Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC 21 167 KAKANI NAGAR 2ND LANE NAD POST VISAKHAPATNAM 530009 | VISAKHAPATANAM | ANDHRA PRADESH | 530009 | L1 | Accepted-AOC THE LOWEST BIDDER | |
| 2 | L2₹17.2 L+₹52,495.40 (3.15%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹17.2 L+₹53,814.25 (3.23%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹17.4 L+₹71,471.90 (4.29%)Rejected-Finance D NO 38 39 86 3 4 SAIKRUPA RESIDENCY 104 AREA BAPUJI NAGAR MARRIPALEM VISAKHAPATNAM 530 007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹17.6 L+₹94,455.50 (5.67%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹17.5 L
EMD Value
₹35,000
Closing Date
29 Jul 2023, 6:00 pmClosed
AGE (I) (CG) Vizag
AGE (I) (CG) Vizag Military Engineer Services CGWO, 530014 VISAKHAPATNAM
REPAIRS/ MAINTENANCE OF WATER SUPPLY DISTRIBUTION LINE NETWORK, PUMPS, PANEL OF WATER SUPPLY INSTALLATION AND ALLIED WORKS AT ICGS MALKAPURAM AND JETTY COMPLEX, VISAKHAPATNAM UNDER AGE(I)(CG) VIZAG
2023_MES_608438_1
AGE(I)CG/VIZ/TOKEN 30 OF 2023-24
Open Tender
Miscellaneous Works
Item Rate
180 days
VISAKHAPATNAM
DETAILS AS PER NIT OF THE TENDER
9 documents required · 9 mandatory
₹500
AGE (I) (CG) Vizag
₹35,000
Yes
17 Oct 2023
10 Jul 2023
31 Jul 2023
10 Jul 2023
29 Jul 2023
23 Jul 2023
Amount
M & L for cleaning of UG Sump of 100000/150000 Litre capacity at CG Enclave by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed and the cleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding painting the details such as sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump internally complete all as directed by Engr-in-charge
M & L for cleaning of UG Sump of 50000 Litre capacity at CG Enclave by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositing and levelling as directed and the cleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding painting the details such as sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump internally complete all as directed by Engr-in-charge.
M & L for cleaning of UG Sump of 30000 Litre capacity at CG Enclave by pumping out the accumulated water at the bottom and removing the complete silt from the sump and depositingand levelling as directed and the cleaning the sump with bleaching powder and wire bursh after scrapping the walls and bottom of the sump completely without disturbing the water supply to the area inlcuding painting the details sump capacity, date of cleaning and due date of cleaning on the sump wall and applying one coat of white wash to entire sump internally complete all as directed by Engr-in-charge.
Material and labour for repairing of water supply starter panel board internally, detecting fault in control wiring, contractor, relay, time delay and connecting block including replacement of worn out spare parts with new items as per existing make and specification, Testing and commissioning with entire satisfaction of Engr-in-charge and applying two coats of synthetic enameled paint after scrubbing and cleaning the surfaces including its rewiring and replacement of defective appliances with new parts and testing complete. (Notes : Spare parts shall be Measured & Paid separately under relevant supply only items)
Supply only Contactor ML-3 / ML-4, 450 Volts
Supply only DOL Stater suitable for 10-7.5 HP
Supply only indicating lamp (set of 3)
Supply only Single phase preventor
Supply only Ameter 0-100Amps with suitable CTs
Supply only Voltmeter 0-500 volts with suitable PTs
Supply only Relay 30-40 Amp
Supply only Timer for starter
Supply only Copper conductor flexible wire 40/0.0076
Supply only Frequency meter 50Hz
Supply only MCCB 250 Amps 4 Pole 36 KA adjustable type for earth fault and overload current.
Supply only Phase reverse preventor,
S&F in repair sluice valve 100 mm dia, heavy duty both ends flanged class PN-I.6, ISI marked with stainless steel spindle, cast iron hand operated wheel & cap top nuts, bolts , washers including rubber gasket joints and taking out existing sluice valve all as specified
S&F in repair sluice valve 80 mm dia, heavy duty both ends flanged class PN-I.6, ISI marked with stainless steel spindle, cast iron hand operated wheel & cap top nuts, bolts , washers including rubber gasket joints and taking out existing sluice valve all as specified
S&F gun metal globe or gate valves 50 mm bore , with iron wheel head (ISI marked ) screwed both ends fixed in repairs complete all as directed.
All as per Srl Item No. 20 here-in-before but 40 mm bore
All as per Srl Item No. 20 here-in-before but 25 mm bore
All as per Srl Item No. 20 here-in-before but 20mmbore
All as per Srl Item No. 20 here-in-before but 15mm bore
S & F Ball brass valves 20 mm,high pressure,with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed
S & F in repairs MCCB of 200 Amps and supply and fixing 4 pole MCCB 200 Amps 50 Hz, 415V, adjustable with thermal magnetic release and rupturing capacity 36 KA all as directed. Make: L&T/Havells/C&S/ SCHNEIDER / Indoasian
S & F in repairs MCCB of 63 Amps 4 pole, 50 Hz, 415V, adjustable with thermal magnetic release and rupturing capacity 16 KA all as directed. Make: L&T/Havells/C&S/ SCHNEIDER / Indoasian
Supply and lay in repair GI tubes 40 mm Dia bore Medium Grade galvanised with all fittings laid in trenches etc for protection of cable of following sizes all as directed.
All as per Srl Item No. 28 here-in-before but 50 mm Dia bore
All as per Srl Item No. 28 here-in-before but 80 mm Dia bore
Supplying and laying of 32 mm Dia bore CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings in trenches complete all as specified.
All as per Srl Item No. 31 here-in-before but 40 mm Dia bore
All as per Srl Item No. 31 here-in-before but 50 mm Dia bore
Supply and fixing in repair UPVC ball valve of size 50 mm dia complete all as specified
Supply and laying in repair High density poly ethylene pipes (HDPE) 32 mm Dia bore of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete including necessary accessaries complete all as specified.
All as per Srl Item No. 35 here-in-before but 40 mm Dia bore
All as per Srl Item No. 35 here-in-before but 50 mm Dia bore
Supply and lay 3 layer (inner antimicrobial, outer UV stabilized) ISI marked, IS-15801, PP R pipes 110 mm Dia bore SDR 7.4 (PN-16) and PP-R plain fititngs in trenches/walls/cellings or laying in floors complete of size outer dia including taking down old pipes.
All as per Srl Item No. 38 here-in-before but 90 mm Dia bore
All as per Srl Item No. 38 here-in-before but 50 mm Dia bore
All as per Srl Item No. 38 here-in-before but 40 mm Dia bore
All as per Srl Item No. 38 here-in-before but 25 mm Dia bore
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr depth for laying of cables,tubes, foundation of poles etc and getting out in soft/loose soil. Complete all as specified and directed.
Returning, filling in including spreading levelling watering and well ramming in layers not exc 25cm in any type of soil all as directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point all as directed.
S & F in repairs Cast Iron Foot valve 80 mm dia. (Make: Kirloskar/Upadhaya)
All as per Srl Item No. 46 here-in-before but 100 mm dia
Supply and fixing in repairs Automatic Water level controller suitable up to 3 HP submersible Pump/Booster Pump with 25%, 50%, 75% and 100 % water sensor provision inside tank and automatic operation of pumps with the provision of automatic pumps start and automatic pumps stop when it reach at 100% with connecting cable of 4 sqmm copper cable not less than 50 meter for over head tank to starter and connecting control cable suitably provide not less that 6 sqmm complete with its control with the provision of Contactor and relay of adequate capacity including connected items for its control and sensing all as specified and as directed. Make-Southern/sheco/RS
Dismantling damage and broken valve chamber of size 1200x1200x900mm including U/S rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50 x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.
Dismantling damage and broken valve chamber of size 450x450x450mm including U/S rusted MS cover complete without disturbing the existing pipe lines valves and provide valve chamber including necessary earth work in any type of soil PCC 1:1.5:3 in base concrete brick work in CM (1:6) with 10mm thick plaster internally and 15mm thick externally in CM (1:4) 6mm thick MS sheet cover with hinges and locking arrangements fixed to angle iron frame made out of 50x50x6mm MS complete with 2 coat of synthatic enameled paint over a coat of red oxied on all steel work and 2 coats of white washing on plastered surface of valve chamber of any sizes complete all as specified and as directed by Engr - in- charge.
Material labour for water sample test, taking sample water in sterlised bottles from UG Sump for Analysis of water for the following parameters and obtaining sample test report from Govt Recognized Laboratories: (i) Physio Chemical Analysis of Water (Colour, odour, pH Total solids, Dissolved Solids, Permanent hardness, temporary Hardness, Ammonia feree and salinbe, Ammonia Albuminoidal, Nitrites, Nitreates, Oxygen absorption at 15 Min, Iron, Fluoride) (ii) Microbiological Analysis (Totral Choliforms, Eschirrchea Coli) Notes: (i). A certificate of approval / certification of Lab by Govt of India / State Govt. shall be submitted by the contractor to the deptt. (ii). Sample shall be submitted to the Laboratory with in 24 Hrs of collection of Sample.
M&L in repair Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not lessthan 2.25 M deep below normal GL) with top edge of the plate not less than 1.5M below normal GL, connected to Galvanized earth strip 32x6 mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way,40mm dia light grade GI protection pipe, funnel with wire mesh, watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr all as per SSR Part-I 2009 specification. including Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I
Supply and laying in repairs and testing submersible flat copper cable PVC insulated heavy duty electric cable 6 Sqmm 3 core screened pvc bedded, 1100 Volt grade laid in borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed
Supply and laying in repairs and testing submersible flat copper cable PVC insulated heavy duty electric cable 4 Sqmm 3 core screened pvc bedded, 1100 Volt grade laid in borewell complete from starter to submersible pump including taking out old unserviceable/burnt cable complete all as specified and directed
S&F in repair Non Return valve 80 mm dia, heavy duty both ends flanged class PN-I.6, ISI marked with nuts, bolts , washers including rubber gasket joints and taking out existing non return valve all as specified
S&F in repair Non Return valve 100 mm dia, heavy duty both ends flanged class PN-I.6, ISI marked with nuts, bolts , washers including rubber gasket joints and taking out existing non return valve all as specified
MSN ENGINEERING WORKS
SAI ENGINEERING WORKS
VENKATESWARA ENGINEERS AND CONTRACTORS
GVR ENGINEERING WORKS
PRC ENTERPRISES
SATYAM ENGINEERS
G T SERVICES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .