Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.5 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹38.4 L+₹3.0 L (8.33%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹42.6 L+₹7.1 L (20.0%)Rejected-Finance JAVERI BUNGALOW AREA KAVERI HOTEL LINE NH PORBANDAR 360 575 | PORBANDAR | GUJARAT | 360575 | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹74,000
Closing Date
25 Jun 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Maj Yogender Singh
GE Navy Porbandar Tija Mile Porbandar
PROVISION OF PAVED AREA AT LEFT APPROACH WING OF INS SARDAR PATEL NEAR MAIN SECURITY GATE OF NAUSENA BAGH AND PROVISION OF TOILET, SOAKAGE WELL IN NOFRA AND INS SARDAR PATEL PORBANDAR
2021_MES_441957_2
9080/PBR/E8
Open Tender
Civil Works
Item Rate
180 days
Porbandar
Please refer Tender Documents
7 documents required · 7 mandatory
₹500
Garrison Engineer Navy
₹74,000
Yes
3 Jul 2021
5 Jun 2021
28 Jun 2021
5 Jun 2021
25 Jun 2021
12 Jun 2021
5 Jun 2021 - 11 Jun 2021
60 days
Amount
Surface excavation n. exc. 30 cm deep and averaging 15 cm deep and getting out in hard/dense soil including cutting of bushes, saplings and cutting trees not exc. 30m girth etc complete all as specified and directed.
Precast M-35 Grade factory made kerb stone of size as directed with one edge rounded, set and jointed with CM 1:6 including excavation and earthwork and fixing of the stone and packing around complete all as specified and directed by Engineer-in-Charge.
Hardcore of Broken stone or boulders of gauge n. exc 63mm, deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed
PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete or as in sub base (75 mm thick) complete all as specified and directed.
80 mm thickness, M-40 Grade Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of complete (with grey cement and pigment) over and including 50 mm thick sand cushioning complete all as specified and directed.
Removing excavated rocks to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified.
Preparation of newly plastered surfaces of precast kerb stone and applying two coats of synthetic enamel paint complete all specified and directed.
Excavation over areas n.exc 1.5 m deep & getting out in hard dense soil. Complete as specified and directed.
Excavation over areas n.exc 1.5 m deep and getting out in soft/ disintegrated rocks. Complete as specified and directed.
Excavation over areas exc 1.5 m deep and n exc 3.00m and getting out in soft/ disintegrated rocks. Complete as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in any type of soil complete as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc and getting out in Soft/disintegrated rock complete as specified and directed.
PCC 1 : 3 : 6 Type C2 ( 40 mm graded crushed stone aggregate) as in foundation and mass concrete. complete all as specified and directed.
Cement concrete 1:3:6, type C-2 using 40mm graded crushed stone aggregate as in concrete bed to drain pipes 150 mm internal dia including packing under and haunching against the sides of pipe after they are laid tested, complete all as specified and as directed.
Reinforced concrete pipes, class NP3 of size 150mm bore, laid and jointed complete with collars complete as specified and directed.
Stone masonry walling or squared walling in cm 1:4, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Precast reinforced cement concrete M-30, using 20mm graded crushed stone aggregate as in baffle wall including use & waste of form work for fair finished surfaces complete all as specified and directed.
RCC M-30, using 20 mm graded stone aggregate as in lintel including necessary use and waste of formwork for fair finished surface of concrete. Complete as specified and directed.
MS framed work such as grills, gratings, screen or rungs etc with ends of bars shoulders or riveted or forged in to spikes, framed guard bars etc and similar work conforming to Fe 410-0 or Fe 310-0 complete as specified and directed.
Reinforced cement concrete M-30, using 20mm graded stone aggregates as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
use and waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exc 200mm thick for fair finish surfaces. Complete as specified and directed.
Precast reinforced cement concrete M-30, using 20mm graded stone aggregate as in cover slab for manholes etc including use & waste of form work for fair finished surfaces complete all as specified and directed.
Precast reinforced cement concrete 1:2:4 type B-1, using 20mm graded stone aggregate as in window or door cills, bressummers, steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, anchorage blocks, bonders (for stone walling). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weathering's, throating etc. and setting in mortar complete with joints to match including use & waste of form work for fair finished surfaces complete all as specified and directed.
Rendering 15mm thick on concrete work in CM 1:4 finished the surfaces even and smooth using WPC @ 3% of cement wt (WPC paid separately) complete all as specified and as directed.
Supply only integral water proofing compound. Complete as specified and directed.
Mild steel CRS bars 10mm dia and over , cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
Returning filling in soil, including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as directed.
Returning filling in soft/disintegrated rock including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as directed.
Removing excavated soils not exceeding 50 M and depositing where directed at a level not exceeding 1.5 M above the starting point complete as specified and directed.
Stone masonry walling or squared walling in cm 1:6, brought upto courses using dressed same size Porbandar stone of superior quality complete all as specified and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide completed all as specified and directed.
Mild steel CRS bars 8mm dia and over as in stirrups spacer and binder, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
40mm thick cement concrete 1:2:4 type B1 (20 mm graded agg) as in floor Complete all as specified and directed.
Non skid ceramic joint free floor tiles 7-8mm thick (Square / rectangular) area of each tile exceeding 0.06 sqm but n.exc 0.11 sqm set and jointed in neat cement slurry and pointed in coloured cement over and including bedding layer 15 mm thick in cement mortar 1:6 complete all as specified and as directed.
Glazed ceramic tiles, coloured (light colour as approved), of size 300 x 200 x 7mm thick on vertical surfaces such as in skirting / dado etc set and jointed in cement slurry over 10mm thick rendering in cement mortar (1:4) and pointed in white cement with pigment to match the colour of tiles complete all as specified and as directed.
Rendering 10 mm thick on fair face of stone or concrete surfaces in CM 1:6 finished even and smooth without using extra cement. Complete as specified and directed.
Rendering 5mm thick in cement mortar (1:3) on fair faces of soffit of slabs, sides soffit of roof beam. Complete as specified and directed.
Preparation of plastered or unplastered new surfaces of walls and applying two coats of oil bound distemper over a coat of primer complete all as specified and directed .
Preparation of newly plastered surfaces of Ceiling and applying three coats of white wash
Anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified
Powder coated Anodised aluminium window and ventilator shutters, fixed type without sash bar, including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
4mm thick sheet glass, ordinary quality and glazing with neoprene gasket in aluminium windows / vent complete all as specified and directed.
75mm thick PCC 1:3:6 , type C-1 using (20mm graded stone aggregate) as in plinth protection finished even & smooth without using extra cement making 10mm wide joints at every 3m interval and at every corner, filled with mixture of bitumen and sand (1:1) complete all as specified and directed.
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supplying & fixing in opening as per specification & drawing complete all as specified and as directed.
Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, as per specification & drawing complete all as specified and directed
Stainless steel butt hinges medium grade 100mm complete all as specified and as directed.
25mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
20mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
16mm (outer dia) CPVC pipes, UV stabilised, SDR 11 pressure bearing capacity 28.12 kg/sq.cm @ 23 C ,leak proof, tough, rigid and suitable, fixed to walls with clamps / ceiling / concealed in wall including cutting chases and making good, or laid in trenches / jointed with sealant solvent leak proof including all fittings elbow, Tee, Socket, Reducer, Bushing, Step over head bends, End cap, End pugs, union, tank nipple and special fittings (brass insert threaded) like male, female treads, adapters, brass tee & reducers, male brass threaded adaptor, female brass threaded adaptor, flange including making Suitable size of brass threaded terminal to match the CP/PTMT plumbing fittings and interconnections as required for internal and external water supply applications complete all as specified and as directed.
CP Pillar taps 15 mm bore, cast copper alloy, with capstan heads screwed down high pressure, with or without lettered `Hot' or `Cold' with long screwed shanks & fly-nuts, screwed complete all as specified and as directed.
Vitreous China wash hand basin white flat back, size 550mm x 400mm, cutting for and pinning in ends of brackets Including waste pipe, brass waste coupling, 32 mm bore chromium plated brackets, making all connections complete all as specified and directed.
Vitreous China wash down water closet (Pedestal pattern) white with concealed S-Trap/P-trap, 360mm wide, 390mm high and 415 to 445mm long at top including fixing bolt Plastic water closet seat cover white closed pattern with flat bottom and cover and mild steel chromium plated hinging device including connection to drain (or outgoing pipe) and to flushing pipe, antisyphonage pipe, etc , complete all as specified and directed.
Angular stop valve brass 15mm bore, Capstan head chromium plated, with wall flange, fancy type screwed down high pressure with long screwed shanks and fly nuts, screwed for iron pipe, complete all as specified and directed.
Fancy type bib taps, chromium plated cast copper alloy 15mm bore with crutch screwed down, complete all as specified and directed. Complete all as specified and as directed
450 mm long PVC connection suitable of 15 mm nominal bore pipe complete with brass chromium plated unions and rubber washers. The weight of brass coupling nuts shall not be less than 40 grams complete all as specified and directed.
PVC low level flushing cistern 10 litres capacity valve less symphonic action type, ISI Marked white with inlet, ball valve, float and handle including brackets complete all as specified and directed.
Vitreous china urinal bowl type, flat back, size of 465 mm x 355 mm x 265 mm white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) complete including providing and fixing plugs ,bedding urinal against wall in CM 1: 2 securing urinal to plug with and including 60 mm long brass screws, pointing around urinal back in cement etc. complete all as specified and as directed.
S&F low density polyethylene pipes 32 mm dia as in waste pipe complete all as specified and directed.
150mm grating round/square of PTMT (Minimum weight 100 gm) openable (two piece type) complete all as specified and directed.
300mm long (Length of Bolt in mm) Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
40mm thick Damp proof course to horizontal or vertical surfaces including necessary formwork in PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate (WPC Shall be measured separately) complete all as specified and as directed.
PVC (SWR) pipes, 75mm bore, single socketed, 4 Kgf per Sqcm pressure, in any length with rubber ring joints, laid in trenches/ fixed to floor/wall/ ceiling with clamps complete all as specified and as directed.
PVC (SWR) bends any radius of nominal bore 75 mm with rubber ring joints,complete all as specified and directed
PVC (SWR) junction single, (Single T) equal or unequal of nominal bore 75mm with rubber ring joints, complete all as specified and directed
600 mm long PVC connection suitable of 15 mm nominal bore pipe complete with brass chromium plated unions and rubber washers. The weight of brass coupling nuts shall not be less than 40 grams complete all as specified and directed.
PVC (SWR) pipes, 110mm bore, single socketed, 4 Kgf per Sqcm pressure, in any length with rubber ring joints, laid in trenches/ fixed to floor/wall/ ceiling with clamps complete all as specified and as directed.
PVC (SWR) bends of nominal bore 100mm with rubber ring joints,complete all as specified and directed.
PVC (SWR) branch piece, double (double Y), equal or unequal 110mm dia with rubber ring joints,, complete all as specified and directed
PVC (SWR) floor trap 75mm dia with grating including jointing with solvent cement complete all as specified and directed
PVC (SWR) gully trap 125/110 mm, setting & jointing with solvent cement complete all as specified and as directed.
110mm bore PVC (SWR) vent cowl complete all as specified and directed.
Rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top) 1000 Litre capacity, hoisted and fixed in position, with lid, tounge nipple for inlet, outlet connections etc. complete all as specified and directed
20mm ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed min. wt. 20mm-210gm complete all as specified and as directed.
Point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC concealed conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc including all cutting / chases etc in walls complete all as specified and directed.
(a) One light point/bell point controlled by one switch
(b) One ceiling fan /Exhaust fan controlled by one switch & regulator
(c) One 3 pin socket point 5 Amps on same board
Ceiling rose surface Bakelite, 65x50mm, 3 terminals complete all as specified and directed.
Switch piano flush type 5/6 Amps single pole one way 230 Volts complete all as specified and directed.
Socket Outlet 2 in 1, 3 pin 5 Amps flush type 230 Volts complete all as specified and directed.
Lamp holder, PVC / Polycarbonate type angular shape with back plate suitable for batten fitting complete all as specified and directed.
10-Watt LED Linear Lamp CDL (White) with polycarbonate body and aluminium heat sink, warm white luminiscence complete all as specified and directed by Engineer - in - Charge. Make:Bajaj 10-Watt LED Ivora Linear Lamp CDL (White) or equivalent model of make specified in appx 'B' hereinbefore.
Sub main wiring concealed with two runs of single core 4 Sqmm (Nominal area) cable PVC insulated FRLS multistrand unsheathed copper conductor cable including 1100 V grade, ISI marked with copper conductor drawing into rigid non-metallic PVC concealed conduit complete with including one run of 2.5 sqmm (nominal area) single core PVC insulated multistrand unsheathed FRLS copper conductor as earth wire and duly connected to all common earth point, complete all as Specified and directed by Engr-in-Charge. (Conduit and cutting chasing shall be measured and paid separately).
Rigid non metallic conduit of size 20 mm bore with all accessories, concealed in or fixed to wall as directed for sub main wiring including all cutting chasing and making good disturbed surface complete all as specified and directed.
Exhaust fan 300mm sweep AC, 240 volts connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable complete all as specified & directed by Engr in charge.
Sheet metal enclosure, single door, single pole and neutral, AC, 240 volts, 4way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing, complete all as directed by Engineer - in - Charge.
MCB SP 6-32 Amps,10 KA breaking capacity 'B' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
MCB DP-10 Amps,10 KA breaking capacity 'C' Curve suitable 230 V,50 Hz for lighting and other domestic load complete all as specified and directed by Engineer - in - Charge.
Fine dry river sand cushion in trenches for cable protection with a layer of sand 8cm thick before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed. NOTE: - Only compacted thickness will be measured and paid.
Precast concrete cable cover unreinforced, ISI marked class LV types 2 flat size 250mm x 150mm x 40mm having minimum average breaking load 200KG, complying IS:5820-1970 made of concrete used of grade M-20, laid flat in trenches over the cable with the length of concrete cover perpendicular to the direction of the cable length, adjacent / abutting each other complete all as specified.
XLPE insulated armoured (under ground) heavy duty electric cable with standard aluminium conductor 1100 Volts grade of cross sectional area 10 sqmm 2 core laid in trenches/ducts/through pipes /in floor road/along the pole etc complete all as specified and directed.
Supply, laying, jointing and testing GI tubing 25mm bore medium grade with all fitting, laid in trenches, or fixed to walls, floors, ceiling or laid in trenches etc. complete all as specified and directed.
Gun-metal, ball valve, disc type with iron wheel, screwed both ends for iron pipe, ISI marked of size 25mm bore complete all as specified and as directed.
RUDRAAY CONSTRUCTION
OM ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .