Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.4 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹21.1 L+₹66,330 (3.24%)Rejected-Finance 704 SILVER DEAL DAFFODIL WING 1 B T KAWADE ROAD PUNE 411 001 | PUNE | PUNE | MAHARASHTRA | 411001 | L2 | Rejected-Finance High Rate | |
| 3 | L3₹22.0 L+₹1.5 L (7.52%)Rejected-Finance | L3 | Rejected-Finance High Rate | |
| 4 | L4₹22.1 L+₹1.7 L (8.11%)Rejected-Finance 3RD FLOOR VVIP RESIDENCY MAHINDER VIHAR CHAKRATA RD NEAR RAMADA HOTEL DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-Finance High Rate | |
| 5 | L5₹27.3 L+₹6.8 L (33.5%)Rejected-Finance | L5 | Rejected-Finance High Rate |
Tender Value
₹32.5 L
EMD Value
₹65,000
Closing Date
10 Feb 2020, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Arjun Marg Pune-411001
8136 PROVIDING OF SERVICES FOR OPERATION OF SUB STATION IN THE AREA OF AFMC OLD NDA WING INCLUDING ASI AREA AND AIPT AREA UNDER GE CENTRAL PUNE
2019_MES_299840_2
8136 PROVIDING OF SERVICES FOR OPERATION OF SUB
Open Tender
Electrical Maintenance Service
Item Rate
335 days
Garrison Engineer (Central) Pune
As per tender
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹65,000
Yes
15 Feb 2020
27 Jan 2020
12 Feb 2020
27 Jan 2020
10 Feb 2020
3 Feb 2020
Amount
Providing services for operation of the following sub stations combined with Complaint cells in the area of AFMC, Old NDA Wing including ASI Area and AIPT area by attending various HT/LT faults / break downs in the sub station jurisdiction, attending the various complaints as and when required round the clock in three shifts, separately by three fully experienced Electricians (one electrician in each shift in each area) in each shift of 08 hours including holidays and Sundays etc complete all as specified and directed by Engr-in-Charge. (i) Three electricians in three shifts (i.e. 01 Electrician in AFMC, 01 Electrician in Old NDA Wing including ASI Area, 01 Electrician in AIPT area in each shift) as under :- - 0600 hrs to 1400 hrs : First Shift - 1400hrs to 2200 hrs : Second Shift - 2200 hrs to 0600 hrs : Third Shift
Emergency breakdown services are to be attended for the following substations comes under AFMC area.
(a) AFMC main substation combined with Complaint cell including Transformers 300 & 500 KVA feeding to AFMC HQ bldg and all connected areas along with HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(b) Transformer 200 KVA installed at 450 OR's pump house locations including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(c) Transformer 100 KVA at Laundry area including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(d) Transformer 50 KVA at JCOs QTR area including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(e) Transformer 200 KVA at 53 OR's area including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(f) Transformer 160 KVA at Girls Hostel area including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(g) Transformer 500 KVA ,100KVA & 160KVA at Boys Hostel pump house. including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(h) Transformer 315 KVA at Central Cadet Mess including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(j) Transformer 200 KVA at KT line including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(k) Transformer 250 KVA at BTD including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(l) Transformer 400 KVA & 315KVA at Dhanwantari Auditorium and complex including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(m) Transformer 250 KVA at Pump house for offrs mess including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(n) Transformer 200 KVA at Golden Jubilee Block including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete all as specified and directed.
(o) Transformer 250 KVA & 200KVA at MRI & IRC including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(p) Transformer but 400 KVA & 315 KVA at Diamond Jubilee Block including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(q) Transformer 200 KVA at New Library including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(r) Transformer 160 KVA at New BTD including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(s) Transformer 200KVA at CT scan including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(t) Transformer 200KVA at Golden jubilee for offrs mess including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(u) Transformer 400KVA at project Qtrs area including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(v) Transformer 200KVA at PWD 12 including HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
(w) Transformer 200KVA at ALC Dhobi ghat including HT/ LT control panels, GOD/Dos, HT/LT cables, over head lines, under ground cables etc complete all as specified and directed.
Emergency breakdown services are to be attended for the following sub stations comes under Old NDA wing and ASI area.
(a) Old NDA wing area substation combined with Complaint cell including Transformers 400KVA feeding to Old NDA wing area and 500 KVA feeding to ASI area along with HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete.
Emergency breakdown services are to be attended for the following sub stations comes under AIPT area.
(a) AIPT area substation combined with Complaint cell including Transformers 400 KVA / 315 KVA feeding to AIPT area along with HT/ LT control panels, GOD/DOs, HT/LT cables, over head lines, under ground cables etc complete .
Notes for the item No 1 :-
(i) Rates quoted by the tenderer for the above items shall deemed to be inclusive of cost required for general cleaning of sorrounding area of the installation complete.
(ii) Protective clothing as per IS and safety instructions are to be provided by the contractor and will be continuously in use of the FGM / electrician on duty. No extra payment shall be made to the contractor for the same.
(iii) Log sheet shall be maintained by the contractor properly as per the format approved by Engineer-in-Charge and the same shall be handed over to Engineer-in-Charge on completion of contract period.
(iv) Day to day maintenance shall be carried out by the contractor. Materials other than grease, glands shall be supplied by the department.
(v) The contractor shall employ adequate tradesmen for weekly off, holiday and leave replacement and the cost of the same shall deemed to be included in the quoted rate and no additional amount will be paid in this respect.
(vi) All stationary items such as daily log sheet, attendance register, Complaint register for complaint cell shall be supplied by the contractor without any extra cost.
M/S - KRUPA ELECTRICALS
Apurva constructions
M/S DHEER ENGINEERING
Suchit constructions
AIRCON SYSTEMS
metro electrical services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .