The Executive Engineer (O&M), Olpad (R) Division
Erection and labor work of supply, laying, testing & commissioning of 11/22 KV Underground XLPE cable (XLPE cable will be supplied by DGVCL) with cable end termination & straight through jointing kit (To be supplied by contractor) on ARC basis and ARC for Erection of HT/LT line and TC work and other maintenance work and O/H XLPE Cable under All scheme for All sub division under Olpad (R) division.
367329
DGVCLDOLPD/0158/11/2026 Approved Date: 18-11-2026 18:21
Open
Electrical - All
Works
Surat
3 documents required · 3 mandatory
₹5,900
SURAT
₹80,000
19 Nov 2026
19 Nov 2026
19 Nov 2026
7 Dec 2026
19 Nov 2026
180 days
Name of Work : Work of ARC for Erection of HT/LT Line and TC work and other maintenance work and O/H XLPE Cable and ARC for Erection and labour work of supply,
laying, testing & commissioning of 11/22 KV Underground XLPE cable (XLPE cable will be supplied by DGVCL) with cable end termination & straight through jointing kit (To be
supplied by contractor) under All scheme for All sub Division under Olpad Rural Division.
CAPITAL WORK LABOUR RATES FOR FY 2024-25 (WITHOUT GST)( Part -A)
Sr. No. Item Code Item Unit FY 2024-25
HT TAPPING FROM THE EXISTING POLE INCLUDING FIXING OF CROSS ARMS, CLAMPS
ANTI-CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND
1 9926000001 PAINTING OF FABRICATED MATERIALS AND NUMBERING COMPLETE WITH COST OF No.
PAINTS AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
ERECTION OF PSC POLES OF 8 *200 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
2 9926000002 DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED MATERIALS No.
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF STEEL POLES OF 9 TO 11 METERS INCLUDING EXCAVATION OF PIT
AND REFILLING OF EARTH, FIXING OFCROSS ARMS, TOP FITTING CLAMPS ANTI-
CLIMBING DEVICES, DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING
OF STEEL POLE, FABRICATED MATERIALS USED ON THE POLEAND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SET AND EARTHING.
ERECTION OF STEEL POLE OF 13 METERS FOR RAILWAY CROSSING ON BG/MG/NG
LINE FOR 0.400/11/22KV OVERHEAD LINES I.E INCLUDING EXCAVATION OF PIT &
REFILLING OF EARTH, FIXING CROSS ARMS, TOP FITTING CLAMPS,ANTI-CLIMBING
4 9926000004 DEVICES DANGER BOARD, INSULATORS ETC. COMPLETE AND PAINTING OF STEEL No.
POLES, FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH
COSTOF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 8 METERS 200 KG PSC POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
5 9926000005 BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS No.
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.(WITHOUT
ERECTION OF DOUBLE POLE STRUCTURE OF 9 TO 11 METERS.STEEL POLE
INCLUDING EXCAVATION OF PITS & REFILLING OFEARTH, FIXING OF CHANNELS,
SUPPORTING ANGLES, CLAMPS,ANTI-CLIMBING DEVICES DANGER BOARDS,
6 9926000006 INSULATORS ETC.COMPLETE & PAINTING OF POLES,FABRICATED MATERIALSUSED No.
ON THE POLES AND NUMBERING WITH COST OF PAINTSAS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.(WITHOUT
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH, HG FUSES
OF 8 MTRS 200 KG PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH,FIXING OF CHANNELS SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
7 9926000007 DEVICES, DANGER BOARDS, INSULATORS,DOFUSES ETC. COMPLETE AND PAINTING No.
OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COSTOF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDINGOF ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES,
9 TO 11 METERS STEEL POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, FIXING OFCHANNEL, SUPPORTING ANGLES, CLAMPS, ANTI-CLIMBING
8 9926000008 DEVICES , DANGER BOARDS, INSULATORS, ETC. COMPLETE AND PAINTING OF POLES No.
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET
AND EARTHING.(WITH AB SWITCH)
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METER,200KG PSC POLE METERS POLES INCLUDING EXCAVATION OF PITS AND
REFILLING OF EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE, FIXING
9 9926000009 OF CHANNELS, SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, No.
ANTICLIMBING DEVICES DANGER BOARDS, CONDUCTOR AND CABLE WIRING
ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS USEDON THE POLES AND
NUMBERING WITH COST OF PAINT AS PER STANDARD SPECIFICATION BUT
EXCLUDING ERECTION OF GUY SETS AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE WITH MOUNTING OF AB SWITCH,HG FUSES
TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX 9 TO 11 METERS
STEEL POLES INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH CARTING OF
TRANSFORMERS FROM STORE TO SITE, FIXINGOF CHANNELS SUPPORTING ANGLES,
BRACING, CROSS ARMS,CLAMPS, ANTICLIMBING DEVICES, DANGER
BOARDS,CONDUCTOR AND CABLE WIRING ETC. COMPLETE AND PAINTING OF POLES
FABRICATED MATERIALS USED ON THE POLES AND NUMBERING AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTIONS OF GUY SETS AND EARTHING.
ERECTION OF GUY SET INCLUDING EXCAVATION OF PITS & REFILLING OF EARTH AS
PER STANDARD SPECIFICATION WITH STAY CLAMPS, STAY WIRE, ANCHOR ROD,
TURN BUCKLE, EYEBOLT, GUY INSULATOR, CEMENT CONCRETE BLOCK ETC. BUT
EXCLUDING CONCRETING.
CONCRETING OF POLES, GUYS, ETC. INCLUDING COST OF CEMENT SAND METAL
12 9926000012 (1:2:4) AND WATER ETC. AS PER STANDARD SPECIFICATION.(cement Should be 53 CMT
grade) used for Concreting.
ERECTION OF COIL TYPE EARTHING INCLUDING COST OF COAL,SALT ETC. BUT
WITHOUT COST OF GI WIRE AS PER STANDARD SPECIFICATION(20kg solt+20kg coal)
ERECTION OF GI PIPE/CI PLATE TYPE EARTHING INCLUDINGCOST OF COAL SALT ETC.
BUT WITHOUT COST OF PIPE/GIPLATE GI WIRE AS PER STANDARD
SPECIFICATION.(20kg
ERECTION OF STREETsolt+20kg coal)
LIGHT FIXTURE COMPLETE WITH CLAMPS, BRASS NIPPLE,
BRASS HOLDER TECK WOOD BUSH,REFLECTORS FUSE, WIRING ETC. AS PER
STRINGING SPECIFICATION BUT EXCLUDING AAA
OF(30mm2)ACSR/34MM@,55MM2 COST OF MATERIALS.
CONDUCTOR for ALL TYPE OF ONE
CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR 11/22KV & LT LINES INCLUDING FIXING COND
17 9926000017 OF INSULATORS, BINDING JUMPERING ETC.
STRINGING OF GI WIRE 8 SWG INCLUDING BINDING JUMPERING ETC. PER
PROVIDING SINGLE PHASE SERVICE CONNECTION WITH PVC 2.5/4MM2 TWIN CORE
CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING OF METER
WITH METER EARTHING COMPLETE WORK AS PER STANDARD SPECIFICATION BUT
EXCLUDING COST OF MATERIALS.
PROVIDING THREE PHASE 4 WIRE SERVICE CONNECTION WITH PVC 4MM2/10MM2
FOUR CORE CABLE FROM TERMINAL POLE TO METERING POINT INCLUDING FIXING
OF METER WITH METER EARTHING COMPLETE WORK AS PER STANDARD
SPECIFICATION BUT EXCLUDING COST OF MATERIALS.
ADDITIONAL COST FOR EXCAVATION OF PIT IN HARD ROCK AREA FOR ERECTION OF
POLE/ GUY ETC. AS PER STANDARD SPECIFICATION OVER & ABOVE NORMAL COST
20 9926000020 COVERED AGAINST EXCAVATION OF PIT UNDER NORMAL SOIL FOR ERECTION OF No.
POLE,GUY, DOUBLE POLE STRUCTURE EARTHING WITH THE APPROVAL OF
SUPDT.ENGINEER.
21 9926000021 PROVIDING GUARDING TO HT LINE ON ROAD/ RAIL CROSSING. MTR
22 9926000022 PROVIDING GUARDING OF LT LINES ON ROAD/RAIL CROSSING. MTR
23 9926000023 LT LINE TAPPING- SINGLE PHASE No.
24 9926000024 LT LINE TAPPING- THREE PHASE No.
Stringing/LAYING OF OVER HEAD LT CABLE FOR ROAD CROSSING,HT LINE CROSSING
AND TELEPHONE LINE CROSSING ETC.(PER SPAN)
ERECTION OF SINGLE POLE STRUCTURES WITH , HG FUSES,TRANSFORMERS,
LIGHTENING ARRESTOR, DISTRIBUTION BOX. ON 8 METERS 200 KGAND PSC POLE
INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH, CARTING OF
TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS, SUPPORTING
26 9926000026 ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES DANGER No.
BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING OF
FABRICATED MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF PAINT
AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS AND
ERECTION OF SINGLE POLE STRUCTURES WITH MOUNTING OFAB SWITCH , HG
FUSES,TRANSFORMERS, LIGHTENINGARRESTOR, DISTRIBUTION BOX. ON 9 to
METERS RSJ POLE INCLUDING EXCAVATION OF PITS AND REFILLING OF EARTH,
CARTING OF TRANSFORMERS FROM STORES TO SITE, FIXING OF CHANNELS,
27 9926000027 SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTICLIMBING DEVICES No.
DANGER BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND PAINTING
OF FABRICATED MATERIALS USED ON THE POLE AND NUMBERING WITH COST OF
PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OFGUY SETS
ERECTION OF PSC POLES OF 10 *270 KG INCLUDING EXCAVATION OF PIT AND
REFILLING OF EARTH, FIXING OF CROSS ARMS, TOP FITTING CLAMPS ANTI-CLIMBING
28 9926000028 DEVICES, INSULATORS ETC. COMPLETE AND PAINTING OF FABRICATED MATERIALS No.
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SET AND EARTHING.
ERECTION OF DOUBLE POLE STRUCTURE OF 10 METERS 270 KG PSC POLES
INCLUDING EXCAVATION OF PITS & REFILLING OF EARTHING, FIXING OF CHANNELS,
SUPPORTING ANGLES,CLAMPS, ANTI-CLIMBING DEVICES DANGER
29 9926000029 BOARDS,INSULATORS ETC.COMPLETE AND PAINTING OF FABRICATED MATERIALS No.
USED ON THE POLES AND NUMBERING WITH COST OF PAINT AS PER STANDARD
SPECIFICATION BUT EXCLUDING ERECTION OF GUY SETS AND EARTHING.(WITHOUT
STRINGING OF 100MM2 ACSR/100MM2 AAAC CONDUCTOR FOR 11/22KV & LT LINES
INCLUDING FIXING OFINSULATORS, BINDING JUMPERING ETC.
STRINGING OF DOG CONDUCTOR FOR 11/22KV & HT LINES INCLUDING FIXING OF
INSULATORS, BINDING JUMPERING ETC.
ERECTION OF DOUBLE POLE STRUCTURES WITH MOUNTING OF AB SWITCH, HG
FUSES, TRANSFORMERS, LIGHTENING ARRESTORS, DISTRIBUTION BOX. OF
METERS 270 KGAND PSC POLES INCLUDING EXCAVATION OF PITS AND REFILLING OF
EARTH, CARTING OF TRANSFORMERS FROMSTORES TO SITE, FIXING OF CHANNELS,
32 9926000032 SUPPORTING ANGLES,BRACINGS CROSS ARMS CLAMPS, ANTI-CLIMBING No.
DEVICES,DANGER BOARDS, CONDUCTOR AND CABLE WIRING ETC.COMPLETE AND
PAINTING OF FABRICATED MATERIALS USED ON THE POLES AND NUMBERING WITH
COST OF PAINT AS PER STANDARD SPECIFICATION BUT EXCLUDING ERECTION OF
GUY SETS AND EARTHING.
DISMENTALLING OF 8 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
33 9926000033 STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL No.
DISMENTALLING OF 10 MTR PSC POLE WITH CREDITING OF FABRICATION AT STORE &
34 9926000034 STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL No.
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITH
TRANSFORMER) WITH CREDITING OF FABRICATION & TRANSFORMER AT STORE &
STACKING OF POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL
DISMENTALLING OF TRANSFORMER CENTRE (8 MTR PSC POLE) (WITHOUT
36 9926000036 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE & STACKING OF POLE No.
SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
STRINGING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND TO
PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
38 9926000038 CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND KM
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
STRINGING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE
STRINGING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM INCLUDING FITTING OF ALL
ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF CROSS
ARM, BINDING TO PIN INSULATOR,PREPARING SHACKLE POINT,JUMPERS ETC. AS
REQUIRED AND DIRECTED BY ENGINEER IN CHARGE
STRINGING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM INCLUDING FITTING
OF ALL ACESSARIES I.E. SPECIAL DESIGN SUSPENSION / TENSION CLAMP, FIXING OF
CROSS ARM, LT SHACKLE INSULATOR ETC. FOR FIXING OF MESSENGER WIRE AND
TO PROVIDE SERVICE CONNECTION ON AERIAL BUNCH CABLE BY INSULATED
PIERCEING CONNECTORS THROUGH SERVICE CONNECTION BOX COMPLETE AS
REQUIRED & DIRECTED BY ENGINEER IN CHARGE.
DISMENTALING OF RSJ (9/11 METER) POLE AND CREDITING THE OLD MATERIAL TO
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITHOUT
43 9926000043 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTALING OF TRANSFORMER CENTER ON 10MTR,270KG PSC POLE(WITH
44 9926000044 TRANSFORMER) WITH CREDITING OF FABRICATION AT STORE AND STACKING OF No.
POLE SAFELY ON ROAD SIDE OR CREDITING TO DEPARTMENTAL STORE
DISMENTLING OF 11KV ABC OF 3*95 SQ MM +80 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTLING OF 22 KV ABC OF 3*70 SQ MM +95 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES AND FABRICATION TO DEPARTMENTAL STORE
DISMENTALING OF LT ABC OF 1*35 SQ MM + 1*25 SQ MM AND CREDITING FITTING OF
ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
DISMENTALING OF LT ABC OF 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM AND CREDITING
FITTING OF ALL ACESSARIES TO DEPARTMENTAL STORE.
RESTRINGING OF ALL TYPE OF CONDUCTOR (EXCEPT DOG CONDUCTOR) FOR
11/22KV & LT LINES INCLUDING FIXING OF INSULATORS, BINDING JUMPERING ETC.
RESTRINGING OF DOG CONDUCTOR FOR 11/22KV HT LINES INCLUDING , BINDING
LABOUR CHARGE FOR THE INSTALLATION OF NEW DTR METER. (METER WILL BE
PROVIDED BY DGVCL)
LABOUR CHARGE FOR THE REPLACEMENT OF DTR METER AND OLD METER SHOULD
BE CREDITED TO SDN STORE. (METER WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR PROVIDING CT COIL FOR DTR METER CONNECTION. (CT COIL
WILL BE PROVIDED BY DGVCL)
LABOUR CHARGE FOR REPLACEMENT OF CT COIL FOR DTR METER CONNECTION
55 9926000055 AND OLD CT SHOULD BE CREDITED TO SDN STORE. (CT COIL WILL BE PROVIDED BY PER CT
LABOUR CHARGE FOR FIXING OF MMB FOR DTR METER (MMB WILL BE PROVIDED BY
LABOUR CHARGE FOR REPLACEMENT OF DTR METER BOX. (METER WILL BE
PROVIDED BY DGVCL)
PROVIDING / REPLACEMENT OF 1.5 SQ MM 10 CORE COPPER CABLE 3.5 METER
(CABLE TO BE PROVIDED BY AGENCY)
LABOUR CHARGE FOR PROVIDING/RECONNECTION OF TERMINAL CONNECTION WITH
59 9926000059 TERMINA
PROPER SIZE OF LUGS. (LUGS COST IS BORNE BY AGENCY)
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-
60 9926000060 FORMA REPORT SHOULD BE SUBMITTED TO SDN OFFICE.(* ONLY IF ALL PARAMETER PER DTR
OF VOLTAGE, CURRENT & LOAD AS SHOWN IN PER-FORMA IS FILLED) AS PER THE
INSTRUCTION OF ENGINEER IN-CHARGE.
LABOUR CHARGE FOR THE SPOT READING OF DTR METER WITH DETAIL SURVEY OF
DEFECT IF ANY. A DULY SIGN COPY BY SURVEYOR PERSON OF AGENCY IN PRO-
FORMA REPORT SHOULD BE SUBMITTED TO SDN OFFICE. (DULY FILL PER-FORMA IN
FAULT CONDITION IN WHICH READING PARAMETER IS NOT SHOWN IN METER)
INSTALLATION OF DTR METER INCLUDING METER BOX, PROVIDING & FIXING OF 1.5SQ
MM SINGLE STRAND 10 CORE ARMOURED COPPER CABLE (3.5METER), TERMINATION
IN METER & COIL ETC.(METER, METER BOX, C.T./P.T. COIL WILL BE PROVIDED BY
INSTALLATION OF DTR METER INCLUDING METER BOX, TERMINATION IN METER &
63 9926000063 COIL ETC. (WITHOUT 10CORE COPPER CABLE) (METER, METER BOX, C.T./P.T. COIL No.
WILL BE PROVIDED BY DGVCL)
Binding of messanger Conductorat with a distance not more than 0.75 mtr with 6 turns minimum
on XLPE Cable with single strand binding wire (including cost of binding wire)
Supply and Installation of 11/22 kV Distribution Transformers HT Terminal protector (UV
65 9926000086 Resistance) with using 95/120/150 sq.mm long barrel aluminum lug. (1Set = 3 Nos i.e. on R, Y, PER SET
Supply & Installation of HT EPR Tap on 11/22 kV Distribution Transformer with replacement of
bare conductor by HT ABC conductor (DO bottom side to transformer) after removal of semi
conductor by HT ABC (6 inch both side). HT ABC to be supplied by DGVCL. (1Set = 3 Nos i.e.
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-
67 9926000088 Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 2000 mm Electrode Length as NO
per the Tender Specifications and Drawing. (All Materials Will Be Supplied By Agency)
Supply, Installation, Testing and Commissioning of Maintenance Free, Ready Capsule, Pipe-In-
68 9926000089 Cage (Pic) Type, Earth Electrodes for HT Feeder Pole Having 3000 mm Electrode Length as NO
per the Tender Specifications And Drawing. (All Materials Will Be Supplied By Agency)
Supply and Installation of 25 X 3 mm GI Strip having hot dip- galvanized-zinc coating of 80-100
microns without any joints or welding. Both the end of the GI strip should be connected with GI
nut bolts and required fabrication work for giving separate earthing connections to
(1) Neutral of the transformer
(2) MS structures of the transformer center (Approximately 25 meter GI strip per transformer
- as per requirement and instruction of Engineer in- charge) (All Materials will be supplied
Supply and Installation of uPVC standard make Pipe of 1.25" diameter for covering GI strip with
UV protected Cable Ties of 550 X 7.6 mm size to bind with pole face(Approximately 25 meter
uPVC pipe for GI strip covering per transformer centre -as per requirement and instruction of
Engineer in-charge.
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to
71 9926000093 Transformer H.T. including Busbar (12 mm sleev) as per technical specification. (All Materials Per Tc
will be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to
72 9926000094 Transformer H.T. including Busbar(15 mm sleev) as per technical specification. (All Materials Per Tc
will be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to
73 992600100 Transformer H.T. without Busbar (12 mm sleev) as per technical specification. (All Materials will Per Tc
be supplied by Agency)
Supply & fixing of upto 33 kV Conducotr sleev for Busbar to Drop out Fuse and Drop out fuse to
74 992600101 Transformer H.T. without Busbar (15 mm sleev) as per technical specification. (All Materials will Per Tc
be supplied by Agency)
Supply & fixing of Disc type Red Color FRP(Non-flammable) material with Weather resistant,
Non-conductive bird guard OD=300 MM, ID=33 MM, Width =1.25 MM, one side cut from ID to
OD. (All Materials will be supplied by Agency)
Providing and fixing of LT Terminal protectors i.e. Re-useable boot (LT Side 1.1 kV) including LT
(1.1 kV) insulating taps. All live part at LT side shall be covered with fixing of LT insulating taps.
77 Nylon Net around Transformer Center
77.1 9926000097 Nylon Net (12 * 15 ft) Per Net
77.2 9926000098 Nylon Dori Per TC
Labour charge for fitting Nylon Net (All fabricated material for fitting nylon net shall be provided
Name of Work : Work of ARC for Erection of HT/LT Line and TC work and other maintenance work and O/H XLPE Cable and ARC for Erection and labour work of supply,
laying, testing & commissioning of 11/22 KV Underground XLPE cable (XLPE cable will be supplied by DGVCL) with cable end termination & straight through jointing kit (To be
supplied by contractor) under All scheme for All sub Division under Olpad Rural Division.
Sr.No. Item Code Details of works Unit Rate for FY 2024-25(Rs.)
(A) LINE MAINTENANCE
1 9924000001 Cutting of Tree branches surounding HT/LT line Per Tree
Replacement of old jumpers & providing new double jumpers with 8" binding [D Type] & capsuling with
3 9924000005 Support pole for Stay PSC/STP/RSJ No.
4 9924000006 Pin binding of conductor 11/22kv Pin insulator No.
5 9924000007 Pin binding of conductor 11/22kv Pin insulator per pole in costle area with cleaning . No.
6 9924000008 Pin binding of conductor LT shakel insulator No.
7 9924000009 Replacement of one/both disc.insulator at strain pole No.
8 9924000010 Replacement of LT shackle insulator at cut point No.
9 9924000011 Refixing of V cross Arm No.
10 9924000012 Replacement of V cross Arm (With Transportation & Painting) No.
11 9924000013 Refixing of Top fitting in proper position No.
12 9924000014 Replacement of Top fitting No.
13 9924000015 Replacement of LT cross Arm No.
14 9924000016 Providing DO fuse on DP with carting & jumpuring(ONE DO FUSE) No.
Numburing of pole with paint by preparing back ground of one colour and have lettering(height 3" *
width 0.5") using stensil
16 9924000018 Fixing of MMB(1PH.) at consumer end No.
17 9924000019 Fixing of MMB(3PH.) at consumer end No.
18 9924000020 Replacement of (1ph.) meter for Urban area No.
19 9924000021 Replacement of (1ph.) meter for Rural area No.
20 9924000022 painting consumer no. on MMB (Urban) (with letter size height 40mm* width 8mm) No.
21 9924000023 painting consumer no. on MMB (Rural) (with letter size height 40mm* width 8mm) No.
22 9924000024 Replacement of deteriorated Single phase Service line No.
23 9924000025 Fixing of new dist. Box with complete wiring including clamps,nut bolts etc. No.
24 9924000026 Reparing of guarding involving reshaping of bearer wire cross lacing binding etc. R Mtr.
25 9924000027 Painting of steel fabricated material of RSJ DO DP structure with paint No.
26 9924000028 Painting of steel fabricated material of RSJ pole mounted transformer double pole structure with paint No.
27 9924000029 Painting of steel fabricated material of RSJ single pole with paint No.
28 9924000030 painting of steel fabricated material of PSC Single pole (HT line) with paint No.
29 9924000031 painting of steel fabricated material of PSC DO DP double pole with paint No.
30 9924000032 painting of steel fabricated material of PSC double pole at pole mounted transformer with paint No.
31 9924000033 Providing line seperater single phase No.
32 9924000034 Providing line seperater three phase No.
33 9924000035 Replacement / Providing of stay insulator along with adjustment of tension in stay wire No.
Replacement of deteriorated /providing LT dist. Box with new up to 100KVA capacity & crediting it to
Replacement of deteriorated /providing LT dist. Box with new above 100KVA capacity & crediting it to
36 9924000038 Adjustment of tension in stay wire No.
37 9924000039 Refitting of LA No.
38 9924000040 Converting pin point to Shackle point including dismentaling & restringing etc. location
39 9924000041 replacement of 11KV Pin insulator with providing new double pin binding No.
replacement of 22KV Pin insulator by new 11kv pin insulator with spares & providing new double pin
41 9924000043 Providing 11kv double disc insulators with binding & restringing No.
42 9924000045 Replacement of existing 11kv conductor (all size) with new double pin binding Cond/KM
43 9924000046 Plumbing of PSC Pole with straightening at pin point No.
44 9924000047 Plumbing of PSC Pole with straightening at tension point No.
45 9924000048 Plumbing of tilted DP structure (PSC/RSJ/STP) with refilling of stone Murrum etc. No.
46 9924000049 Providing new 11kv AB /GO switch with fabrication and insulated colour code jumper, binding, lugs etc Set
47 9924000051 Replacement of old 11kv AB /GO switch with providing new insulated jumper, binding, lugs etc Set
48 9924000052 Providing cage type loop guard in verticle LT line with using PVC reel insulators etc per pole
Labour charges for replacement /providing of MMB & service with all accessories for three phase
Labour charges for replacement /providing of MMB & service with all accessories for single phase
Dismentalling of existing Dist.X'mer center(RSJ /STP POLE) 25/63/100/200 KVA with all fabrication &
creditig the old material to store
Disconnection from LT pole 1 phase
Reconnection from LT pole 1 phase
( payment after receipt of R/C charges)
Disconnection from LT pole 3 phase
Reconnection from LT pole 3 phase
( payment after receipt of R/C charges)
56 9924000060 Dismentaling & removing of service line from pole & crediting to S/dn (1 ph.) No.
57 9924000061 Dismentaling & removing of service line from pole & crediting to S/dn (3 ph.) No.
58 9924000062 Reconnection of service line complete with PVC cable (1 Ph) No.
59 9924000063 Reconnection of service line complete with PVC cable (3 Ph) No.
Providing spiral type earthing by G.I. NO 8(weight 2kg -5mtr in length) with salt and coal 10kg each,
60 9924000064 including pvc rigid pipe 20mm dia( 1.5mtr length) to pass exposed part of G.I. wire at consumer end No.
with all materials, earth resistance should be less than 2 ohms
Providing and fixing of signle core 1.5 sq mm single strand copper insulated cable with cable nail clip for
spiral type earthing at consumer end. The end of G.I. no 8 is to be connected by connector with copper
61 9924000070 cable of which other end shall be connected to the earth terminal of meter box. This item shall be used per meter
in location where there is more distance between earth terminal and earthing terminal of meter. (All
materials supplied by contractor)
Stringing of LT ABC of 1*35 SQ MM + 1*25 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of messenger wire and
inclusive of dismantling charge of existing bare conductor and crediting in to store & dismentaling of
service line from LT bare conductor and to provide service connection on Aerial Bunch Cable by
insulated pierceing connectors through service connection box complete as required & directed by
Engineer in Charge.
Stringing of LT ABC of 3*50 SQ MM +1*25 SQ MM+1*35 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of existing bare conductor and crediting in to store
& dismentaling of service line from LT bare conductor and to provide service connection on Aerial Bunch
Cable by insulated pierceing connectors through service connection box complete as required &
directed by Engineer in Charge.
Stringing of 11KV ABC of 3*95 SQ MM +80 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers
etc. and inclusive of dismantling charge of existing bare conductor and crediting in to store complete as
required & directed by Engineer in Charge
Stringing of 22 KV ABC OF 3*70 SQ MM +95 SQ MM including fitting of all acessaries i.e. special design
suspension / tension clamp, fixing of cross arm, binding to pin insulator,preparing shackle point,jumpers
etc. and inclusive of dismantling charge of existing bare conductor and crediting in to store complete as
required & directed by Engineer in Charge
Stringing of LT ABC of 2*50 SQ MM +1*25 SQ MM+ 35 SQ MM including fitting of all acessaries i.e.
special design suspension / tension clamp, fixing of cross arm, LT shackle insulator etc. for fixing of
messenger wire and inclusive of dismantling charge of existing bare conductor and crediting in to store
& dismentaling of service line from LT bare conductor and to provide service connection on Aerial Bunch
Cable by insulated pierceing connectors through service connection box complete as required &
directed by Engineer in Charge.
Total Part-A 20 %
In Words Twenty Lakh Only
Schedule-B (Part -B) UG CABLE
Name of Work : Work of ARC for Erection of HT/LT Line and TC work and other maintenance work and O/H XLPE Cable and ARC for Erection and
labour work of supply, laying, testing & commissioning of 11/22 KV Underground XLPE cable (XLPE cable will be supplied by DGVCL) with cable end
termination & straight through jointing kit (To be supplied by contractor) under All scheme for All sub Division under Olpad Rural Division.
Sr. No. Item Code Description Unit FY 2024-25
Labour charge for excavation of cable trench of 400mm width x 1200mm depth, in any type of
1 9925000001 soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm additional width shall Meter
be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 600mm width x 1200mm depth, in any type of
2 9925000002 soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm additional width shall Meter
be considered i.e. half trench length is to be considered)
Labour charge for excavation of cable trench of 400mm width x 1500mm depth, in any type of
3 9925000003 soil for laying of cable of size up to 240 mm2 (For additional cable 200 mm additional width shall Meter
be considered i.e. half trench length is to be considered)
Labour charge for laying of 11kV / 22 kV XLPE Cable of size up to 240 mm2 & preparation of
sand layer 100mm thick, in the cable trench & covering the cable with 150 mm dia (Inner),
thickness 25 mm, 1.0 meter long RCC half round muffs and providing and fixing of 4inch width
4 9925000004 yellow colour polyethylene tape with printing "CAUTION ELECTRIC CABLE BELOW" at 0.75 m Meter
depth from ground surface after laying cable in trench. This will provide indication that electric
cable is passing underground so as to protect cable from mechnical injuries, refilling the same,
as per Instruction of Engineer in Charge (EIC).
Labour charge for horizontal drilling using Auger machine without damage to surface road at
max 2.0 mtrs depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm
thickness H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS certification and laying
of 11KV/22KV XLPE cable of size up to 240 mm2 in HDPE pipe, as per Site Condition
(excluding cost of pipe). The detail map obtained from HDD machine and excell sheet(hard and
soft copy) indicating the respective depth and distance from adjacent landmark for each
segment for HDD is must required to be submitted. HDD to be carried out at depth 1.5 mtrs to
2.0 mtrs as per site conditions and as per instruction of EIC.
Labour charge for horizontal drilling manually without damage to surface road at max
mtrs depth & putting of 6.11 kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984-1987(3rd revision) and BIS certification and laying of
11KV/22KV XLPE cable of size up to 240 mm2 size, as per Site Condition (excluding cost of
pipe). The detail map and excell sheet(hard and soft copy) indicating the respective depth and
distance from adjacent landmark for each segment of cable to be submitted. Drilling to be
carried out at depth Minimum 1.2 mtrs to 2.0 mtrs as per site conditions as per instruction of
Supply of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5 mm thickness H.D.P.E. pipe
7 9925000007 confirms to IS 4984 and BIS certification for laying of underground 11KV / 22KV XLPE cable up Meter
to 240 mm2 size.
Labour work for RCC concreting on disputed location and repairing of damage portion of road
8 9925000008 crossing for the work carried out for roads crossing as well as concreting & muffing of ploes CMT
including all materials (1:2:4)
Providing & fixing concrete stone route marker of 300 mm width x 150 mm thick x 650 mm
height embedded in earth at least 300 mm below & 350 mm above ground level respectively at
distance approx 50 meters along the length of cable. The RCC concreting (1:2:4)(all necessary
maeterials will be in bidder's scope) of route marker is to be carried out 300 mm width x 150 mm
9 9925000009 thick x 300 mm below ground level as per instruction of EIC. The route marker should be with No.
name of company with approved yellow colour-DGVCL. The distance from marker to cable and
cable depth with feeder name etc., marked with arrow sign is to be painted on it.The route
marker is to be fixed at location near to any fixed permanent location (not necessary to fix exact
on top of cable) as per instruction of EIC.
Erection of D.P. (double pole) structure using 9 / 11 Mtr. RSJ pole with cable connection
10 9925000010 arrangement along with fitting of necessary fabrication for 11KV cable including excavation of pit No.
& refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 9 / 11 Mtr RSJ pole with cable connection
11 9925000011 arrangement along with fitting ofnecessary fabrication for 11KV/22 KV cable including excavation No.
of pit & refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of D.P. (double pole) structure using 8.0 Mtr. PSC pole with cable connection
12 9925000012 arrangement along with fitting of necessary fabrication for 11KV cable including excavation of pit No.
& refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Erection of Single pole structure using 8.0 Mtr PSC pole with cable connection arrangement
13 9925000013 along with fitting ofnecessary fabrication for 11KV/22 KV cable including excavation of pit & No.
refilling of earth as per instruction of EIC. (Exclusive of concreting & muffing of poles)
Labour charge for erecting of 11kV / 22 kV XLPE cable of size up to 240 mm2 on DP
14 9925000014 Structure with fixing of 02 Nos polymer cleats on top and middle part.Polymer cleats, nut Per Job
bolts etc. fixing material to be provided by contractor.
Providing & fixing of 6.11kg/cm2 , class-4,Green color, 110mm O.D. , 8.5mm thickness
H.D.P.E. pipe confirms to IS 4984 and BIS certification on the erected DP structure for the
mechanical protection of cable by inserting the cable inside HDPE pipe. The HDPE pipe shall be
erected in such a way that 300mm shall be below the ground level and the rest 2700 mm shall
be supported on the DP Structure with 01 No Polymer cleat.All materials including polymer
cleat and Nut bolt to be provided by contractor.
Providing and fixing of pipe type earthing from 80 mm dia class-B GI pipe with pit to be filled
with salt & coke and construction of chamber as per DGVCL Drg. No. dg /100 for DP and cable.
The earthing pit should be joined with cable by G.I. strip of size 1” width & 2 mm thick. All
material GI pipe, Coke, Salt etc will be supplied by bidder.
Supply & fixing of heat shrink type end terminations (outdoor) for upto 11kV 3C x
mm2 size XLPE cable as per DGVCL technical specification
18 9925000018 Supply & fixing of heat & shrinkable end terminations (outdoor) for upto 22 kV 3C x 185 mm2 No.
size XLPE cable as per DGVCL technical specification)
19 9925000019 Supply & fixing of heat shrink type end terminations (indoor) for upto 11kV 3C x 185 mm2 No.
size XLPE cable as per DGVCL technical specification)
20 9925000020 Supply & fixing of heat & shrinkable end terminations (indoor) for upto 22 kV 3C x 185 mm2 No.
size XLPE cable as per DGVCL technical specification
21 9925000021 Supply & fixing of heat shrinkable straight through joint for upto 11kV 3C x 185 mm2 size No.
XLPE cableas per DGVCL technical specification.
22 9925000022 Supply & fixing of heat shrinkable straight through joint type for upto 22kV 3C x 185 mm2 No.
size XLPE cable as per DGVCL technical specification
Labour charge for excavation of 2100mm long x 1200mm wide x 1200 mm deep joint pits for
installation of 11kV / 22kV Straight through joints as per instruction of engineer-in-charge &
covering the cable with 150 mm dia (Outer), thickness 25 mm, 1.0 meter long RCC half round
muffs & refilling same as per instruction of EIC .
Providing and fixing of insulating bus bar, made from 11KV/22KV XLPE cable after removal of
semi conducting layer and applying of PVC heat shrinkable anti-tracking core insulating tubing
(1.1KV), on both end terminal using Aluminium long barrel heavy duty up to 240 sq mm lugs,
24 9925000024 Aluminium bus connector. Taping with PG- clamp for bus conductor as per drawing and as per No.
instruction of EIC. The Alluminium lugs and PG clamp shall be covered with 11KV/22KV HT
insulating tapes.(11KV/22KV XLPE cable will be in scope of DGVCL while all other materials will
be in bidder's scope)
Testing of cable at various points and commissioning the feeder as per instruction of engineer-
in-charge.Test result shall be submitted by contractor with bill.
Preparation and submission of 6 (six) copies, of complete layout drawings with GIS mapping
26 9925000026 as per actual cable routing showing road crossing, HDPE pipe sleeving, jointing locations, Set
Providing and fixing of Sign Board at junction point Made out of 2 mm aluminium sheet size
750x300 mm (2.5 x 1ft) rectangle, as per design, pre treated with phosphate process and acid
etching coated with one coat of epoxy primer and two coats of best quality paints, refloctrorised
with Hi-Intensity retro – reflective sheeting as per the latest and frame fabricated from suitable
27 9925000027 size iron angle. The Sign Board is to be fixed on the base prepared from channel and bracing No.
angles which is grouted by means of cement concreting of 1:2:4 for size of 300 mm dia x
mm height (500 mm to be grouted in ground). The details to be displayed on sign board will be
given by In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing and fixing of Sign Board (Danger Board) on Distribution Transformer Centers
Made out of 2mm aluminium sheet size 300x300mm (1x1ft) as per design, pre treated with
phosphate process and acid etching coated with one coat of epoxy primer and two coats of best
28 9925000028 quality paints, refloctrorised with Hi-Intensity retro-reflective sheeting as per the latest and frame No.
fabricated from suitable size iron angle. The Sign Board (Danger Board is to be fixed at the
location as per instruction of In-charge Engineer.
(a) Hi intensity Micro prismatic Grade
Providing & fixing of aluminium tag of size 250 mm (L) x 75 mm (W) from 3 mm aluminium
sheet along with 1.0 mm dia aluminium binding wire for fixing of aluminium tag near end
29 9925000029 termination joint at DP structure for identifyng the cable. The details of feeder i.e. 11 / 22 KV with No.
feeder name shound be punched on the tag by letter punch of size 16 mm as per instruction of
In-charge Engineer.
Supply & fixing of heat shrink type end terminations (outdoor) for 11kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification
Supply & fixing of heat & shrinkable end terminations (outdoor) for 22 kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification)
Supply & fixing of heat shrink type end terminations (indoor) for 11kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification)
Supply & fixing of heat & shrinkable end terminations (indoor) for 22 kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification
Supply & fixing of heat shrinkable straight through joint for 11kV 3C x 240 mm2 size XLPE
cableas per DGVCL technical specification.
Supply & fixing of heat shrinkable straight through joint type for 22kV 3C x 240 mm2 size
XLPE cable as per DGVCL technical specification
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRL type- 3 Way
36 9925000038 RMU including Two numbers of earthings as per Drawing (material is in bidder's scope) and as No.
per DGVCL Technical specification.
Installation, Testing and commissioning of 11 KV,630 A SCADA Compatible, RRLL type-
37 9925000039 Way RMU including Two numbers of earthings as per Drawing (material is in bidder's scope) No.
and as per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRL type-3 Way,
38 9925000040 RMU including Two numbers of earthings as per Drawing (material is in bidder's scope) and as No.
per DGVCL Technical specification.
Installation, Testing and commissioning of 22KV,630 A SCADA Compatible, RRLL type-4 Way,
39 9925000041 RMU including Two numbers of earthings as per Drawing (material is in bidder's scope) and as No.
per DGVCL Technical specification.
Construction of plinth for 11KV, RRL type- 3 Way (i.e Two numbers of Isolator & One
40 9925000042 number of Breaker) Ring Main Unit as per DGVCL's technical specification mentioned in No.
drawing no: Drg. 11kv-01. All required material will be supplied by contractor.
Construction of plinth for 11KV, RRLL type- 4 Way (i.e Two numbers of Isolator & Two
41 9925000043 number of Breaker)Ring Main Unit as per DGVCL's technical specification mentioned in drawing No.
no:Drg. 11kv-02.All required material will be supplied by contractor.
Construction of plinth for 22KV, RRL type- 3 Way (i.e Two numbers of Isolator & One
42 9925000044 number of Breaker) Ring Main Unit as per DGVCL's technical specification mentioned in No.
drawing no: Drg. 22kv-01. All required material will be supplied by contractor.
Construction of plinth for 22KV, RRLL type- 4 Way (i.e Two numbers of Isolator & Two
43 9925000045 number of Breaker)Ring Main Unit as per DGVCL's technical specification mentioned in drawing No.
no:Drg. 22kv-02.All required material will be supplied by contractor.
Modifications e.g.Providing and fixing of Terminal protectors i.e. Re-use able boot (HT Side
11/22KV, LT Side 1.1KV) including 11/22 KV insulating taps and L.T.(1.1 KV) insulating taps
,Busbar, Tapping from Bus Bar (11/22 KV XLPE cable) through P.G. Clamp for H.T. Jumper to
D.O. Fuse to bushings of Transformer Center, providing & Fixing of jumper and providing &
fixing of Heat Shrinkable Anti Tracking Core Insulating Tubing (Insulation Level 11/22 KV) in H.T.
jumper , Clamping arrangement of cable support frame on both side of existing Over Head type
44 9925000046 Distribution Transformer to utilize in Under Ground cable network as per drawing & as per No.
instruction of Engineer incharge. All live parts i.e. PG-Clamp, connections of D.O.fuses, HT
bushings etc . shall be covered with fixinng of 11/22 KV HT insulating tapes. ( 11/22 KV XLPE
cable will be in scope of DGVCL while all other materials will be in bidder's scope ) .
45 9925000047 Laying of any size of 11/ 22 KV XLPE /PILC Cable in redaymade trench or in open space
46 9925000060 Labour charges for Lying of O/H XLPE cable pole to pole KM
47 9925000064 Supply of 150 mm dia (Inner), thickness 25 mm, 1.0 meter long RCC half round pipe No.
Total (Part-B 80%)
In Words :- Eighty Lakh Rupees Only
Grand Total Part -A & Part - B
Grand Total Part -A & Part - B
In Words :- One Crore Only
% Above Below of Estimate Amount
Stamp & Sign of Contractor
Executive Engineer (O&M)
DGVCL, Olpad Rural Division
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.ALL SDN Draft FOR 1 cR.pdf
2. All SDN Bid Document.pdf
3. ALL SDN Detail Tech Specification.pdf
4. All Erection and Maintenance for Technical Specification.pdf
5.Olpad 1 Cr Schedule -b-with erection and UG Cable.pdf
6.Reference Bid Drawing.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .