Tender Value
Refer Docs
EMD Value
₹6,400
Closing Date
13 Oct 2026, 10:00 am3d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
EXECUTIVE ENGINEER OFFICE, ELECTRICAL DIVISION, CH
EXECUTIVE ENGINEER OFFICE, ELECTRICAL DIVISION, TRAVANCORE DEVASWOM BOARD, CHENGANNUR
Thiruvallom Devaswom rewiring Rewiring work of Thiruvallom Devaswom inside belimandapam Valyambalam Thidapalli and toilet block
2026_TDB_877604_1
TDB/EEE/ET-80/2026-27
Open Tender
Electrical Works
Percentage
5 days
Thiruvallom
Please refer Tender documents.
10 documents required · 10 mandatory
₹661
₹6,400
8 Oct 2026
8 Oct 2026
13 Oct 2026
8 Oct 2026
13 Oct 2026
8 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1re wiring Thiruvallam devaswom | |||||
| 1.001 | OD148445/2026-2027:Dismantling the existing PVC conduits ,switchboard, Distribution boards ,cables and all other
accessories as required for the proper completion of the work and fixing the switch boards,
distribution boards(single phase & three phase) in recess by cutting holes suitable sizes on wall
and making good the damages etc.(concealing the cables and PVC conduit near the switch
board and DBs) Wireman Assistant | 2 | no | 776.25 | ₹1,552.5 |
| 1.002 | OD148446/2026-2027:Dismantling and carefully stacking damaged electrical installation engaged wireman | 2 | no | 1,244.27 | ₹2,488.54 |
| 1.003 | OD148447/2026-2027:Supply and fixing following size bulb to the existing points 50W LED Large size bulb. | 4 | each | 534.88 | ₹2,139.52 |
| 1.004 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) | 30 | metre | 67.06 | ₹2,011.8 |
| 1.005 | 90.2.1.10:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Medium point | 25 | point | 1,157.85 | ₹28,946.25 |
| 1.006 | 90.2.1.15:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Long Point | 10 | point | 1,468.29 | ₹14,682.9 |
| 1.007 | 90.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories and lamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copper conductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture | 15 | each | 1,249.13 | ₹18,736.95 |
| 1.008 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature
circuit breaker suitable for inductive load of following poles in the existing MCB
DB complete with connections, testing and commissioning etc. as required.
Single pole | 45 | each | 301.21 | ₹13,554.45 |
| 1.009 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps | 7 | each | 511.7 | ₹3,581.9 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.07 MB
ApprovedMateriallist.pdf
Tender Documents • 0.50 MB
FormOfTenderdocument80.pdf
Tender Documents • 0.07 MB
SBD80.pdf
Tender Documents • 0.34 MB
SPECIALCONDITIONSforEtender.pdf
Tender Documents • 0.08 MB
BOQ_1491434.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .