Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance GROUND FLOOR PLOT NO 34 245 BETHI COLONY KHATODRA NR UDHNA DARWAJA SURAT SURAT GUJARAT 395002 SURAT GUJARAT 395002 | SURAT | GUJARAT | 395002 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 4 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
Refer Docs
Closing Date
27 Jan 2026, 9:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Engineer Officer
Engineer Officer ICGS sarthak For Commanding Officer
Various Engg Defect rectification as per RFP
2026_ICG_749511_1
344/40/EN/STK/2025-26
Limited
Marine Works
Works
Porbandar
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
Exempted
28 Jan 2026
21 Jan 2026
28 Jan 2026
21 Jan 2026
27 Jan 2026
21 Jan 2026
E-904:Following valves of various system not holding due to worn out spindle & seat. Valves to be overhauled and pressure tested up to 10 bar. In way job includes removal and fitment of valves. Ser Description Size Qty 1. Fwd Port tank inlet Gate valve 40 mm 01 No. 2. Fire main gate valve 80 mm 02 No. 3. FER fireman supply SDNR valve 65 mm 02 No.
E-905:Fire & sprinkling pump priming unit ball valve not holding. Same to be renewed along with adaptor as per sample. (Qty-02 Nos.)
E-906:Leakage and abnormal noise observed from Stbd WHR pump. Suspect mechanical seal and bearing worn out. Pump to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of pump
E-907:DA No.1 sea chest strainer change over unit stuck in position. Same to be overhauled and proved for satisfactory operation. In way job includes removal and fitment of unit.
E-908:Motor driven diving air compressor not developing sufficient pressure due to defective safety valve. Same to be renewed/ repaired as per sample. (Qty-01 no., Set pressure-330 bar)
E-909: Fwd HP air compressor not developing sufficient pressure. Suspect loader/unloader mechanism and solenoid valve malfunctioning. DI/DR to be carried out and proved for satisfactory operation.
E-910:Defueling point flange at quarter deck observed deteriorated. Same to be fabricated as per sample (Mat:-MS, Qty:02 Nos.)
E-911: AVCAT fuel leakage observed from AVCAT system pipeline due to worn out pipeline thread. Leakage to be arrested by threading on pipeline and proved for satisfactory operation. In way job includes removal and fitment of pipeline.
E-912: Lub oil leakage observed from lub oil filter assembly on DA no. 2 due to worn out internal thread of filter assembly. Leakage to be arrested by threading on assembly. In way job includes removal and fitment of filter assembly and associated system.
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.05 MB
BOQ_839405.xls
BOQ • 0.39 MB
RFP.PDF
Tender Documents • 3.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .