including cleaning for re-fixing or removal to store all as specified and directed
Taking up or down 25mm bore steel tubing and connections, including cleaning for re-fixing or removal to store all as specified and directed
Refixing old steel tubing 15mm bore and connections in new or old position (Walls, ceiling, floors, etc.) all as specified and directed
Refixing old steel tubing 20mm bore and connections in new or old position (Walls, ceiling, floors, etc.) all as specified and directed
Refixing old steel tubing 25mm bore and connections in new or old position (Walls, ceiling, floors, etc.) all as specified and directed
S&F 15mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25mm bore Tubes,'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F (in repair) 20mm size Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s) and fixed all as specified and directed
S&F (in repair) 25mm sizeBall valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight 25mm-455gms) and fixed all as specified and directed
S&F (in repair) 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F (in repair) 25 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F in repair 20mm GI Nipple suitable for HDPE water tank. (Minimum weight 20mm45gms ) all as specified and directed
S&F in repair 25mm GI Nipple suitable for HDPE water tank. (Minimum weight 25mm- 65gms) all as specified and directed
Taking down cement plaster on brick or stone walls etc including raking out joint, hacking for key, scrubbing down with water etc, complete all as specified and as directed
M&L for rendering in two layer (i.e) CM 1:6, 10mm thick as first layers and CM 1:4, 5mm thick as 2nd layer wtih water proofing compund on stone masonry surfaces or surfaces other than fair face of brick or on concrete surfaces finished even and smooth without using extra cement complete all as specified and directed. Note : WPC shall be measured and paid seprately under respective item.
M&L preparation of newly plastered or unplastered surfaces of wall surfaces and applying two coats of cement base paint over alkali resistant priming coat on walls upto 4th floor including necessary form work, cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed by Engineer-in-Charge. (Colour/shade shall be as directed by GE).
M&L for complete removal of existing treatment by scraping down completely on brick walls/stone walls/concrete surfaces plastered or unplastered thoroughly, rubbing down, washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of Cement Base Paint (Colour or shade as approved by GE) over alkali resistant priming coat as per manufacturers instruction complete on wall upto 4th floor including necessary form work cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed by Engineer-in-Charge.
M&L preparation of newly plastered or unplastered wall surfaces and applying Two coats of exterior ACRYLIC Emulsion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy including necessary steel scafolding upto 4th storey complete all as specified and directed.
M&L for complete removal of existing treatment on wall/ceiling surfaces by scraping down completely on brick/stone walls/concrete surfaces thoroughly, rubbing down washing with water to the entire satisfaction of Engineer-in-Charge and applying two coats of exterior ACRYLIC Emulsion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy including necessary steel scafolding upto 4th storey.complete all as specified and directed by Engineer-in-Charge.
M&L for 5 mm thick rendering on ceiling surfaces of concrete in cement mortar 1:3 finished even and smooth (without using extra cement) complete all as specified and as directed
M&L, Preparation of newly plastered ceiling surfaces and applying three coats of white wash , complete all as specified and as directed
M&L, Preparation of old plastered ceiling surfaces and applying two coat of white wash complete all as specified and as directed
Supply only Integral waterproofing compound
S&F in repair 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F in repair 75mm dia PVC (SWR) bends any radius complete all as specified and directed.
S&F in repair 110mm dia PVC (SWR) bends any radius complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
M&L false ceiling work of Anodised aluminium snap grid frame work ceiling grid system UNLOCK comprising of main runner 34mm x 24mm x 0.35mm, cross tee 24mmx 24mm x 0.40mm and GI suspenders 8mm dia fixed to ceiling and fixing mineral fibre acoustics ceiling borad of size 600mm x 600mm x 12mm thick complete all as specified and instructions of manufacturers complete all as specified and directed.
Dismantling floor, hearth or including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for Cement concrete tiles 20cm x 20cm x 20mm thick, m a c h i n e pressed; set jointed and pointed in neat cement slurry in floors, and cut and polished with grey cement and no pigment incl 10 mm thick screed bed or bedding layer in CM 1:4 without using extra cement for screed bed with water proofing compound (WPC) as directed by Engr-in-Charge.complete all as specified and directed. Note : WPC shall be measured and paid seprately under respective item.
Chanda Construction Co.
M/S Badri Electicals
M/s. RAMESH NARHARI VALEKAR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .