Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.5 CrAccepted-AOC 42 608A PULLOMPARAMBIL HOUSE MANDAKARA ROAD KOCHI 682 018 | ERNAKULAM | KERALA | 682018 | ₹5.5 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹7.3 Cr+₹1.8 Cr (31.9%)Rejected-Finance CHOORAKULATH NEAR GOVT HOSPITAL KUMBALANGHI KOCHI 682 007 | KOCHI | ERNAKULAM | KERALA | 682007 | ₹7.3 Cr+₹1.8 Cr (31.9%) | L2 | Rejected-Finance Rejected being L2 |
Tender Value
Refer Docs
EMD Value
₹4.3 L
Closing Date
30 Apr 2022, 6:00 pmClosed
CE NW Kochi
Kataribagh, Naval Base - 682004
COMPLETION OF INCOMPLETE WORKS OF ADDN/ALTN AND SPECIAL REPAIRS TO DRAINAGE SYSTEM AT NAVAL BASE KOCHI
2022_MES_514325_1
890628
Open Tender
Civil Works
Lump-sum
365 days
Kochi
As per NIT
8 documents required · 8 mandatory
₹2,000
GE (P) NW Kochi
₹4.3 L
Yes
20 May 2022
18 Mar 2022
2 May 2022
18 Mar 2022
30 Apr 2022
16 Apr 2022
19 Mar 2022 - 9 Apr 2022
Amount
LIST OF WORKS
Schedule A Part I to Part VIII)
Total amount of Sch 'A' Part-I (Buildings Works)
Total amount of Sch 'A' Part-II ( Internal Electric Supply)
Total amount of Sch 'A' Part-III (External Electric Supply)
Total amount of Sch 'A' Part-IV (Area Drainage)
Total amount of Sch 'A' Part-V (Road/Path/Culvert)
Total amount of Sch 'A' part-VI (Pump Sets & Pumping Main)
Total amount of Sch 'A' part-VII(Earth Work & Excavation
Sch 'A' Part- VIII(MISCELLANEOUS) Note : This schedule is not pre priced by MES and the pre priced rate indicated as "Rs. 0.00" under Col.5 signifies this fact only.
Material and labour for rectifieing the defects listed in Annexure 4 to Particular specification and any further defects undergone detoriation at site as specified and as directed by Engineer-in-Charge.
Point wiring with PVC insulated unsheathed multistranded copper conductor cable ISI marked, 1100 Volt grade, FRLS of size 1.5Sqmm drawn in and including concealed PVC Rigid conduit of size not less than 20mm dia with MS box concealed and logic modular white plates of suitable size as required at site with PVC insulated unsheathed stranded copper conductor of size 1.5Sqmm as earth wire connected to common earth dolly as specified for one light point controlled by one switch for light/fan as directed. Note:-(i)Rate include cost of making MS box in concealed for cutting and sinkings for boxes and making good to walls, No extra payment will be made for the same.(ii)rtae include the logic modular plates, Necessary blank plates as required at site.
All as per item No 11 above but for one 3 pin 5 Amps switch sockets on Independent board.
All as per Item No 11 above but for one 3 pin 5 Amps switch sockets on same board.
All as per Item No 11 above but with cable of size 2.5Sqmm 1100 Volts grade copper stranded cable with 1.5Sqmm copper stranded conductor as earth wire for one 3 pin socket outlet 15/16Amps.
CFL wall mounted 18 watts to be fitted in holder suitable for 230V 50Hz AC supply.
Fluorescent tube light fitting single tube 1 x 36 Watt 230 volt with tube rod wall mounted etc complete with all accessories internally pre wired and including connecting up with cable from ceiling rose to fitting all as specified and as directed by EIC. Make:- Philips Cat No TMS021 1x TL-D 36WI or equivalent model in other makes mentioned in list of manufacturers.
Exhaust fan 450mm sweep with copper winding complete with metal body and blades and metal bird screen for protection from foregin matter with cable from ceiling rose to exhaust fan. Make:- Crompton Greaves or other makes mentioned in list of manufacturers.
MCB SP 6 to 32Amp 240Volt 50Hz AC supply. Make:- MDS Legrand Cat No 6032 31 to 6032 37 or equivalent in other makes mentioned in list of manufacturers.
Submain wiring with PVC insulated, unsheathed 1100 volts grade, FRLS single core multistranded copper conductor cable 2 run of 4Sqmm drawn through in and including concealed PVC conduit of size not less than 20mm with all accessories on walls/ceiling along with one run of 2.5Sqmm PVC insulated single core unsheathed cable with multistranded copper conductor as earth continuity conductor all as specified and as directed by EIC. Note:- Unit rate include two run of 4Sqmm cable and two run 2.5Sqmm cable and PVC conduit.
CFL street light luminaries with sheet AI housing with UV stabilized acrylic cover with 2 x 28 Watt all fixing arrangement in wall with GI pipe of 40/50mm size bracket as shaped as directed by Engineer-in-Charge. Make:- Philips Cat No HGS 120 2 x TL-28W EBE or equivalent model in other makes mentioned in list of manufacurers.
Providing interlocking steel sheet shoring to the sides of trenches MS sheet 0.5m wide stiffened on edges with 50mmx50mmx6mm Angles driving sown vertically on either side one after another in lines and levels with suitable pile driving equipments and accessories to a maximum depth of 0.5 below the bottom of the propsed excavation 0.5m above ground level suitably braced by horizontal wailing pieces of 75mmx150mmx8mm angles on either side at intervals and maintaining the shoring till the piles and related works completed including dismantling, cleaning and restacking for reuse including all labour hire charges and conveyance of equipments tools and plants and sundries etc complete for above 2.5m upto 6m height all as specified and directed.
Providing interlocking steel sheet shoring to the sides of trenches MS sheet 0.5m wide stiffened on edges with 50mmx50mmx6mm Angles driving sown vertically on either side one after another in lines and levels with suitable pile driving equipments and acce
Taking down/out LT cable from the trenches for diversion of cable of size 185Sqmm 3.5 core all as directed.
All as per Item No 23 above but size 70Sqmm 3.5core.
All as per Item No 23 above but size 35Sqmm 3.5core.
Relaying of existing LT UG cable XLPE of size 185Sqmm 3.5core in trenches all as directed.
Relaying of existing LT UG cable XLPE of size 70Sqmm 3.5core in trenches all as directed.
Relaying of existing LT UG cable XLPE of size 35Sqmm 3.5core in trenches all as directed.
LT UG cable XLPE insulated screened PVC bedded galvanized steel strip or wire armourmed, electric power cable heavy duty 1100volt grade with stanard aluminium conductor of size 3.5core 185Sqmm.
All as per Item No 29 above but 3.5 core 95Sqmm
All as per Item No 29 above but 3.5 core 70Sqmm
All as per Item No 29 above but 3.5 core 50Sqmm
All as per Item No 29 above but 3.5 core 35Sqmm
Double compression copper stainless steel gland for fixing armoured cable in panel 3.5 core 95Sqmm.
All as per Item No 34 above but 3.5 core 50Sqmm
All as per Item No 34 above but 3.5 core 35Sqmm
MCCB TPN 100Amps 25KA in sheet steel enclosure.
All as per Item No 37 above but 250Amps 35KA in sheet steel with enclosure
Outdoor feeder pillar box with 3mm thick CRCA sheet and angle iron frame with IP 65 protection having front opening door and locking arrangement applying 2 coats of synthetic enamel paint over one coat of anti corrosive primer, fix/embedded in PCC block/platform with and including:- (a)MCCB 4 pole 250Amps 35KA-1No (b)MCCB TP 63Amps 25KA-4Nos(Outgoing+ one spare) (c )Aluminium bus bar TPN 400A-1 set (d)Voltmeter 0-500A with S/S-1No (e)Ammeter 0-500A with S/S-1No (f)Indicating lamp set LED type RYB-1 set
All as per Item No 40 above but with the following:- (a)MCCB 4 pole 100Amps 35KA-1No(Incoming) (b)MCB Isolator 3 pol3 40A - 4Nos (c )Aluminium bus bar TPN -1 set (d)Voltmeter 0-500A with S/S-1No (e)Ammeter 0-500A with S/S-1No (f)Indicating lamp set LED type RYB-1 set
Earthing complete with galvanised steel earth plate electrode size 600x600x6.0mm thick burried directly in ground (earth pit of depth not less than 2.25 mtr below normal ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to and including galvanised earth lead 4.0 mm dia protected with GI medium grade pipe 15mm dia for earth electrode up to test point or up to 7.5m whichever is less by means of bolts, nuts, check nuts and washers of copper/brass all as shown in electric plate No 05 of SSR Part I connected to earthing test point all as specified or indicated including provision of necessary excavation and earth work in any type of soil, PCC pit, RCC cover 50mm thick with 8mm dia TMT bars @ 100cm c/c both ways, 20mm bore light grade watering pipe, common salt, charcoal dust, returning , filling in including removal of soil to a distance not exceeding 50m etc including testing on completion all as specified and shown on drawing. Note:- Resistance between neutral and earth shall be less than 1 ohm.
Straight through joints heat shrinkable type suitable for LT cable of size 3.5core 185Sqmm
All as per Item No 42 above but size 70Sqmm 3.5core.
All as per Item No 42 above but size 35Sqmm 3.5core.
315mm HDPE pipe for pumping from sumps to Backwaters/Canals including all fixtures and fittings of PE-100 grade and 10Kg/Sqcm pressure rating all as directed.
Cast iron Air release valve 100mm all as directed.
Cast iron Air release valve 150mm all as directed.
Cleaning of drain of width upto 60cm and depth not exceeding 1.00m which consist of removal/dredging of muck/waste leaves/grass/plants/solid wastes etc complete including removing the waste material to a distance exceeding 1.5Km but not exceeding 5.00Km from the starting point and depositing at a level not exc 1.5m above where directed.
Cleaning of drain of width exceeding 60cm but not exceeding 1.50m and depth not exceeding 1.20m which consist of removal/dredging of muck/waste leaves/grass/plants/solid wastes etc complete including removing the waste material to a distance exceeding 1.5Km but not exceeding 5.00Km from the starting point and depositing at a level not exc 1.5m above where directed.
Cleaning of drain of width exceeding 1.50m but not exceeding 3.00m and depth not exceeding 1.50m which consist of removal/dredging of muck/waste leaves/grass/plants/solid wastes etc complete including removing the waste material to a distance exceeding 1.5Km but not exceeding 5.00Km from the starting point and depositing at a level not exc 1.5m above where directed.
Cleaning of existing canal of width(average)exceeding 3m but not exceeding 6.50m depth not exceeding 1.50m which includes of removal/dredging of muck/waste leaves/grass/solid wastes/plants/flora and fauna etc complete and getting out the muck of any type up to datum level including removing the waste material to a distance exceeding 1.5Km but not exceeding 5.00Km and depositing where directed at a level not exc 1.50m above the starting point.
NEW ITEMS:Material and labour for Cement concrete for foundation filling and concrete using M-15 concrete with 20mm graded aggregate all as specified and as directed by the Engineer-in-Charge.
Providing sand pile of dia 10cm using standard engineering practice to a depth of 6m at an interval of 30cm and filling with 6mm nominal size blue metal and all labour and materials , all related incidental items of work complete all as specified and directed by Engineer-in-Charge. Note: The depth of sand pile shall be measured for payment from the cut off level below sand piling.
Material and labour for Cement concrete for walls, retaining walls, basement walls, ballast walls and the like any thickness above top of footing including attached pilasters and buttresses using M-25 concrete with 20mm graded aggregate all as specified and as directed by the Engineer-in-Charge.
Material and labour for Pre cast Cement concrete (1:11/2 :3) type B1 using 20mm graded aggregate in landings and cover slab set in cement mortar 1:4 including form work complete all as specified and as directed by the Engineer-in-Charge.
Classic Builders
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .