| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.2 LAccepted-AOC GANDHI CHOWK SHIV MANDIR MARG RANIKHET DISTT ALMORA UTTARAKHAND | L1 | Accepted-AOC Being lowest tenderer | |
| 2 | L2₹37.4 L+₹3.7 L (10.8%)Rejected-Finance BHATT COLONY KAMALUWAGANJA ROAD HARIPUR NAYAK KUSUMKHERA HALDWANI DISTT NAINITAL UK | L2 | Rejected-Finance Not being lowest tenderer | |
| 3 | L3₹38.0 L+₹4.3 L (12.6%)Rejected-Finance | L3 | Rejected-Finance Not being lowest tenderer |
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
24 Sept 2022, 6:00 pmClosed
GE RANIKHET
GE MES RANIKHET
Repair maint of solar water heating system DG sets and repair maint of refrigeration and air conditioning applaiances at Ranikhet and Chaubattia under GE Ranikhet
2022_MES_546863_1
GE/RKT/45 OF 2022-23
Open Tender
Civil Works
Works
180 days
Ranikhet and Chaubattia under GE Ranikhet
As per NIT
6 documents required · 6 mandatory
₹500
GE RANIKHET
₹77,000
26 Oct 2022
22 Aug 2022
1 Oct 2022
22 Aug 2022
24 Sept 2022
5 Sept 2022
Amount
BOQ ( Sch A ) Solar Heating System Taking up or down 15 mm bore unserviceable water tubing and connection including cleaning for refixing and removal from site complete all as specified and dircted
All as per item No 1 here in before but bore of pipe 20 mm
All as per item No 1 here in before but bore of pipe 25 mm
Supply and fixing Steel water tubing medium grade galvanised with all GI fittings (such as bend, elbows,tees, connections, short pieces, back nuts, unions, caps & plugs etc) laid in trenches, on wall or in floor bore of pipe 15mm complete all as specified and directed.
All as per item No 4 here in before but bore of pipe 20 mm
All as per item No 4 here in before but bore of pipe 25mm
Refixing only 15 mm bore steel water tubing with and including all GI fittings and accessories etc laid in trenches or open surfaces complete all as specified and directed. Note:- Seviceable GI tubing retreived from item No 1 will be reused )
All as per item No 7 here in before but 20mm dia bore complete all as specified and directed. ( Note:- Seviceable GI tubing retreived from item No 2 will be reused )
All as per item No 7 here in before but 25mm dia bore complete all as specified and directed. ( Note:- Seviceable GI tubing retreived from item No 3 will be reused )
Supply, fixing , testing & commissioning of solar collector ( 1 Mtr X 2 Mtr ) complete all as specified and directed.
Supply, fixing , testing & commissioning of solar collector ( 1.2 Mtr X 1.8 Mtr ) complete all as specified and directed.
Supply, fixing , testing & commissioning of toughened U.V Glass ( 1 Mtr X 2 Mtr ) and as per existing size of glass for collector complete all as specified and directed.
Supply, fixing , testing & commissioning of toughened U.V Glass ( 1.2 Mtr X 1.8 Mtr ) and as per existing size of glass for collector complete all as specified and directed.
Material & Labour for Descaling of collector using very mild mineral acid to clear the deposites of temporary hardness in side of collector tubes including brazing of leaking joint as required at site complete all as specified and directed. Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Supply and fixing rubber washer complete all as specified and directed.
Supply, fixing , testing & commissioning of insulation materials for hot / cold water pipe any size and size of insulation on pipe 5 cm thick glass wool / mineral wool with chicken mesh and Aluminium cladding 26 swg complete all as specified and directed.
Material and labour for descaling of heat exchanger in side of hot water tank and hot water tank after repair , testing of hot water tanks capcity 1500 /1000 ltrs including replacement cold water pipe/ hot water pipe complete all as specified and directed. Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Material and labour for descaling of heat exchanger in side of hot water tank and hot water tank after repair , testing of hot water tanks capcity 200/500 ltrs including replacement of old cold water pipe/ hot water pipe complete all as specified and directed. Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Material and labour for Gas welding of leaking joint in the flat panel collector complete all as specified and directed.
Supply and fixing heating element 2 KW complete all as all as specified and directed.
Supply and fixing thermostate for heating element 2 KW complete all as all as specified and directed.
Material & labour for sub main wiring with 1100 volt grade two single core PVC insulated and unsheathed cable with multi stranded copper conductor 6 sqmm (FRLS) drawn into and including electrical grade PVC conduit not less than 25 mm dia with IS 9537 (PART-III) 1983 marked or relevant ISI marked with all accessories fixed concealed including chase cutting in brick/ stone/ precost PCC block masonry for fixing conduit and making good the disturbed surfaces of wall as per existing including 4 sqmm multi - stranded copper conductor as earth wire in green colour including taking down existing unserviceable sub main wiringcomplete all as specified and directed. NOTE: - 2 runs of 6 sqmm single cable , one run of 4 sqmm earth wire cable and PVC conduit shall be considered as one unit/1Rm)
Supply & Fixing coloured rotational moulded polythene water storage tanks Triple layered (cylindrical vertical with closed top) hoisted and fixed in postion 500 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
Supply & Fixing coloured rotational moulded polythene water storage tanks Triple layered (cylindrical vertical with closed top) hoisted and fixed in postion 1000 ltrs capacity with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe minimum weight 210 gram complete all as specified and directed.
Supply and fixing in repair ball brass valve high pressure with polyethene float and fly nut complete screwed for iron pipe of size 25 mm complete all as specified and directed .
Supply and fixing in repair ball brass valve high pressure with polyethene float and fly nut complete screwed for iron pipe of size 20 mm complete all as specified and directed .
Material and labour for insulation of hot water tank of cap 1000/1500 ltrs with thick ness of insulation 10 cm around the tank and aluminium sheet of size 24 SWG complete all as specifide and directed . Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Material and labour for insulation of hot water tank of cap 200 /500 ltrs with thick ness of insulation 10 cm around the tank and aluminium sheet of size 24 SWG complete all as specifide and directed . Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Supply and fixing in replacement hot water tank of cap 1000/1500 ltrs with thick ness of insulation 10 cm around the tank and aluminium sheet of size 24 SWG as per existing sample including make up tank & connection with existing pipe line complete all as specified and directed . Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Supply and fixing in replacement hot water tank of cap 200 ltrs with thick ness of insulation 10 cmaround the tank and aluminium sheet of size 24 SWG as per existing sample including make up tank & connection with existing pipe line complete all as specifide and directed . Note:- The quoted rate shall include the cost of cutting & refixing of monkey caging as required at site . Nothing extra shall be admissible on this acconut.
Material and labour for connecting & testing of CI air release valve 25mm size ISI marked flanged type including jointing material such as fibre board , nut , bolt, washers and welding etc complete all as specified and directed.
Material and labour for connecting & testing of CI air release valve 20mm size ISI marked flanged type including jointing material such as fibre board , nut , bolt, washers and welding etc complete all as specified and directed.
Material and labour for connecting & testing of CI air release valve 15mm size ISI marked flanged type including jointing material such as fibre board , nut , bolt, washers and welding etc complete all as specified and directed.
Taking out old unserviceable gun metal, globe or gate valve and including Supply and fixing gun metal, globe or gate valves ISI marked class-I, with iron wheel head, screwed both ends, for iron pipe bore dia of pipe 25mm complete all as specified and directed.
All as per item No 34 here in before but bore dia of pipe 20 mm
All as per item No 34 here in before but bore dia of pipe 15 mm
Supply and fixing of sheet metal enclosure for DB’s (Double door type) when MCB’s to be used, single pole and neutral, 8 ways with 200 Amp rated bus bar, 240 volts including blanking plates fixed sunk / flush to the wall or niche complete all as specified and directed.
Supply & Fixing in repair 240 V, 10 KA 'B' curve miniature circiut breaker ( MCB) of single poles and current carrying capacity 6 to 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply & Fixing in repair 240 V, 10 KA 'B' curve miniature circiut breaker ( MCB) of single poles neutral ( SPN) and current carrying capacity 32 AMP, in the MCB DB complete with connection testing and commissioning complete all as specified and directed.
Supply & Fixing service connection cable, 1100 volts grade heavy duty PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular, 10sqmm multi stranded aluminium conductor complete all as specified and directed.
Supply and fixing expanded metal weight not exc 4 kg per square metre, cut to length bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel staples and fixed to wood or steel member complete all as specified and directed
Supply & Fixing framed work such as in grill, grating etc with ends of bars shouldered and/or rebated,or forged into spike frame guard bars,wake way,railing,frame work of water tank and similar work such as purlin, truss, square tube etc confirming to Fe-290-w (Gde 165) complete all as specified and directed.
Material & Labour for preparation of new or previously untreated steel and iron surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red oxide primer, complete all as specified and directed.
Material and labour for complete cleaning and descaling of heat exchanger installed at swimming pool using very mild mineral acid including complete opening and reassembling the same and testing for its proper functioning all as specified and directed by Engineer-in-charge.
Disconnecting/ Taking out of old non return valve, including supply & fixing brass non return valve of size 20 mm bore with and including nut, bolts & washers complete all as specified and as directed.
Disconnecting/ Taking out of old non return valve, including supply & fixing brass non return valve of size 15 mm bore with and including nut, bolts & washers complete all as specified and as directed.
M & L for opening of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) water cooled by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge, repair/ replacement of stopper key etc and reassembling the DG set after repair/ replacement of unserviceable parts of DG set and testing at Ranikhet & Nagpani complete all as specified and directed.
Supply & Fixing fuel filter of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
Supply & Fixing lube oil filter of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
Supply & Fixing air filter of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
Supply & Fixing copper washer of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
Supply & Fixing banjo bolt of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
S & F fuel pipe of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
S & F hose water pipe for radiator of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
S & F warm drive H / clip of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
S & F V – belt of DG set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) complete all as specified and directed.
S & F asbestos rope of size 20mm dia on exhaust pipe of DG set 180 KVA (existing make CUMMINS) complete all as specified and directed.
S & F PVC superior quality coolant side box for 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR) DG set complete all as specified and directed.
M & L for opening of DG set 45/50/63/62.5 KVA water cooled of existing Make KRILOSKAR by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of unserviceable parts of DG set and testing complete all as specified and directed.
S & F fuel filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F lube oil filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F air filter of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F copper washer of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F banjo bolt of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F fuel pipe of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 45/50/6362.5 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F V – belt of DG set 45/50/63/62.5 KVA complete all as specified and directed.
S & F fuel pump for 45/50/62.5/63 KVA DG as per sample complete all as specified and directed.
M & L for opening of DG set 15 KVA water cooled of existing Make KIRLOSKAR by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of unserviceable parts of DG set and testing complete all as specified and directed.
S & F fuel filter of DG set 15 KVA complete all as specified and directed.
S & F lube oil filter of DG set 15 KVA complete all as specified and directed.
S & F air filter of DG set 15 KVA complete all as specified and directed.
S & F copper washer of DG set 15 KVA complete all as specified and directed.
S & F banjo bolt of DG set 15 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 15 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 15 KVA complete all as specified and directed.
S & F V – belt of DG set 15 KVA complete all as specified and directed.
M & L for opening of DG set 7.5/10 KVA water cooled of existing Make : KIRLOSKAR by unscrewing nuts, bolts and servicing of DG set with checking of oil, coolant, V belt, greasing and oiling of parts and topping up, cleaning the inner body, tank and radiator by removing sludge etc and reassembling the DG set after repair/ replacement of unserviceable parts of DG set and testing complete all as specified and directed.
S & F fuel filter of DG set 7.5 /10KVA complete all as specified and directed.
S & F lube oil filter of DG set 7.5/10 KVA complete all as specified and directed.
S & F air filter of DG set 7.5 /10KVA complete all as specified and directed.
S & F copper washer of DG set 7.5/10 KVA complete all as specified and directed.
S & F banjo bolt of DG set 7.5/10 KVA complete all as specified and directed.
S & F hose water pipe for radiator of DG set 7.5/10 KVA complete all as specified and directed.
S & F warm drive H / clip of DG set 7.5/10 KVA complete all as specified and directed.
S & F V – belt of DG set 7.5/10 KVA complete all as specified and directed.
Supply only coolant in 05 (Five) litre packing, Make : Servo / CRB Plus/HP complete all as specified and directed.
Supply only distilled water 05 (Five) litre packing complete all as specified and directed.
Supply & filling engine oil of recommended grade 15W40, Make: Servo / CRB Plus/HP complete all as specified and directed.
S & F lead acid battery 12 Volt 150 AH for DG set, Make: Exide Xp / Amaron / Luminous including taking out old unserviceable battery complete all as specified and directed.
S & F lead acid battery 12 Volt 180 AH for DG set, Make: Exide Xp / Amaron / Luminous including taking out old unserviceable battery complete all as specified and directed.
S & F battery terminal brass complete with GI nuts & bolts including taking out old unserviceable battery terminal brass complete all as specified and directed.
S & F battery lead wire as per existing size and length, flexible copper conductor single core including taking out old unserviceable battery lead wire complete all as specified and directed.
Repair to self starter assembly of DG set of cap 45/50/63/62.5 KVA by cutting of old burnt winding wire and winding with new copper winding wire as per existing size / gauge including insulation materials, varnishing, heating / drying up etc complete all as specified and directed.
Repair to self starter assembly of DG set of cap 15/10/7.5 KVA by cutting of old burnt winding wire and winding with new copper winding wire as per existing size / gauge including insulation materials, varnishing, heating / drying up etc complete all as specified and directed.
Supply and fix self starter assembly complete of DG set of cap 45/50/62.5/63 KVA by taking out of old burnt self starter as per existing size / gauge etc complete all as specified and directed.
Supply and fixing rotary hand pump for filling of fuel from barrel to DG set tank with PVC pipe of size 20 mm dia sureior quality of lenght ten mtr complete all as specified and directed.
M&L for repair of DG Set 180 KVA (existing make CUMMINS) / 125 KVA (existing make KIRLOSKAR), Opening of cylender head, FIP, self start assembly, cleaning all the parts of engine and chamber by Kerosin oil, removing connecting rod,crank shaft, removing all the piston rings from piston and replacing of piston ring, connecting rod bush of all piston of existing size and shape replacing all engine valve, replacing cylinder head, over hauling of caliber of FIP as per required including the nozzel, replacing all the gasket including cylinder head gasket as required, of generator set 180/125 KVA cleaning , checking and adjusting of aneroid oil, throttle linkage, fuel tank breather, crankcase breather, air piping, oil bath air cleaner tray screen and belt including replacing of engine oil, full flow oil filter , by pass filter air compressor breather element, fuel filter primary and secondary, cleaning of radiators, repair/ replacement of unserviceable injector 6 Nos, change of valve and kit in head of DG Set etc all as specified and directed by the Engr-in-charge.
M&L for repair of DG Set 62.5/63 KVA of existing Make KIRLOSKAR, Opening of cylender head, FIP, self start assy, cleaning all the parts of engine and chamber by Kerosin oil, removing connecting rod,crank shaft, removing all the piston rings from piston and replacing of piston ring, connecting rod bush of all piston of existing size and shape replacing all engine valve, replacing cylinder head, over hauling of caliber of FIP as per required including the nozzel, replacing all the gasket including cylinder head gasket as required, of generator set 63 KVA cleaning , checking and adjusting of aneroid oil, throttle linkage, fuel tank breather, crankcase breather, air piping, oil bath air cleaner tray screen and belt including replacing of engine oil, full flow oil filter , by pass filter air compressor breather element, fuel filter primary and secondary etc all as specified and directed by the Engr-in-charge.
S & F in repairs of control pannel inside DG set of 45/50/62.5/63 KVA, replacement of unserviceable MCBs, indicators, start stop buttons, sensors, wiring with suitable size cable and checking entire circuit complete all as specified and directed.
M&L for earthing complete with galvanised steel, earth plate electrode 600x600mm x 6mm thick burried directly in ground verticaly (earth pit not less than 2.25 mtrs below ground level ) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanised strip 32x6mm as earth lead by means of bolts, nuts, check nuts and washers of galvanised iron/steel all as shown in electrical plate No 3 on page 497 of MES schedule 2009 part - I connected to main switch board/main DBs/earthing test point including all necessary excavation and earth work in hard/dense soil, common salt and charcoal dust mixed and packed 150mm thick all round the GI earth plate, watering pipe 20mm dia GI medium grade. GI sheet 0.63 mm thick funnel, wire gauge, 50mm thick RCC cover in PCC 1:2:4 type B1 duly reinforced with MS round bars 6mm dia @ 150c/c both ways and pit/chamber in PCC 1:3:6 type C1 with suitable lifting handle to cover, GI protection pipe 15mm dia light grade up to 7.5mtr from electrode GI pipe to be fixed with complete all as specified and directed. Note :- (i) Earth lead beyond 7.5 mtr from electrode to earth terminal point/main switch & GI pipe light grade 15mm dia for protection against mechanical damage to lead shall be measured separately. (ii) On testing after completion if desired earth resistance is not obtained, the earthing will be redone by the contractor at his own expensis and no extra payment on this account shall be made by the Govt.
Supply and fix aluminium lugs of size 300 sqmm complete all as specifide and directed .
Supply and fix aluminium lugs of size 240 sqmm complete all as specifide and directed .
Supply and fix aluminium lugs of size 185 sqmm complete all as specifide and directed .
Supply and fix aluminium lugs of size 150 sqmm complete all as specifide and directed .
Supply and fix changeover switch AC 23 side handle 4 pole , 415 Volt 40 Amp complete all as specifide and directed .
Supply and fix changeover switch AC 23 side handle 4 pole , 415 Volt 63 Amp complete all as specifide and directed .
Supply and fix changeover switch AC 23 side handle 4 pole , 415 Volt 100 Amp complete all as specifide and directed .
Supply and fix changeover switch AC 21 side handle 4 pole , 415 Volt 200 Amp complete all as specifide and directed .
Supply and fix changeover switch AC 21 side handle 4 pole , 415 Volt 320 Amp complete all as specifide and directed .
Supply and fix in replacement on load changeover switch 4 pole , 415 Volt 630 Amp in open execution as per existing make complete all as specifide and directed .
Replacement of MCCB of Cap 100 Amp, 4 Pole, 25 KA, with adjustable thermal release and earth fault protection, 415 volt grade including cutting and welding work for fixing of MCCB in existing panels any type and model complete all as specifide and directed .
All as per item No. 113 above but Cap 200 Amp, 36 KA.
All as per item No. 113 above but Cap 315 Amp, 36 KA.
Supply, laying, jointing and commissioning 120 Sqmm, 3.5 core LT XLPE 1100 volts grade heavy duty cable PVC insulated, multi stranded aluminium conductor served with inner sheathing of PVC tape, armoured with GI steel or tape and over all PVC sheathing laid in trenches, floor through pipes or induct or on pole and roads etc complete all as specifide and directed .
All as per item No. 116 above but of size 95 Sqmm, 3.5 core.
All as per item No. 116 above but of size 70 Sqmm, 3.5 core.
Excavation in trenches in hard/dense soil not exc 1.5 mtrs wide and not exc 1.5 m in depth for laying cables and getting out incl jointing bottom surface to the reqd level/slope etc complete all as specified and directed.
Returning fillingin, incl spreading, leveling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material (soil) to a distance not exc 50 mtr and deposting where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
Material and labour for sand cushioning with a layer of fine sand 8 cm thick before laying the cable and 15 cm after laying the cable in trenches to cover under ground cable complete all as specified and directed. Note : Punned down thickness of sand shall be considered for measurement and payment.
Material and labour for brick protection to cable using old size class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable complete all as specified and directed.
M&L for 80 mm bore GI pipe light grade with all GI fittings fixed to pole and laid to floor/ground for mechanical protection of cable complete all as specified and directed.
M&L for 50 mm bore GI pipe light grade with all GI fittings fixed to pole and laid to floor/ground for mechanical protection of cable complete all as specified and directed.
Supply and fixing ignition transformer for the oil fired chamber as per sample, incoming voltage 230 volts and outgoing voltage 14500 voltss installed at MH Ranikhet complete all as specified and directed.
.Supply and fixing Solenoid valve as per existing Cat part No. 8510113200 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Burner nozzle 2.5 GPH 80 degree PY - 75/100 as per existing Cat part No. 8904111400 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Diffuser plate assembly for MI as per existing Cat part No. 1061602630 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Photo cell type - 8205 as per existing Cat part No. 8603111400 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Pressure gauge Cat 0 - 40 Kg/cm 1/2 BSP as per existing Cat part No. 8451114100 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing Metalic hose 40 Kg / cm as per existing Cat part No. 8911104000 for oil fired incinerator of Make Thermex, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing electrode` for oil fired incinerator, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing glass wool for oil fired incinerator, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Supply and fixing filter assembly for oil fired incinerator, capacity 50 Kg / hours installed at MH Ranikhet complete all as specified and directed.
Repair/Replacement of iron plate of upper tank body of incineraor including necessary cutting and welding work and matching the disturbed surface with the existing surface complete all as specified and directed.
Supply and fixing in repair the chimney top mounted indication/signal lamp with red light for emergency signal as per existing size and complete testing after installation complete all as specified and directed.
S & F in repair water tubing medium grade galvanised with all GI fittings (such as bend,elbows,tees, connections, short pieces, back, nuts, unions, caps & plugs, reducer etc) of size 20 mm bore laid in trenches or fixed on walls or on open surfaces complete all as specified and directed.
Overhauling & servicing of Refrigerator any capacity and make by carrying out the following works at different location of different establishment complete all as specified and directed by Engineer-in-charge (a) Inspection, taking down opening & dismantling descaling brushing cleaning of refrigerator (b) Check and correct earth continuity of electrical items (c) Check thermostate and test its functioning (d) Check & correct all electrical wiring and its functioning (e) Testing of Refrigerator after repairs (f) Replacing defective spare parts
Petty repair complaints for Refrigerator of any capacity and make installing in site of Ranikhet & chaubattia and rectifying the complaints from 0900 hrs to 1700 hrs incl Sunday & Holidays complete all as specified and as directed by Engineer-in-charge. NOTE : Any defective part which are required to be replaced to make functional refrigrator shall be measured and paid separately under respective items as supply only.
Supply only in replacement to unserviceable Vegetale tray as per existing make & capacity
Supply only in replacement to unserviceable Thermostate switch as per existing make & capacity
Supply only in replacement to unserviceable Starting relay as per existing make & capacity
Supply only in replacement to unserviceable electronic timer unit as per existing make & capacity
Supply only in replacement to fused Bulb as per existing
Supply only in replacement to unserviceable capillary & filter as per existing
Supply only in replacement to unserviceable Freezer tray as per existing
S&F the refrigerant gas to Refrigerator up to required level after detecting & repairing leakage improvement of efficiency testing complete all as specified and directed by Engineer-in-charge
S&F in replacment of condensor coil of refrigerator as per existing incl brazing of all associated pipe lines complete all as specified and directed by Engineer-in-charge
S&F in replacement new compressor for refrigerator of capacity 165 to 320 ltrs as per existing make & model including brazing work pressure testing dehydration complete all as specified and directed by Engineer-in-charge
S&F in replacement of unserviceable fan unit of refrigerator and providing electrical connection as per existing make & model complete all as specified and directed by Engineer-in-charge
Overhauling and servicing of split type AC of capacity 1.5/2.0 TR of any make at different locations of different establishment, testing the unit complete with the following :- (a) Overhauling & servicing (b) Inspection opening washing the condensor coil and cooling coil with chemical followed with water complete (c) Inspection of leakage of refrigerant in the system (d) Checking the operation of blower motor condensor motor for noise free operations (e) Oiling of condensor / blower motors and checking the earth continuity (f) Inspection all electrical parts / connections and removing if any defect (g) Checking the functional of electronic remote control complete all as specified and as directed by Engineer-in-charge.
Petty repairs complaints for split type AC of capacity 1.5 / 2.0 TR, rectifying the defects and making machine satisfactory functional. NOTE : Any defective part which are required to be replaced to make functional split type ACs shall be measured and paid separately under respective items as supply only.
Supply only in replacement of unserviceable starting relay of Split type in lieu of providing new starting relay all as per existing.
Supply only in replacement of unserviceable starting capacitor 120-150 mfd
Supply only in replacement of unserviceable starting capacitor 100-120 mfd
Supply only in replacement of unserviceable contactor as per existing
Supply only in replacement of unserviceable propeller fan for split type AC of capacity 1.5 / 2.0 TR as per existing all as specified and directed by Engineer-in-charge
Supply only in replacement of unserviceable but new condensor fan motor of any type of split type ACs of capacity 1.5 /2.0 TR
Supply only in replacement of unserviceable blower motor for split type AC 1.5 / 2.0 TR as per existing
Supply only in replacement of unserviceable blower for split type AC 1.5 / 2.0 TR as per existing
Supply only in replacement of unserviceable 3 core flexible copper cable of size 70/0.0076 complete all as specified and as directed by Engineer-in-charge
Supply only in replacement of unserviceable 3 core flexible copper cable of size 80/0.0020 complete all as specified and as directed by Engineer-in-charge
S&F in replacement new compressor for split type AC of capacity 1.5 TR as per existing including brazing work extra copper tubing pressure testing dehydration complete all as specified and directed by Engineer-in-charge
M&L for rewinding of condensor fan motor for split type AC including replacement of gun metal bushes, testing complete all as specified and as directed by Engineer-in-charge
M&L for rewinding of blower motor for split type AC including replacement of gun metal bushes, testing complete all as specified and as directed by Engineer-in-charge
M&L for Gas charging R-22/R-410/407/410 at site as per requirement of ACs any capacity including removal and replacement copper tubing of required size of liquid filter, capillary including testing on full load for summer season complete all as specified and as directed.
M/S BHATT ENTERPRISES
AJA BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .