Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC L1 (Lowest quottee) | |
| 2 | L2₹21.9 L+₹91,523 (4.36%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.1 L+₹1.1 L (5.08%)Rejected-AOC | L3 | Rejected-AOC L3 |
Tender Value
Refer Docs
EMD Value
₹38,600
Closing Date
26 May 2020, 10:00 amClosed
Executive Engineer
Rakesh Verma, Executive Engineer (Civil)
C/o Seed Germplasm Centre For Ayurveda Department at Neri, Hamirpur (H.P. Govt.)
2020_CSIR_48514_1
5-178(A)/Ws/19
Open Tender
Construction Works
Works
150 days
CSIR-IHBT, PALAMPUR
As per NIT and contract document
2 documents required · 2 mandatory
₹500
Director
₹38,600
1 Sept 2020
18 May 2020
27 May 2020
18 May 2020
26 May 2020
19 May 2020
18 May 2020 - 26 May 2020
Amount
Earth work in excavation by mechanical means (Hydraulic exavator)/mannual means in foundation trenches or drains not exceeding 1.5m in width or 10 sqm on plan), including dressing of sides and remming of bottoms, lift upto 1.5 m, including getting out the excauvated soil and disposal of surplus excauvated soil as directed,within a lead of 50 m, All kinds of soil.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level :1;4;8(1cement:4coarse sand:8 grades stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering- All work up to plinth level :1:2:4 (1cement:2coarse sand:4 grades stone aggregate 40 mm nominal size).
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth inCement mortar 1:6 (1 cement:6 coarse sand)
Steel work in built up tubular round,square or recetangular hollow tubes etc.) trusses etc. , including cutting, hosting, fixing, in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc. complete.:Electric resistance or induction butt welded tubes.
12 mm cement plaster of mix : 1:6 (1 cement:6 fine sand)
Providing and fixing agroshading net (50%) net over the specified area of polyhone (finished are shall be measured for payment)
Providing and fixing G.I. profile of 0.8 m thickness complete with Zig-Zag G.I.spring for tightening of UV stabilized Rigidex film
Providing and fixing G.I. chicken mesh on angle iron structure with G.I. Wire 1 mm thick.
Providing and fixing G.I. wire 2 mm thick including cutting and making holes in MS/GI structure including cutting,stretching and tightening to the structure.
Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.: All kinds of soil
Supplying at site Angle iron post & strut of required size including bottom to be split and bent at right angle in opposite direction for 10 cm length and drilling holes upto 10 mm dia. etc. complete.
Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. :With G.I. barbed wire
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work
Providing and fixing 150 gsm rigidex film with necessary screws etc.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : : For fixed portion : Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15)
80mm thick double skin panels, in walls/partitions/Ceiling, made up of 0.6mm thick (TCT) powder coated G.I. Sheet on both sides of panels., filled with CFC free puf (density 40Kg/cum), including other required accessories End channels/Tongue and groove jointing system complete in all respects.
Providing and fixing double skin door leaf (single/double), 44mm thick made out of 0.8mm thick GPSP metal sheet including 38 density PUF infilled. The finish shall be 50 microns epoxy powder coating and will have provision of fixing hardware excluding cost of hardware like door closer, handles, lock, door stopper but including cost of SS hinges 125x64x1.9mm complete in all respects.
Providing and fixing single rebate door frame of required size made out of 1.2 mm thick G.I. Sheet formed to single rigid profile of size 80mmx45mm. The door frame shall have back plates as reinforcement on all jaws for taking all hardwares, including fixing in position with anchor bolts. The door frame shall be 50 microns epoxy powder coated including fixing of high quality rubber gasket for sealing it with shutter. The rebate shall be suitable for fixing of shutter.
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.: Size of Tile 600x600 mm
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. : 40 mm thick with 20 mm nominal size stone aggregate
Providing and fixing flat pressed 3 layer particle board medium density exterior grade (Grade I) or graded wood particle board IS : 3087 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately): : 12 mm thick
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : : Ridges plain (500 - 600mm)
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Flashings/ Aprons. (Upto 600 mm)
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 20 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 32 mm dia nominal bore
Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall: 15 mm dia nominal bore
Providing and fixing brass stop cock of approved quality : : 15 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :32 mm nominal bore.
Providing and fixing Gun metal Gate valve of approved quality :20 mm nominal bore
Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms. : 15 mm nominal bore
Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required :Size 600x450x200 mm
P/fixing cast iron garden benches of size 1.50mtx0.40mtx0.40 mt . The side frames are to be made out of cast iron, seat and back will be made oukt of 50x25 mm Hollow M.S. Tube. All exposed area of bench is to be finisehd with enamel paint.
P/f P.V.C. Sprinkler unit of 20 mm inlet and spray outlet.
Providing, hoisting and fixing above plinth level up to floor five level precast reinforced cement concrete work in string courses, bands, copings, bed plates, anchor blocks, plain window sills and the like, including the cost of required centering, shuttering but , excluding cost of reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.: Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and fixing Aluminium composite panels of exterior applications, 3 mm thick with Aluminium thickness of 0.25 mm, with PVDF coating, in approved colours including filling the joints with exterior applications Silicon in false ceiling/wall panels. The frame work will be paid separately.
Providing and fixing 3 kg glass container for storing seeds.
Providing and fixing 70 mm heavy duty cylindrical stainless steel dead lock i/c S.s. Cap for key & rubber buffer (Dorma/Yale/Godrej)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ). i) Group C
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x2.5 sqmm + 1x2.5 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x4 sqmm + 1x4 sqmm earth wire
Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 4x4 sqmm + 2x4 sqmm earth wire
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connection but excluding modular plate etc. as required. i) 3 pin 5/6 A socket outlet
Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Supplying and fixing 3 pin, 5 A ceiling rose on the existing juction box/wooden block including connection etc. as required.
Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, inc connection with 1.5 sqmm FRLS insulated, copper conductor, single core cable and earthing etc. as required.
Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING). (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreadders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 100A, 16KA, TPMCB
Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A, tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs (But without MCBs and incomer) as required. (Make: Legrand/ Panasonic/ Hager/ Schneider). i) 4 way (4 + 12), Double Door
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Single pole
Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ). i) Triple pole
Suppying and fixing DP sheet steel enclosure on surface/recess along withh 25/32 A 240V 'C' CURVE DP MCB Complete with connection,testing and commissioning etc. as required.
Suppying and fixing TP sheet steel enclosure on surface/recess along withh 16/25/32 A 415V 'C' CURVE TP MCB Complete with connection,testing and commissioning etc. as required.
Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI pipe from earth electrode including connection with copper thimble excavation and refilling as required.
Providing and fixing 4.00 mm dia. Copper wire on surface or in recess for loop earthing along with existing surface/recessed conduit/submaain wiriring/cable as required.
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required. i)Up to 35 sq.mm
Laying and fixing of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size on wall surface as required. i)Upto 35 sq.mm (Clamped with 1mm thick saddle
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductror cable of 1.1 KV Grade as required. i) 3.5x35 sq. mm (32mm)
Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excation and refilling etc as required. 1) Above 4.5 metre and upto 6.5 metre.
Providing and making steel pole collar with cement concrete (1 cement: 3 coarse sand : 6 stone aggregate 20mm) of specified size and shape including form work, plastering if required, curing etc. as required. (volume of pole/ pipe not to be deducted).
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 3.5 core 35 sqmm
Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI ) i) 4 core 16 sqmm
Supplying and testing LED Batten light 20W. (Make: Panasonic / bajaj/ Wipro or Equivalent).
Supplying & fixing Integral Pole Mounted Decorative 40 Watt LED Post Top Lanteren with decorative clear opal acrylic diffuser and IP-65 protection. (Make: Bajaj, Model :Arian, BGCT W4 LED WW 40W LED or Eq ).(Fixing arrangement includes welding of suitable size socket comaptible for Luminaires dia.).
Supplying & fixing MS Tubular Pole 65 mm Dia as per IS2713, 1980 inc. wiring the pole with 2x1.5 sqmm FRLS Copper wire. Pole is of 3.5 Mtr. Length with 3.6 mm thickness, welded at bottom, having 25 mm Dia hole at centre. Painting one coat of red oxide and two coat of black paintetc. as required.
Supplying & installation of Poly Carbonate, Weatherproof, Waterproof with IP 55 Protection street light terminal box with Bus Bar, one no. 6 amp. Single Pole MCB and neutral link including front lockable cover of size 250 x 200 x 105 and connection complete as required. (Make: Sintex or Eq.)
Supplying, Installation, Testing & Commissioning of 3kw A.C unit to cool the area by 7 degree centigrade temperature. Make:-RINAC
RAJEEV SOOD
RITESH SOOD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .