Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAdmitted-Fee/PreQual/Technical/Finance | L1 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | ABDUL NAZER K L1 |
|---|---|---|---|---|
| 1.00Electrical | ||||
| 1.00 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | 1 | point | 1,552.9 ₹1,552.9 Lowest |
| 1.00 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | 1 | each | 116.2 ₹116.2 Lowest |
| 1.00 | OD484770/2025-2026:Supply and fixing of 9W LED Bulb, as required | 1 | each | 159.7 ₹159.7 Lowest |
| 1.00 | OD484657/2025-2026:Supply and installation testing and commissioning of 7.5HP Open well Vertical submersible motor pump at rated voltage three phase 415/440V, 50 Hz, AC supply having a head range of 45-116m providing discharge rate of 360 -60LPM with standard size delivery pipe as company's make connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary GI bracket support on top sides of the motor including giving connection as per the direction at site. (Texmo/Kirloskar/Deccan) | 1 | each | 63,348.5 ₹63,348.5 Lowest |
| 1.00 | OD484658/2025-2026:Supply, Installation, Testing and Commissioning of Star Delta Starter Panel for 7.5HP Submersible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. L&T make | 1 | each | 9,626.2 ₹9,626.2 Lowest |
| 1.01 | OD484668/2025-2026:Supply threading, laying and joining of 63 mm/nearest size Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required. | 70 | metre | 204.9 ₹14,343 Lowest |
| 1.01 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | 70 | metre | 132.6 ₹9,282 Lowest |
| 1.01 | OD484670/2025-2026:Supply and providing 63 mm/nearest size dia Gun Metal Non return valve (ISI) | 1 | each | 1,185.9 ₹1,185.9 Lowest |
| 1.01 | OD484661/2025-2026:Supply and providing 63mm/ Nearest size dia Full way valve (ISI) | 1 | each | 1,237.3 ₹1,237.3 Lowest |
Tender Value
₹1.6 L
EMD Value
₹3,940
Closing Date
30 May 2026, 11:00 amClosed
ASSISTANT ENNGINEER JAYARAJ K S
LID EW THONDERNAD GP
INSTALLATION OF MOTOR AT CHELATTIL UNNATHI PUBLIC WELL THONDARNAD GP-PROJ NO.S0355/26
2026_LSGD_845510_10
AE/TENDER/09A/2025-26/LSGD
Open Tender
Civil Works - Others
Item Rate
THONDERNAD GP
Please refer Tender documents.
7 documents required · 7 mandatory
₹555
Yes
₹3,940
Yes
10 Jun 2026
22 May 2026
1 Jun 2026
22 May 2026
30 May 2026
22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Electrical | |||||
| 1.001 | 1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC
insulated copper conductor single core cable in surface / recessed medium class PVC conduit,
with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS
PVC insulated copper conductor single core cable etc as required.Group C | - | point | - | - |
| 1.002 | 1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required. | - | each | - | - |
| 1.003 | OD484770/2025-2026:Supply and fixing of 9W LED Bulb, as required | - | each | - | - |
| 1.004 | OD484657/2025-2026:Supply and installation testing and commissioning of 7.5HP Open well Vertical submersible motor pump at rated voltage three phase 415/440V, 50 Hz, AC supply having a head range of 45-116m providing discharge rate of 360 -60LPM with standard size delivery pipe as company's make connected one by one to the motor up to the bottom of the well using leak proof materials as required with necessary GI bracket support on top sides of the motor including giving connection as per the direction at site. (Texmo/Kirloskar/Deccan) | - | each | - | - |
| 1.005 | OD484658/2025-2026:Supply, Installation, Testing and Commissioning of Star Delta Starter Panel for 7.5HP Submersible motor comprising of Relay, LED Indicator, Voltmeter, Ammeter, Contactor, Capacitor etc as required. L&T make | - | each | - | - |
| 1.006 | OD484668/2025-2026:Supply threading, laying and joining of 63 mm/nearest size Submersible Column/HDPE Pipe for submersible pump, approved make specials as delivery pipe using required leak proofing materials etc. as required. | - | metre | - | - |
| 1.007 | 90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm | - | metre | - | - |
| 1.008 | OD484670/2025-2026:Supply and providing 63 mm/nearest size dia Gun Metal Non return valve (ISI) | - | each | - | - |
| 1.009 | OD484661/2025-2026:Supply and providing 63mm/ Nearest size dia Full way valve (ISI) | - | each | - | - |
stage.html
html • 0.01 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.80 MB
BOQ_1440345.xls
BOQ • 0.32 MB
nit355.pdf
Tender Documents • 0.04 MB
sbd355.pdf
Tender Documents • 1.63 MB
0Tennderdocs.pdf
Tender Documents • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .